Magnetic Resonance Elastography of Emphysematous Rat Lung in vivo Discretization , accuracy, and precision in Magnetic Resonance Elastography reconstruction In: Proceedings of the 33th Meeting of the European Society of Feasibility of liver shear wave elastography with different transducers Diagnostic accuracy of transrectal elastosonography (TRES) imaging for the diagnosis of prostate cancer: a systematic review and meta-analysis, Proceedings of the 25th Meeting of the International Society MR and Ultrasound Elastography: Phantom comparison study. In: Proceedings of the 14th Meeting of International Tissue Elasticity Conference (ITEC), pp.1414-1423, 2012. ,
Characterizing the elastic properties of tissues, Materials Today, vol.14, issue.3, pp.96-105, 2011. ,
DOI : 10.1016/S1369-7021(11)70059-1
Quantitative seismology, 2002. ,
Incorporating endorectal MR elastography into multi-parametric MRI for prostate cancer imaging: Initial feasibility in volunteers, Journal of Magnetic Resonance Imaging, vol.57, issue.5, pp.1251-1260, 2013. ,
DOI : 10.1088/0031-9155/57/3/R35
Quantitative 3D magnetic resonance elastography: Comparison with dynamic mechanical analysis, Magnetic resonance in medicine, 2016. ,
DOI : 10.1037/0033-2909.86.2.420
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.26207/pdf
Assessment of liver viscoelasticity using multifrequency MR elastography, Magnetic Resonance in Medicine, vol.45, issue.2, pp.373-379, 2008. ,
DOI : 10.1007/978-3-642-73602-5
Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging???Preliminary Results, Radiology, vol.256, issue.1, pp.297-303, 2010. ,
DOI : 10.1148/radiol.10090385
Theoretical limitations of the elastic wave equation inversion for tissue elastography, The Journal of the Acoustical Society of America, vol.126, issue.3, pp.1541-1551, 2009. ,
DOI : 10.1121/1.3180495
The Utility of the "Bull's-Eye" Artifact on Breast Elasticity Imaging in Reducing Breast Lesion Biopsy Rate, Ultrasound Quarterly, vol.27, issue.3, pp.151-155, 2011. ,
DOI : 10.1097/RUQ.0b013e31822a9c75
Evaluation of Breast Lesions Using Sonographic Elasticity Imaging, Journal of Ultrasound in Medicine, vol.27, issue.(suppl), pp.281-287, 2012. ,
DOI : 10.1097/RUQ.0b013e31822a9c75
Noninvasive In Vivo Liver Fibrosis Evaluation Using Supersonic Shear Imaging: A Clinical Study on 113 Hepatitis C Virus Patients, Ultrasound in Medicine & Biology, vol.37, issue.9, pp.1361-1373, 2011. ,
DOI : 10.1016/j.ultrasmedbio.2011.05.016
Measurement of liver stiffness with two imaging techniques: Magnetic resonance elastography and ultrasound elastometry, Journal of Magnetic Resonance Imaging, vol.5, issue.5, pp.1287-1292, 2008. ,
DOI : 10.3748/wjg.v12.i48.7768
URL : https://hal.archives-ouvertes.fr/hal-00336358
In vivo breast tumor detection using transient elastography, Ultrasound in medicine & biology 29.10, pp.1387-1396, 2003. ,
DOI : 10.1016/S0301-5629(03)00978-5
L'imagerie échographique ultrarapide et son application à l'étude de la viscoelasticité du corps humain, 2004. ,
Supersonic shear imaging: a new technique for soft tissue elasticity mapping, IEEE transactions on ultrasonics, ferroelectrics, and frequency control 51.4, pp.396-409, 2004. ,
DOI : 10.1109/TUFFC.2004.1295425
Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses, Radiology, vol.262, issue.2, pp.435-449, 2012. ,
DOI : 10.1148/radiol.11110640
Balanced alternating steady-state elastography, Magnetic resonance in medicine 55.2, pp.233-241, 2006. ,
DOI : 10.1002/mrm.20812
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.20812/pdf
Non-invasive evaluation of liver fibrosis: a comparison of ultrasound-based transient elastography and MR elastography in patients with viral hepatitis B and C, European Radiology, vol.6736, issue.3, p.638, 2014. ,
DOI : 10.1111/j.1478-3231.2009.02100.x
Real-Time Elastography for the Differentiation of Benign and Malignant Thyroid Nodules: A Meta-Analysis, Thyroid, vol.20, issue.10, pp.1145-1150, 2010. ,
DOI : 10.1089/thy.2010.0079
Electromagnetic actuator for generating variably oriented shear waves in MR elastography, Magnetic resonance in medicine 50.1, pp.220-222, 2003. ,
DOI : 10.1002/mrm.10479
The Impact of Real-Time Elastography Guiding a Systematic Prostate Biopsy to Improve Cancer Detection Rate: A Prospective Study of 353 Patients, The Journal of urology 187.6, pp.2039-2043, 2012. ,
DOI : 10.1016/j.juro.2012.01.063
ROOT ??? An object oriented data analysis framework, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.389, issue.1-2, pp.1-2, 1997. ,
DOI : 10.1016/S0168-9002(97)00048-X
URL : http://cds.cern.ch/record/491486/files/p11.pdf
2-D Locally Regularized Tissue Strain Estimation From Radio-Frequency Ultrasound Images: Theoretical Developments and Results on Experimental Data, IEEE Transactions on Medical Imaging, vol.27, issue.2, pp.145-160, 2008. ,
DOI : 10.1109/TMI.2007.897408
URL : https://dspace.cvut.cz/bitstream/10467/9187/1/2008-2d-locally-regularized-tissue-strain.pdf
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments, Physical Review, vol.88, issue.3, p.630, 1954. ,
DOI : 10.1103/PhysRev.88.1070
Interférométrie-Speckle ultrasonore: Application à la mesure d'élasticité, 1998. ,
Feasibility of liver shear wave elastography with different transducers, 2016 IEEE International Ultrasonics Symposium (IUS), pp.1-4, 2016. ,
DOI : 10.1109/ULTSYM.2016.7728400
Needle shear wave driver for magnetic resonance elastography, Magnetic resonance in medicine 55.5, pp.1175-1179, 2006. ,
DOI : 10.1148/radiology.134.2.7352242
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.20856/pdf
Quantifying elasticity and viscosity from measurement of shear wave speed dispersion, The Journal of the Acoustical Society of America, vol.115, issue.6, pp.2781-2785, 2004. ,
DOI : 10.1121/1.1739480
Aliasing artifact depicted on ultrasound (US)-elastography for breast cystic lesions mimicking solid masses, Acta Radiologica, vol.9, issue.1, pp.3-7, 2011. ,
DOI : 10.1016/j.ultrasmedbio.2007.07.003
Performance of Transient Elastography for the Staging of Liver Fibrosis in Patients with Chronic Hepatitis B: A Meta-Analysis, PLoS ONE, vol.7, issue.9, p.44930, 2012. ,
DOI : 10.1371/journal.pone.0044930.s001
Interventional MR elastography for MRI-guided percutaneous procedures, Magnetic Resonance in Medicine, vol.23, issue.3, 2015. ,
DOI : 10.1016/j.mri.2004.11.060
Trans-rectal quantitative shear wave elastography: application to prostate cancer?a feasibility study, Proceedings of the European Congress of Radiology, 2011. ,
EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications, Ultraschall in der Medizin-European Journal of Ultrasound 34.03, pp.238-253, 2013. ,
Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: initial comparison with MRI " . In: Ultrasound in medicine & biology 31, pp.1461-1468, 2005. ,
Real-Time Sonoelastography: Findings in Patients with Symptomatic Achilles Tendons and Comparison to Healthy Volunteers, Ultraschall in der Medizin-European Journal of Ultrasound 31.04, pp.394-400, 2010. ,
DOI : 10.1055/s-0028-1109809
Palpation par force de radiation ultrasonore et échographie ultrarapide: Applications à la caractérisation tissulaire in vivo, 2008. ,
Investigating liver stiffness and viscosity for fibrosis, steatosis and activity staging using shear wave elastography, Journal of hepatology 62, pp.317-324, 2015. ,
DOI : 10.1016/j.jhep.2014.09.020
A freehand elastographic imaging approach for clinical breast imaging: system development and performance evaluation, Ultrasound in medicine & biology 27.10, pp.1347-1357, 2001. ,
DOI : 10.1016/S0301-5629(01)00429-X
Vibro-acoustography: An imaging modality based on ultrasound-stimulated acoustic emission, Proceedings of the National Academy of Sciences 96.12, pp.6603-6608, 1999. ,
DOI : 10.1121/1.381834
URL : http://www.pnas.org/content/96/12/6603.full.pdf
Higher-resolution MR elastography reveals early mechanical signatures of neuroinflammation in patients with clinically isolated syndrome, Journal of Magnetic Resonance Imaging, 2015. ,
Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: A pilot study, Hepatology 56.6, pp.2125-2133, 2012. ,
DOI : 10.1056/NEJM200102153440706
Magnetic-resonance imaging techniques for detection of elasticity variation, Medical physics 22, pp.1771-1778, 1995. ,
DOI : 10.1118/1.597633
Physical boundary conditions reconstruction: a novel method to determine viscoelastic parameters from magnetic resonance elastography data, Proceedings of the International Society for Magnetic Resonance in Medicine, 2011. ,
Rapid acquisition of multifrequency, multislice and multidirectional MR elastography data with a fractionally encoded gradient echo sequence, NMR in Biomedicine, vol.38, issue.2, pp.1326-1335, 2013. ,
DOI : 10.1016/j.ultrasmedbio.2011.10.019
Le palpeur acoustique: un nouvel outils d'investigation des tissus biologiques, 2003. ,
URL : https://hal.archives-ouvertes.fr/tel-00006100
An Analysis of the Total Least Squares Problem, SIAM Journal on Numerical Analysis, vol.17, issue.6, pp.883-893, 1980. ,
DOI : 10.1137/0717073
In vivo realtime freehand palpation imaging, Ultrasound in medicine & biology 29.3, pp.427-435, 2003. ,
DOI : 10.1016/s0301-5629(02)00733-0
RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging, 2013 IEEE International Ultrasonics Symposium (IUS), pp.397-400, 2013. ,
DOI : 10.1109/ULTSYM.2013.0103
Imaging articular cartilage under compression?cartilage elastography, Magnetic resonance in medicine 53.5, pp.1065-1073, 2005. ,
DOI : 10.1148/radiology.205.2.9356644
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.20439/pdf
Freehand ultrasound elastography of breast lesions: clinical results, Ultrasound in medicine & biology 27, pp.1461-1469, 2001. ,
DOI : 10.1016/S0301-5629(01)00434-3
MR Elastography of the Liver and the Spleen Using a Piezoelectric Driver, Single-Shot Wave-Field Acquisition, and Multifrequency Dual Parameter Reconstruction, Magnetic resonance in medicine 71.1, pp.267-277, 2014. ,
DOI : 10.2214/AJR.10.5989
Normal Liver Stiffness in Healthy Adults Assessed By Real-Time Shear Wave Elastography and Factors That Influence This Method, Ultrasound in medicine & biology 40, pp.2549-2555, 2014. ,
DOI : 10.1016/j.ultrasmedbio.2014.05.008
Liver fibrosis: non-invasive assessment with MR elastography, NMR in Biomedicine, vol.67, issue.2, pp.173-179, 2006. ,
DOI : 10.1136/bmj.313.7059.744
Liver Fibrosis: Noninvasive Assessment with MR Elastography versus Aspartate Aminotransferase???to-Platelet Ratio Index, Radiology, vol.245, issue.2, pp.458-466, 2007. ,
DOI : 10.1148/radiol.2452061673
Magnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis, Gastroenterology, vol.135, issue.1, pp.32-40, 2008. ,
DOI : 10.1053/j.gastro.2008.03.076
MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging, European radiology 18, pp.2535-2541, 2008. ,
DOI : 10.1155/2000/107982
Breast Disease: Clinical Application of US Elastography for Diagnosis, Radiology, vol.239, issue.2, pp.341-350, 2006. ,
DOI : 10.1148/radiol.2391041676
Acoustic radiation force impulse imaging (ARFI) for non-invasive detection of liver fibrosis: examination standards and evaluation of interlobe differences in healthy subjects and chronic liver disease, Scandinavian Journal of Gastroenterology, vol.50, issue.12, pp.1458-1467, 2011. ,
DOI : 10.1016/j.jhep.2008.07.039
Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity, Physics in medicine and biology 52, p.7281, 2007. ,
DOI : 10.1088/0031-9155/52/24/006
Achilles tendon assessed with sonoelastography: histologic agreement, In: Radiology, vol.2673, pp.837-842, 2013. ,
A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue, J Rehabil Res Dev, vol.24, issue.2, pp.1-8, 1987. ,
MR-guided transcranial brain HIFU in small animal models, Physics in medicine and biology 55, p.365, 2009. ,
DOI : 10.1088/0031-9155/55/2/003
URL : https://hal.archives-ouvertes.fr/inserm-00542898
In vivo monitoring of elastic changes during cancer development and therapeutic treatment, 2012. ,
URL : https://hal.archives-ouvertes.fr/pastel-00786531
???Sonoelasticity??? images derived from ultrasound signals in mechanically vibrated tissues, Ultrasound in medicine & biology 16.3, pp.231-239, 1990. ,
DOI : 10.1016/0301-5629(90)90002-T
Quantitative Elastography of Liver Fibrosis and Spleen Stiffness in Chronic Hepatitis B Carriers: Comparison of Shear-Wave Elastography and Transient Elastography with Liver Biopsy Correlation, Radiology, vol.269, issue.3, pp.910-918, 2013. ,
DOI : 10.1148/radiol.13130128
EASL Clinical Practice Guidelines: management of hepatitis C virus infection, In: Journal of Hepatology, vol.60, issue.2, p.392, 2014. ,
Thyroid Gland Tumor Diagnosis at US Elastography, Radiology, vol.237, issue.1, pp.202-211, 2005. ,
DOI : 10.1148/radiol.2363041248
Whole brain MRE with guided pressure waves, Proceedings of the 19th Meeting of the International Society, 2011. ,
Image processing for magnetic-resonance elastography, Medical Imaging 1996. International Society for Optics and Photonics, pp.616-623, 1996. ,
DOI : 10.1117/12.237965
Magnetic resonance elastography: noninvasive mapping of tissue elasticity, Medical image analysis 5.4, pp.237-254, 2001. ,
DOI : 10.1016/s1361-8415(00)00039-6
Spatio-temporal directional filtering for improved inversion of MR elastography images, Medical image analysis 7.4, pp.465-473, 2003. ,
Magnetic resonance elastography: A review, Clinical anatomy 23.5, pp.497-511, 2010. ,
DOI : 10.1148/radiology.169.1.3420283
URL : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3066083/pdf
High-frequency mode conversion technique for stiff lesion detection with magnetic resonance elastography (MRE), Magnetic Resonance in Medicine, vol.24, issue.6, pp.1457-1465, 2009. ,
DOI : 10.1055/s-2004-813279
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.22091/pdf
An octahedral shear strain-based measure of SNR for 3D MR elastography, Physics in medicine and biology 56, p.153, 2011. ,
DOI : 10.1088/0031-9155/56/13/N02
Calculation of shear stiffness in noise dominated magnetic resonance elastography data based on principal frequency estimation, Physics in medicine and biology 56, p.4291, 2011. ,
DOI : 10.1088/0031-9155/56/14/006
Evaluation of wave delivery methodology for brain MRE: Insights from computational simulations, Magnetic Resonance in Medicine, vol.68, issue.1, 2016. ,
DOI : 10.1002/mrm.24141
Magnetic resonance elastography by direct visualization of propagating acoustic strain waves, Science, vol.269, issue.5232, pp.1854-1857, 1995. ,
DOI : 10.1126/science.7569924
Observations of Tissue Response to Acoustic Radiation Force: Opportunities for Imaging, Ultrasonic imaging 24.3, pp.129-138, 2002. ,
DOI : 10.1121/1.396949
Internal displacement and strain imaging using ultrasonic speckle tracking, IEEE transactions on ultrasonics, ferroelectrics, and frequency control 41.3, pp.314-325, 1994. ,
Viscoelastic properties of soft gels: comparison of magnetic resonance elastography and dynamic shear testing in the shear wave regime, Physics in medicine and biology 56, p.6379, 2011. ,
DOI : 10.1088/0031-9155/56/19/014
Complex-valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation, Magnetic resonance in Medicine 45.2, pp.299-310, 2001. ,
DOI : 10.1021/ac60214a047
Elastography: a quantitative method for imaging the elasticity of biological tissues, Ultrasonic imaging 13.2, pp.111-134, 1991. ,
Microscopic magnetic resonance elastography (µMRE) " . In: Magnetic resonance in medicine 54, pp.605-615, 2005. ,
DOI : 10.1002/mrm.20584
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.20584/pdf
Cross-validation of magnetic resonance elastography and ultrasound-based transient elastography: A preliminary phantom study, Journal of Magnetic Resonance Imaging, vol.1, issue.5, pp.1145-1150, 2009. ,
DOI : 10.1016/S0140-6736(86)90837-8
Ultrasound-based transient elastography compared to magnetic resonance elastography in soft tissue-mimicking gels, Physics in Medicine and Biology, vol.54, issue.22, p.6979, 2009. ,
DOI : 10.1088/0031-9155/54/22/015
URL : https://hal.archives-ouvertes.fr/hal-00591475
Comparison of four different techniques to evaluate the elastic properties of phantom in elastography: is there a gold standard? " In: Physics in medicine and biology 59, p.5775, 2014. ,
Acoustic radiation forcebased elasticity imaging methods, Interface Focus, 2011. ,
DOI : 10.1098/rsfs.2011.0023
URL : http://rsfs.royalsocietypublishing.org/content/royfocus/1/4/553.full.pdf
Algebraic Helmholtz inversion in planar magnetic resonance elastography, Physics in medicine and biology 53, p.3147, 2008. ,
DOI : 10.1088/0031-9155/53/12/005
Imaging the elastic properties of tissue: the 20 year perspective, Physics in medicine and biology 56, p.1, 2010. ,
Visualizing tissue compliance with MR imaging, Journal of Magnetic Resonance Imaging, vol.97, issue.6, pp.733-738, 1995. ,
DOI : 10.1148/radiology.173.1.2781015
Applications of magnetic resonance elastography to healthy and pathologic skeletal muscle, Journal of Magnetic Resonance Imaging, vol.106, issue.2, pp.301-309, 2007. ,
DOI : 10.1152/japplphysiol.00775.2002
URL : https://hal.archives-ouvertes.fr/hal-00172315
In vivo waveguide elastography: Effects of neurodegeneration in patients with amyotrophic lateral sclerosis, Magnetic resonance in medicine 72.6, pp.1755-1761, 2014. ,
DOI : 10.1080/10255840802430587
Driver device for MR elastography, US Patent, vol.5, p.952828, 1999. ,
Magnetic resonance elastography of the kidneys: Feasibility and reproducibility in young healthy adults, Journal of Magnetic Resonance Imaging, vol.52, issue.4, pp.880-886, 2011. ,
DOI : 10.1002/mrm.20101
Fractional encoding of harmonic motions in MR elastography, Magnetic Resonance in Medicine, vol.54, issue.2, pp.388-395, 2007. ,
DOI : 10.1002/mrm.21152
MR elastography of prostate cancer: quantitative comparison with histopathology and repeatability of methods, NMR in Biomedicine, vol.59, issue.1, pp.124-139, 2015. ,
DOI : 10.1002/mrm.21465
Early Detection of Steatohepatitis in Fatty Rat Liver by Using MR Elastography, Radiology, vol.253, issue.1, pp.90-97, 2009. ,
DOI : 10.1148/radiol.2523081817
Evaluation of Prostate Cancer Detection with Ultrasound Real-Time Elastography: A Comparison with Step Section Pathological Analysis after Radical Prostatectomy, European urology 54.6, pp.1354-1362, 2008. ,
DOI : 10.1016/j.eururo.2008.02.035
Shear modulus imaging with 2-D transient elastography, IEEE transactions on ultrasonics, ferroelectrics, and frequency control 49.4, pp.426-435, 2002. ,
DOI : 10.1109/58.996560
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis, Ultrasound in medicine & biology 29.12, pp.1705-1713, 2003. ,
DOI : 10.1016/j.ultrasmedbio.2003.07.001
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics, Ultrasound in Medicine & Biology, vol.24, issue.9, pp.1419-1435, 1998. ,
DOI : 10.1016/S0301-5629(98)00110-0
Nonlinear parameter tomography system using counterprop agating probe and pump waves, Ultrasonic Imaging, vol.7, issue.1, pp.49-59, 1985. ,
DOI : 10.1016/0161-7346(85)90015-X
Shear Wave Elastography: A New Ultrasound Imaging Mode for the Differential Diagnosis of Benign and Malignant Thyroid Nodules, The Journal of Clinical Endocrinology & Metabolism, vol.95, issue.12, pp.5281-5288, 2010. ,
DOI : 10.1210/jc.2010-0766
Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays, The Journal of the Acoustical Society of America, vol.75, issue.4, pp.1273-1282, 1984. ,
DOI : 10.1121/1.390734
Real time tissue elasticity imaging using the combined autocorrelation method, Journal of Medical Ultrasonics, vol.32, issue.3, pp.119-128, 2002. ,
DOI : 10.1109/T-SU.1985.31615
A model for image formation in vibro???acoustography, The Journal of the Acoustical Society of America, vol.116, issue.4, 2003. ,
DOI : 10.1121/1.4785010
Magnetic resonance elastography for staging liver fibrosis in non-alcoholic fatty liver disease: a diagnostic accuracy systematic review and individual participant data pooled analysis, European radiology 26.5, pp.1431-1440, 2016. ,
DOI : 10.1016/j.cgh.2013.07.034
High-resolution tensor MR elastography for breast tumour detection, Physics in Medicine and Biology, vol.45, issue.6, p.1649, 2000. ,
DOI : 10.1088/0031-9155/45/6/317
Viscoelastic shear properties of in vivo breast lesions measured by MR elastography, Magnetic resonance imaging 23.2, pp.159-165, 2005. ,
DOI : 10.1016/j.mri.2004.11.060
MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography, Magnetic Resonance in Medicine 58.6, pp.1135-1144, 2007. ,
DOI : 10.1055/s-2002-32690
Visualisation of HIFU lesions using elastography of the human prostate in vivo: preliminary results, Ultrasound in medicine & biology 29.7, pp.1007-1015, 2003. ,
DOI : 10.1016/S0301-5629(03)00065-6
A Meta-analysis of Transient Elastography for the Detection of Hepatic Fibrosis, Journal of Clinical Gastroenterology, vol.44, issue.3, pp.214-219, 2010. ,
DOI : 10.1097/MCG.0b013e3181b4af1f
Ultrasound-based transient elastography for the detection of hepatic fibrosis: systematic review and meta-analysis " . In: Clinical gastroenterology and hepatology 5, pp.1214-1220, 2007. ,
Ultrasound Elastography and MR Elastography for Assessing Liver Fibrosis: Part 2, Diagnostic Performance, Confounders, and Future Directions, American journal of roentgenology 205.1, pp.33-40, 2015. ,
DOI : 10.2214/AJR.15.14553
Élastographie par résonance magnétique et onde de pression guidée, 2014. ,
Piezoelectric actuator design for MR elastography: implementation and vibration issues, The International Journal of Medical Robotics and Computer Assisted Surgery, vol.30, issue.3, pp.353-360, 2011. ,
DOI : 10.1118/1.1556607
Magnetic resonance elastography hardware design: A survey, Proceedings of the Institution of Mechanical Engineers, pp.497-514, 2009. ,
DOI : 10.1053/j.gastro.2008.05.038
Design of an MR-compatible piezoelectric actuator for MR elastography, Concepts in Magnetic Resonance Part A 15, pp.239-254, 2002. ,
DOI : 10.1007/978-1-4615-1943-0_23
In vivo elasticity measurements of extremity skeletal muscle with MR elastography, NMR in Biomedicine, vol.17, issue.4, pp.181-190, 2004. ,
DOI : 10.1002/nbm.887
Comparison Of Shear Velocity Dispersion in Viscoelastic Phantoms Measured by UltrasoundBased Shear Wave Elastography and Magnetic Resonance Elastography, IEEE International Ultrasonics Symposium (IUS), p.2017, 2017. ,
Three-dimensional subzone-based reconstruction algorithm for MR elastography, Magnetic Resonance in Medicine, vol.13, issue.5, pp.827-837, 2001. ,
DOI : 10.3109/02656739709023546
Reliability and applicability of two-dimensional shear-wave elastography for the evaluation of liver stiffness, European Journal of Gastroenterology & Hepatology, vol.28, issue.10, pp.1204-1209, 2016. ,
DOI : 10.1097/MEG.0000000000000686
A theoretical framework for performance characterization of elastography: the strain filter, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.44, issue.1, pp.164-172, 1997. ,
DOI : 10.1109/58.585212
Comparison of liver stiffness with MRE and fibrosis quantification with Fibro-C index in chronic hepatitis B patients, Proceedings of the 19th Annual Meeting of ISMRM, p.2934, 2011. ,
Magnetic Resonance Elastography of Liver, Journal of computer assisted tomography 37.6, p.887, 2013. ,
DOI : 10.1097/RCT.0000000000000032
Real-time imaging of tissue vibration using a twodimensional speckle tracking system, Ultrasonics Symposium, vol.2, issue.1, pp.873-873, 1991. ,
Identification of the prostate cancer index lesion by real-time elastography: considerations for focal therapy of prostate cancer, World Journal of Urology, vol.74, issue.5, pp.589-594, 2011. ,
DOI : 10.1016/j.urology.2009.04.102
Multicenter Study of Ultrasound Real-Time Tissue Elastography in 779 Cases for??the Assessment of Breast Lesions: Improved Diagnostic Performance by Combining the BI-RADS??-US Classification System with Sonoelastography, Ultraschall in der Medizin-European Journal of Ultrasound 31.05, pp.484-491, 2010. ,
DOI : 10.1055/s-0029-1245282
A phantom study to cross-validate multimodality shear wave elastography techniques, 2012 IEEE International Ultrasonics Symposium, pp.1858-1861, 2012. ,
DOI : 10.1109/ULTSYM.2012.0466
Wideband MR elastography for viscoelasticity model identification, Magnetic resonance in medicine 70.2, pp.479-489, 2013. ,
DOI : 10.1088/0031-9155/53/8/008
URL : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3556381/pdf
Shear-wave elasticity imaging of a liver fibrosis mouse model using high-frequency ultrasound, IEEE transactions on ultrasonics, ferroelectrics, and frequency control 62.7, pp.1295-1307, 2015. ,
DOI : 10.1109/TUFFC.2014.006953
Ultrasound or MR elastography??of liver: which one shall I use?, Abdominal Radiology, vol.277, issue.2, pp.1-6, 2017. ,
DOI : 10.1148/radiol.2015151075
Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography, Clinical Gastroenterology and Hepatology, vol.5, issue.10, pp.1207-1213, 2007. ,
DOI : 10.1016/j.cgh.2007.06.012
Hepatic MR Elastography: Clinical Performance in a Series of 1377 Consecutive Examinations, Radiology, vol.278, issue.1, pp.114-124, 2015. ,
DOI : 10.1148/radiol.2015142141
Staging of Hepatic Fibrosis: Comparison of Magnetic Resonance Elastography and Shear Wave Elastography in the Same Individuals, Korean Journal of Radiology, vol.14, issue.2, pp.202-212, 2013. ,
DOI : 10.3348/kjr.2013.14.2.202
Short-Term Repeatability of Magnetic Resonance Elastography at 3.0 T: Effects of Motion-Encoding Gradient Direction, Slice Position, and Meal Ingestion, Journal of Magnetic Resonance Imaging, 2015. ,