P. , Fléau moderne et médecine d'avenir, Actes de la Recherche en, Sciences Sociales, vol.68, issue.1, pp.45-76, 1987.

E. J. Odes, P. S. Randolph-quinney, M. Steyn, Z. Throckmorton, J. S. Smilg et al., Earliest hominin cancer : 1.7-million-year-old osteosarcoma from Swartkrans Cave, South African Journal of Science, vol.112, issue.7, pp.5-5, 2016.

E. Molto and P. Sheldrick, Egypt : Case studies and a paleoepidemiological perspective, Paleo-oncology in the Dakhleh Oasis, vol.21, pp.96-110, 2018.

J. C. Wright, Cancer Chemotherapy: Past, Present, and Future-Part I, Journal of the National Medical Association, vol.76, issue.8, pp.773-784, 1984.

T. Bardinet, Les Papyrus médicaux de l'Egypte pharaonique, Revue d'histoire des sciences, vol.50, pp.486-486, 1995.

A. Karpozilos and N. Pavlidis, The treatment of cancer in Greek antiquity, European Journal of Cancer, vol.40, issue.14, pp.2033-2040, 2004.

C. Micallef, K. D. Shield, J. Vignat, I. Baldi, B. Charbotel et al., Cancers in France in 2015 attributable to occupational exposures, vol.222, pp.22-29, 2019.
URL : https://hal.archives-ouvertes.fr/hal-02159287

, New Global Cancer Data: GLOBOCAN 2018 | UICC, p.11, 2018.

G. Noël, D. Antoni, and P. , Cancer/Radiothérapie, vol.20, issue.6, p.23, 2016.

A. Brahme, J. E. Roos, and I. Lax, Solution of an integral equation encountered in rotation therapy, Phys Med Biol, vol.27, issue.10, p.14, 1982.

C. X. Yu, Intensity-modulated arc therapy with dynamic multileaf collimation : an alternative to tomotherapy, Phys Med Biol, vol.40, issue.9, p.14, 1995.

M. Durante and H. Paganetti, Nuclear physics in particle therapy : a review, vol.79, p.48, 2016.

W. H. Bragg, R. Kleeman, and L. , On the ionization curves of radium, The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, vol.8, issue.48, pp.726-738, 1904.

R. R. Wilson, Radiological Use of Fast Protons, Radiology, vol.47, issue.5, pp.487-491, 1946.

P. D. Rosahn, C. A. Tobias, and J. H. Lawrence, Effects on the White Mouse of a Single Whole-Body Exposure to 190 mev. Deuterons, Am J Pathol, vol.28, issue.1, pp.37-49, 1952.

C. A. Tobias, D. C. Van-dyke, M. E. Simpson, H. O. Anger, R. L. Huff et al., Irradiation of the pituitary of the rat with high energy deuterons, Am J Roentgenol Radium Ther Nucl Med, vol.72, issue.1, p.15, 1954.

J. H. Lawrence, Proton irradiation of the pituitary, Cancer, vol.10, issue.4, p.15, 1957.

J. H. Lawrence, C. A. Tobias, J. L. Born, R. K. Mccombs, J. E. Roberts et al., Pituitary irradiation with high-energy proton beams : a preliminary report, Cancer Res, vol.18, issue.2, p.15, 1958.

B. Larsson, L. Leksell, B. Rexed, P. Sourander, W. Mair et al., The High-Energy Proton Beam as a Neurosurgical Tool, Nature, vol.182, issue.4644, p.1222, 1958.

S. Graffman, A. Brahme, and B. Larsson, Proton radiotherapy with the Uppsala cyclotron. Experience and plans, Strahlentherapie, vol.161, issue.12, p.15, 1985.

E. S. Gragoudas, M. Goitein, A. M. Koehler, L. Verhey, J. Tepper et al., Proton irradiation of small choroidal malignant melanomas, American Journal of Ophthalmology, vol.83, issue.5, p.15, 1977.

J. D. Slater, J. M. Slater, and S. Wahlen, The potential for proton beam therapy in locally advanced carcinoma of the cervix, International Journal of Radiation Oncology, vol.22, issue.2, p.15, 1992.

. Ptcog--home, , p.18

Z. Taheri-kadkhoda, N. Pettersson, T. Björk-eriksson, and K. Johansson, Superiority of intensity-modulated radiotherapy over three-dimensional conformal radiotherapy combined with brachytherapy in nasopharyngeal carcinoma : a planning study, Br J Radiol, vol.81, issue.965, pp.397-405, 2008.

R. Ferrand and L. Protonthérapie, technique de pointe à l'interface entre la physique et la médecine, pp.4-9, 2011.

I. I. , du Cancer, Protonthérapie, indications et capacité de traitement, Appui à la décision / Soins, 2016, ref : ADPROTONTHERAPIE16, p.18, 2016.

H. Bethe, Bremsformel für Elektronen relativistischer Geschwindigkeit, vol.76, pp.293-299, 1932.

W. H. Barkas, J. N. Dyer, and H. H. Heckman, Resolution of the ? ? -mass anomaly, Phys. Rev. Lett, vol.11, pp.26-28, 1963.

F. Bloch, Zur Bremsung rasch bewegter Teilchen beim Durchgang durch Materie, vol.408, pp.285-320, 1933.

M. Berger, J. Coursey, M. Zucker, and J. Chang, Stopping-Power & Range Tables for Electrons, Protons, and Helium Ions, 2017.

,

G. Molière, Theorie der Streuung schneller geladener Teilchen II. Mehrfach-und Vielfachstreuung, vol.3, pp.78-97, 1948.

A. V. Chvetsov and S. L. Paige, NOTE : The influence of CT image noise on proton range calculation in radiotherapy planning, Physics in Medicine and Biology, vol.55, pp.141-149, 2010.

S. España and H. Paganetti, Uncertainties in planned dose due to the limited voxel size of the planning CT when treating lung tumors with proton therapy, Phys Med Biol, vol.56, issue.13, pp.3843-3856, 2011.

F. Albertini, A. Bolsi, A. J. Lomax, H. P. Rutz, B. Timmerman et al., Sensitivity of intensity modulated proton therapy plans to changes in patient weight, Radiother Oncol, vol.86, issue.2, pp.187-194, 2008.

M. Van-herk, P. Remeijer, C. Rasch, and J. V. Lebesque, The probability of correct target dosage : dose population histograms for deriving treatment margins in radiotherapy, International Journal of Radiation Oncology, vol.47, issue.4, pp.1121-1135, 2000.

D. Mihailescu and E. Al, Biophysical models in hadrontherapy, Journal of Advanced Research in Physics, vol.3, issue.1, 2017.

R. Ardaillou and R. Tubiana, Med Sci, vol.29, issue.12, p.31, 2008.

M. Krämer and G. Kraft, Calculations of heavy-ion track structure, Radiation and Environmental Biophysics, vol.33, issue.2, p.31, 1994.

B. J. Mijnheer, L. J. Goodman, E. J. Hall, H. G. Menzel, C. J. Parnell et al., J ICRU, vol.23, issue.2, pp.86-88, 1989.

T. Friedrich, U. Scholz, T. Elsässer, M. Durante, and M. Scholz, Systematic analysis of RBE and related quantities using a database of cell survival experiments with ion beam irradiation, J. Radiat. Res, vol.54, issue.3, p.33, 2013.

J. S. Loeffler and M. Durante, Charged particle therapy-optimization, challenges and future directions, Nat Rev Clin Oncol, vol.10, issue.7, pp.411-424, 2013.

C. Divay, Etude de la fragmentation du ¹²C pour la hadronthérapie, phdthesis, Normandie, 2017.

E. Lartigau, Radiosensibilisateurs des cellules hypoxiques : passé, présent et avenir, vol.2, pp.775-780, 1998.

E. Brun, Vers la compréhension de l'effet radiosensibilisateur de nanoparticules d'or soumises à un rayonnement X, phdthesis, p.11, 2009.

E. Nolte, Etude du potentiel pro-apoptotique et radiosensibilisateur de quatre candidatsmédicaments régulateurs des microtubules, sur des cellules de cancer du sein, phdthesis, 2019.

N. Sadeghi, R. Kok, C. Bos, M. Zandvliet, W. Geerts et al., Hyperthermia-triggered release of hypoxic cell radiosensitizers from temperature-sensitive liposomes improves radiotherapy efficacy in vitro, Nanotechnology, 2019.

S. Rawal and M. M. Patel, Threatening cancer with nanoparticle aided combination oncotherapy, Journal of Controlled Release, 2019.

M. Mirrahimi, M. Khateri, J. Beik, F. S. Ghoreishi, A. S. Dezfuli et al., Enhancement of chemoradiation by co-incorporation of gold nanoparticles and cisplatin into alginate hydrogel, Journal of Biomedical Materials Research Part B : Applied Biomaterials, issue.0, p.0

H. Iwata, H. Ogino, S. Hashimoto, M. Iwana, H. Shibata et al., Oxygen Enhancement Ratio of Proton Beams : The Precise Report of the Same Institution's Experiments Using the Clinical Equipments, International Journal of Radiation Oncology ? Biology ? Physics, vol.90, issue.1, p.779, 2014.

L. Antonovic, E. Lindblom, A. Dasu, N. Bassler, Y. Furusawa et al., Clinical oxygen enhancement ratio of tumors in carbon ion radiotherapy : the influence of local oxygenation changes, Journal of Radiation Research, vol.55, issue.5, pp.902-911, 2014.

C. Laurent, Oxidative Stress in Hadrontherapy, Novel Prospects in Oxidative and Nitrosative Stress, 2018.

W. D. Newhauser and M. Durante, Assessing the risk of second malignancies after modern radiotherapy, Nat. Rev. Cancer, vol.11, issue.6, pp.438-448, 2011.

J. R. Castro, Results of heavy ion radiotherapy, Radiat Environ Biophys, vol.34, issue.1, p.33, 1995.

D. Grün, A. Lyubimova, L. Kester, K. Wiebrands, O. Basak et al., Single-cell messenger RNA sequencing reveals rare intestinal cell types, Nature, vol.525, issue.7568, p.38, 2015.

E. Scifoni, W. Tinganelli, W. K. Weyrather, M. Durante, A. Maier et al., Including oxygen enhancement ratio in ion beam treatment planning : model implementation and experimental verification, Phys Med Biol, vol.58, issue.11, p.36, 2013.

W. Tinganelli, M. Durante, R. Hirayama, M. Krämer, A. Maier et al., Kill-painting of hypoxic tumours in charged particle therapy, Scientific Reports, vol.5, p.36, 2015.

F. Tommasino, E. Scifoni, and M. Durante, New Ions for Therapy, International Journal of Particle Therapy, vol.2, issue.3, p.38, 2015.

N. B. Remmes, M. G. Herman, and J. J. Kruse, Optimizing normal tissue sparing in ion therapy using calculated isoeffective dose for ion selection, Int. J. Radiat. Oncol. Biol. Phys, vol.83, issue.2, pp.756-762, 2012.

M. Krämer, E. Scifoni, F. Schmitz, O. Sokol, and M. Durante, Overview of recent advances in treatment planning for ion beam radiotherapy, Eur. Phys. J. D, vol.68, issue.10, p.306, 2014.

H. R. Withers, J. M. Taylor, and B. Maciejewski, Treatment volume and tissue tolerance, Int. J. Radiat. Oncol. Biol. Phys, vol.14, issue.4, p.38, 1988.

C. Peucelle, C. Nauraye, A. Patriarca, E. Hierso, N. Fournier-bidoz et al., Prezado, Proton minibeam radiation therapy : Experimental dosimetry evaluation, Medical Physics, vol.42, issue.12, pp.7108-7113, 2015.

C. Guardiola, C. Peucelle, and Y. Prezado, Optimization of the mechanical collimation for minibeam generation in proton minibeam radiation therapy, Medical Physics, vol.44, issue.4, pp.1470-1478, 2017.
URL : https://hal.archives-ouvertes.fr/hal-01815188

A. Patriarca, C. Fouillade, M. Auger, F. Martin, F. Pouzoulet et al., Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System, International Journal of Radiation Oncology*Biology*Physics, vol.102, issue.3, pp.619-626, 2018.

J. Zhang, M. Knopp, K. Binzel, C. Wright, P. Maniawski et al., The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation, vol.59, pp.216-216, 2018.

R. A. Petrelli, IEEE Distinguished Lecture : The 10ps Time-of-Flight PET Challenge, p.57, 2019.

G. Shakirin, H. Braess, F. Fiedler, D. Kunath, K. Laube et al., Implementation and workflow for PET monitoring of therapeutic ion irradiation : a comparison of in beam, in room, and off line techniques, Physics in Medicine and Biology, vol.56, issue.5, pp.1281-1298, 2011.

Y. Iseki, H. Mizuno, Y. Futami, T. Tomitani, T. Kanai et al., Positron camera for range verification of heavy-ion radiotherapy, Nuclear Instruments and Methods in, Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment, vol.515, issue.3, pp.840-849, 2003.

D. W. Litzenberg, D. A. Roberts, M. Y. Lee, K. Pham, A. M. Vander-molen et al., On-line monitoring of radiotherapy beams : Experimental results with proton beams, Medical Physics, vol.26, issue.6, pp.992-1006, 1999.

H. D. Maccabee, U. Madhvanath, and M. R. Raju, Tissue activation studies with alpha particle beams, Physics in Medicine and Biology, vol.14, issue.2, p.58, 1969.

P. A. Vieira-crespo, Optimization of In-Beam Positron Emission Tomography for Monitoring Heavy Ion Tumor Therapy, p.phdthesis, 2005.

P. Crespo, G. Shakirin, F. Fiedler, W. Enghardt, and A. Wagner, Direct time of flight for quantitative, realtime inbeam PET : a concept and feasibility study, Physics in Medicine and Biology, vol.52, issue.23, pp.6795-6811, 2007.

T. Nishio, A. Miyatake, T. Ogino, K. Nakagawa, N. Saijo et al., The development and clinical use of a beam ON-LINE PET system mounted on a rotating gantry port in proton therapy, International journal of radiation oncology, vol.76, issue.1, pp.277-286, 2010.

S. Vynckier, S. Derreumaux, F. Richard, A. Bol, C. Michel et al., Is it possible to verify directly a proton treatment plan using positron emission tomography ?, Radiotherapy and Oncology, vol.26, issue.3, pp.275-277, 1993.

C. Kurz, J. Bauer, M. Conti, L. Guérin, L. Eriksson et al., Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ionbeam therapy monitoring, Medical Physics, vol.42, issue.7, pp.3979-3991, 2015.

X. Zhu, S. España, J. Daartz, N. Liebsch, J. Ouyang et al., Monitoring proton radiation therapy with inroom PET imaging, Physics in medicine and biology, vol.56, issue.13, pp.4041-4057, 2011.

J. Bauer, D. Unholtz, F. Sommerer, C. Kurz, T. Haberer et al., Implementation and initial clinical experience of offline PET/CT-based verification of scanned carbon ion treatment, Radiotherapy and Oncology, vol.107, issue.2, pp.218-226, 2013.

H. Tashima, E. Yoshida, N. Inadama, F. Nishikido, Y. Nakajima et al., Development of a small single-ring OpenPET prototype with a novel transformable architecture, Physics in Medicine and Biology, vol.61, issue.4, p.148, 2016.

K. Grogg, N. M. Alpert, X. Zhu, C. H. Min, M. Testa et al., Mapping 15o production rate for proton therapy verification, International journal of radiation oncology, vol.92, issue.2, pp.453-459, 2015.

A. C. Kraan, S. Muraro, G. Battistoni, N. Belcari, M. G. Bisogni et al., Analysis of time-profiles with inbeam PET monitoring in charged particle therapy, Journal of Instrumentation, vol.14, issue.02, pp.2001-02001, 2019.

S. Vecchio, F. Attanasi, N. Belcari, M. Camarda, G. A. Cirrone et al., A PET Prototype for "In-Beam" Monitoring of Proton Therapy, IEEE Transactions on Nuclear Science, vol.56, issue.1, pp.51-56, 2009.

E. Fabbiani, N. Belcari, N. Camarlinghi, A. D. Guerra, S. Ferretti et al., Performance evaluation of a LYSO based PET scanner for monitoring of dose delivery in hadrontherapy, Journal of Instrumentation, vol.10, issue.12, pp.12029-12029, 2015.

V. Rosso, N. Belcari, M. G. Bisogni, N. Camarlinghi, G. A. Cirrone et al., DoPET an intreatment monitoring system for proton therapy at 62 MeV, Journal of Instrumentation, vol.11, issue.12, pp.12029-12029, 2016.

A. Topi, S. Muraro, G. Battistoni, N. Belcari, M. G. Bisogni et al., Monitoring Proton Therapy Through In-Beam PET : An Experimental Phantom Study, IEEE Transactions on Radiation and Plasma Medical Sciences, vol.62, p.63, 2019.

, Hamamatsu Photonics, 2019.

M. D. Rolo, R. Bugalho, F. Gonçalves, G. Mazza, A. Rivetti et al., TOF-PET ASIC for PET applications, Journal of Instrumentation, vol.8, issue.02, pp.2050-02050, 2013.

M. A. Piliero, F. Pennazio, M. G. Bisogni, N. Camarlinghi, P. G. Cerello et al., Fullbeam performances of a PET detector with synchrotron therapeutic proton beams, Physics in Medicine and Biology, vol.61, issue.23, pp.650-666, 2016.

P. L. Cambraia, J. Bauer, A. Salomon, I. Rinaldi, V. Tabacchini et al., First in situ TOF-PET study using digital photon counters for proton range verification, Physics in medicine and biology, vol.61, issue.16, p.64, 2016.

D. R. Schaart, E. Charbon, T. Frach, and V. Schulz, Advances in digital SiPMs and their application in biomedical imaging, vol.809, pp.31-52, 2016.

A. Knopf and A. Lomax, In vivo proton range verification : a review, Physics in Medicine and Biology, vol.58, issue.15, pp.131-160, 2013.

M. Fontana, Tests and characterization of gamma cameras for medical applications, phdthesis, 2018.

J. Krimmer, D. Dauvergne, J. Létang, and E. Testa, Prompt-gamma monitoring in hadrontherapy : A review, Nuclear Instruments and Methods in Physics Research Section A : Accelerators, vol.878, p.66, 2018.

A. C. Kraan, Range Verification Methods in Particle Therapy : Underlying Physics and Monte Carlo Modeling, Frontiers in Oncology, vol.5, 2015.

C. Agodi, F. Bellini, G. A. Cirrone, F. Collamati, G. Cuttone et al., Precise measurement of prompt photon emission from 80 MeV/u carbon ion beam irradiation, Journal of Instrumentation, vol.7, issue.03, pp.3001-03001, 2012.

J. C. Polf, D. Mackin, E. Lee, S. Avery, and S. Beddar, Detecting prompt gamma emission during proton therapy : the effects of detector size and distance from the patient, Physics in medicine and biology, vol.59, issue.9, pp.2325-2340, 2014.

L. and G. Manzano, Optimization of a single-phase liquid xenon Compton camera for 3? medical imaging, phdthesis, 2016.

T. Oger, Développement expérimental d'un télescope Compton au xenon liquide pour l'imagerie médicale fonctionnelle, phdthesis, 2012.

C. Lang, D. Habs, K. Parodi, and P. G. Thirolf, Submillimeter nuclear medical imaging with high sensitivity in positron emission tomography using beta+ gamma coincidences, Journal of Instrumentation, vol.9, issue.01, p.67, 2014.

T. Yamaya, E. Yoshida, H. Tashima, A. Tsuji, K. Nagatsu et al., Whole gamma imaging (WGI) concept: simulation study of triplegamma imaging, Journal of Nuclear Medicine, vol.58, issue.1, pp.152-152, 2017.

M. Marafini, A. Attili, G. Battistoni, N. Belcari, M. G. Bisogni et al., The INSIDE project : Innovative solutions for inbeam dosimetry in hadrontherapy, vol.127, pp.1465-1467, 2015.

V. Ferrero, The INSIDE project in beam PET scanner system features and characterization, Journal of Instrumentation, vol.12, issue.03, pp.3051-03051, 2017.

S. Lehrack, W. Assmann, D. Bertrand, S. Henrotin, J. Herault et al., Submillimeter ionoacoustic range determination for protons in water at a clinical synchrocyclotron, Physics in Medicine & Biology, vol.62, issue.17, pp.20-30, 2017.

K. Parodi and W. Assmann, Ionoacoustics A new direct method for range verification, Modern Physics Letters A, vol.30, issue.17, p.67, 2015.

B. Joly, Optimisation de la résolution temporelle en Tomographie par Emission de Positons dédiée au contrôle de dose en hadronthérapie., phdthesis, 2010.

L. Lestand, Etude de la mesure en ligne de l'activité beta+ induite lors des traitements d'hadronthérapie, 2012.

A. Rozes, Construction et premières caractérisations d'un détecteur dédié à la mesure de l'activité beta + induite lors des traitements d'hadronthérapie, en vue de leur contrôle balistique, phdthesis, 2016.

. Institut-méditerranéen-de-protonthérapie, , vol.18, p.76

M. The and . Programme,

F. Demard, P. Mandrillon, and . Dans-l'oeil-du-cyclotron--quand-la-haute-technologie-défie-le-cancer,

A. Courdi, J. P. Caujolle, J. D. Grange, L. Diallo-rosier, J. Sahel et al., Results of proton therapy of uveal melanomas treated in Nice, International Journal of Radiation Oncology, vol.45, issue.1, pp.5-11, 1999.

J. Caujolle, H. Mammar, E. Chamorey, F. Pinon, J. Herault et al., Proton beam radiotherapy for uveal melanomas at nice teaching hospital : 16 years' experience, International Journal of Radiation Oncology, vol.78, issue.1, pp.98-103, 2010.

J. Thariat, J. Grange, C. Mosci, L. Rosier, C. Maschi et al., Visual Outcomes of Parapapillary Uveal Melanomas Following Proton Beam Therapy, International Journal of Radiation Oncology, vol.95, issue.1, pp.328-335, 2016.

W. Kleeven, IBA Proton Therapy Systems, vol.55, p.78

F. Hadron--accueil,

, PreLude? 420 crystal Cerium doped Lutetium | Products | Saint-Gobain Crystals, p.144

R. Photomultiplier-tube and . Photonics,

. Drs-chip-home and . Page,

F. Cei, Status and perspectives of the MEG experiment, EPJ Web of Conferences, vol.118, p.1004, 2016.

I. Antcheva, M. Ballintijn, B. Bellenot, M. Biskup, R. Brun et al., ROOT -A C++ framework for petabyte data storage, statistical analysis and visualization, Computer Physics Communications, vol.180, issue.12, pp.2499-2512, 2009.

, The Go Programming Language

V. A. Pedroni, Circuit Design with VHDL, p.90, 2004.

M. Moreau, Introduction à l'imagerie par Tomographie d'Émission de Positons : définitions, approches de reconstruction et initiation aux isotopes complexes, 2019.

E. Parzen, On Estimation of a Probability Density Function and Mode, The Annals of Mathematical Statistics, vol.33, issue.3, p.92, 1962.

K. S. Cranmer, Kernel Estimation in High-Energy Physics, vol.136, pp.198-207, 2001.

G. Puech, Conception d'un ADC de résolution 8 bits basse consommation et 2 GHz de fréquence d'échantillonnage en technologie CMOS 180 nm, phdthesis, 2017.

C. Zerby, Monte Carlo calculation of the response of gamma-ray scintillation counters Methods in Computational Physics 1, Methods in Computational Physics, pp.89-134, 1963.

P. Andreo and A. Brahme, Restricted Energy-Loss Straggling and Multiple Scattering of Electrons in Mixed Monte Carlo Procedures, Radiation Research, vol.100, issue.1, p.110, 1984.

H. Zaidi, G. Sgouros, and G. Sgouros, The Monte Carlo method : theory and computational issues, 2002.

G. Robert, Brown's General Tools Page

M. Matsumoto, T. Nishimura, and M. Twister, A 623-dimensionally Equidistributed Uniform Pseudo-random Number Generator, ACM Trans. Model. Comput. Simul, vol.8, issue.1, pp.3-30, 1998.

J. F. Briesmeister, MCNP : A General Monte Carlo N-Particle Transport Code, p.110, 2000.

, MCNPX User's Manual, Version 2.7.0 | Request PDF

T. W. Laub, R. P. Kensek, B. C. Franke, and M. J. Crawford, ITS Version 6.4: The Integrated TIGER Series, SNL-NM), 2014.

S. M. Seltzer, Electron-photon Monte Carlo calculations : The ETRAN code, International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, vol.42, issue.10, pp.917-941, 1991.

G. Battistoni, J. Bauer, T. T. Boehlen, F. Cerutti, M. P. Chin et al., The FLUKA Code : An Accurate Simulation Tool for Particle Therapy, Front Oncol, vol.6, p.111, 2016.

S. Agostinelli, J. Allison, K. Amako, J. Apostolakis, H. Araujo et al.,

M. Pia, F. Ranjard, A. Rybin, S. Sadilov, E. D. Salvo et al., Geant4-a simulation toolkit, Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment, vol.506, issue.3, p.111, 2003.
URL : https://hal.archives-ouvertes.fr/in2p3-00020246

F. Salvat, J. M. Fernandez-varea, E. Acosta, and J. Sempau, Penelope -A code system for Monte Carlo simulation of electron and photon transport, 2001.

S. Incerti, I. Kyriakou, M. A. Bernal, M. C. Bordage, Z. Francis et al., Geant4-DNA example applications for track structure simulations in liquid water : A report from the Geant4-DNA Project, Medical Physics, vol.45, issue.8, pp.722-739, 2018.
URL : https://hal.archives-ouvertes.fr/hal-01885579

T. System-|-interna, Journal of Modeling, Simulation, and Scientific Computing, vol.111, p.152

L. L. Carter and E. D. Cashwell, Particle-transport simulation with the Monte Carlo method, 1975.

C. Suplee, Physical Reference Data, 2009.

, Physics Reference Manual, vol.354, p.119

T. Koi, Interfacing the JQMD and JAM Nuclear Reaction Codes to Geant4, vol.813352, 2003.

K. Niita, S. Chiba, T. Maruyama, T. Maruyama, H. Takada et al., Iwamoto, Analysis of the (N,xN') reactions by quantum molecular dynamics plus statistical decay model, Physical Review C, vol.52, issue.5, pp.2620-2635, 1995.

J. Apostolakis, M. Asai, A. G. Bogdanov, H. Burkhardt, G. Cosmo et al., Geometry and physics of the Geant4 toolkit for high and medium energy applications, Radiation Physics and Chemistry, vol.78, pp.859-873, 2009.

V. Lara, Pre-Equilibrium and Equilibrium decays in Geant4 39, vol.119, p.120

V. F. Weisskopf and D. H. Ewing, On the Yield of Nuclear Reactions with Heavy Elements, Physical Review, vol.57, issue.6, pp.472-485, 1940.

E. Bauge and S. Hilaire, Modélisation et Evaluation de Données 40, vol.120

, Evaluated and Compiled Nuclear Structure Data, p.121

. Bibliographie,

A. J. Koning, S. Hilaire, and M. C. Duijvestijn, TALYS : Comprehensive Nuclear Reaction Modeling, AIP Conference Proceedings, vol.769, issue.1, pp.1154-1159, 2005.

G. Folger, V. N. Ivanchenko, and J. P. Wellisch, The Binary Cascade, Eur. Phys. J. A, vol.21, issue.3, pp.407-417, 2004.

C. Divay, Etude de la fragmentation du carbone-12 pour la hadronthérapie, phdthesis, Normandie, 2017.

A. Koning and D. Rochman, Modern nuclear data evaluation with the talys code system, Nuclear Data Sheets, vol.113, issue.12, p.133, 2012.

K. Parodi, W. Enghardt, and T. Haberer, beam PET measurements of beta+ radioactivity induced by proton beams, vol.47, p.129, 2002.

P. Dendooven, H. J. Buitenhuis, F. Diblen, P. N. Heeres, A. K. Biegun et al., Short-lived positron emitters in beam-on PET imaging during proton therapy, Phys. Med. Biol, vol.60, issue.23, p.161, 2015.

T. Amin, A. Infantino, R. Barlow, and C. Hoehr, Validating production of PET radionuclides in solid and liquid targets : Comparing Geant4 predictions with FLUKA and measurements, Applied Radiation and Isotopes, vol.133, pp.61-67, 2018.

D. Chiappara, Preliminary modelling for the Proton Boron Capture Therapy (PBCT), 2019.

P. Dendooven, H. J. Buitenhuis, F. Diblen, P. N. Heeres, A. K. Biegun et al., Corrigendum : Short-lived positron emitters in beamon PET imaging during proton therapy, Physics in Medicine & Biology, vol.60, issue.8923, p.131, 2015.

D. Wright, T. Koi, G. Folger, V. Ivanchenko, M. Kossov et al., Low and high energy modeling in geant4, AIP Conf. Proc, vol.896, issue.1, pp.11-20, 2007.

N. Otuka, E. Dupont, V. Semkova, B. Pritychenko, A. Blokhin et al., Towards a more complete and accurate experimental nuclear reaction data library (exfor) : International collaboration between nuclear reaction data centres (nrdc), Nuclear Data Sheets, vol.120, p.139, 2014.

E. Rimmer and P. Fisher, Resonances in the (p, n) reaction on 12c, Nuclear Physics A, vol.108, issue.3, p.139, 1968.

P. Arce, J. I. Lagares, L. Harkness, D. Pérez-astudillo, M. Cañadas et al., Gamos : A framework to do geant4 simulations in different physics fields with an user-friendly interface, Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment, vol.735, pp.304-313, 2014.

. Hadronic-|-geant4,

G. Amadio, J. Apostolakis, M. Bandieramonte, A. Bhattacharyya, C. Bianchini et al., The GeantV project preparing the future of simulation, Journal of Physics : Conference Series, vol.664, issue.7, p.72006, 2015.

, Les événements simulés sont triés en fonction du temps de création du proton

, Le lot d'événements simulé est dupliqué jusqu'à obtenir le nombre de protons souhaité

, Pour éviter d'avoir un même motif, les temps d'annihilations de chacun des émetteurs ? + sont de nouveau tirés avec une loi exponentielle

, PreLude? 420 crystal Cerium doped Lutetium | Products | Saint-Gobain Crystals, p.144

. Pet/mri-·-rs2d,

H. Tashima, E. Yoshida, N. Inadama, F. Nishikido, Y. Nakajima et al., Development of a small single-ring OpenPET prototype with a novel transformable architecture, Physics in Medicine and Biology, vol.61, issue.4, p.148, 2016.

M. Hamonet, Tomographie hybride simultanée TEP/TDM combinant détecteurs à pixels hybrides et modules phoswich à scintillateurs, phdthesis, 2016.

, Geant4 Book For Application Developers -Book For Application Developers 10.4 documentation, vol.111, p.152

I. Pshenichnov, I. Mishustin, and W. Greiner, Distributions of positron emitting nuclei in proton and carbon ion therapy studied with GEANT4, Physics in Medicine and Biology, vol.51, issue.23, pp.6099-6112, 2006.

K. Parodi, A. Ferrari, F. Sommerer, and H. Paganetti, Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code, Physics in Medicine and Biology, vol.52, issue.12, pp.3369-3387, 2007.

K. Parodi, H. Paganetti, H. A. Shih, S. Michaud, J. S. Loeffler et al., Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton Therapy, International Journal of Radiation Oncology*Biology*Physics, vol.68, issue.3, pp.920-934, 2007.

F. Sommerer, F. Cerutti, K. Parodi, A. Ferrari, W. Enghardt et al., In beam PET monitoring of mono-energetic16o and12c beams : experiments and FLUKA simulations for homogeneous targets, Physics in Medicine and Biology, vol.54, issue.13, pp.3979-3996, 2009.

, 160 7.1.1 Principaux radioisotopes ? + produits lors de l'irradiation d'une cible de PMMA160 7.1.2 Taux de production et d'annihilation des différents émetteurs ? +

, Étude du profil d'activité ? + en fonction du temps

.. .. Bilan,

). .. Mev, 174 7.2.1 Principaux radioisotopes ? + produits lors de l'irradiation d'une cible de PMMA174 7.2.2 Taux de production et d'annihilation des différents émetteurs ? +, p.181

, Comparaison multi énergies pour les protons et perspectives pour l'optimisation de l'acquisition

. Chapitre-7, +. Étude-des-radioisotopes-?, and . De-l, IRRADIATION FIGURE 7.6 -Évolution du profil d'activité ? + en fonction du temps d'acquisition durant et après une irradiation d'une seconde en protons à 65 MeV d

. Chapitre-7, +. Étude-des-radioisotopes-?, and . De-l',

, 100 ms, 1 s, 10 s, 1 min et 10 min pour un temps d'irradiation d'une seconde. Cette figure montre que le profil change significativement en fonction du temps d'acquisition. En effet, lorsqu'on superpose les différents profils d'activité pour les 4 principaux émetteurs ? + (?, 12 N, 15 O et 11 C) qui composent principalement le profil, comme sur la figure 7.16, on s'aperçoit que chacun des émetteurs possède un profil différent, La figure 7.15 représente le profil d'activité ? + pour différents temps d'acquisition : 1 ms

, Alors que l' 15 O et le 11 C présentent des profils similaires avec un front distal marqué

, En effet on constate que l'énergie cinétique moyenne des protons diminue tout au long de leur parcours jusqu'à atteindre une valeur inférieure aux énergies de seuil des réactions nucléaires. Cependant dans le cadre d'un contrôle en ligne qui vise à déterminer la position du pic de Bragg ou au moins le décalage correspondant à différentes énergies, on doit tenir compte de cette variation du profil d'activité selon le temps d'acquisition utilisé. De plus, les isotopes qui contribuent le plus aux petits temps (essentiellement 12 N ) présentent un profil a priori plus « difficile » à analyser que ceux qui contribuent à grand temps ( 15 O, 11 C). On note également que malgré la faible production de certains émetteurs, Ces différences s'expliquent par les différentes énergies de seuil des réactions nucléaires ainsi que par le parcours moyen du ? + dans le cas des ? pr ompt s et du 12 N (voir tableau 7.1)

, De la même manière qu'à 65 MeV, on note une présence marquée du 10 C et de l' 14 O, émetteurs

, Bilan de l'étude de la production d'isotopes lors d'une irradiation d'une cible de PMMA avec des protons de 120 et 220 MeV

, Ainsi nous avons pu voir que 4 émetteurs sont fortement représentés : ? pr ompt s , 12 N, 15 O et

C. , Ces émetteurs aux caractéristiques très différentes à la fois en termes de période, de taux de production et de parcours moyen du ? + émis influent chacun à leur tour sur le profil d'activité. Toutefois en synchronisant l'acquisition sur les temps de pause du faisceau il est possible d'obtenir un profil ? + très pur en 12 N

M. Conti and L. Eriksson, Physics of pure and non-pure positron emitters for PET : a review and a discussion, EJNMMI Physics, vol.3, p.161, 2016.

C. S. Levin and E. J. Hoffman, Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution, Physics in Medicine and Biology, vol.44, issue.3, p.161, 1999.

O. Humbert, Imagerie TEP au 18f-FDG du cancer du sein : étude du comportement métabolique des différents phénotypes tumoraux et prédiction de la réponse tumorale à la chimiothérapie néoadjuvante, 2015.

P. Dendooven, H. J. Buitenhuis, F. Diblen, P. N. Heeres, A. K. Biegun et al., Short-lived positron emitters in beam-on PET imaging during proton therapy, Physics in Medicine and Biology, vol.60, issue.23, p.161, 2015.

I. Perali, A. Celani, L. Bombelli, C. Fiorini, F. Camera et al., Prompt gamma imaging of proton pencil beams at clinical dose rate, Physics in Medicine and Biology, vol.59, issue.19, pp.5849-5871, 2014.
URL : https://hal.archives-ouvertes.fr/hal-02066358

L. K. Shankar, J. M. Hoffman, S. Bacharach, M. M. Graham, J. Karp et al., National Cancer Institute, Consensus recommendations for the use of 18f-FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials, Journal of Nuclear Medicine, vol.47, issue.6, p.164, 2006.

C. Divay, Etude de la fragmentation du ¹²C pour la hadronthérapie, 2017.

Q. Calculator,

L. and G. Manzano, Optimization of a single-phase liquid xenon Compton camera for 3? medical imaging, phdthesis, 2016.

H. J. Buitenhuis, F. Diblen, K. W. Brzezinski, S. Brandenburg, and P. Dendooven, Beam-on imaging of short-lived positron emitters during proton therapy, Physics in Medicine and Biology, vol.62, issue.12, pp.4654-4672, 2017.

, des événements simulés pour lesquels il y a eu une annihilation à l'extérieur de la cible

, Les ? + qui s'échappent de la cible et qui peuvent s'annihiler dans le détecteur et être détectés en coïncidence temporelle puisque la résolution temporelle du DPGA ne permet pas de les discriminer

, Si ce cas de figure concerne essentiellement les ? pr ompt s et les émetteurs 3?, il peut également, dans une moindre mesure, être dû au phénomène du rayonnement de freinage

. Enfin, dans de très rares cas l'annihilation peut avoir lieu dans l'air avant que le positon ait perdu toute son énergie

, 16 -Profils d'activités ? + reconstruits avec l'algorithme MA lors d'une irradiation de cibles de PMMA homogènes avec le faisceau de protons Medicyc dans, FIGURE 8

, 17 -Différences entre les décalages reconstruits et réels en fonction de la position de la cible de PMMA homogène lors d'une irradiation avec le faisceau de protons Medicyc, FIGURE 8

, 18 -Illustration de l'effet de l'acceptance sur la forme du profil. Pour une cible située dans la partie gauche, l'acceptance sera la plus élevée au niveau du fall-off alors qu'elle sera la moins élevée pour une cible située dans la partie droite, FIGURE 8

, FIGURE 8.19 -Biais de reconstruction obtenus à partir de différents paramètres de lissage dans tout le champ de vue du DPGA après une irradiation de 15 minutes en protons à 65 MeV dans une cible de PMMA

, Étude de l'effet du temps d'acquisition sur la valeur du biais Lorsqu'on observe sur la figure 8.20 l'évolution du biais en fonction du temps d'acquisition, on constate que la valeur absolue du biais diminue rapidement, puis se stabilise autour d'une valeur moyenne lorsque la statistique est suffisante

, L'amplitude des variations autour de cette valeur moyenne (au-delà d'environ dix minutes), donne une idée de l'incertitude obtenue sur la mesure de ce biais

, avons pas cherché à obtenir une mesure de l'erreur associée au biais de mesure. Néanmoins on peut observer qu'entre 7 et 15 minutes, le biais oscille avec une amplitude de ±0,1 mm au centre du détecteur, ±0,2 mm ailleurs. Il est important de garder à l'esprit que pour, des temps cliniques, le profil reconstruit est composé de plusieurs émetteurs ? + ayant chacun une valeur de biais différente

K. Kossert, G. Jörg, and C. L. Gostomski, Experimental half-life determination of 176lu, Applied Radiation and Isotopes, vol.81, pp.140-145, 2013.

B. Joly, Optimisation de la résolution temporelle en tomographie par émission de positons dédiée au contrôle de dose en hadronthérapie, phdthesis, 2010.

G. Audit, N. De-botton, G. Le-poitevin, C. Schuhl, and G. Tamas, Sources de photons obtenus par annihilation en vol de positons, vol.4, pp.293-294, 1969.
URL : https://hal.archives-ouvertes.fr/jpa-00243267

S. Srivastava and C. Suresh, Paving the way to personalized medicine : production of some promising theragnostic radionuclides at Brookhaven National Laboratory, Seminars in Nuclear Medicine, vol.42, issue.3, pp.151-163, 2012.

C. C. Martin, B. T. Christian, M. R. Satter, L. H. Nickerson, and R. J. Nickles, Quantitative PET with positron emitters that emit prompt gamma rays, IEEE transactions on medical imaging, vol.14, issue.4, pp.681-687, 1995.

M. Lubberink, H. Schneider, M. B. .-m, and H. Lundqvist, Quantitative imaging and correction for cascade gamma radiation of76br with 2d and 3d PET, Physics in Medicine and Biology, vol.47, issue.19, pp.3519-3534, 2002.

K. Pentlow, R. Finn, S. Larson, Y. Erdi, B. Beattie et al., Quantitative Imaging of Yttrium-86 with PET. The Occurrence and Correction of Anomalous Apparent Activity in High Density Regions, Clinical Positron Imaging : Official Journal of the Institute for Clinical P.E.T, vol.3, issue.3, pp.85-90, 2000.

M. Moreau, Introduction à l'imagerie par Tomographie d'Émission de Positons : définitions, approches de reconstruction et initiation aux isotopes complexes, 2019.

, Au cours du chapitre précédent nous avons évalué expérimentalement la capacité du système DPGA à mesurer les variations de la position du pic de Bragg pendant l'irradiation. De plus, par simulation, nous avons pu reproduire avec un bon accord ces résultats expérimentaux

, Comme le système d'acquisition utilisé pour l'expérience est limité par le temps mort provenant du transfert de données via le fond de panier VME, nous avons cherché à évaluer par simulation les performances du système DPGA pour les futures expérimentations sur la ligne 230 MeV (PROTEUS ® ONE) avec un système µTCA

. .. Procédure-expérimentale, 2.2 Analyse complémentaire des résultats obtenus par simulation pour la position de référence

, Étude de l'effet du paramètre de lissage sur la mesure du biais, p.229

, Étude de l'effet du temps d'acquisition sur la valeur du biais, p.229

.. .. Mev, Analyse complémentaire des résultats obtenus par simulation pour la position de référence

, Étude de l'efficacité des sélections appliquées aux événements simulés, p.235

, Étude de l'effet du paramètre de lissage sur la mesure du biais, p.238

, Étude de l'effet du temps d'acquisition sur la valeur du biais, p.238

. .. Conclusion, 241 -La géométrie simulée comprend les principaux éléments : 1. Une simulation complète des six modules du DPGA

, Une cible de PMMA de 5 x 5 x 10 cm 3

, Un environnement qui reproduit la composition de l'atmosphère terrestre

. -le-modèle-hadronique-utilisé-est-le-g4hadronphysicsqgsp_bic,

, -La source simulée est un faisceau de protons de 120 MeV placé avant le DPGA (z = -170 mm)

, Les paramètres de la structure temporelle qui sont utilisés pour la simulation du faisceau sont disponibles à la section 6.1.3. À 120 MeV, le nombre de protons par bunch simulé est de 5312 et correspond à un taux de

, mis en évidence que compte tenu de leurs demi-vies, la proportion relative des éléments évoluait

. C'est-ce-que-l'on-retrouve and . Lorsqu, on observe la composition isotopique du profil discret présent sur la figure 9.3, pour une acquisition de : -1 seconde (figure 9.3a) : le profil discret est quasi-exclusivement composé d, vol.94, p.6

, Le deuxième contributeur est l'oxygène-15 qui représente moins de 3%. Le profil reconstruit est donc fortement corrélé à celui de l'azote-12 et apparaît donc peu résolu dans sa partie distale

, 3b) : l'azote-12 reste l'élément majoritaire (74,1 %) mais la proportion des éléments minoritaires n'est plus négligeable puisque l'oxygène-15 représente plus de 15%. Le carbone-10 et carbone-11 représentent respectivement 4, -10 secondes

. Cependant, azote-12 soit toujours fortement majoritaire, on observe que la forme du profil reconstruit est largement influencée par les éléments minoritaires. Le profil apparait en effet mieux résolu sur sa partie distale. En effet, pour passer de 80% à 20% du maximum de la partie distale du profil reconstruit, on mesure 18,1 mm

, 3c) : si l'azote-12 reste encore l'élément majoritaire (52,7 %), l'oxygène-15 représente plus de 30% et le carbone-10 et carbone-11 représentent alors respectivement 7,0% et 6,2%. La forme du profil reconstruit est fortement influencée par les éléments minoritaires, -30 secondes

, Étant donné le manque de mesures expérimentales pour les hautes énergies, il apparait difficile de corriger précisément les taux de production des émetteurs ? + . Néanmoins, pour une cible placée à la position de référence (où le pic de Bragg se situe au centre du champ de vue), la majorité des ? + est acquise dans une zone proche du centre de champ de vue. Ces ? + proviennent donc de réaction ayant eu lieu essentiellement un peu avant le pic de Bragg, comme pour des faisceaux de relativement basse énergie. Dès lors par comparaison avec le faisceau de 55 MeV, on peut penser que l'influence des éléments minoritaires est bien plus élevée puisqu'à 55 MeV, le taux de production de l'azote-12 est fortement surestimé. Comme il apparait que les éléments minoritaires permettent d'obtenir un profil reconstruit mieux résolu et donc une valeur de biais réduite, on peut penser que les valeurs de biais présentées dans la section précédente sont probablement surestimées, Compte tenu des différences de taux de production observées entre les mesures expérimentales et celles obtenues par simulation d'un faisceau de protons 55 MeV (voir chapitre 5)

, 5 le profil discret et le profil d'activité ? + « vrai » obtenu à partir des positons annihilés dans la cible, pour les quatre principaux émetteurs ? + qui composent le profil discret. Les profils de chacun des émetteurs sont obtenus pour la position de référence et pour des acquisitions de 1, 10 et 30 secondes, Pour comprendre l'influence de chacun des isotopes sur le profil reconstruit en fonction du temps, nous avons représenté sur les figures 9, vol.4

, on observe que si la partie distale du profil discret de l'azote-12 est finalement déjà très proche de celle du profil d'activité vrai, ce n'est pas le cas des autres émetteurs ? + qui présentent une faible statistique

, 4 e,f,g et h), l'oxygène-15, le carbone-10 et, dans une moindre mesure, le carbone-11 présentent une partie distale de leur profil discret très proche de celle du profil d'activité vrai. Ainsi c'est donc l'apport de ces profils discrets mieux résolus qui, En revanche pour un temps d'acquisition de dix seconde

, En effet, mise à part la cible de PMMA dont la taille a été ajustée (5 x 5 x 28 cm 3 ), la source qui été repositionnée de manière à ne pas être superposée avec la cible (z = -300 mm) et le taux de transmission du faisceau à l'isocentre ajusté à 6,2% (21955 protons / bunch), les autres paramètres sont identiques. Toutefois on peut noter que ce cas présente deux spécificités, la simulation du faisceau de protons de 220 MeV diffère peu de la simulation du faisceau de protons de 120 MeV

, En effet, comme la cible est plus grande que le champ de vue du DPGA, la majeure partie de la cible se trouve à l'extérieur du DPGA lorsque la cible est positionnée à sa position de référence

, 9 -Irradiation d'une cible de PMMA par un faisceau de protons de 220 MeV avec Geant4. Le pic de Bragg est placé au centre du champ de vue du DPGA. Les protons sont représentés en bleu, les gamma en vert, les électrons en rouge, FIGURE 9

, il est en proportion plus faible par voxel puisque l'activité ? + se répartit dans toute la cible. D'un point de vue technique, cette simulation a donc été un important défi car elle nécessite une statistique importante pour que la méthode de duplication de données produise un résultat satisfaisant. Pour pouvoir obtenir des résultats dans des temps raisonnables tout en simulant une statistique suffisante, chaque simulation d'une position de cible a été fractionnée en 250 simulations indépendantes de 30 millions de protons, Si le taux de production des éléments ? + à 220 MeV est bien plus élevé qu'à 120 MeV

É. De and . Énergie, Néanmoins l'écart entre les parties distales des profils n'apparait régulier qu'à partir de 10 secondes d'acquisition pour les profils situés autour du centre du champ de vue et pour 30 secondes au-delà. La figure 9.11 montre que les décalages mesurés par reconstruction évoluent fortement en fonction du temps d'acquisition. On observe qu'avec un temps d'acquisition d'une seconde, le CHAPITRE 9, Les profils d'activités ont été reconstruits pour sept positions de cibles

, 12 -Profil reconstruit et profil discret, obtenus après une irradiation de 1, 10 et 30 secondes en, FIGURE 9

, En effet, comme actuellement l'irradiation d'une tumeur avec un SOBP commence par la tranche de plus haute énergie, pour aller ensuite vers les énergies les plus faibles, nous pouvons légitiment nous demander si la mesure de l'activité ? + engendrée par un faisceau de basse énergie sera « perturbée

, Enfin à plus long terme, des études sur des cibles inhomogènes et plus généralement des fantômes anthropomorphiques devront être envisagées