Quantitative x-ray tomography, International materials reviews, vol.59, issue.1, pp.1-43, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01538208
3d imaging in material science: Application of x-ray tomography, Comptes Rendus Physique, vol.11, issue.9, pp.641-649, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00569350
Electron tomography: A threedimensional analytic tool for hard and soft materials research, Advanced Materials, vol.27, issue.38, pp.5638-5663, 2015. ,
3d static elastography at the micrometer scale using full field oct, Biomedical optics express, vol.4, issue.10, pp.2138-2149, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-01709281
Fast microtomography using high energy synchrotron radiation, Review of Scientific Instruments, vol.76, issue.4, p.43702, 2005. ,
Ultra fast in situ x-ray micro-tomography: Application to solidification of aluminium alloys, Materials science forum, vol.706, pp.1713-1718, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00697673
20 hz x-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1, pp.3-12, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01538199
4-d imaging of sub-second dynamics in pore-scale processes using real-time synchrotron x-ray tomography, Solid Earth, vol.7, issue.4, p.1059, 2016. ,
Time resolved x-ray dark-field tomography revealing water transport in a fresh cement sample, Scientific reports, vol.6, p.29108, 2016. ,
Metamorphosis revealed: time-lapse three-dimensional imaging inside a living chrysalis, Journal of the Royal Society Interface, vol.10, issue.84, p.20130304, 2013. ,
Lithiation-induced dilation mapping in a lithium-ion battery electrode by 3d x-ray microscopy and digital volume correlation, Advanced Energy Materials, vol.4, issue.4, 2014. ,
Efficient binary tomographic reconstruction, vol.49, pp.335-351, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01003479
Dart: a practical reconstruction algorithm for discrete tomography, IEEE Transactions on Image Processing, vol.20, issue.9, pp.2542-2553, 2011. ,
Beam-hardening in simulated x-ray tomography, NDT & E International, vol.39, issue.6, pp.449-457, 2006. ,
Reducing non-linear artifacts of multimaterial objects in industrial 3d computed tomography, Ndt & E International, vol.41, issue.4, pp.242-251, 2008. ,
Noise suppression methods in beam hardening correction for x-ray computed tomography, CISP'09. 2nd International Congress on, pp.1-5, 2009. ,
Correction for beam hardening in computed tomography, Physics in Medicine & Biology, vol.24, issue.1, p.81, 1979. ,
The ID23-2 structural biology microfocus beamline at the ESRF, Journal of synchrotron radiation, vol.17, issue.1, pp.107-118, 2010. ,
Separation of superimposed images with subpixel shift, Journal of synchrotron radiation, vol.25, issue.1, pp.272-281, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01674341
Fast x-ray tomography analysis of bubble growth and foam setting during breadmaking, Journal of Cereal Science, vol.43, issue.3, pp.393-397, 2006. ,
URL : https://hal.archives-ouvertes.fr/hal-00141792
In situ and real-time 3-d microtomography investigation of dendritic solidification in an al-10 wt.% cu alloy, Acta Materialia, vol.57, issue.7, pp.2300-2310, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-00378057
Observations of damage development from compression-after-impact experiments using ex situ micro-focus computed tomography, Composites Science and Technology, vol.97, pp.106-114, 2014. ,
In-situ synchrotron x-ray microtomography studies of microstructure and damage evolution in engineering materials, Advanced Engineering Materials, vol.9, issue.11, pp.939-950, 2007. ,
Direct observation of crack opening as a function of applied load in the interior of a notched tensile sample of al li 2090, Acta materialia, vol.45, issue.5, pp.1977-1987, 1997. ,
Repeated crack healing in max-phase ceramics revealed by 4d in situ synchrotron x-ray tomographic microscopy, Scientific reports, vol.6, p.23040, 2016. ,
In-situ x-ray tomography observation of structure evolution in 1, 3, 5-triamino-2, 4, 6-trinitrobenzene based polymer bonded explosive (tatb-pbx) under thermo-mechanical loading, Materials, vol.11, issue.5, 2018. ,
High-speed neutron tomography of fluid flow through rocks, 2018. ,
Quantifying interparticle forces and heterogeneity in 3d granular materials, Physical review letters, vol.117, issue.9, p.98005, 2016. ,
Force measurements in stiff, 3d, opaque granular materials, EPJ Web of Conferences, vol.140, p.2006, 2017. ,
Characterization of the bone-metal implant interface by digital volume correlation of in-situ loading using neutron tomography, Journal of the mechanical behavior of biomedical materials, vol.75, pp.271-278, 2017. ,
In situ experiments with x ray tomography: an attractive tool for experimental mechanics, Experimental mechanics, vol.50, issue.3, pp.289-305, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-01538062
Damage law identification from full field displacement measurement: Application to fourpoint bending test for plasterboard, European Journal of Mechanics-A/Solids, vol.49, pp.60-66, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01068546
Principles of computerized tomographic imaging, 1988. ,
A geometric calibration method for cone beam ct systems, Medical physics, vol.33, issue.6Part1, pp.1695-1706, 2006. ,
Towards geometrical calibration of x-ray computed tomography systems-a review, Measurement Science and Technology, vol.26, issue.9, p.92003, 2015. ,
Ct for industrial metrology-accuracy and structural resolution of ct dimensional measurements, Conference on Industrial Computed Tomography (ICT), 2012. ,
An optimization-based method for geometrical calibration in cone-beam ct without dedicated phantoms, Physics in Medicine & Biology, vol.53, issue.14, p.3841, 2008. ,
Automatic alignment for threedimensional tomographic reconstruction, Inverse Problems, vol.34, issue.2, p.24004, 2018. ,
´ Etude experimentale de l'´ evolution de la microstructure d'un milieu granulaire sous chargement mécanique a l'aide de la tomographie rayons x, 2013. ,
Accurate technique for complete geometric calibration of cone-beam computed tomography systems, Medical physics, vol.32, issue.4, pp.968-983, 2005. ,
A geometric calibration method for cone beam ct systems, Medical physics, vol.33, issue.6Part1, pp.1695-1706, 2006. ,
DOI : 10.1118/1.2198187
URL : http://europepmc.org/articles/pmc2840998?pdf=render
The astra toolbox: A platform for advanced algorithm development in electron tomography, Ultramicroscopy, vol.157, pp.35-47, 2015. ,
Practical cone-beam algorithm, JOSA A, vol.1, issue.6, pp.612-619, 1984. ,
DOI : 10.1364/josaa.1.000612
Algebraic reconstruction techniques (art) for three-dimensional electron microscopy and x-ray photography, Journal of theoretical Biology, vol.29, issue.3, pp.471-481, 1970. ,
Simultaneous algebraic reconstruction technique (sart): a superior implementation of the art algorithm, Ultrasonic imaging, vol.6, issue.1, pp.81-94, 1984. ,
Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information, IEEE Transactions on information theory, vol.52, issue.2, pp.489-509, 2006. ,
Low-dose x-ray ct reconstruction via dictionary learning, IEEE Transactions on Medical Imaging, vol.31, issue.9, pp.1682-1697, 2012. ,
Deformation analysis of gellan-gum based bone scaffold using on-the-fly tomography, Materials & Design, vol.134, pp.400-417, 2017. ,
Evaluation of measurement uncertainties of digital volume correlation applied to laminography data, The Journal of Strain Analysis for Engineering Design, p.0309324717748097, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01674568
3d mechanical analysis of low-density wood-based fiberboards by x-ray microcomputed tomography and digital volume correlation, Journal of Materials Science, vol.48, issue.8, pp.3198-3212, 2013. ,
Siviour. 3d deformation and strain analysis in compacted sugar using x-ray microtomography and digital volume correlation, Measurement Science and Technology, vol.20, issue.9, p.95703, 2009. ,
Internal deformation measurement of polymer bonded sugar in compression by digital volume correlation of in-situ tomography, Experimental Mechanics, vol.55, issue.1, 2015. ,
Digital volume correlation: Review of progress and challenges, Experimental Mechanics, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01744752
Digital volume correlation including rotational degrees of freedom during minimization, Experimental Mechanics, vol.42, issue.3, pp.272-278, 2002. ,
Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l'analyse des matériaux et des structures, Instrumentation, vol.4, issue.3-4, pp.43-88, 2004. ,
Three-dimensional image correlation from x-ray computed tomography of solid foam, Composites Part A: Applied science and manufacturing, vol.39, issue.8, pp.1253-1265, 2008. ,
URL : https://hal.archives-ouvertes.fr/hal-00198126
Extended threedimensional digital image correlation (x3d-dic), Comptes Rendus Mécanique, vol.336, issue.8, pp.643-649, 2008. ,
Synchrotron-radiation computed laminography for high-resolution three-dimensional imaging of flat devices, Physica Status Solidi, vol.204, issue.8, pp.2760-2765, 2007. ,
Extraction of "topological differences" on woven composite materials, 7th Conference on Industrial Computed Tomography, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01929560
Solutions of ill-posed problems, 1978. ,
A method for the solution of certain non-linear problems in least squares, Quarterly of applied mathematics, vol.2, issue.2, pp.164-168, 1944. ,
Voxel-scale digital volume correlation, Experimental Mechanics, vol.51, issue.4, pp.479-490, 2011. ,
DOI : 10.1007/s11340-010-9407-6
URL : https://hal.archives-ouvertes.fr/hal-00521193
A novel model-based evolutionary algorithm for multi-objective deformable image registration with content mismatch and large deformations: benchmarking efficiency and quality, International Society for Optics and Photonics, vol.10133, p.1013312, 2017. ,
Finite element applications in the characterization of elastic solids, International Journal of Solids and Structures, vol.7, pp.11-23, 1971. ,
Extension of classical experimental techniques for characterizing composite-material behavior, Experimental Mechanics, vol.12, issue.1, pp.50-56, 1972. ,
Statistical identification of structures, AIAA Journal, vol.12, issue.2, pp.185-190, 1974. ,
Identification of a set of macroscopic elastic parameters in a 3d woven composite: Uncertainty analysis and regularization, International Journal of Solids and Structures, vol.55, pp.2-16, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166765
Estimation of elastoplastic parameters via weighted femu and integrated-dic, Experimental Mechanics, vol.55, issue.1, pp.105-119, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166755
Big data in experimental mechanics and model order reduction: Today's challenges and tomorrow's opportunities. Archives of, Computational Methods in Engineering, vol.25, issue.1, pp.143-164, 2018. ,
Identification paramétrique par recalage de modèlesmodèleséléments finis coupléecoupléè a des mesures de champs cinématiques et thermiques, 2010. ,
Contribution of heterogeneous strain field measurements and boundary conditions modelling in inverse identification of material parameters, European Journal of Mechanics-A/Solids, vol.30, issue.3, pp.373-382, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-02004609
Optimization of a cruciform specimen geometry for the identification of constitutive parameters based upon full-field measurements, Strain, vol.52, issue.4, pp.307-323, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01383975
Full-field measurements of strain localisation in sandstone by neutron tomography and 3d-volumetric digital image correlation, Physics Procedia, vol.69, pp.509-515, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01965839
Analyse de la tenue mécanique d'un liner en titane: apport des mesures de champs cinématiques, 2013. ,
Digital image correlation and fracture: an advanced technique for estimating stress intensity factors of 2d and 3d cracks, Journal of Physics D: Applied Physics, vol.42, issue.21, p.214004, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-00381646
Dic identification and x-fem simulation of fatigue crack growth based on the williams' series, International Journal of Solids and Structures, vol.53, pp.38-47, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01710062
Automatic crack tip detection and stress intensity factors estimation of curved cracks from digital images, International Journal for Numerical Methods in Engineering, vol.103, issue.7, pp.516-534, 2015. ,
Extraction of stress intensity factors for 3d small fatigue cracks using digital volume correlation and x-ray tomography, International Journal of Fatigue, vol.71, pp.3-10, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01537225
Improving full-field identification using progressive model enrichments, International Journal of Solids and Structures, vol.118, pp.213-223, 2017. ,
DOI : 10.1016/j.ijsolstr.2017.03.013
URL : https://hal.archives-ouvertes.fr/hal-01549237
Projection savings in ct-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
Développement de la tomographie spatio-temporelle pour le suivi d'essais mécaniques, 2016. ,
Soft route to 4d tomography, Physical review letters, vol.117, issue.2, p.25501, 2016. ,
Measurement of 3d displacement fields from few tomographic projections, Optics, Photonics and Digital Technologies for Imaging Applications IV, vol.9896, p.98960, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01800794
Cad-based displacement measurements with stereo-dic, Experimental Mechanics, vol.55, issue.9, pp.1657-1668, 2015. ,
DOI : 10.1007/s11340-015-0065-6
URL : https://hal.archives-ouvertes.fr/hal-01198947
Finite element stereo digital image correlation: framework and mechanical regularization, Experimental Mechanics, vol.57, issue.3, pp.443-456, 2017. ,
Tracking and modelling small motions at grain scale in granular materials under compression by X-Ray microtomography and discrete simulations, 2016. ,
URL : https://hal.archives-ouvertes.fr/tel-01547810
Discrete digital projections correlation: a reconstruction-free method to quantify local kinematics in granular media by x-ray tomography, Experimental Mechanics, vol.57, issue.6, pp.819-830, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01474701
A review of 3d/2d registration methods for image-guided interventions, Medical image analysis, vol.16, issue.3, pp.642-661, 2012. ,
Respiratory motion estimation from slowly rotating x-ray projections: Theory and simulation, Medical physics, vol.32, issue.4, pp.984-991, 2005. ,
Estimating 3-d respiratory motion from orbiting views by tomographic image registration, IEEE Transactions on Medical Imaging, vol.26, issue.2, pp.153-163, 2007. ,
DOI : 10.1109/tmi.2006.889719
URL : https://deepblue.lib.umich.edu/bitstream/2027.42/85995/1/Fessler38.pdf
Selfcalibration of cone-beam ct geometry using 3d-2d image registration, Physics in Medicine & Biology, vol.61, issue.7, p.2613, 2016. ,
Automatic localization of vertebral levels in xray fluoroscopy using 3d-2d registration: a tool to reduce wrong-site surgery, Physics in Medicine & Biology, vol.57, issue.17, p.5485, 2012. ,
Enhanced 4d cone-beam ct with inter-phase motion model, Medical physics, vol.34, issue.9, pp.3688-3695, 2007. ,
Recalage déformable de projections de scanner X ` a faisceau conique, 2013. ,
In-room breathing motion estimation from limited projection views using a sliding deformation model, Journal of Physics: Conference Series, vol.489, p.12026, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-00847368
Projection-based motion estimation for cardiac functional analysis with high temporal resolution: a proof-of-concept study with digital phantom experiment, International Society for Optics and Photonics, vol.10132, p.1013230, 2017. ,
Real-time 2d/3d registration via cnn regression, IEEE 13th International Symposium on, pp.1430-1434, 2016. ,
3d/2d model-to-image registration by imitation learning for cardiac procedures, International journal of computer assisted radiology and surgery, pp.1-9, 2018. ,
In situµ ct-scan mechanical tests: Fast 4d mechanical identification, Experimental Mechanics, vol.57, issue.8, pp.1327-1340, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01576727
Fast 4d tensile test monitored via x-ct: Single projection based digital volume correlation dedicated to slender samples. submitted, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01847191
Fast 4d tensile test monitored via x-ct: Elastoplastic identification from radiographs. submitted, 2018. ,
Fast tracking of fluid invasion using time-resolved neutron tomography, Transport in Porous Media, pp.1-19, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01800787
Self-calibration for lab-µct using space-time regularized projection-based dvc and model reduction, Measurement Science and Technology, vol.29, issue.2, p.24003, 2018. ,
Dynamic tomography of moving samples. submitted, 2018. ,
Direct observation of crack opening as a function of applied load in the interior of a notched tensile sample of AlLi 2090, Acta materialia, vol.45, issue.5, pp.1977-1987, 1997. ,
, Situ Synchrotron X-Ray Microtomography Studies of Microstructure and Damage Evolution in Engineering Materials, vol.9, pp.939-950, 2007.
Quantitative X-ray tomography, International materials reviews, vol.59, issue.1, pp.1-43, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01538208
In situ observation of ductile fracture using X-ray tomography technique, Acta Materialia, vol.59, issue.5, 1995. ,
URL : https://hal.archives-ouvertes.fr/hal-01538235
Real-time image-content-based beamline control for smart 4D X-ray imaging, Journal of Synchrotron Radiation, vol.23, issue.5, pp.1254-1263, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01421577
In-situ three-dimensional microstructural investigation of solidification of an Al-Cu alloy by ultrafast X-ray microtomography, Metallurgical and Materials Transactions A, vol.36, issue.6, pp.1515-1523, 2005. ,
URL : https://hal.archives-ouvertes.fr/hal-00141318
Development of fast and high throughput tomography using CMOS image detector at SPring-8, 2012. ,
20 Hz X-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1, pp.3-12, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01538199
Digital volume correlation: three-dimensional strain mapping using X-ray tomography, Experimental mechanics, vol.39, issue.3, pp.217-226, 1999. ,
Digital volume correlation including rotational degrees of freedom during minimization, Experimental Mechanics, vol.42, issue.3, pp.272-278, 2002. ,
Toward 4D Mechanical Correlation, Advanced Modeling and Simulation in Engineering Sciences, vol.3, issue.1, p.17, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01310582
Time resolved Xray Dark-Field Tomography Revealing Water Transport in a Fresh Cement Sample, Scientific Reports, vol.6, 2016. ,
Communication-Effect of Micro-XCT X-ray Exposure on the Performance of Polymer Electrolyte Fuel Cells, Journal of The Electrochemical Society, vol.163, issue.10, pp.1206-1208, 2016. ,
Andrich. A test device for damage characterisation of composites based on in situ computed tomography, Composites Science and Technology, vol.72, issue.12, pp.1361-1367, 2012. ,
Three-dimensional fatigue crack growth behavior in an aluminum alloy investigated with in situ high-resolution synchrotron X-ray microtomography, Acta Materialia, vol.57, issue.11, pp.3287-3300, 2009. ,
Effects of synchrotron radiation on fuel cell materials, Journal of The Electrochemical Society, vol.159, issue.8, pp.449-455, 2012. ,
Projection savings in CT-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
Measurement of 3D displacement fields from few tomographic projections, SPIE Photonics Europe, page 98960. International Society for Optics and Photonics, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01800794
A soft route toward 4D tomography, Physical Review Letters, vol.117, issue.2, p.25501, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01383970
Tracking and modeling small motions at grain scale in granular materials under compression by X-Ray microtomography and discrete simulations, 2016. ,
Three-dimensional image correlation from X-ray computed tomography of solid foam, Composites Part A: Applied science and manufacturing, vol.39, issue.8, pp.1253-1265, 2008. ,
URL : https://hal.archives-ouvertes.fr/hal-01006730
Localized strain field measurement on laminography data with mechanical regularization, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.324, pp.70-79, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-00956440
Estimation of Elastoplastic Parameters via Weighted FEMU and Integrated-DIC, Experimental Mechanics, vol.55, issue.1, pp.105-119, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166755
Integrated digital image correlation applied to elasto-plastic identification in a biaxial experiment, Journal of Strain Analysis for Engineering Design, vol.51, issue.2, pp.118-131, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01303519
A space-time approach in digital image correlation: Movie-DIC, Optics and Lasers in Engineering, vol.49, issue.1, pp.71-81, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521203
Specimen for fracture mechanics studies on glass, Revue de Physique Appliquée, vol.12, issue.5, pp.803-803, 1977. ,
URL : https://hal.archives-ouvertes.fr/jpa-00244244
Glass breaks like metal, but at the nanometer scale, Physical Review Letters, vol.90, issue.7, p.75504, 2003. ,
Compression-induced axial crack propagation in DCDC polymer samples: experiments and modeling. International journal of fracture, vol.141, pp.447-457, 2006. ,
A fracture mechanics analysis of the double cleavage drilled compression test specimen. Engineering Fracture Mechanics, vol.76, pp.921-934, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-01148122
Crack opening profile in DCDC specimen, International journal of fracture, vol.156, issue.1, pp.11-20, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-00371380
In situ experiments with X ray tomography: an attractive tool for experimental mechanics, Experimental mechanics, vol.50, issue.3, pp.289-305, 2010. ,
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography, Ultramicroscopy, vol.157, pp.35-47, 2015. ,
Thermodynamical approach to the brittle fracture of dry plasters, Journal of Materials Science, vol.31, issue.17, pp.4573-4580, 1996. ,
Etude du comportement mécanique du plâtre pris en relation avec sa microstructure, 2010. ,
Analysis of the double cleavage drilled compression specimen for interface fracture energy measurements over a range of mode mixities, Acta Metallurgica et Materialia, vol.43, issue.9, pp.3453-3458, 1995. ,
On the application of X-ray microtomography in the field of materials science, Advanced Engineering Materials, vol.3, issue.8, pp.539-546, 2001. ,
URL : https://hal.archives-ouvertes.fr/hal-00475297
X-ray micro-tomography an attractive characterisation technique in materials science, Nuclear instruments and methods in physics research section B: Beam interactions with materials and atoms, vol.200, pp.273-286, 2003. ,
URL : https://hal.archives-ouvertes.fr/hal-00475146
, Advances in X-ray Tomography for Geomaterials, 2006.
3D imaging in material science: Application of X-ray tomography, Comptes Rendus Physique, vol.11, issue.9, pp.641-649, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00569350
20 Hz X-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1, pp.3-12, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01538199
Void ratio evolution inside shear bands in triaxial sand specimens studied by computed tomography, Géotechnique, vol.46, issue.3, pp.529-546, 1996. ,
Direct observation of crack opening as a function of applied load in the interior of a notched tensile sample of AlLi 2090, Acta Materialia, vol.45, issue.5, pp.1977-1987, 1997. ,
, Situ Synchrotron X-Ray Microtomography Studies of Microstructure and Damage Evolution in Engineering Materials, vol.9, pp.939-950, 2007.
Quantitative X-ray tomography, International Materials Reviews, vol.59, issue.1, pp.1-43, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01538208
Yield behavior beneath hardness indentations in ductile metals, measured by three-dimensional computed X-ray tomography and digital volume correlation, Acta Materialia, vol.82, pp.468-482, 2015. ,
In-situ mechanical properties identification of 3D particulate composites using the Virtual Fields Method, International Journal of Solids And Structures, vol.51, issue.18, pp.3076-3086, 2014. ,
Failure Mechanisms of Plasterboard in Nail Pull Test Determined by X-ray Microtomography and Digital Volume Correlation, Experimental Mechanics, vol.56, pp.1427-1437, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01383905
Toward 4D Mechanical Correlation, Advanced Modeling and Simulation in Engineering Sciences, vol.3, issue.1, p.26, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01310582
A Multigrid PGD-based Algorithm for Volumetric Displacement Fields Measurements, Strain, vol.50, issue.4, pp.355-367, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01015904
Self-calibration for lab-µCT using space-time regularized projection-based DVC and model reduction, Measurement Science and Technology, vol.29, p.24003, 2018. ,
Fast tracking of imbibition using time-resolved neutron tomography, 2017. ,
Digital volume correlation: Review of progress and challenges, Experimental Mechanics, vol.58, issue.5, pp.661-708, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01980039
Signal-to-noise ratio, vol.1, p.2088, 2006. ,
Three-dimensional image correlation from X-ray computed tomography of solid foam, Composites Part A: Applied science and manufacturing, vol.39, issue.8, pp.1253-1265, 2008. ,
URL : https://hal.archives-ouvertes.fr/hal-01006730
Voxel-scale digital volume correlation, Experimental Mechanics, vol.51, issue.4, pp.479-490, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521193
Extraction of stress intensity factors for 3d small fatigue cracks using digital volume correlation and x-ray tomography, International Journal of Fatigue, vol.71, pp.3-10, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01537225
Localized strain field measurement on laminography data with mechanical regularization, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.324, pp.70-79, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-00956440
Digital Volume Correlation Applied to X-ray Tomography Images from Spherical Indentation Tests on Lightweight Gypsum, Strain, vol.50, issue.5, pp.444-453, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01068402
A priori model reduction through proper generalized decomposition for solving time-dependent partial differential equations, Computer Methods in Applied Mechanics and Engineering, vol.199, issue.23, pp.1603-1626, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00455635
Introduction to algorithms, 2009. ,
A space-time approach in digital image correlation: Movie-DIC, Optics and Lasers in Engineering, vol.49, issue.1, pp.71-81, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521203
Analysis of Image Series through Digital Image Correlation, J. Strain Analysis, vol.47, issue.4, pp.214-228, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00694332
Extension of classical experimental techniques for characterizing composite-material behavior, Experimental Mechanics, vol.12, issue.1, pp.50-56, 1972. ,
Statistical identification of structures, AIAA Journal, vol.12, issue.2, pp.185-190, 1974. ,
Self-calibration for lab-µct using space-time regularized projection-based dvc and model reduction, 2017. ,
Elemente der technologischen Mechanik, 1909. ,
The relationship between stress and strain for homogeneous deformation, Journal of the Institute of Metals, vol.74, pp.537-562, 1948. ,
Mechanics of Solid Materials, 1990. ,
Conditions for localization of deformation in pressuresensitive dilatant materials, Journal of the Mechanics and Physics of Solids, vol.23, pp.371-394, 1975. ,
The Localization of Plastic Deformations, pp.207-220, 1976. ,
Prediction of macro-crack initiation by damage localization. Comptes Rendus de l'Académie des Sciences Paris, série, vol.II, pp.347-352, 1989. ,
On linear versus nonlinear flaw rules in strain localization analysis, Meccanica, vol.24, pp.36-41, 1989. ,
Imaging and image-based fluid transport modeling at the pore scale in geological materials: A practical introduction to the current state-of-the-art, Earth-Science Reviews, vol.155, pp.93-128, 2016. ,
Quantitative X-ray tomography, International materials reviews, vol.59, issue.1, pp.1-43, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01538208
20 Hz X-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1-2, pp.3-12, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01538199
4-d imaging of sub-second dynamics in pore-scale processes using real-time synchrotron x-ray tomography, Solid Earth, vol.7, issue.4, p.1059, 2016. ,
Spontaneous imbibition characteristics of diatomite, Journal of Petroleum Science and Engineering, vol.25, issue.3, pp.149-165, 2000. ,
Experimental and analytical study of multidimensional imbibition in fractured porous media, Journal of Petroleum Science and Engineering, vol.36, issue.1, pp.45-60, 2002. ,
4D imaging of fluid flow dynamics in natural porous media with ultrafast X-ray microtomography, International Symposium of the SCA, vol.176, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-01538218
Influence of mechanical damage on fluid flow patterns investigated using CT scanning imaging and acoustic emissions techniques, Geophysical Research Letters, vol.35, issue.16, 2008. ,
Local characterisation of fluid flow in sandstone with localised deformation features through fast neutron imaging, EPJ Web of Conferences, vol.6, p.22008, 2010. ,
High-speed neutron radiography for monitoring the water absorption by capillarity in porous materials, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.266, pp.155-163, 2008. ,
Capturing 3d water flow in rooted soil by ultra-fast neutron tomography, Scientific Reports, vol.7, 2017. ,
Parametric study of factors affecting capillary imbibition in fractured porous media, 2011. ,
Computation of Relative Permeability from In Situ Imaged Fluid Distributions at the Pore Scale, International Petroleum Technology Conference. International Petroleum Technology Conference, 2016. ,
Characterization of fluid flow in a shear band in porous rock using neutron radiography, Geophysical Research Letters, vol.40, issue.11, pp.2613-2618, 2013. ,
Building trust in history matching: The role of multidimensional projection, SPE Europec/EAGE Annual Conference, 2012. ,
Determination of relative permeability and capillary pressure curves using an automated history-matching approach, SPE Eastern Regional/AAPG Eastern Section Joint Meeting, 2008. ,
Measurement of fluid contents and wetting front profiles by real-time neutron radiography, Journal of Hydrology, vol.290, issue.3, pp.192-201, 2004. ,
Anomalous front broadening during spontaneous imbibition in a matrix with elongated pores, Proceedings of the National Academy of Sciences, vol.109, issue.26, pp.10245-10250, 2012. ,
Capillary rise dynamics of liquid hydrocarbons in mesoporous silica as explored by gravimetry, optical and neutron imaging: Nano-rheology and determination of pore size distributions from the shape of imbibition fronts, Colloids and Surfaces A: Physicochemical and Engineering Aspects, vol.496, pp.13-27, 2016. ,
Subsecond pore-scale displacement processes and relaxation dynamics in multiphase flow, Water resources research, vol.50, issue.12, pp.9162-9176, 2014. ,
Toward 4D mechanical correlation, Advanced Modeling and Simulation in Engineering Sciences, vol.3, issue.1, p.17, 2016. ,
DOI : 10.1186/s40323-016-0070-z
URL : https://hal.archives-ouvertes.fr/hal-01310582
Projection savings in CT-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
Measurement of 3D displacement fields from few tomographic projections, SPIE Photonics Europe, pages 98960L98960L. International Society for Optics and Photonics, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01800794
Discrete digital projections correlation: a reconstruction-free Method to quantify local kinematics in granular media by X-ray tomography, Experimental Mechanics, pp.1-12, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01474701
In situ µCT-scan mechanical tests: Fast 4D mechanical identification, Experimental Mechanics, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01576727
A priori model reduction through proper generalized decomposition for solving time-dependent partial differential equations, Computer Methods in Applied Mechanics and Engineering, vol.199, issue.23, pp.1603-1626, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00455635
Nonlinear computational structural mechanics: new approaches and non-incremental methods of calculation, 2012. ,
High resolution digital image correlation using proper generalized decomposition: PGD-DIC, International Journal for Numerical Methods in Engineering, vol.92, issue.6, pp.531-550, 2012. ,
DOI : 10.1002/nme.4349
URL : https://hal.archives-ouvertes.fr/hal-00708541
A Multigrid PGD-based algorithm for Volumetric Displacement Fields Measurements, Strain, vol.50, issue.4, pp.355-367, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01015904
Artefacts in neutron ct-their effects and how to reduce some of them, Physics Procedia, vol.69, pp.244-251, 2015. ,
Correction for beam hardening in computed tomography, Physics in medicine and biology, vol.24, issue.1, p.81, 1979. ,
Experimental characterisation of the localisation phenomenon inside a Vosges sandstone in a triaxial cell, International Journal of Rock Mechanics and Mining Sciences, vol.37, issue.8, pp.1223-1237, 2000. ,
Full-field measurements of strain localisation in sandstone by neutron tomography and 3D-volumetric digital image correlation, Physics Procedia, vol.69, pp.509-515, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01965839
Neutron tomography instrument CONRAD at HZB. Nuclear Instruments and Methods in, Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.651, issue.1, pp.47-52, 2011. ,
DOI : 10.1016/j.nima.2011.01.067
High-speed neutron tomography of fluid flow through rocks, 2018. ,
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography, Ultramicroscopy, vol.157, pp.35-47, 2015. ,
Digital volume correlation: three-dimensional strain mapping using x-ray tomography, Experimental mechanics, vol.39, issue.3, pp.217-226, 1999. ,
Projection savings in ct-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
Développement de la tomographie spatio-temporelle pour le suivi d'essais mécaniques, 2016. ,
Soft route to 4d tomography, Physical review letters, vol.117, issue.2, p.25501, 2016. ,
Measurement of 3d displacement fields from few tomographic projections, Optics, Photonics and Digital Technologies for Imaging Applications IV, vol.9896, p.98960, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01800794
Full field modal measurement with a single standard camera, Optics and Lasers in Engineering, vol.107, pp.265-272, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01762384
In situµ ct-scan mechanical tests: Fast 4d mechanical identification, Experimental Mechanics, vol.57, issue.8, pp.1327-1340, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01576727
The astra toolbox: A platform for advanced algorithm development in electron tomography, Ultramicroscopy, vol.157, pp.35-47, 2015. ,
Three-dimensional image correlation from x-ray computed tomography of solid foam, Composites Part A: Applied science and manufacturing, vol.39, issue.8, pp.1253-1265, 2008. ,
URL : https://hal.archives-ouvertes.fr/hal-00198126
Analysis of long torsional strings by proper orthogonal decomposition, Archive of Applied Mechanics, vol.67, issue.1-2, pp.68-80, 1996. ,
On the physical interpretation of proper orthogonal modes in vibrations, Journal of sound and vibration, vol.211, issue.4, pp.607-616, 1998. ,
Interpreting proper orthogonal modes of randomly excited vibration systems, Journal of Sound and Vibration, vol.265, issue.5, pp.953-966, 2003. ,
Solutions of ill-posed problems, 1978. ,
Voxel-scale digital volume correlation, Experimental Mechanics, vol.51, issue.4, pp.479-490, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521193
Agence Nationale de la Recherche, through the "Investissements d'avenir" Program MATMECA (ANR-10EQPX-37 grant), and the COMINSIDE project ,
, X-Ray Tomography in Material Sciences. Hermès Science, 2000.
, Advances in X-ray Tomography for Geomaterials, 2006.
Principles of computerized tomographic imaging, 1988. ,
3D imaging in material science: Application of X-ray tomography, Comptes Rendus Physique, vol.11, issue.9, pp.641-649, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00569350
20 Hz X-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1, pp.3-12, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01538199
Practical cone-beam algorithm, JOSA A, vol.1, issue.6, pp.612-619, 1984. ,
Toward 4D Mechanical Correlation, Advanced Modeling and Simulation in Engineering Sciences, vol.3, issue.1, p.17, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01310582
Towards geometrical calibration of x-ray computed tomography systems-a review, Measurement Science and Technology, vol.26, issue.9, p.92003, 2015. ,
Accurate technique for complete geometric calibration of cone-beam computed tomography systems, Medical physics, vol.32, issue.4, pp.968-983, 2005. ,
A geometric calibration method for cone beam CT systems, Medical physics, vol.33, issue.6, pp.1695-1706, 2006. ,
A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array, Physics in medicine and biology, vol.59, issue.5, p.1189, 2014. ,
CT for industrial metrology-accuracy and structural resolution of CT dimensional measurements, Conference on Industrial Computed Tomography (ICT), 2012. ,
A calibration method for misaligned scanner geometry in cone-beam computed tomography, NDT & E International, vol.39, issue.6, pp.499-513, 2006. ,
Geometric parameters estimation and calibration in cone-beam micro-CT, Sensors, vol.15, issue.9, pp.22811-22825, 2015. ,
A geometric calibration method for cone beam CT system, Eighth International Conference on Digital Image Processing (ICDIP 2016), pages 100333G-100333G. International Society for Optics and Photonics, 2016. ,
Analysis and artifact correction for volume correlation measurements using tomographic images from a laboratory X-ray source, Exp. Mech, vol.51, issue.6, pp.959-970, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521190
Mechanics of Solid Materials, 1990. ,
´ Etude experimentale de l'´ evolution de la microstructure d'un milieu granulaire sous chargement mécaniquè a l'aide de tomographiè a rayons-x, 2013. ,
An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms, Physics in Medicine and Biology, vol.53, issue.14, p.3841, 2008. ,
Simultaneous misalignment correction for approximate circular cone-beam computed tomography, Physics in Medicine and Biology, vol.53, issue.22, p.6267, 2008. ,
Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery, Physics in medicine and biology, vol.57, issue.17, p.5485, 2012. ,
Robust 3D-2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation, Physics in medicine and biology, vol.58, issue.23, p.8535, 2013. ,
Selfcalibration of cone-beam CT geometry using 3D-2D image registration, Physics in medicine and biology, vol.61, issue.7, p.2613, 2016. ,
A rigid motion correction method for helical computed tomography (CT), Physics in medicine and biology, vol.60, issue.5, p.2047, 2015. ,
An iterative projection-based motion estimation and compensation scheme for head x-ray CT, Medical Physics, vol.43, issue.10, pp.5705-5716, 2016. ,
Computer Vision-Based, Noncontacting Deformation Measurements in Mechanics: A Generational Transformation. Appl. Mech. Rev, vol.65, p.50802, 2013. ,
Digital volume correlation: three-dimensional strain mapping using X-ray tomography, Experimental mechanics, vol.39, issue.3, pp.217-226, 1999. ,
Digital volume correlation including rotational degrees of freedom during minimization, Experimental Mechanics, vol.42, issue.3, pp.272-278, 2002. ,
Projection savings in CT-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
Measurement of 3D displacement fields from few tomographic projections, SPIE Photonics Europe, page 98960. International Society for Optics and Photonics, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01800794
A soft route toward 4D tomography, Physical Review Letters, vol.117, issue.2, p.25501, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01383970
In situ µCT-scan mechanical tests: Fast 4D mechanical identification, Experimental Mechanics, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01576727
Three-dimensional image correlation from X-ray computed tomography of solid foam, Composites Part A: Applied science and manufacturing, vol.39, issue.8, pp.1253-1265, 2008. ,
URL : https://hal.archives-ouvertes.fr/hal-01006730
An extended and integrated digital image correlation technique applied to the analysis of fractured samples: The equilibrium gap method as a mechanical filter, European Journal of Computational Mechanics/Revue Européenne de Mécanique Numérique, vol.18, issue.3-4, pp.285-306, 2009. ,
Mechanics-Aided Digital Image Correlation, J. Strain Analysis, vol.48, pp.330-343, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-00848729
Voxel-scale digital volume correlation, Experimental Mechanics, vol.51, issue.4, pp.479-490, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521193
Localized strain field measurement on laminography data with mechanical regularization, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.324, pp.70-79, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-00956440
Digital Volume Correlation Applied to X-ray Tomography Images from Spherical Indentation Tests on Lightweight Gypsum, Strain, vol.50, issue.5, pp.444-453, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01068402
A space-time approach in digital image correlation: Movie-DIC, Optics and Lasers in Engineering, vol.49, issue.1, pp.71-81, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521203
Analysis of Image Series through Digital Image Correlation, J. Strain Analysis, vol.47, issue.4, pp.214-228, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00694332
A priori model reduction through proper generalized decomposition for solving time-dependent partial differential equations, Computer Methods in Applied Mechanics and Engineering, vol.199, issue.23, pp.1603-1626, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00455635
Nonlinear computational structural mechanics: new approaches and non-incremental methods of calculation, 2012. ,
Model-order reduction for the parametric analysis of damage in reinforced concrete structures, 2016. ,
URL : https://hal.archives-ouvertes.fr/tel-01468261
High resolution digital image correlation using proper generalized decomposition: PGD-DIC, International Journal for Numerical Methods in Engineering, vol.92, issue.6, pp.531-550, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00708541
A Multigrid PGD-based Algorithm for Volumetric Displacement Fields Measurements, Strain, vol.50, issue.4, pp.355-367, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01015904
Introduction to algorithms, 2009. ,
In situ experiments with X ray tomography: an attractive tool for experimental mechanics, Experimental mechanics, vol.50, issue.3, pp.289-305, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-01538062
Correction for beam hardening in computed tomography, Physics in medicine and biology, vol.24, issue.1, p.81, 1979. ,
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography, Ultramicroscopy, vol.157, pp.35-47, 2015. ,
An outlook on x-ray ct research and development, Medical physics, vol.35, issue.3, pp.1051-1064, 2008. ,
X-Ray Tomography in Material Sciences, Hermès Science, 2000. ,
Electron tomography: A threedimensional analytic tool for hard and soft materials research, Advanced Materials, vol.27, issue.38, pp.5638-5663, 2015. ,
Principles of computerized tomographic imaging, 1988. ,
3d imaging in material science: Application of x-ray tomography, Comptes Rendus Physique, vol.11, issue.9, pp.641-649, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00572506
20 hz x-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1, pp.3-12, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01538199
4-d imaging of sub-second dynamics in pore-scale processes using real-time synchrotron x-ray tomography, Solid Earth, vol.7, issue.4, p.1059, 2016. ,
A model of the effect of image motion in the radon transform domain, IEEE Transactions on Image Processing, vol.8, issue.9, pp.1276-1281, 1999. ,
In vivo time-resolved microtomography reveals the mechanics of the blowfly flight motor, PLoS biology, vol.12, issue.3, p.1001823, 2014. ,
Motion-Corrected Reconstruction in Cone-Beam Computed Tomography for Knees under Weight-Bearing Condition, 2016. ,
Dynamic x-ray computed tomography, Proceedings of the IEEE, vol.91, issue.10, pp.1574-1587, 2003. ,
Towards geometrical calibration of x-ray computed tomography systems-a review, Measurement Science and Technology, vol.26, issue.9, p.92003, 2015. ,
A rigid motion correction method for helical computed tomography (ct), Physics in Medicine and Biology, vol.60, issue.5, p.2047, 2015. ,
An iterative projection-based motion estimation and compensation scheme for head x-ray ct, Medical physics, vol.43, issue.10, pp.5705-5716, 2016. ,
Tomographic motion detection and correction directly in sinogram space, Physics in Medicine and Biology, vol.47, issue.8, p.1267, 2002. ,
Exact reconstruction in 2d dynamic ct: compensation of time-dependent affine deformations, Physics in Medicine and Biology, vol.49, issue.11, p.2169, 2004. ,
URL : https://hal.archives-ouvertes.fr/hal-00308419
Self-calibration for lab-µct using space-time regularized projection-based dvc and model reduction, Measurement Science and Technology, vol.29, issue.2, p.24003, 2018. ,
DOI : 10.1088/1361-6501/aa9818
URL : https://hal.archives-ouvertes.fr/hal-01633741/file/MST_Calibration_accepted.pdf
Automatic localization of vertebral levels in x-ray fluoroscopy using 3d-2d registration: a tool to reduce wrong-site surgery, Physics in Medicine and Biology, vol.57, issue.17, p.5485, 2012. ,
Selfcalibration of cone-beam ct geometry using 3d-2d image registration, Physics in Medicine and Biology, vol.61, issue.7, p.2613, 2016. ,
Projection savings in ct-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
A soft route toward 4d tomography, Physical Review Letters, vol.117, issue.2, p.25501, 2016. ,
DOI : 10.1103/physrevlett.117.025501
URL : https://hal.archives-ouvertes.fr/hal-01383970
In situµ ct-scan mechanical tests: Fast 4d mechanical identification, Experimental Mechanics, vol.57, issue.8, pp.1327-1340, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01576727
Respiratory motion estimation from slowly rotating x-ray projections: Theory and simulation, Medical physics, vol.32, issue.4, pp.984-991, 2005. ,
DOI : 10.1118/1.1879132
URL : http://web.eecs.umich.edu/~fessler/papers/lists/files/proc/04/pre/zeng-04-rme.pdf
Estimating 3-d respiratory motion from orbiting views by tomographic image registration, IEEE Transactions on Medical Imaging, vol.26, issue.2, pp.153-163, 2007. ,
DOI : 10.1109/tmi.2006.889719
URL : https://deepblue.lib.umich.edu/bitstream/2027.42/85995/1/Fessler38.pdf
Enhanced 4d cone-beam ct with inter-phase motion model, Medical physics, vol.34, issue.9, pp.3688-3695, 2007. ,
DOI : 10.1118/1.2767144
In-room breathing motion estimation from limited projection views using a sliding deformation model, Journal of Physics: Conference Series, vol.489, p.12026, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-00847368
Projection-based motion estimation for cardiac functional analysis with high temporal resolution: a proof-of-concept study with digital phantom experiment, International Society for Optics and Photonics, vol.10132, p.1013230, 2017. ,
Motion correction for improved target localization with on-board cone-beam computed tomography, Physics in Medicine and Biology, vol.51, issue.2, p.253, 2006. ,
Cardiac c-arm ct: Efficient motion correction for 4d-fbp, Nuclear Science Symposium Conference Record, vol.4, pp.2620-2628, 2006. ,
DOI : 10.1109/nssmic.2006.354444
Cardiac c-arm ct: a unified framework for motion estimation and dynamic ct, IEEE Transactions on Medical Imaging, vol.28, issue.11, pp.1836-1849, 2009. ,
DOI : 10.1109/tmi.2009.2025499
URL : http://www5.informatik.uni-erlangen.de/Forschung/Publikationen/2009/Pruemmer09-CCC.pdf
Comparison of analytic and algebraic methods for motion-compensated cone-beam ct reconstruction of the thorax, IEEE Transactions on Medical Imaging, vol.28, issue.10, pp.1513-1525, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-00443440
Four dimensional material movies: High speed phase-contrast tomography by backprojection along dynamically curved paths, Scientific reports, vol.7, issue.1, p.6487, 2017. ,
DOI : 10.1038/s41598-017-06333-6
URL : https://www.nature.com/articles/s41598-017-06333-6.pdf
Practical cone-beam algorithm, Journal of the Optical Society of America A, vol.1, issue.6, pp.612-619, 1984. ,
DOI : 10.1364/josaa.1.000612
Dart: a practical reconstruction algorithm for discrete tomography, IEEE Transactions on Image Processing, vol.20, issue.9, pp.2542-2553, 2011. ,
DOI : 10.1109/tip.2011.2131661
Efficient binary tomographic reconstruction, Journal of Mathematical Imaging and Vision, vol.49, issue.2, pp.335-351, 2014. ,
DOI : 10.1007/s10851-013-0465-0
URL : https://hal.archives-ouvertes.fr/hal-01003479
Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information, IEEE Transactions on information theory, vol.52, issue.2, pp.489-509, 2006. ,
Low-dose x-ray ct reconstruction via dictionary learning, IEEE Transactions on Medical Imaging, vol.31, issue.9, pp.1682-1697, 2012. ,
Digital volume correlation: Review of progress and challenges, Experimental Mechanics, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01744752
Quantitative x-ray tomography, International materials reviews, vol.59, issue.1, pp.1-43, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01538208
Sequential identification of boundary support parameters in a fluidstructure vascular model using patient image data, Biomechanics and modeling in mechanobiology, vol.12, issue.3, pp.475-496, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-00760703
Full-field measurements and identification in solid mechanics, 2012. ,
Real-time cardiovascular magnetic resonance at 1.5 t using balanced ssfp and 40 ms resolution, Journal of Cardiovascular Magnetic Resonance, vol.15, issue.1, p.79, 2013. ,
An outlook on x-ray ct research and development, Medical physics, vol.35, issue.3, pp.1051-1064, 2008. ,
Laboratory cryo x-ray microscopy for 3d cell imaging, Scientific reports, vol.7, issue.1, p.13433, 2017. ,
X-Ray Tomography in Material Sciences, Hermès Science, 2000. ,
Quantitative x-ray tomography, International materials reviews, vol.59, issue.1, pp.1-43, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01538208
3d imaging in material science: Application of x-ray tomography, Comptes Rendus Physique, vol.11, issue.9, pp.641-649, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00569350
Principles of computerized tomographic imaging, 1988. ,
A model of the effect of image motion in the radon transform domain, IEEE Transactions on Image Processing, vol.8, issue.9, pp.1276-1281, 1999. ,
Spatiotemporal motion estimation for respiratory-correlated imaging of the lungs, Medical physics, vol.38, issue.1, pp.166-178, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00630618
Fast x-ray tomography analysis of bubble growth and foam setting during breadmaking, Journal of Cereal Science, vol.43, issue.3, pp.393-397, 2006. ,
URL : https://hal.archives-ouvertes.fr/hal-00141792
In situ and real-time 3-d microtomography investigation of dendritic solidification in an al-10 wt.% cu alloy, Acta Materialia, vol.57, issue.7, pp.2300-2310, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-00378057
The popi-model, a pointvalidated pixel-based breathing thorax model, XVth international conference on the use of computers in radiation therapy (ICCR), vol.2, pp.195-199, 2007. ,
Four-dimensional in vivo x-ray microscopy with projection-guided gating, Scientific reports, vol.5, p.8727, 2015. ,
Fast microtomography using high energy synchrotron radiation, Review of Scientific Instruments, vol.76, issue.4, p.43702, 2005. ,
A scheme for multisource interior tomography, Medical physics, vol.36, issue.8, pp.3575-3581, 2009. ,
First performance evaluation of a dual-source ct (dsct) system, European radiology, vol.16, issue.2, pp.256-268, 2006. ,
20 hz x-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1, pp.3-12, 2016. ,
DOI : 10.1007/s10704-016-0077-y
URL : https://hal.archives-ouvertes.fr/hal-01538199
4-d imaging of sub-second dynamics in pore-scale processes using real-time synchrotron x-ray tomography, Solid Earth, vol.7, issue.4, p.1059, 2016. ,
Effects of dose reduction on diagnostic image quality of coronary computed tomography angiography in children using a third-generation dual-source computed tomography scanner, The American Journal of Cardiology, 2018. ,
Full-field measurements and identification in solid mechanics, 2012. ,
Digital volume correlation: Review of progress and challenges, Experimental Mechanics, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01744752
Sequential identification of boundary support parameters in a fluidstructure vascular model using patient image data, Biomechanics and modeling in mechanobiology, vol.12, issue.3, pp.475-496, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-00760703
A hybrid patient-specific biomechanical model based image registration method for the motion estimation of lungs, Medical image analysis, vol.39, pp.87-100, 2017. ,
Deformation and dynamic response of abdominal aortic aneurysm sealing, Scientific reports, vol.7, issue.1, p.17712, 2017. ,
DOI : 10.1038/s41598-017-17759-3
URL : https://www.nature.com/articles/s41598-017-17759-3.pdf
Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic ct, Medical physics, vol.39, issue.2, pp.1006-1015, 2012. ,
Three-dimensional analysis of a tensile test on a propellant with digital volume correlation, Archives of Mechanics, vol.63, issue.5-6, pp.1-20, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00634714
A dynamic elastic model for segmentation and tracking of the heart in mr image sequences, Medical Image Analysis, vol.14, issue.6, pp.738-749, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00877519
Registration of 4d cardiac ct sequences under trajectory constraints with multichannel diffeomorphic demons, IEEE transactions on medical imaging, vol.29, issue.7, pp.1351-1368, 2010. ,
URL : https://hal.archives-ouvertes.fr/inria-00616101
Digital volume correlation: three-dimensional strain mapping using x-ray tomography, Experimental mechanics, vol.39, issue.3, pp.217-226, 1999. ,
DOI : 10.1007/bf02323555
An optimization-based method for geometrical calibration in cone-beam ct without dedicated phantoms, Physics in Medicine & Biology, vol.53, issue.14, p.3841, 2008. ,
Automatic localization of vertebral levels in x-ray fluoroscopy using 3d-2d registration: a tool to reduce wrong-site surgery, Physics in Medicine and Biology, vol.57, issue.17, p.5485, 2012. ,
Selfcalibration of cone-beam ct geometry using 3d-2d image registration, Physics in Medicine and Biology, vol.61, issue.7, p.2613, 2016. ,
Self-calibration for lab-µct using space-time regularized projection-based dvc and model reduction, Measurement Science and Technology, vol.29, issue.2, p.24003, 2018. ,
DOI : 10.1088/1361-6501/aa9818
URL : https://hal.archives-ouvertes.fr/hal-01633741/file/MST_Calibration_accepted.pdf
Automatic alignment for threedimensional tomographic reconstruction, Inverse Problems, vol.34, issue.2, p.24004, 2018. ,
Exact reconstruction in 2d dynamic ct: compensation of time-dependent affine deformations, Physics in Medicine and Biology, vol.49, issue.11, p.2169, 2004. ,
URL : https://hal.archives-ouvertes.fr/hal-00308419
Cardiac c-arm ct: Efficient motion correction for 4d-fbp, Nuclear Science Symposium Conference Record, vol.4, pp.2620-2628, 2006. ,
Cardiac c-arm ct: a unified framework for motion estimation and dynamic ct, IEEE Transactions on Medical Imaging, vol.28, issue.11, pp.1836-1849, 2009. ,
Comparison of analytic and algebraic methods for motion-compensated cone-beam ct reconstruction of the thorax, IEEE Transactions on Medical Imaging, vol.28, issue.10, pp.1513-1525, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-00443440
Four dimensional material movies: High speed phase-contrast tomography by backprojection along dynamically curved paths, Scientific reports, vol.7, issue.1, p.6487, 2017. ,
Motion compensated micro-ct reconstruction for in-situ analysis of dynamic processes, Scientific reports, vol.8, issue.1, p.7655, 2018. ,
Space-time tomography for continuously deforming objects, ACM Transactions on Graphics, 2018. ,
Dynamic x-ray radiography reveals particle size and shape orientation fields during granular flow, Scientific Reports, vol.7, issue.1, p.8155, 2017. ,
Respiratory motion estimation from slowly rotating x-ray projections: Theory and simulation, Medical physics, vol.32, issue.4, pp.984-991, 2005. ,
Estimating 3-d respiratory motion from orbiting views by tomographic image registration, IEEE Transactions on Medical Imaging, vol.26, issue.2, pp.153-163, 2007. ,
A review of 3d/2d registration methods for image-guided interventions, Medical image analysis, vol.16, issue.3, pp.642-661, 2012. ,
In-room breathing motion estimation from limited projection views using a sliding deformation model, Journal of Physics: Conference Series, vol.489, p.12026, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-00847368
Projection-based motion estimation for cardiac functional analysis with high temporal resolution: a proof-of-concept study with digital phantom experiment, International Society for Optics and Photonics, vol.10132, p.1013230, 2017. ,
Projection savings in ct-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
A soft route toward 4d tomography, Physical Review Letters, vol.117, issue.2, p.25501, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01383970
In situµ ct-scan mechanical tests: Fast 4d mechanical identification, Experimental Mechanics, vol.57, issue.8, pp.1327-1340, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01576727
Dynamic tomography of moving samples. submitted, 2018. ,
CT artifacts: causes and reduction techniques, Imaging in Medicine, vol.4, issue.2, pp.229-240, 2012. ,
Investigation of artefact sources in synchrotron microtomography via virtual X-ray imaging, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.234, pp.333-348, 2005. ,
URL : https://hal.archives-ouvertes.fr/hal-01921005
The astra toolbox: A platform for advanced algorithm development in electron tomography, Ultramicroscopy, vol.157, pp.35-47, 2015. ,
Digital volume correlation including rotational degrees of freedom during minimization, Experimental Mechanics, vol.42, issue.3, pp.272-278, 2002. ,
Voxel-scale digital volume correlation, Experimental Mechanics, vol.51, issue.4, pp.479-490, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521193
finite-element" displacement fields analysis from digital images: application to portevin-le châtelier bands, Experimental Mechanics, vol.46, issue.6, pp.789-803, 2006. ,
Estimation of elastoplastic parameters via weighted femu and integrated-dic, Experimental Mechanics, vol.55, issue.1, pp.105-119, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166755
Spatiotemporal regularization for digital image correlation: Application to infrared camera frames, International Journal for Numerical Methods in Engineering, vol.114, issue.12, pp.1331-1349, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01710075
A space-time pgd-dic algorithm, Experimental Mechanics, pp.1-12, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01772657
Dart: a practical reconstruction algorithm for discrete tomography, IEEE Transactions on Image Processing, vol.20, issue.9, pp.2542-2553, 2011. ,
Efficient binary tomographic reconstruction, Journal of Mathematical Imaging and Vision, vol.49, issue.2, pp.335-351, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01003479
20 hz x-ray tomography during an in situ tensile test, International Journal of Fracture, vol.200, issue.1, pp.3-12, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01538199
In situµ ct-scan mechanical tests: Fast 4d mechanical identification, Experimental Mechanics, vol.57, issue.8, pp.1327-1340, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01576727
Fast 4d tensile test monitored via x-ct: Single projection based digital volume correlation dedicated to slender samples. submitted, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01847191
Fast 4d tensile test monitored via x-ct: Elastoplastic identification from radiographs. submitted, 2018. ,
Self-calibration for lab-µct using space-time regularized projection-based dvc and model reduction, Measurement Science and Technology, vol.29, issue.2, p.24003, 2018. ,
Fast tracking of fluid invasion using time-resolved neutron tomography, Transport in Porous Media, pp.1-19, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01800787
Projection savings in ct-based digital volume correlation, Experimental Mechanics, vol.55, issue.1, pp.275-287, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166750
Développement de la tomographie spatio-temporelle pour le suivi d'essais mécaniques, 2016. ,
Soft route to 4d tomography, Physical review letters, vol.117, issue.2, p.25501, 2016. ,
Measurement of 3d displacement fields from few tomographic projections, Optics, Photonics and Digital Technologies for Imaging Applications IV, vol.9896, p.98960, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01800794
Dynamic tomography of moving samples. submitted, 2018. ,
Solutions of ill-posed problems, 1978. ,
Voxel-scale digital volume correlation, Experimental Mechanics, vol.51, issue.4, pp.479-490, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00521193
Digital image correlation and fracture: an advanced technique for estimating stress intensity factors of 2d and 3d cracks, Journal of Physics D: Applied Physics, vol.42, issue.21, p.214004, 2009. ,
URL : https://hal.archives-ouvertes.fr/hal-00381646
Estimation of elastoplastic parameters via weighted femu and integrated-dic, Experimental Mechanics, vol.55, issue.1, pp.105-119, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01166755
Improving full-field identification using progressive model enrichments, International Journal of Solids and Structures, vol.118, pp.213-223, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01549237
Optimization of a cruciform specimen geometry for the identification of constitutive parameters based upon full-field measurements, Strain, vol.52, issue.4, pp.307-323, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01383975
Electron tomography: A threedimensional analytic tool for hard and soft materials research, Advanced Materials, vol.27, issue.38, pp.5638-5663, 2015. ,
In situ experiments with x ray tomography: an attractive tool for experimental mechanics, Experimental mechanics, vol.50, issue.3, pp.289-305, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-01538062
Failure mechanisms of plasterboard in nail pull test determined by x-ray microtomography and digital volume correlation, Experimental Mechanics, vol.56, issue.8, pp.1427-1437, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01383905
Damage law identification from full field displacement measurement: Application to four-point bending test for plasterboard, European Journal of Mechanics-A/Solids, vol.49, pp.60-66, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01068546
Mechanical and fatigue properties of bellows determined with Integrated DIC and IR Thermography, 2016. ,
URL : https://hal.archives-ouvertes.fr/tel-01370444
Validation of registration techniques applied to xrd signals for stress evaluations in titanium alloys, Experimental Mechanics, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01744738
Substructuring of dynamical systems via the adaptive minimal control synthesis algorithm. Earthquake engineering & structural dynamics, vol.30, pp.865-877, 2001. ,
Modern testing techniques for structural systems: dynamics and control, vol.502, 2009. ,
A complex mixed-mode crack propagation test performed with a 6-axis testing machine and full-field measurements, Engineering Fracture Mechanics, vol.176, pp.1-22, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01480988
Virtual hybrid test control of sinuous crack, Journal of the Mechanics and Physics of Solids, vol.102, pp.239-256, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01549224
Multiscale displacement field measurement using digital image correlation: Application to the identification of elastic properties, Experimental Mechanics, vol.55, issue.1, pp.121-137, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-00949038
An extension of digital volume correlation for multimodality image registration, Measurement Science and Technology, vol.28, issue.9, p.95401, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-01633737
Dual-energy ct: general principles, American Journal of Roentgenology, vol.199, issue.5, pp.3-8, 2012. ,
Dual-energy multidetector ct: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging?, Radiographics, vol.30, issue.4, pp.1037-1055, 2010. ,
Dual-energy ct as a potential new diagnostic tool in the management of gout in the acute setting, American Journal of Roentgenology, vol.194, issue.4, pp.1072-1078, 2010. ,
Dual energy ct inspection of a carbon fibre reinforced plastic composite combined with metal components. Case studies in nondestructive testing and evaluation, vol.6, pp.47-55, 2016. ,
Acoustomotive optical coherence elastography for measuring material mechanical properties, Optics letters, vol.34, issue.19, pp.2894-2896, 2009. ,
Observation of sound-induced corneal vibrational modes by optical coherence tomography, Biomedical optics express, vol.6, issue.9, pp.3313-3319, 2015. ,
Estimation of the mechanical properties of the eye through the study of its vibrational modes, PloS one, vol.12, issue.9, p.183892, 2017. ,
Optical coherence elastography-oct at work in tissue biomechanics, Biomedical optics express, vol.8, issue.2, pp.1172-1202, 2017. ,
The emergence of optical elastography in biomedicine, Nature Photonics, vol.11, issue.4, pp.215-221, 2017. ,
3d mapping of elastic modulus using shear wave optical micro-elastography, Scientific reports, vol.6, p.35499, 2016. ,
Tissue elasticity estimation with optical coherence elastography: toward mechanical characterization of in vivo soft tissue, Annals of biomedical engineering, vol.33, issue.11, pp.1631-1639, 2005. ,
3d static elastography at the micrometer scale using full field oct, Biomedical optics express, vol.4, issue.10, pp.2138-2149, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-01709281
Optical coherence elastography: current status and future applications, Journal of biomedical optics, vol.16, issue.4, pp.43001-043001, 2011. ,
The evolution of vibration sonoelastography, Current Medical Imaging Reviews, vol.7, issue.4, pp.283-291, 2011. ,
Supersonic shear imaging: a new technique for soft tissue elasticity mapping, IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol.51, issue.4, pp.396-409, 2004. ,
The molecular trigger for high-speed wing beats in a bee, Science, vol.341, issue.6151, pp.1243-1246, 2013. ,
Deformation and dynamic response of abdominal aortic aneurysm sealing, Scientific reports, vol.7, issue.1, p.17712, 2017. ,