P. J. Marriott, P. Schoenmakers, and Z. Wu, Nomenclature and conventions in comprehensive multidimensional chromatography ? an update, LC GC Eur, vol.25, 2012.

G. Guiochon, The limits of the separation power of unidimensional column liquid chromatography, Journal of Chromatography A, vol.1126, issue.1-2, pp.6-49, 2006.
DOI : 10.1016/j.chroma.2006.07.032

X. Zhang, A. Fang, C. P. Riley, M. Wang, F. E. Regnier et al., Multi-dimensional liquid chromatography in proteomics???A review, Analytica Chimica Acta, vol.664, issue.2, pp.101-113, 2010.
DOI : 10.1016/j.aca.2010.02.001

P. Donato, F. Cacciola, L. Mondello, and P. Dugo, Comprehensive chromatographic separations in proteomics, Journal of Chromatography A, vol.1218, issue.49, pp.8777-8790, 2011.
DOI : 10.1016/j.chroma.2011.05.070

I. François, K. Sandra, and P. Sandra, Comprehensive liquid chromatography: Fundamental aspects and practical considerations???A review, Analytica Chimica Acta, vol.641, issue.1-2, pp.14-31, 2009.
DOI : 10.1016/j.aca.2009.03.041

P. Dugo, F. Cacciola, T. Kumm, G. Dugo, and L. Mondello, Comprehensive multidimensional liquid chromatography: Theory and applications, Journal of Chromatography A, vol.1184, issue.1-2, pp.353-368, 2008.
DOI : 10.1016/j.chroma.2007.06.074

G. Guiochon, N. Marchetti, K. Mriziq, and R. A. Shalliker, Implementations of two-dimensional liquid chromatography, Journal of Chromatography A, vol.1189, issue.1-2, pp.109-168, 2008.
DOI : 10.1016/j.chroma.2008.01.086

D. R. Stoll, X. Li, X. Wang, P. W. Carr, S. E. Porter et al., Fast, comprehensive two-dimensional liquid chromatography, Journal of Chromatography A, vol.1168, issue.1-2, pp.3-43, 2007.
DOI : 10.1016/j.chroma.2007.08.054

URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3205947

P. Jandera, Programmed elution in comprehensive two-dimensional liquid chromatography, Journal of Chromatography A, vol.1255, pp.112-129, 2012.
DOI : 10.1016/j.chroma.2012.02.071

J. C. Giddings, Maximum number of components resolvable by gel filtration and other elution chromatographic methods, Analytical Chemistry, vol.39, issue.8, pp.1027-1028, 1967.
DOI : 10.1021/ac60252a025

U. D. Neue, Theory of peak capacity in gradient elution, Journal of Chromatography A, vol.1079, issue.1-2, pp.153-161, 2005.
DOI : 10.1016/j.chroma.2005.03.008

J. W. Dolan, L. R. Snyder, N. M. Djordjevic, D. W. Hill, and T. J. Waeghe, Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time, Journal of Chromatography A, vol.857, issue.1-2, pp.1-2010, 1999.
DOI : 10.1016/S0021-9673(99)00765-7

L. R. Snyder, J. W. Dolan, and J. R. Gant, Gradient elution in high-performance liquid chromatography, Journal of Chromatography A, vol.165, issue.1, pp.3-30, 1979.
DOI : 10.1016/S0021-9673(00)85726-X

A. D. Attoma, C. Grivel, and S. Heinisch, On-line comprehensive two-dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part I: orthogonality and practical peak capacity considerations, J. Chromatogr. A, vol.1262, pp.148-159, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00876061

J. M. Davis, D. R. Stoll, and P. W. Carr, Effect of First-Dimension Undersampling on Effective Peak Capacity in Comprehensive Two-Dimensional Separations, Analytical Chemistry, vol.80, issue.2, pp.461-47310, 2008.
DOI : 10.1021/ac071504j

F. Bedani, P. J. Schoenmakers, and H. Janssen, Theories to support method development in comprehensive two-dimensional liquid chromatography - A review, Journal of Separation Science, vol.29, issue.14, pp.1697-1711, 2012.
DOI : 10.1002/jssc.201200070

G. Vivó-truyols, S. Van-der-wal, and P. J. Schoenmakers, Comprehensive Study on the Optimization of Online Two-Dimensional Liquid Chromatographic Systems Considering Losses in Theoretical Peak Capacity in First- and Second-Dimensions: A Pareto-Optimality Approach, Analytical Chemistry, vol.82, issue.20, pp.8525-853610, 1021.
DOI : 10.1021/ac101420f

Z. Liu, D. G. Patterson, and M. L. Lee, Geometric Approach to Factor Analysis for the Estimation of Orthogonality and Practical Peak Capacity in Comprehensive Two-Dimensional Separations, Analytical Chemistry, vol.67, issue.21, pp.3840-384510, 1995.
DOI : 10.1021/ac00117a004

M. Gilar, P. Olivova, A. E. Daly, and J. C. Gebler, Orthogonality of Separation in Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.77, issue.19, pp.6426-643410, 2005.
DOI : 10.1021/ac050923i

R. E. Murphy, M. R. Schure, and J. P. Foley, Effect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.70, issue.8, pp.1585-159410, 1998.
DOI : 10.1021/ac971184b

K. Horie, H. Kimura, T. Ikegami, A. Iwatsuka, N. Saad et al., Calculating Optimal Modulation Periods to Maximize the Peak Capacity in Two-Dimensional HPLC, Analytical Chemistry, vol.79, issue.10, pp.3764-377010, 1021.
DOI : 10.1021/ac062002t

C. Grivel, J. Rocca, D. Guillarme, J. Veuthey, and S. Heinisch, Selection of suitable operating conditions to minimize the gradient equilibration time in the separation of drugs by Ultra-High-Pressure Liquid Chromatography with volatile (mass spectrometry-compatible) buffers, Journal of Chromatography A, vol.1217, issue.4, pp.459-472, 2010.
DOI : 10.1016/j.chroma.2009.11.059

A. P. Schellinger, D. R. Stoll, and P. W. Carr, High-speed gradient elution reversed-phase liquid chromatography of bases in buffered eluents, Journal of Chromatography A, vol.1192, issue.1, pp.41-53, 2008.
DOI : 10.1016/j.chroma.2008.01.062

A. P. Schellinger, D. R. Stoll, and P. W. Carr, High speed gradient elution reversed phase liquid chromatography of bases in buffered eluents, Journal of Chromatography A, vol.1192, issue.1, pp.54-61, 2008.
DOI : 10.1016/j.chroma.2008.02.049

S. Heinisch, Chapter 4. Using Elevated Temperature in UHPLC: Interest and Limitations, UHPLC in Life Sciences, pp.102-130
DOI : 10.1039/9781849735490-00102

S. Heinisch and J. Rocca, Sense and nonsense of high-temperature liquid chromatography, Journal of Chromatography A, vol.1216, issue.4, pp.642-658, 2009.
DOI : 10.1016/j.chroma.2008.11.079

]. X. Li, D. R. Stoll, and P. W. Carr, Equation for Peak Capacity Estimation in Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.81, issue.2, pp.845-85010, 2009.
DOI : 10.1021/ac801772u

J. C. Sternberg, Extracolumn contributions to chromatography band broadening, Advances in Chromatography, vol.2, p.205, 1966.

P. Jandera, P. C. ?-esla, T. Hájek, G. Vohralík, K. Vy?-uchalová et al., Optimization of separation in two-dimensional high-performance liquid chromatography by adjusting phase system selectivity and using programmed elution techniques, Journal of Chromatography A, vol.1189, issue.1-2, pp.207-220, 2008.
DOI : 10.1016/j.chroma.2007.11.053

J. Lankelma and H. Poppe, Determination of methotrexate in plasma by on-column concentration and ion-exchange chromatography, Journal of Chromatography A, vol.149, issue.00, pp.587-59810, 1978.
DOI : 10.1016/S0021-9673(00)81013-4

M. R. Filgueira, Y. Huang, K. Witt, C. Castells, and P. W. Carr, Improving Peak Capacity in Fast Online Comprehensive Two-Dimensional Liquid Chromatography with Post-First-Dimension Flow Splitting, Analytical Chemistry, vol.83, issue.24, pp.9531-953910, 1021.
DOI : 10.1021/ac202317m

M. R. Schure, Limit of Detection, Dilution Factors, and Technique Compatibility in Multidimensional Separations Utilizing Chromatography, Capillary Electrophoresis, and Field-Flow Fractionation, Analytical Chemistry, vol.71, issue.8, pp.1645-165710, 1999.
DOI : 10.1021/ac981128q

K. Horváth, J. N. Fairchild, and G. Guiochon, Detection issues in two-dimensional on-line chromatography, Journal of Chromatography A, vol.1216, issue.45, pp.7785-7792, 2009.
DOI : 10.1016/j.chroma.2009.09.016

H. Gu, Y. Huang, and P. W. Carr, Peak capacity optimization in comprehensive two dimensional liquid chromatography: A practical approach, Journal of Chromatography A, vol.1218, issue.1, pp.64-73, 2011.
DOI : 10.1016/j.chroma.2010.10.096

P. J. Schoenmakers, G. Vivó-truyols, and W. M. Decrop, A protocol for designing comprehensive two-dimensional liquid chromatography separation systems, Journal of Chromatography A, vol.1120, issue.1-2, pp.282-290, 2006.
DOI : 10.1016/j.chroma.2005.11.039

P. Jandera, T. Hájek, M. Sta?-ková, K. Vy?-uchalová, and P. , Optimization of comprehensive two-dimensional gradient chromatography coupling in-line hydrophilic interaction and reversed phase liquid chromatography, Journal of Chromatography A, vol.1268, pp.91-101, 2012.
DOI : 10.1016/j.chroma.2012.10.041

K. M. Kalili and A. De-villiers, Systematic optimisation and evaluation of on-line, off-line and stop-flow comprehensive hydrophilic interaction chromatography??reversed phase liquid chromatographic analysis of procyanidins, Part I: Theoretical considerations, Journal of Chromatography A, vol.1289, pp.58-68, 2013.
DOI : 10.1016/j.chroma.2013.03.008

P. Dugo, N. Fawzy, F. Cichello, F. Cacciola, P. Donato et al., Stop-flow comprehensive two-dimensional liquid chromatography combined with mass spectrometric detection for phospholipid analysis, Journal of Chromatography A, vol.1278, pp.46-53, 2013.
DOI : 10.1016/j.chroma.2012.12.042

S. Wang, J. Li, X. Shi, L. Qiao, X. Lu et al., A novel stop-flow two-dimensional liquid chromatography???mass spectrometry method for lipid analysis, Journal of Chromatography A, vol.1321, pp.65-72, 2013.
DOI : 10.1016/j.chroma.2013.10.069

K. M. Kalili and A. De-villiers, Systematic optimisation and evaluation of on-line, off-line and stop-flow comprehensive hydrophilic interaction chromatography??reversed phase liquid chromatographic analysis of procyanidins. Part II: Application to cocoa procyanidins, Journal of Chromatography A, vol.1289, pp.69-79, 2013.
DOI : 10.1016/j.chroma.2013.03.009

F. Bedani, W. T. Kok, and H. Janssen, A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography??liquid chromatography, Journal of Chromatography A, vol.1133, issue.1-2, pp.126-134, 2006.
DOI : 10.1016/j.chroma.2006.08.048

N. Tanaka, H. Kimura, D. Tokuda, K. Hosoya, T. Ikegami et al., Simple and Comprehensive Two-Dimensional Reversed-Phase HPLC Using Monolithic Silica Columns, Analytical Chemistry, vol.76, issue.5, pp.1273-128110, 2004.
DOI : 10.1021/ac034925j

E. Machtejevas, H. John, K. Wagner, L. Ständker, G. Marko-varga et al., Automated multi-dimensional liquid chromatography: sample preparation and identification of peptides from human blood filtrate, Journal of Chromatography B, vol.803, issue.1, pp.121-130, 2004.
DOI : 10.1016/j.jchromb.2003.07.015

I. François, D. Cabooter, K. Sandra, F. Lynen, G. Desmet et al., Tryptic digest analysis by comprehensive reversed phase??two reversed phase liquid chromatography (RP-LC??2RP-LC) at different pH's, Journal of Separation Science, vol.80, issue.8, pp.1137-1144, 2009.
DOI : 10.1002/jssc.200800578

C. J. Venkatramani and Y. Zelechonok, An Automated Orthogonal Two-Dimensional Liquid Chromatograph, Analytical Chemistry, vol.75, issue.14, pp.3484-349410, 2003.
DOI : 10.1021/ac030075w

I. François, A. De-villiers, B. Tienpont, F. David, and P. Sandra, Comprehensive two-dimensional liquid chromatography applying two parallel columns in the second dimension, Journal of Chromatography A, vol.1178, issue.1-2, pp.33-42, 2008.
DOI : 10.1016/j.chroma.2007.11.032

A. Felinger, M. Kele, and G. Guiochon, Identification of the factors that influence the reproducibility of chromatographic retention data, Journal of Chromatography A, vol.913, issue.1-2, pp.23-4810, 2001.
DOI : 10.1016/S0021-9673(00)01044-X

D. R. Stoll and P. W. Carr, Fast, Comprehensive Two-Dimensional HPLC Separation of Tryptic Peptides Based on High-Temperature HPLC, Journal of the American Chemical Society, vol.127, issue.14, pp.5034-503510, 2005.
DOI : 10.1021/ja050145b

D. R. Stoll, J. D. Cohen, and P. W. Carr, Fast, comprehensive online two-dimensional high performance liquid chromatography through the use of high temperature ultra-fast gradient elution reversed-phase liquid chromatography, Journal of Chromatography A, vol.1122, issue.1-2, pp.123-137, 2006.
DOI : 10.1016/j.chroma.2006.04.058

A. Ginzburg, T. Macko, F. Malz, M. Schroers, I. Troetsch-schaller et al., Characterization of functionalized polyolefins by high-temperature two-dimensional liquid chromatography, Journal of Chromatography A, vol.1285, pp.40-47, 2013.
DOI : 10.1016/j.chroma.2013.01.067

M. Kivilompolo and T. Hyötyläinen, Comparison of separation power of ultra performance liquid chromatography and comprehensive two-dimensional liquid chromatography in the separation of phenolic compounds in beverages, Journal of Separation Science, vol.399, issue.19
DOI : 10.1002/jssc.200800287

F. Cacciola, P. Delmonte, K. Jaworska, P. Dugo, L. Mondello et al., Employing ultra high pressure liquid chromatography as the second dimension in a comprehensive two-dimensional system for analysis of Stevia rebaudiana extracts, Journal of Chromatography A, vol.1218, issue.15, pp.2012-2018, 2011.
DOI : 10.1016/j.chroma.2010.08.081

T. Beelders, K. M. Kalili, E. Joubert, D. De-beer, and A. De-villiers, Comprehensive two-dimensional liquid chromatographic analysis of rooibos (Aspalathus linearis) phenolics, Journal of Separation Science, vol.1216, issue.14, pp.1808-1820, 2012.
DOI : 10.1002/jssc.201200060

F. Cacciola, P. Donato, D. Giuffrida, G. Torre, P. Dugo et al., Ultra high pressure in the second dimension of a comprehensive two-dimensional liquid chromatographic system for carotenoid separation in red chili peppers, Journal of Chromatography A, vol.1255, pp.244-251, 2012.
DOI : 10.1016/j.chroma.2012.06.076

A. D. Attoma and S. Heinisch, On-line comprehensive two dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part II: application to the separation of peptides, J. Chromatogr. A, vol.1306, pp.27-36, 2013.
URL : https://hal.archives-ouvertes.fr/hal-00876061

A. Le-masle, D. Angot, C. Gouin, A. D. Attoma, J. Ponthus et al., Development of on-line comprehensive two-dimensional liquid chromatography method for the separation of biomass compounds, Journal of Chromatography A, vol.1340, 2014.
DOI : 10.1016/j.chroma.2014.03.020

URL : https://hal.archives-ouvertes.fr/hal-00991030

A. Van-der-horst and P. J. Schoenmakers, Comprehensive two-dimensional liquid chromatography of polymers, Journal of Chromatography A, vol.1000, issue.1-2, pp.693-70910, 2003.
DOI : 10.1016/S0021-9673(03)00495-3

K. Horie, Y. Sato, T. Kimura, T. Nakamura, Y. Ishihama et al., Estimation and optimization of the peak capacity of one-dimensional gradient high performance liquid chromatography using a long monolithic silica capillary column, Journal of Chromatography A, vol.1228, pp.283-291, 2012.
DOI : 10.1016/j.chroma.2011.12.088

P. Donato, F. Cacciola, E. Sommella, C. Fanali, L. Dugo et al., Online Comprehensive RPLC ?? RPLC with Mass Spectrometry Detection for the Analysis of Proteome Samples, Analytical Chemistry, vol.83, issue.7, pp.2485-249110, 1021.
DOI : 10.1021/ac102656b

E. Uliyanchenko, P. J. Cools, S. Van-der-wal, and P. J. Schoenmakers, Comprehensive Two-Dimensional Ultrahigh-Pressure Liquid Chromatography for Separations of Polymers, Analytical Chemistry, vol.84, issue.18, pp.7802-780910, 2012.
DOI : 10.1021/ac3011582

J. M. Davis, D. R. Stoll, and P. W. Carr, Effect of First-Dimension Undersampling on Effective Peak Capacity in Comprehensive Two-Dimensional Separations, Analytical Chemistry, vol.80, issue.2, 2008.
DOI : 10.1021/ac071504j

X. Li, D. R. Stoll, and P. W. Carr, Equation for Peak Capacity Estimation in Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.81, issue.2, 2009.
DOI : 10.1021/ac801772u

H. Gu, Y. Huang, and P. W. Carr, Peak capacity optimization in comprehensive two dimensional liquid chromatography: A practical approach, Journal of Chromatography A, vol.1218, issue.1, 2011.
DOI : 10.1016/j.chroma.2010.10.096

P. J. Schoenmakers, G. Vivó-truyols, and W. M. Decrop, A protocol for designing comprehensive two-dimensional liquid chromatography separation systems, Journal of Chromatography A, vol.1120, issue.1-2, 2006.
DOI : 10.1016/j.chroma.2005.11.039

K. Horie, H. Kimura, T. Ikegami, A. Iwatsuka, N. Saad et al., Calculating Optimal Modulation Periods to Maximize the Peak Capacity in Two-Dimensional HPLC, Analytical Chemistry, vol.79, issue.10, 2007.
DOI : 10.1021/ac062002t

F. Bedani, P. J. Schoenmakers, and H. Janssen, Theories to support method development in comprehensive two-dimensional liquid chromatography - A review, Journal of Separation Science, vol.29, issue.14
DOI : 10.1002/jssc.201200070

M. Sarrut, G. Crétier, and S. Heinisch, Theoretical and practical interest in UHPLC technology for 2D-LC, TrAC Trends in Analytical Chemistry, vol.63
DOI : 10.1016/j.trac.2014.08.005

URL : https://hal.archives-ouvertes.fr/hal-01230120

S. -truyols, P. J. Van-der-wal, and . Schoenmakers, Comprehensive Study on the Optimization of Online Two-Dimensional Liquid Chromatographic Systems Considering Losses in Theoretical Peak Capacity in First-and Second- Dimensions: A Pareto-Optimality Approach, Anal. Chem, vol.82, 2010.

B. G. Massart, L. M. Buydens, S. De-jong, P. J. Lewi, and J. Smeyers-verbeke, Chapter 26 Other optimization methods, Data Handl. Sci. Technol, pp.771804-0922348797800561, 1998.

B. W. Pirok, S. Pous-torres, C. Ortiz-bolsico, G. Vivó-truyols, and P. J. Schoenmakers, Program for the interpretive optimization of two-dimensional resolution, Journal of Chromatography A, vol.1450
DOI : 10.1016/j.chroma.2016.04.061

M. R. Schure, Quantification of resolution for two-dimensional separations, 3<169::AID-MCS5>3.0.CO;2-#, pp.1520-667, 1997.
DOI : 10.1002/(SICI)1520-667X(1997)9:3<169::AID-MCS5>3.0.CO;2-#

D. R. Stoll, X. Wang, and P. W. Carr, Comparison of the Practical Resolving Power of One- and Two-Dimensional High-Performance Liquid Chromatography Analysis of Metabolomic Samples, Analytical Chemistry, vol.80, issue.1, 2008.
DOI : 10.1021/ac701676b

Y. Huang, H. Gu, M. Filgueira, and P. W. Carr, An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance Chapitre 1 : Contexte, p.27

L. W. Potts and P. W. Carr, Analysis of the temporal performance of one versus online comprehensive two-dimensional liquid chromatography, J. Chromatogr. A

X. Wang, D. R. Stoll, P. W. Carr, and P. J. Schoenmakers, A graphical method for understanding the kinetics of peak capacity production in gradient elution liquid chromatography16] -line comprehensive two dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part II: Application to the separation of peptides, J. Chromatogr. A. J. Chromatogr. A, vol.1125, p.1306, 2006.

Q. Li, F. Lynen, J. Wang, H. Li, G. Xu et al., Comprehensive hydrophilic interaction and ion-pair reversed-phase liquid chromatography for analysis of di-to deca-oligonucleotides and solvent on the separation in very fast gradients, with special attention to the second-dimension gradient in comprehensive two-dimensional liquid chromatography, J. Chromatogr. A. J. Chromatogr. A, p.1218, 2011.

A. Medvedovici, V. David, V. David, and C. Georgita, Retention Phenomena Induced by Large Volume Injection of Solvents NonMiscible with the Mobile Phase in ReversedPhase Liquid Chromatography, J. Liq. Chromatogr. Relat. Technol, vol.30, p.10, 1080.

I. François, A. De-villiers, and P. Sandra, Considerations on the possibilities and limitations of comprehensive normal phasereversed phase liquid chromatography (NPLC×RPLC), J. Sep. Sci, vol.29, 2006.

K. J. Mayfield, R. A. Shalliker, H. J. Catchpoole, A. P. Sweeney, V. Wong et al., Viscous fingering induced flow instability in multidimensional liquid chromatography, Journal of Chromatography A, vol.1080, issue.2, 2005.
DOI : 10.1016/j.chroma.2005.04.093

R. A. Shalliker and G. Guiochon, Understanding the importance of the viscosity contrast between the sample solvent plug and the mobile phase and its potential consequence in two-dimensional high-performance liquid chromatography, Journal of Chromatography A, vol.1216, issue.5, 2009.
DOI : 10.1016/j.chroma.2008.11.067

M. R. Filgueira, Y. Huang, K. Witt, C. Castells, and P. W. Carr, Improving Peak Capacity in Fast Online Comprehensive Two-Dimensional Liquid Chromatography with Post-First-Dimension Flow Splitting, Analytical Chemistry, vol.83, issue.24, pp.95319539-95319549, 2011.
DOI : 10.1021/ac202317m

T. Beelders, K. M. Kalili, E. Joubert, D. De-beer, and A. De-villiers, Comprehensive two-dimensional liquid chromatographic analysis of rooibos (Aspalathus linearis) phenolics, Journal of Separation Science, vol.1216, issue.14
DOI : 10.1002/jssc.201200060

P. Q. Tranchida, P. Donato, F. Cacciola, M. Beccaria, P. Dugo et al., Potential of comprehensive chromatography in food analysis, TrAC Trends in Analytical Chemistry, vol.52, pp.186-205, 2013.
DOI : 10.1016/j.trac.2013.07.008

M. Sarrut, G. Crétier, and S. Heinisch, Theoretical and practical interest in UHPLC technology for 2D-LC, TrAC Trends in Analytical Chemistry, vol.63, pp.104-112, 2014.
DOI : 10.1016/j.trac.2014.08.005

URL : https://hal.archives-ouvertes.fr/hal-01230120

D. Li, C. Jakob, and O. Schmitz, Practical considerations in comprehensive two-dimensional liquid chromatography systems (LCxLC) with reversed-phases in both dimensions, Analytical and Bioanalytical Chemistry, vol.97, issue.896, pp.153-167, 2014.
DOI : 10.1007/s00216-014-8179-8

P. F. Vanbel and P. J. Schoenmakers, Selection of adequate optimization criteria in chromatographic separations, Analytical and Bioanalytical Chemistry, vol.1120, issue.5, pp.1283-1289, 2009.
DOI : 10.1007/s00216-009-2709-9

U. D. Neue, Theory of peak capacity in gradient elution, Journal of Chromatography A, vol.1079, issue.1-2, pp.153-161, 2005.
DOI : 10.1016/j.chroma.2005.03.008

H. Poppe, Some reflections on speed and efficiency of modern chromatographic methods, Journal of Chromatography A, vol.778, issue.1-2, pp.3-21, 1997.
DOI : 10.1016/S0021-9673(97)00376-2

G. Desmet, D. Clicq, and P. , Geometry-Independent Plate Height Representation Methods for the Direct Comparison of the Kinetic Performance of LC Supports with a Different Size or Morphology, Analytical Chemistry, vol.77, issue.13, pp.4058-4070, 2005.
DOI : 10.1021/ac050160z

X. Wang, D. R. Stoll, P. W. Carr, and P. J. Schoenmakers, A graphical method for understanding the kinetics of peak capacity production in gradient elution liquid chromatography, Journal of Chromatography A, vol.1125, issue.2, pp.177-181, 2006.
DOI : 10.1016/j.chroma.2006.05.048

J. P. Bounine, G. Guiochon, and H. Colin, A simple pragmatic optimization procedurer for some parameters involved in high-performance liquisd chromatographic matographic separations: column design, temperature, solvent flow-rate and composition, Journal of Chromatography A, vol.298, issue.01, pp.1-20, 1984.
DOI : 10.1016/S0021-9673(01)92691-3

F. Bedani, P. J. Schoenmakers, and H. Janssen, Theories to support method development in comprehensive two-dimensional liquid chromatography - A review, Journal of Separation Science, vol.29, issue.14, pp.1697-1711, 2012.
DOI : 10.1002/jssc.201200070

P. J. Schoenmakers, G. Vivó-truyols, and W. M. Decrop, A protocol for designing comprehensive two-dimensional liquid chromatography separation systems, Journal of Chromatography A, vol.1120, issue.1-2, pp.282-290, 2006.
DOI : 10.1016/j.chroma.2005.11.039

H. Gu, Y. Huang, and P. W. Carr, Peak capacity optimization in comprehensive two dimensional liquid chromatography: A practical approach, Journal of Chromatography A, vol.1218, issue.1, pp.64-73, 2011.
DOI : 10.1016/j.chroma.2010.10.096

G. Vivoí-truyols, S. Van-der-wal, and P. J. Schoenmakers, Comprehensive Study on the Optimization of Online Two-Dimensional Liquid Chromatographic Systems Considering Losses in Theoretical Peak Capacity in First- and Second-Dimensions: A Pareto-Optimality Approach, Analytical Chemistry, vol.82, issue.20, pp.8525-8536, 2010.
DOI : 10.1021/ac101420f

D. J. Vanhoutte, G. Vivó-truyols, and P. J. Schoenmakers, Pareto-optimality study into the comparison of the separation potential of comprehensive two-dimensional liquid chromatography in the column and spatial modes, Journal of Chromatography A, vol.1235, pp.39-48, 2012.
DOI : 10.1016/j.chroma.2012.01.059

K. Horváth, J. N. Fairchild, and G. Guiochon, Generation and Limitations of Peak Capacity in Online Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.81, issue.10, pp.3879-3888, 2009.
DOI : 10.1021/ac802694c

X. Li, D. R. Stoll, and P. W. Carr, Equation for Peak Capacity Estimation in Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.81, issue.2, pp.845-850, 2009.
DOI : 10.1021/ac801772u

A. D. 'attoma, C. Grivel, S. Heinisch, A. D-'attoma, and S. Heinisch, On-line comprehensive two-dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part I: Orthogonality and practical peak capacity considerations On-line comprehensive two dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part II: Application to the separation of peptides, J. Chromatogr. A J. Chromatogr. A, vol.1262, issue.1306, pp.148-159, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00876061

L. R. Snyder, J. W. Dolan, and J. R. Gant, Gradient elution in high-performance liquid chromatography, Journal of Chromatography A, vol.165, issue.1, pp.3-30, 1979.
DOI : 10.1016/S0021-9673(00)85726-X

J. M. Davis, D. R. Stoll, and P. W. Carr, Effect of First-Dimension Undersampling on Effective Peak Capacity in Comprehensive Two-Dimensional Separations, Analytical Chemistry, vol.80, issue.2, pp.461-473, 2008.
DOI : 10.1021/ac071504j

J. C. Sternberg, P. Jandera, P. Cesla, T. Hájek, G. Vohralík et al., Optimization of separation in two-dimensional high-performance liquid chromatography by adjusting phase system selectivity and using programmed elution techniques, Advances in Chromatography, pp.205-207, 1966.

J. Lankelma and H. Poppe, Determination of methotrexate in plasma by on-column concentration and ion-exchange chromatography, Journal of Chromatography A, vol.149, issue.00, pp.587-598, 1978.
DOI : 10.1016/S0021-9673(00)81013-4

F. Gritti, C. A. Sanchez, T. Farkas, and G. Guiochon, Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments, Journal of Chromatography A, vol.1217, issue.18, pp.3000-3012, 2010.
DOI : 10.1016/j.chroma.2010.02.044

A. C. Sanchez, J. A. Anspach, and T. Farkas, Performance optimizing injection sequence for minimizing injection band broadening contributions in high efficiency liquid chromatographic separations, Journal of Chromatography A, vol.1228, pp.338-348, 2012.
DOI : 10.1016/j.chroma.2012.01.038

M. R. Filgueira, Y. Huang, K. Witt, C. Castells, and P. W. Carr, Improving Peak Capacity in Fast Online Comprehensive Two-Dimensional Liquid Chromatography with Post-First-Dimension Flow Splitting, Analytical Chemistry, vol.83, issue.24, pp.9531-9539, 2011.
DOI : 10.1021/ac202317m

M. R. Schure, Limit of Detection, Dilution Factors, and Technique Compatibility in Multidimensional Separations Utilizing Chromatography, Capillary Electrophoresis, and Field-Flow Fractionation, Analytical Chemistry, vol.71, issue.8, pp.1645-1657, 1999.
DOI : 10.1021/ac981128q

D. R. Stoll, E. S. Talus, D. C. Harmes, and K. Zhang, Evaluation of detection sensitivity in comprehensive two-dimensional liquid chromatography separations of an active pharmaceutical ingredient and its degradants, Analytical and Bioanalytical Chemistry, vol.1168, issue.1, pp.265-277, 2014.
DOI : 10.1007/s00216-014-8036-9

S. Heinisch, G. Desmet, D. Clicq, and J. Rocca, Kinetic plot equations for evaluating the real performance of the combined use of high temperature and ultra-high pressure in liquid chromatography, Journal of Chromatography A, vol.1203, issue.2, pp.124-136, 2008.
DOI : 10.1016/j.chroma.2008.07.039

M. A. Stadalius, H. S. Gold, and L. R. Snyder, Optimization model for the gradient elution separation of peptide mixtures by reversed-phase high-performance liquid chromatography, Journal of Chromatography A, vol.296, issue.01, pp.31-59, 1984.
DOI : 10.1016/S0021-9673(01)96400-3

D. Guillarme, S. Heinisch, and J. L. Rocca, Effect of temperature in reversed phase liquid chromatography, Journal of Chromatography A, vol.1052, issue.1-2, pp.39-51, 2004.
DOI : 10.1016/j.chroma.2004.08.052

A. Le-masle, D. Angot, C. Gouin, A. D. 'attoma, J. Ponthus et al., Development of on-line comprehensive two-dimensional liquid chromatography method for the separation of biomass compounds, Journal of Chromatography A, vol.1340, pp.90-98, 2014.
DOI : 10.1016/j.chroma.2014.03.020

URL : https://hal.archives-ouvertes.fr/hal-00991030

R. E. Murphy, M. R. Schure, and J. P. Foley, Effect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.70, issue.8, pp.1585-1594, 1998.
DOI : 10.1021/ac971184b

K. Horie, H. Kimura, T. Ikegami, A. Iwatsuka, N. Saad et al., Calculating Optimal Modulation Periods to Maximize the Peak Capacity in Two-Dimensional HPLC, Analytical Chemistry, vol.79, issue.10, pp.3764-3770, 2007.
DOI : 10.1021/ac062002t

M. Gilar, A. E. Daly, M. Kele, U. D. Neue, and J. C. Gebler, Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography, Journal of Chromatography A, vol.1061, issue.2, pp.183-192, 2004.
DOI : 10.1016/j.chroma.2004.10.092

S. Heinisch, A. D-'attoma, and C. , Effect of pH additive and column temperature on kinetic performance of two different sub-2?m stationary phases for ultrafast separation of charged analytes, Journal of Chromatography A, vol.1228, pp.135-147, 2012.
DOI : 10.1016/j.chroma.2011.08.041

URL : https://hal.archives-ouvertes.fr/hal-00704052

J. E. Macnair, K. D. Patel, and J. W. Jorgenson, Ultrahigh-Pressure Reversed-Phase Capillary Liquid Chromatography:?? Isocratic and Gradient Elution Using Columns Packed with 1.0-??m Particles, Analytical Chemistry, vol.71, issue.3, pp.700-708, 1999.
DOI : 10.1021/ac9807013

J. Ruta, D. Guillarme, S. Rudaz, and J. Veuthey, Comparison of columns packed with porous sub-2?????m particles and superficially porous sub-3?????m particles for peptide analysis at ambient and high temperature, Journal of Separation Science, vol.77, issue.16, pp.2465-2477, 2010.
DOI : 10.1002/jssc.201000023

P. J. Eugster, D. Biass, D. Guillarme, P. Favreau, R. Stöcklin et al., Peak capacity optimisation for high resolution peptide profiling in complex mixtures by liquid chromatography coupled to time-of-flight mass spectrometry: Application to the Conus consors cone snail venom, Journal of Chromatography A, vol.1259, pp.187-199, 2012.
DOI : 10.1016/j.chroma.2012.05.033

J. De-vos, C. Stassen, A. Vaast, G. Desmet, and S. Eeltink, High-resolution separations of tryptic digest mixtures using core???shell particulate columns operated at 1200bar, Journal of Chromatography A, vol.1264, pp.57-62, 2012.
DOI : 10.1016/j.chroma.2012.09.065

R. Shen, R. J. Zhang, J. Moore, T. O. Kim, K. K. Metz et al., Automated 20 kpsi RPLC-MS and MS/MS with Chromatographic Peak Capacities of 1000???1500 and Capabilities in Proteomics and Metabolomics, Analytical Chemistry, vol.77, issue.10, pp.3090-3100, 2005.
DOI : 10.1021/ac0483062

K. Horie, Y. Sato, T. Kimura, T. Nakamura, Y. Ishihama et al., Estimation and optimization of the peak capacity of one-dimensional gradient high performance liquid chromatography using a long monolithic silica capillary column, Journal of Chromatography A, vol.1228, pp.283-291, 2012.
DOI : 10.1016/j.chroma.2011.12.088

P. Q. Tranchida, P. Donato, F. Cacciola, M. Beccaria, P. Dugo et al., Potential of comprehensive chromatography in food analysis, TrAC Trends in Analytical Chemistry, vol.52, pp.186-205, 2013.
DOI : 10.1016/j.trac.2013.07.008

M. Sarrut, G. Crétier, and S. Heinisch, Theoretical and practical interest in UHPLC technology for 2D-LC, TrAC Trends in Analytical Chemistry, vol.63, pp.104-112, 2014.
DOI : 10.1016/j.trac.2014.08.005

URL : https://hal.archives-ouvertes.fr/hal-01230120

D. R. Stoll, J. Danforth, K. Zhang, and A. Beck, Characterization of therapeutic antibodies and related products by two-dimensional liquid chromatography coupled with UV absorbance and mass spectrometric detection, Journal of Chromatography B, vol.1032, pp.51-60, 2016.
DOI : 10.1016/j.jchromb.2016.05.029

M. Sarrut, A. D-'attoma, and S. Heinisch, Optimization of conditions in on-line comprehensive two-dimensional reversed phase liquid chromatography. Experimental comparison with one-dimensional reversed phase liquid chromatography for the separation of peptides, Journal of Chromatography A, vol.1421, pp.48-59, 2015.
DOI : 10.1016/j.chroma.2015.08.052

URL : https://hal.archives-ouvertes.fr/hal-01242081

F. Bedani, P. J. Schoenmakers, and H. Janssen, Theories to support method development in comprehensive two-dimensional liquid chromatography - A review, Journal of Separation Science, vol.29, issue.14, pp.1697-1711, 2012.
DOI : 10.1002/jssc.201200070

P. J. Schoenmakers, G. Vivó-truyols, and W. M. Decrop, A protocol for designing comprehensive two-dimensional liquid chromatography separation systems, Journal of Chromatography A, vol.1120, issue.1-2, pp.282-290, 2006.
DOI : 10.1016/j.chroma.2005.11.039

H. Poppe, Some reflections on speed and efficiency of modern chromatographic methods, Journal of Chromatography A, vol.778, issue.1-2, pp.3-21, 1997.
DOI : 10.1016/S0021-9673(97)00376-2

K. Horie, H. Kimura, T. Ikegami, A. Iwatsuka, N. Saad et al., Calculating Optimal Modulation Periods to Maximize the Peak Capacity in Two-Dimensional HPLC, Analytical Chemistry, vol.79, issue.10, pp.3764-3770, 2007.
DOI : 10.1021/ac062002t

H. Gu, Y. Huang, and P. W. Carr, Peak capacity optimization in comprehensive two dimensional liquid chromatography: A practical approach, Journal of Chromatography A, vol.1218, issue.1, pp.64-73, 2011.
DOI : 10.1016/j.chroma.2010.10.096

G. Vivoí-truyols, S. Van-der-wal, and P. J. Schoenmakers, Comprehensive Study on the Optimization of Online Two-Dimensional Liquid Chromatographic Systems Considering Losses in Theoretical Peak Capacity in First- and Second-Dimensions: A Pareto-Optimality Approach, Analytical Chemistry, vol.82, issue.20, pp.8525-8536, 2010.
DOI : 10.1021/ac101420f

D. R. Stoll, X. Wang, and P. W. Carr, Comparison of the Practical Resolving Power of One- and Two-Dimensional High-Performance Liquid Chromatography Analysis of Metabolomic Samples, Analytical Chemistry, vol.80, issue.1, pp.268-278, 2008.
DOI : 10.1021/ac701676b

L. W. Potts and P. W. Carr, Analysis of the temporal performance of one versus on-line comprehensive two-dimensional liquid chromatography, Journal of Chromatography A, vol.1310, pp.37-44, 2013.
DOI : 10.1016/j.chroma.2013.07.102

Y. Huang, H. Gu, M. Filgueira, and P. W. Carr, An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography, Journal of Chromatography A, vol.1218, issue.20, pp.2984-2994, 2011.
DOI : 10.1016/j.chroma.2011.03.032

L. W. Potts, D. R. Stoll, X. Li, and P. W. Carr, The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography, Journal of Chromatography A, vol.1217, issue.36, pp.5700-5709, 2010.
DOI : 10.1016/j.chroma.2010.07.009

K. Horie, Y. Sato, T. Kimura, T. Nakamura, Y. Ishihama et al., Estimation and optimization of the peak capacity of one-dimensional gradient high performance liquid chromatography using a long monolithic silica capillary column, Journal of Chromatography A, vol.1228, pp.283-291, 2012.
DOI : 10.1016/j.chroma.2011.12.088

A. D. 'attoma, C. Grivel, and S. Heinisch, On-line comprehensive two-dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part I: orthogonality and practical peak capacity considerations, J. Chromatogr. A, vol.1262, pp.148-159, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00876061

U. D. Neue, Theory of peak capacity in gradient elution, Journal of Chromatography A, vol.1079, issue.1-2, pp.153-161, 2005.
DOI : 10.1016/j.chroma.2005.03.008

L. R. Snyder, J. W. Dolan, and J. R. Gant, Gradient elution in high-performance liquid chromatography, Journal of Chromatography A, vol.165, issue.1, pp.3-30, 1979.
DOI : 10.1016/S0021-9673(00)85726-X

J. P. Foley and J. G. Dorsey, Equations for calculation of chromatographic figures of merit for ideal and skewed peaks, Analytical Chemistry, vol.55, issue.4, pp.730-737, 1983.
DOI : 10.1021/ac00255a033

J. M. Davis, D. R. Stoll, and P. W. Carr, Effect of First-Dimension Undersampling on Effective Peak Capacity in Comprehensive Two-Dimensional Separations, Analytical Chemistry, vol.80, issue.2, pp.461-473, 2008.
DOI : 10.1021/ac071504j

A. Le-masle, D. Angot, C. Gouin, A. D. 'attoma, J. Ponthus et al., Development of on-line comprehensive two-dimensional liquid chromatography method for the separation of biomass compounds, Journal of Chromatography A, vol.1340
DOI : 10.1016/j.chroma.2014.03.020

URL : https://hal.archives-ouvertes.fr/hal-00991030

S. Heinisch, J. Rocca, and M. Feinberg, Optimization of a chromatographic analysis in reversed phase liquid chromatography, Journal of Chemometrics, vol.438, issue.S1, pp.127-137, 1989.
DOI : 10.1002/cem.1180030505

J. C. Giddings, Comparison of Theoretical Limit of Separating Speed in Gas and Liquid Chromatography., Analytical Chemistry, vol.37, issue.1, pp.60-63, 1965.
DOI : 10.1021/ac60220a012

G. Desmet, D. Clicq, and P. , Geometry-Independent Plate Height Representation Methods for the Direct Comparison of the Kinetic Performance of LC Supports with a Different Size or Morphology, Analytical Chemistry, vol.77, issue.13, pp.4058-4070, 2005.
DOI : 10.1021/ac050160z

Y. Zhang, X. Wang, P. Mukherjee, and P. Petersson, Critical comparison of performances of superficially porous particles and sub-2??m particles under optimized ultra-high pressure conditions, Journal of Chromatography A, vol.1216, issue.21, pp.4597-4605, 2009.
DOI : 10.1016/j.chroma.2009.03.071

K. Broeckhoven, D. Cabooter, F. Lynen, P. Sandra, and G. Desmet, The kinetic plot method applied to gradient chromatography: Theoretical framework and experimental validation, Journal of Chromatography A, vol.1217, issue.17, pp.2787-2795, 2010.
DOI : 10.1016/j.chroma.2010.02.023

S. Heinisch and J. Rocca, Sense and nonsense of high-temperature liquid chromatography, Journal of Chromatography A, vol.1216, issue.4, pp.642-658, 2009.
DOI : 10.1016/j.chroma.2008.11.079

F. Gritti and G. Guiochon, Separation of peptides and intact proteins by electrostatic repulsion reversed phase liquid chromatography, Journal of Chromatography A, vol.1374, pp.112-121, 2014.
DOI : 10.1016/j.chroma.2014.11.036

S. Heinisch, Chapter 4. Using Elevated Temperature in UHPLC: Interest and Limitations, UHPLC in Life Sciences, pp.102-130
DOI : 10.1039/9781849735490-00102

S. Heinisch, A. D-'attoma, and C. , Effect of pH additive and column temperature on kinetic performance of two different sub-2?m stationary phases for ultrafast separation of charged analytes, Journal of Chromatography A, vol.1228, pp.135-147, 2012.
DOI : 10.1016/j.chroma.2011.08.041

URL : https://hal.archives-ouvertes.fr/hal-00704052

J. Ruta, D. Zurlino, C. Grivel, S. Heinisch, J. Veuthey et al., Evaluation of columns packed with shell particles with compounds of pharmaceutical interest, Journal of Chromatography A, vol.1228, pp.221-231, 2012.
DOI : 10.1016/j.chroma.2011.09.013

URL : https://hal.archives-ouvertes.fr/hal-00698468

A. D. 'attoma and S. Heinisch, On-line comprehensive two dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part II: application to the separation of peptides, J. Chromatogr. A, vol.1306, pp.27-36, 2013.
URL : https://hal.archives-ouvertes.fr/hal-00876061

R. E. Murphy, M. R. Schure, and J. P. Foley, Effect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography, Analytical Chemistry, vol.70, issue.8, pp.1585-1594, 1998.
DOI : 10.1021/ac971184b

]. A. Beck, T. Wurch, C. Bailly, and N. Corvaia, Strategies and challenges for the next generation of therapeutic antibodies, Nature Reviews Immunology, vol.368, issue.5, pp.345-352, 2010.
DOI : 10.1038/nri2747

L. N. Le, J. M. Moore, J. Ouyang, X. Chen, M. D. Nguyen et al., Profiling Antibody Drug Conjugate Positional Isomers: A System-of-Equations Approach, Analytical Chemistry, vol.84, issue.17, pp.7479-7486, 2012.
DOI : 10.1021/ac301568f

P. D. Senter and E. L. Sievers, The discovery and development of brentuximab vedotin for use in relapsed Hodgkin lymphoma and systemic anaplastic large cell lymphoma, Nature Biotechnology, vol.25, issue.7, pp.631-637, 2012.
DOI : 10.1038/nbt.2289

B. A. Teicher and R. V. Chari, Antibody Conjugate Therapeutics: Challenges and Potential, Clinical Cancer Research, vol.17, issue.20, pp.6389-6397, 2011.
DOI : 10.1158/1078-0432.CCR-11-1417

B. Wiggins, L. Liu-shin, H. Yamaguchi, and G. Ratnaswamy, Characterization of Cysteine-Linked Conjugation Profiles of Immunoglobulin G1 and Immunoglobulin G2 Antibody???Drug Conjugates, Journal of Pharmaceutical Sciences, vol.104, issue.4, pp.1362-1372, 2015.
DOI : 10.1002/jps.24338

M. Haverick, S. Mengisen, M. Shameem, and A. Ambrogelly, Separation of mAbs molecular variants by analytical hydrophobic interaction chromatography HPLC: overview and applications, mAbs, vol.151, issue.4, pp.852-858, 2014.
DOI : 10.1158/1078-0432.CCR-04-0789

J. Ouyang, Drug-to-Antibody Ratio (DAR) and Drug Load Distribution by Hydrophobic Interaction Chromatography and Reversed Phase High-Performance Liquid Chromatography, pp.275-283978
DOI : 10.1007/978-1-62703-541-5_17

J. F. Valliere-douglass, S. M. Hengel, and L. Y. Pan, Approaches to Interchain Cysteine-Linked ADC Characterization by Mass Spectrometry, Molecular Pharmaceutics, vol.12, issue.6, pp.1774-1783, 2015.
DOI : 10.1021/mp500614p

L. Y. Pan, O. Salas-solano, and J. F. Valliere-douglass, Conformation and Dynamics of Interchain Cysteine-Linked Antibody-Drug Conjugates as Revealed by Hydrogen/Deuterium Exchange Mass Spectrometry, Analytical Chemistry, vol.86, issue.5, pp.2657-2664, 2014.
DOI : 10.1021/ac404003q

A. Beck, E. Wagner-rousset, D. Ayoub, A. Van-dorsselaer, and S. Sanglier-cianférani, Characterization of Therapeutic Antibodies and Related Products, Analytical Chemistry, vol.85, issue.2, pp.715-736, 2013.
DOI : 10.1021/ac3032355

A. Wakankar, Y. Chen, Y. Gokarn, and F. S. Jacobson, Analytical methods for physicochemical characterization of antibody drug conjugates, mAbs, vol.35, issue.2, pp.161-172, 2011.
DOI : 10.4161/mabs.2.5.12897

A. Beck and S. Cianferani, Harnessing the benefits of mass spectrometry for in-depth antibody drug conjugates analytical characterization

A. Beck, G. Terral, F. Debaene, J. Wagner-rousset, O. Janin-bussat et al., Cutting-edge mass spectrometry methods for the multi-level structural characterization of antibody-drug conjugates, Expert Review of Proteomics, vol.13, issue.2, 2015.
DOI : 10.1586/14789450.2016.1132167

R. E. Birdsall, S. M. Mccarthy, M. C. Janin-bussat, M. Perez, J. Haeuw et al., A sensitive multidimensional method for the detection, characterization, and quantification of trace free drug species in antibody-drug conjugate samples using mass spectral detection, mAbs, vol.35, issue.2, pp.306-317, 2015.
DOI : 10.4161/mabs.3.2.14960

K. Sandra, G. Vanhoenacker, I. Vandenheede, M. Steenbeke, M. Joseph et al., Multiple heart-cutting and comprehensive two-dimensional liquid chromatography hyphenated to mass spectrometry for the characterization of the antibody-drug conjugate ado-trastuzumab emtansine, Journal of Chromatography B, vol.1032
DOI : 10.1016/j.jchromb.2016.04.040

F. Debaene, A. Boeuf, E. Wagner-rousset, O. Colas, D. Ayoub et al., Innovative Native MS Methodologies for Antibody Drug Conjugate Characterization: High Resolution Native MS and IM-MS for Average DAR and DAR Distribution Assessment, Analytical Chemistry, vol.86, issue.21, pp.10674-10683, 2014.
DOI : 10.1021/ac502593n

M. Janin-bussat, M. Dillenbourg, N. Corvaia, A. Beck, and C. Klinguer-hamour, Characterization of antibody drug conjugate positional isomers at cysteine residues by peptide mapping LC???MS analysis, Journal of Chromatography B, vol.981, issue.982, pp.981-982
DOI : 10.1016/j.jchromb.2014.12.017

R. E. Birdsall, H. Shion, F. W. Kotch, A. Xu, T. J. Porter et al., A rapid on-line method for mass spectrometric confirmation of a cysteine-conjugated antibody-drug-conjugate structure using multidimensional chromatography, mAbs, vol.36, issue.6, pp.1036-1044, 2015.
DOI : 10.4161/mabs.26632

M. Sarrut, A. D-'attoma, and S. Heinisch, Optimization of conditions in on-line comprehensive two-dimensional reversed phase liquid chromatography. Experimental comparison with one-dimensional reversed phase liquid chromatography for the separation of peptides, Journal of Chromatography A, vol.1421, pp.48-59, 2015.
DOI : 10.1016/j.chroma.2015.08.052

URL : https://hal.archives-ouvertes.fr/hal-01242081

J. L. Fausnaugh, L. A. Kennedy, and F. E. Regnier, Comparison of hydrophobic-interaction and reversed-phase chromatography of proteins, Journal of Chromatography A, vol.317, issue.01, pp.317-141, 1984.
DOI : 10.1016/S0021-9673(01)91654-1

A. Cusumano, D. Guillarme, A. Beck, and S. Fekete, Practical method development for the separation of monoclonal antibodies and antibody-drug-conjugate species in hydotphobic interaction chromatography, Part 2: Optimization of the phase sytem, J. Pharm. Biomed. Anal, 2016.

S. Pahlman, J. Rosengren, and S. Hjertén, Hydrophobic interaction chromatography on uncharged sepharose?? derivatives, Journal of Chromatography A, vol.131, issue.00, pp.99-108, 1977.
DOI : 10.1016/S0021-9673(00)80924-3

L. R. Snyder, J. W. Dolan, and J. R. Gant, Gradient elution in high-performance liquid chromatography, Journal of Chromatography A, vol.165, issue.1, pp.3-30, 1979.
DOI : 10.1016/S0021-9673(00)85726-X

M. Sarrut, G. Crétier, and S. Heinisch, Theoretical and practical interest in UHPLC technology for 2D-LC, TrAC Trends in Analytical Chemistry, vol.63, pp.104-112, 2014.
DOI : 10.1016/j.trac.2014.08.005

URL : https://hal.archives-ouvertes.fr/hal-01230120

B. Bobály, A. Beck, J. Fekete, D. Guillarme, and S. Fekete, Systematic evaluation of mobile phase additives for the LC???MS characterization of therapeutic proteins, Talanta, vol.136, pp.60-67, 2015.
DOI : 10.1016/j.talanta.2014.12.006

K. J. Hamblett, P. D. Senter, D. F. Chace, M. M. Sun, J. Lenox et al., Effects of Drug Loading on the Antitumor Activity of a Monoclonal Antibody Drug Conjugate, Clinical Cancer Research, vol.10, issue.20, pp.7063-7070, 2004.
DOI : 10.1158/1078-0432.CCR-04-0789

E. L. Sievers and P. D. Senter, Antibody-Drug Conjugates in Cancer Therapy, Annual Review of Medicine, vol.64, issue.1, pp.15-29, 2013.
DOI : 10.1146/annurev-med-050311-201823

]. B. Wiggins, L. Liu-shin, H. Yamaguchi, and G. Ratnaswamy, Characterization of Cysteine-Linked Conjugation Profiles of Immunoglobulin G1 and Immunoglobulin G2 Antibody???Drug Conjugates, Journal of Pharmaceutical Sciences, vol.104, issue.4, pp.1362-1372, 2015.
DOI : 10.1002/jps.24338

M. Haverick, S. Mengisen, M. Shameem, and A. Ambrogelly, Separation of mAbs molecular variants by analytical hydrophobic interaction chromatography HPLC: overview and applications, mAbs, vol.151, issue.4, pp.852-858, 2014.
DOI : 10.1158/1078-0432.CCR-04-0789

B. Shen, K. Xu, L. Liu, H. Raab, S. Bhakta et al., Conjugation site modulates the in vivo stability and therapeutic activity of antibody-drug conjugates, Nature Biotechnology, vol.179, issue.2, pp.184-189, 2012.
DOI : 10.1158/0008-5472.CAN-06-4512

Y. T. Adem, K. A. Schwarz, E. Duenas, T. W. Patapoff, W. J. Galush et al., Auristatin Antibody Drug Conjugate Physical Instability and the Role of Drug Payload, Bioconjugate Chemistry, vol.25, issue.4, pp.656-664, 2014.
DOI : 10.1021/bc400439x

B. Bender, D. D. Leipold, K. Xu, B. Shen, J. Tibbitts et al., A Mechanistic Pharmacokinetic Model Elucidating the Disposition of Trastuzumab Emtansine (T-DM1), an Antibody???Drug Conjugate (ADC) for Treatment of Metastatic Breast Cancer, The AAPS Journal, vol.16, issue.5, pp.994-1008, 2014.
DOI : 10.1208/s12248-014-9618-3

L. N. Le, J. M. Moore, J. Ouyang, X. Chen, M. D. Nguyen et al., Profiling Antibody Drug Conjugate Positional Isomers: A System-of-Equations Approach, Analytical Chemistry, vol.84, issue.17, pp.7479-7486, 2012.
DOI : 10.1021/ac301568f

A. Wakankar, Y. Chen, Y. Gokarn, and F. S. Jacobson, Analytical methods for physicochemical characterization of antibody drug conjugates, mAbs, vol.35, issue.2, pp.161-172, 2011.
DOI : 10.4161/mabs.2.5.12897

. Janin-bussat, Cutting-edge mass spectrometry methods for the multi-level structural characterization of antibody-drug conjugates, Expert Rev. Proteomics, vol.13, pp.157-183, 2016.

F. Debaene, A. Boeuf, E. Wagner-rousset, O. Colas, D. Ayoub et al., Innovative Native MS Methodologies for Antibody Drug Conjugate Characterization: High Resolution Native MS and IM-MS for Average DAR and DAR Distribution Assessment, Analytical Chemistry, vol.86, issue.21, pp.10674-10683, 2014.
DOI : 10.1021/ac502593n

R. E. Birdsall, H. Shion, F. W. Kotch, A. Xu, T. J. Porter et al., A rapid on-line method for mass spectrometric confirmation of a cysteine-conjugated antibody-drug-conjugate structure using multidimensional chromatography, mAbs, vol.36, issue.6, pp.1036-1044, 2015.
DOI : 10.4161/mabs.26632

M. Sarrut, A. Corgier, S. Fekete, D. Guillarme, D. Lascoux et al., Analysis of antibody-drug conjugates by comprehensive on-line two-dimensional hydrophobic interaction chromatography x reversed phase liquid chromatography hyphenated to high resolution mass spectrometry. I ??? Optimization of separation conditions, Journal of Chromatography B, vol.1032, 2016.
DOI : 10.1016/j.jchromb.2016.06.048

URL : https://hal.archives-ouvertes.fr/hal-01356684

M. Janin-bussat, M. Dillenbourg, N. Corvaia, A. Beck, and C. Klinguer-hamour, Characterization of antibody drug conjugate positional isomers at cysteine residues by peptide mapping LC???MS analysis, Journal of Chromatography B, vol.981, issue.982, pp.981-982, 2015.
DOI : 10.1016/j.jchromb.2014.12.017

A. Beck, E. Wagner-rousset, D. Ayoub, A. Van-dorsselaer, and S. Sanglier-cianférani, Characterization of Therapeutic Antibodies and Related Products, Analytical Chemistry, vol.85, issue.2, pp.715-736, 2013.
DOI : 10.1021/ac3032355

G. Vanhoenacker, I. Vandenheede, F. David, P. Sandra, and K. Sandra, Comprehensive two-dimensional liquid chromatography of therapeutic monoclonal antibody digests, Analytical and Bioanalytical Chemistry, vol.825, issue.1, pp.355-366, 2015.
DOI : 10.1007/s00216-014-8299-1

]. A. Beck, J. M. Reichert, A. Beck, and E. , Antibody-drug conjugates, mAbs

. Cianférani, Characterization of Therapeutic Antibodies and Related Products

J. X. Shen, R. J. Motyka, J. P. Roach, R. N. Hayes, Y. T. Adem et al., Minimization of ion suppression in LCMS/MS analysis through the application of strong cation exchange solid-phase extraction (SCX-SPE) Auristatin Antibody Drug Conjugate Physical Instability and the Role of Drug Payload A Mechanistic Pharmacokinetic Model Elucidating the Disposition of Trastuzumab Emtansine (T-DM1), an AntibodyDrug Conjugate (ADC) for Treatment of Metastatic Breast Cancer, Chromatographic, Electrophoretic, and Mass Spectrometric Methods for the Analytical Characterization of Protein Biopharmaceuticals Therapeutic Antibodies and Related Products by Two-Dimensional Liquid Chromatography Coupled with UV Absorbance and Mass Spectrometric Detection, 2005.

]. P. Dugo, F. Cacciola, T. Kumm, G. Dugo, and L. Mondello, Comprehensive multidimensional liquid chromatography: Theory and applications, Journal of Chromatography A, vol.1184, issue.1-2, pp.353-368, 2008.
DOI : 10.1016/j.chroma.2007.06.074

I. Franç-ois, K. Sandra, and P. Sandra, Comprehensive liquid chromatography: Fundamental aspects and practical considerations???A review, Analytica Chimica Acta, vol.641, issue.1-2, pp.14-31, 2009.
DOI : 10.1016/j.aca.2009.03.041

P. Q. Tranchida, P. Donato, F. Cacciola, M. Beccaria, P. Dugo et al., Potential of comprehensive chromatography in food analysis, TrAC Trends in Analytical Chemistry, vol.52, pp.186-205, 2013.
DOI : 10.1016/j.trac.2013.07.008

M. Sarrut, G. Crétier, and S. Heinisch, Theoretical and practical interest in UHPLC technology for 2D-LC, TrAC Trends in Analytical Chemistry, vol.63, pp.104-112, 2014.
DOI : 10.1016/j.trac.2014.08.005

URL : https://hal.archives-ouvertes.fr/hal-01230120

G. Guiochon, N. Marchetti, K. Mriziq, and R. A. Shalliker, Implementations of two-dimensional liquid chromatography, Journal of Chromatography A, vol.1189, issue.1-2, pp.109-168, 2008.
DOI : 10.1016/j.chroma.2008.01.086

A. D. 'attoma, C. Grivel, and S. Heinisch, On-line comprehensive two-dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part I: Orthogonality and practical peak capacity considerations, J. Chromatogr. A, vol.1262, pp.148-159, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00876061

I. Franç-ois, A. De-villiers, and P. Sandra, Considerations on the possibilities and limitations of comprehensive normal phase???reversed phase liquid chromatography (NPLC??RPLC), Journal of Separation Science, vol.19, issue.4, pp.492-498, 2006.
DOI : 10.1002/jssc.200500451

K. J. Mayfield, R. A. Shalliker, H. J. Catchpoole, A. P. Sweeney, V. Wong et al., Viscous fingering induced flow instability in multidimensional liquid chromatography, Journal of Chromatography A, vol.1080, issue.2, pp.124-131, 2005.
DOI : 10.1016/j.chroma.2005.04.093

P. Jandera, Column selectivity for two-dimensional liquid chromatography, Journal of Separation Science, vol.29, issue.12, pp.1763-1783, 2006.
DOI : 10.1002/jssc.200600202

A. Le-masle, D. Angot, C. Gouin, A. D. 'attoma, J. Ponthus et al., Development of on-line comprehensive two-dimensional liquid chromatography method for the separation of biomass compounds, Journal of Chromatography A, vol.1340, pp.90-98, 2014.
DOI : 10.1016/j.chroma.2014.03.020

URL : https://hal.archives-ouvertes.fr/hal-00991030

D. Tomasini, F. Cacciola, F. Rigano, D. Sciarrone, P. Donato et al., Complementary Analytical Liquid Chromatography Methods for the Characterization of Aqueous Phase from Pyrolysis of Lignocellulosic Biomasses, Analytical Chemistry, vol.86, issue.22, pp.11255-11262, 2014.
DOI : 10.1021/ac5038957

C. West and E. Lesellier, Characterisation of stationary phases in subcritical fluid chromatography by the solvation parameter model, Journal of Chromatography A, vol.1110, issue.1-2, pp.191-199, 2006.
DOI : 10.1016/j.chroma.2006.02.002

A. Grand-guillaume-perrenoud, J. Veuthey, and D. Guillarme, Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the analysis of pharmaceutical compounds, Journal of Chromatography A, vol.1266, pp.158-167, 2012.
DOI : 10.1016/j.chroma.2012.10.005

I. Franç-ois, P. Sandra, P. G. Stevenson, A. Tarafder, and G. Guiochon, Comprehensive supercritical fluid chromatography??reversed phase liquid chromatography for the analysis of the fatty acids in fish oil, Journal of Chromatography A, vol.1216, issue.18, pp.4005-4012, 2009.
DOI : 10.1016/j.chroma.2009.02.078

J. M. Davis, D. R. Stoll, and P. W. Carr, Effect of First-Dimension Undersampling on Effective Peak Capacity in Comprehensive Two-Dimensional Separations, Analytical Chemistry, vol.80, issue.2, pp.461-473, 2008.
DOI : 10.1021/ac071504j

V. Abrahamsson and M. Sandahl, Impact of injection solvents on supercritical fluid chromatography, Journal of Chromatography A, vol.1306, pp.80-88, 2013.
DOI : 10.1016/j.chroma.2013.07.056

J. N. Fairchild, J. F. Hill, and P. Iraneta, Influence of sample solvent composition for SFC separations, LC-GC N. Am, pp.31-326, 2013.

S. Khater, C. West, and E. Lesellier, Characterization of five chemistries and three particle sizes of stationary phases used in supercritical fluid chromatography, Journal of Chromatography A, vol.1319, pp.148-159, 2013.
DOI : 10.1016/j.chroma.2013.10.037

L. Nováková, A. Grand-guillaume-perrenoud, R. Nicoli, M. Saugy, J. Veuthey et al., Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. I: Investigation of mobile phase and MS conditions, Analytica Chimica Acta, vol.853, pp.637-646, 2015.
DOI : 10.1016/j.aca.2014.10.004

A. Grand-guillaume-perrenoud, C. Hamman, M. Goel, J. Veuthey, D. Guillarme et al., Maximizing kinetic performance in supercritical fluid chromatography using state-of-the-art instruments, Journal of Chromatography A, vol.1314, pp.288-297, 2013.
DOI : 10.1016/j.chroma.2013.09.039

A. P. Schellinger, D. R. Stoll, and P. W. Carr, High-speed gradient elution reversed-phase liquid chromatography of bases in buffered eluents, Journal of Chromatography A, vol.1192, issue.1, pp.41-53, 2008.
DOI : 10.1016/j.chroma.2008.01.062

A. P. Schellinger, D. R. Stoll, and P. W. Carr, High speed gradient elution reversed phase liquid chromatography of bases in buffered eluents, Journal of Chromatography A, vol.1192, issue.1, pp.54-61, 2008.
DOI : 10.1016/j.chroma.2008.02.049

C. Grivel, J. Rocca, D. Guillarme, J. Veuthey, and S. Heinisch, Selection of suitable operating conditions to minimize the gradient equilibration time in the separation of drugs by Ultra-High-Pressure Liquid Chromatography with volatile (mass spectrometry-compatible) buffers, Journal of Chromatography A, vol.1217, issue.4, pp.459-472, 2010.
DOI : 10.1016/j.chroma.2009.11.059

T. A. Berger and B. K. Berger, Minimizing UV noise in supercritical fluid chromatography. I. Improving back pressure regulator pressure noise, Journal of Chromatography A, vol.1218, issue.16, pp.2320-2326, 2011.
DOI : 10.1016/j.chroma.2011.02.030