An Embedded Deep Brain Stimulator for Biphasic Chronic Experiments in Freely Moving Rodents, IEEE Transactions on Biomedical Circuits and Systems. International conferences, 2014. ,
DOI : 10.1109/TBCAS.2014.2368788
URL : https://hal.archives-ouvertes.fr/hal-01347597
A closed-loop charge balancing fpaa cicuit with sub-nano-amp dc error for electrical stimulation, Biomedical Circuits and Systems Conference (BioCAS), pp.2014-2014, 2014. ,
Characterization of a non linear fractional model of electrode-tissue impedance for neuronal stimulation, 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS), pp.2013-338, 2013. ,
DOI : 10.1109/BioCAS.2013.6679708
URL : https://hal.archives-ouvertes.fr/hal-00986311
In vivo electrical characterization of deep brain electrode and impact on bio-amplifier design, 2010 Biomedical Circuits and Systems Conference (BioCAS), pp.2010-210, 2010. ,
DOI : 10.1109/BIOCAS.2010.5709608
URL : https://hal.archives-ouvertes.fr/hal-00585051
A programmable bioamplifier on FPAA for in vivo neural recording, 2010 Biomedical Circuits and Systems Conference (BioCAS), pp.2010-114, 2010. ,
DOI : 10.1109/BIOCAS.2010.5709584
URL : https://hal.archives-ouvertes.fr/hal-00585043
Circuit de stimulation nerveuse à contre-réaction d'équilibrage des charges sur fpaa, 2014. ,
CMOS DAC-sharing stimulator for neural recording and stimulation arrays, 2011 IEEE International Symposium of Circuits and Systems (ISCAS), pp.1712-1715, 2011. ,
DOI : 10.1109/ISCAS.2011.5937912
Real-time biomimetic Central Pattern Generators in an FPGA for hybrid experiments, Frontiers in Neuroscience, vol.7, issue.215, 2013. ,
DOI : 10.3389/fnins.2013.00215
URL : https://hal.archives-ouvertes.fr/hal-00956624
Electronic design of a multichannel programmable implant for neuromuscular electrical stimulation, IEEE Transactions on Rehabilitation Engineering, vol.7, issue.2, p.11, 1999. ,
DOI : 10.1109/86.769411
Wireless Neural Stimulation in Freely Behaving Small Animals, Journal of Neurophysiology, vol.102, issue.1, p.8, 2009. ,
DOI : 10.1152/jn.00017.2009
An Energy-Efficient, Adiabatic Electrode Stimlulator With Inductive Energy Recycling and Feedback Current Regulation, IEEE Transactions on Biomedical Circuits and Systems, vol.6, issue.1, p.14, 2012. ,
A Battery-Powered Activity-Dependent Intracortical Microstimulation IC for Brain-Machine-Brain Interface, IEEE Journal of Solid-State Circuits, vol.46, issue.4, 2011. ,
DOI : 10.1109/JSSC.2011.2108770
Hemiparkinsonism in monkeys after unilateral internal carotid artery infusion of 1-methyl-4, Life Sci, vol.39, issue.1, pp.6-7, 1986. ,
Electrochemical Methods: Fundamentals and Applications, 2001. ,
RASP 2.8: A new generation of floating-gate based field programmable analog array, 2008 IEEE Custom Integrated Circuits Conference, pp.213-216, 2008. ,
DOI : 10.1109/CICC.2008.4672061
Assessment of human diaphragm strength and activation using phrenic nerve stimulation, Respiration Physiology, vol.58, issue.3, pp.263-277, 1984. ,
DOI : 10.1016/0034-5687(84)90003-3
Noradrenergic Modulation of Subthalamic Nucleus Activity: Behavioral and Electrophysiological Evidence in Intact and 6-Hydroxydopamine-Lesioned Rats, Journal of Neuroscience, vol.27, issue.36, pp.279595-9606, 2007. ,
DOI : 10.1523/JNEUROSCI.2583-07.2007
Deep brain stimulation for Parkinson???s disease, Current Opinion in Neurobiology, vol.13, issue.6, pp.696-706, 2003. ,
DOI : 10.1016/j.conb.2003.11.001
Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus. The Lancet, pp.337403-406, 1991. ,
Reversal of experimental parkinsonism by lesions of the subthalamic nucleus, Science, vol.249, issue.4975, pp.2491436-1438, 1990. ,
DOI : 10.1126/science.2402638
Untersuchungen zur Thermodynamik der bioelektrischen Str??me, Pfl??ger Archiv f??r die Gesammte Physiologie des Menschen und der Thiere, vol.92, issue.10-12, pp.521-562, 1902. ,
DOI : 10.1007/BF01790181
A bidirectional neural interface with a HV stimulator and a LV neural amplifier, 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013), p.4, 2013. ,
DOI : 10.1109/ISCAS.2013.6571865
Vagus nerve stimulation for epilepsy: a review, Seizure, vol.9, issue.3, pp.161-169, 2000. ,
DOI : 10.1053/seiz.1999.0354
An Integrated System for simultaneous, Multichannel Neuronal Stimluation and Recording. IEEE Transactions on circuits and systems -I: Regular papers, p.5411, 2007. ,
Batteries used to power implantable biomedical devices, Electrochimica Acta, vol.84, pp.155-164, 2012. ,
DOI : 10.1016/j.electacta.2012.03.057
A real-time system for multisite stimulation on living neural networks, 2009 Joint IEEE North-East Workshop on Circuits and Systems and TAISA Conference, p.4, 2009. ,
DOI : 10.1109/NEWCAS.2009.5290451
Personalized Neuroprosthetics, Science Translational Medicine, vol.5, issue.210, pp.210-212, 2013. ,
DOI : 10.1126/scitranslmed.3005968
Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs, IEEE Transactions on Rehabilitation Engineering, vol.8, issue.4, p.7, 2000. ,
DOI : 10.1109/86.895949
The sensations produced by electrical stimulation of the visual cortex, The Journal of Physiology, vol.196, issue.2, pp.479-493, 1968. ,
DOI : 10.1113/jphysiol.1968.sp008519
Adaptive Floating-Gate Circuit Enabled Large-Scale FPAA, IEEE Transactions on Very Large Scale Integration (VLSI) Systems, vol.22, issue.11, pp.1-1, 2014. ,
DOI : 10.1109/TVLSI.2013.2290305
Stimulus-Artifact Elimination in a Multi-Electrode System, IEEE Transactions on Biomedical Circuits and Systems, vol.2, issue.1, pp.10-21, 2008. ,
DOI : 10.1109/TBCAS.2008.918285
Ethological and temporal analyses of anxiety-like behavior: The elevated plus-maze model 20 years on, Neuroscience & Biobehavioral Reviews, vol.29, issue.8, pp.291193-205, 2005. ,
DOI : 10.1016/j.neubiorev.2005.04.017
A novel system design for implantable stimulator application, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2004. ,
DOI : 10.1109/IEMBS.2004.1404146
System Design of Implantable Microstimulator for Medical Treatments, APCCAS 2006 -2006 IEEE Asia Pacific Conf. Circuits Syst, pp.478-481, 2006. ,
Current steering to activate targeted neural pathways during deep brain stimulation of the subthalamic region, Brain Stimulation, vol.5, issue.3, pp.369-377, 2012. ,
DOI : 10.1016/j.brs.2011.05.002
An Integrated 256-Channel Epiretinal Prosthesis, IEEE Journal of Solid-State Circuits, vol.45, issue.9, p.4511, 2010. ,
DOI : 10.1109/JSSC.2010.2055371
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa, Archives of Ophthalmology, vol.122, issue.4, pp.460-469, 2004. ,
DOI : 10.1001/archopht.122.4.460
A Flexible Biphasic Pulse Generating and Accurate Charge Balancing Stimluator with a 1 microW Neural Recording Amplifier, Circuits and Systems (ISCAS), 2013 IEEE International Symposium on, p.4, 2013. ,
Implantable stimulator for bipolar stimulation without charge balancing circuits, 2010 Biomedical Circuits and Systems Conference (BioCAS), pp.202-205, 2010. ,
DOI : 10.1109/BIOCAS.2010.5709606
TIMELINE: Exorcizing the animal spirits: Jan Swammerdam on nerve function, Nature Reviews Neuroscience, vol.9, issue.5, pp.395-400, 2002. ,
DOI : 10.1080/00033790110050759
Neural Stimulation and Recording Electrodes, Annual Review of Biomedical Engineering, vol.10, issue.1, pp.275-309, 2008. ,
DOI : 10.1146/annurev.bioeng.10.061807.160518
Deep brain stimulation for movement disorders, Neurobiology of Disease, vol.38, issue.3, pp.338-345, 2010. ,
DOI : 10.1016/j.nbd.2009.11.019
A partial-current-steering biphasic stimulation driver for neural prostheses, 2008 IEEE International Symposium on Circuits and Systems, pp.2506-2509, 2008. ,
DOI : 10.1109/ISCAS.2008.4541965
Challenges in recording and stimulation of living neural network based on original micro-electrode array (MEA) developments, 2013 IEEE 11th International New Circuits and Systems Conference (NEWCAS), pp.1-4, 2013. ,
DOI : 10.1109/NEWCAS.2013.6573645
URL : https://hal.archives-ouvertes.fr/hal-00980781
A Highly Flexible System for Microstimluation of the Visual Cortex: Design and Implementation, IEEE Transactions on Biomedical Circuits and Systems, vol.1, issue.4, p.12, 2007. ,
Transformation of nonfunctional spinal circuits into functional states after the loss of brain input, Nature Neuroscience, vol.128, issue.10, pp.121333-1342, 2009. ,
DOI : 10.1038/nn.2401
Membrane action potentials from the squid giant axon, Journal of Cellular and Comparative Physiology, vol.4, issue.2, pp.147-157, 1940. ,
DOI : 10.1002/jcp.1030150204
A Stimulator ASIC Featuring Versatile Management for Vestibular Prostheses, IEEE Transactions on Biomedical Circuits and Systems, vol.5, issue.2, pp.147-59, 2011. ,
DOI : 10.1109/TBCAS.2011.2138139
Emerging dysfunctions consequent to combined monoaminergic depletions in parkinsonism, Neurobiology of Disease, vol.45, issue.2, pp.763-773, 2012. ,
DOI : 10.1016/j.nbd.2011.10.023
URL : https://hal.archives-ouvertes.fr/hal-01178540
Direct Neural Sensory Feedback and Control of a Prosthetic Arm, IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol.13, issue.4, pp.468-472, 2005. ,
DOI : 10.1109/TNSRE.2005.856072
Restoration of respiratory muscle function following spinal cord injury, Respiratory Physiology & Neurobiology, vol.147, issue.2-3, pp.273-287, 2005. ,
DOI : 10.1016/j.resp.2005.03.007
Phrenic nerve pacing in a tetraplegic patient via intramuscular diaphragm electrodes American journal of respiratory and critical care medicine, pp.1661604-1606, 2002. ,
Evidence for a Spinal Central Pattern Generator in Humansa, Annals of the New York Academy of Sciences, vol.7, issue.1 NEURONAL MECH, pp.360-376, 1998. ,
DOI : 10.1016/S0166-2236(96)10068-0
[auditory prosthesis by means of a distant electrical stimulation of the sensory nerve with the use of an indwelt coiling, pp.651417-1417, 1957. ,
A CMOS retinal neurostimulator capable of focussed, simultaneous stimulation, Journal of Neural Engineering, vol.6, issue.3, p.10, 2009. ,
DOI : 10.1088/1741-2560/6/3/035006
Modeling Hot-Electron Injection in pFET's, Journal of Computational Electronics, vol.2, issue.2-4, pp.317-322, 2003. ,
DOI : 10.1023/B:JCEL.0000011445.99473.5f
Dopamine D4 receptor-knock-out mice exhibit reduced exploration of novel stimuli, J. Neurosci, vol.19, issue.21, pp.9550-9556, 1999. ,
Multi-application electrical stimulator architecture dedicated to waveform control by electrode-tissue impedance spectra monitoring, 2012 19th IEEE International Conference on Electronics, Circuits, and Systems (ICECS 2012), p.4, 2012. ,
DOI : 10.1109/ICECS.2012.6463563
Towards a reconfigurable sense-and-stimulate neural interface generating biphasic interleaved stimulus, 2007 3rd International IEEE/EMBS Conference on Neural Engineering, p.4, 2007. ,
DOI : 10.1109/CNE.2007.369703
Implantation of anterior sacral root stimulators combined with posterior sacral rhizotomy in spinal injury patients, World Journal of Urology, vol.16, issue.5, pp.342-349, 1998. ,
DOI : 10.1007/s003450050078
Distribution of noradrenaline and dopamine (3-hydroxytyramine) in the human brain and their behavior in diseases of the extrapyramidal system, Parkinsonism & Related Disorders, vol.4, issue.2, pp.53-57, 1998. ,
DOI : 10.1016/S1353-8020(98)00012-1
Artificial pacemaker for treatment of Adams-Stokes syndrome and slow heart rate, American Heart Journal, vol.65, issue.6, pp.65731-748, 1963. ,
DOI : 10.1016/0002-8703(63)90239-4
SaBer DBS: A fully programmable, rechargeable, bilateral, charge-balanced preclinical microstimulator for long-term neural stimulation, Journal of Neuroscience Methods, vol.213, issue.2, p.8, 2013. ,
DOI : 10.1016/j.jneumeth.2012.12.008
Novel Charge-Metering Stimulus Amplifier for Biomimetic Implantable Prosthesis, 2007 IEEE International Symposium on Circuits and Systems, pp.569-572, 2007. ,
DOI : 10.1109/ISCAS.2007.378801
Wearable, Battery- Powered, Wireless, Programmable 8-Channel Neural Stimulator. 34th Annual International Conference of the IEEE EMBS, p.4, 2012. ,
The Nernst Equation, Journal of Chemical Education, vol.71, issue.6, p.71493, 1994. ,
DOI : 10.1021/ed071p493
A Customizable Multi-channel Stimulator for Cortical Neuroprosthesis, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2007. ,
DOI : 10.1109/IEMBS.2007.4353390
Technology and design of integrated circuits for up to 50 V applications, IEEE International Conference on Industrial Technology, 2003, pp.7-13, 2003. ,
DOI : 10.1109/ICIT.2003.1290223
Impedance Characterization and Modeling of Electrodes for Biomedical Applications, IEEE Transactions on Biomedical Engineering, vol.52, issue.7, pp.521295-1302, 2005. ,
DOI : 10.1109/TBME.2005.847523
De Viribus Electricitatis In Motu Musculari Comentarius Cum Joannis Aldini Dissertatione Et Notis; Accesserunt Epistolae ad animalis electricitatis theoriam pertinentes, 1792. ,
A 126-µW Cochlear Chip for a Totally Implantable System, IEEE Journal of Solid-State Circuits, vol.40, issue.2, p.14, 2005. ,
Spinal cord injury: Present and future therapeutic devices and prostheses, Neurotherapeutics, vol.30, issue.1, pp.147-162, 2008. ,
DOI : 10.1016/j.nurt.2007.10.062
An Efficient Micro-Stimulator Array Using Unitary-Size DAC With Adiabatic Baseband Scheme, 2006 13th IEEE International Conference on Electronics, Circuits and Systems, pp.29-32, 2006. ,
DOI : 10.1109/ICECS.2006.379673
Vestibulo-ocular responses evoked via bilateral electrical stimulation of the lateral semicircular canals, Biomedical Engineering IEEE Transactions on, issue.11, pp.552608-2619, 2008. ,
A CMOS neurostimulator with on-chip DAC calibration and charge balancing, 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS), pp.2013-89, 2013. ,
DOI : 10.1109/BioCAS.2013.6679646
An implantable mixed analog/digital neural stimulator circuit, ISCAS'99. Proceedings of the 1999 IEEE International Symposium on Circuits and Systems VLSI (Cat. No.99CH36349), p.4, 1999. ,
DOI : 10.1109/ISCAS.1999.777587
Field programmable analog arrays: past, present and future perspectives, 1995 IEEE TENCON. IEEE Region 10 International Conference on Microelectronics and VLSI. 'Asia-Pacific Microelectronics 2000'. Proceedings, pp.123-126, 1995. ,
DOI : 10.1109/TENCON.1995.496352
The evolution of pacemakers, IEEE Engineering in Medicine and Biology Magazine, vol.25, issue.3, pp.38-48, 2006. ,
DOI : 10.1109/MEMB.2006.1636350
Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches, Pfl??gers Archiv - European Journal of Physiology, vol.12, issue.2, pp.85-100, 1981. ,
DOI : 10.1007/BF00656997
Latest view on the mechanism of action of deep brain stimulation, Movement Disorders, vol.27, issue.Part 1, pp.2111-2132, 2008. ,
DOI : 10.1002/mds.22120
URL : https://hal.archives-ouvertes.fr/inserm-00483505
Health and Fitness Benefits of Functional Electrical Stimulation-Evoked Leg Exercise for Spinal Cord???Injured Individuals, Topics in Spinal Cord Injury Rehabilitation, vol.14, issue.4, pp.88-121, 2009. ,
DOI : 10.1310/sci1404-88
A 0.45 v 100-channel neuralrecording ic with sub-micro-w /channel consumption in 0.18 micro-m cmos, Biomedical Circuits and Systems IEEE Transactions on, vol.7, issue.6, pp.735-746, 2013. ,
URL : https://hal.archives-ouvertes.fr/in2p3-01292928
Continuous high-frequency stimulation in freely moving rats: Development of an implantable microstimulation system, Journal of Neuroscience Methods, vol.167, issue.2, pp.278-291, 2008. ,
DOI : 10.1016/j.jneumeth.2007.08.019
A low-power low-noise cmos amplifier for neural recording applications. Solid-State Circuits, IEEE Journal, vol.38, issue.6, pp.958-965, 2003. ,
Floating-gate devices, circuits, and systems, invited, System-on-Chip for Real-Time Applications, International Workshop on, pp.482-487, 2005. ,
DOI : 10.1109/iwsoc.2005.65
New considerations in the medical management of early Parkinson's disease: Impact of recent clinical trials on treatment strategy, Parkinsonism & Related Disorders, vol.15, pp.17-21, 2009. ,
DOI : 10.1016/S1353-8020(09)70772-2
Dopaminergic neurotoxicity of 1-methyl-4-phenyl-1,2,5,6-tetrahydropyridine in mice, Science, vol.224, issue.4656, pp.2241451-1453, 1984. ,
DOI : 10.1126/science.6610213
Note sur la vitesse de propagation de l'agent nerveux dans les nerfs rachidiens, CR Acad Sci, vol.30, pp.204-206, 1850. ,
A Microcontroller Embedded ASIC for an Implantable Electro-Neural Stimulator, Proceedings of the 27th European Solid-State Circuits Conference, p.4, 2001. ,
A quantitative description of membrane current and its application to conduction and excitation in nerve, The Journal of Physiology, vol.117, issue.4, p.500, 1952. ,
DOI : 10.1113/jphysiol.1952.sp004764
Chronaxie calculated from current???duration and voltage???duration data, Journal of Neuroscience Methods, vol.97, issue.1, pp.45-50, 2000. ,
DOI : 10.1016/S0165-0270(00)00163-1
A general adaptive charge-balancing stimulator, 2008 51st Midwest Symposium on Circuits and Systems, p.4, 2008. ,
DOI : 10.1109/MWSCAS.2008.4616890
Hindlimb stepping movements in complete spinal rats induced by epidural spinal cord stimulation, Neuroscience Letters, vol.383, issue.3, pp.339-344, 2005. ,
DOI : 10.1016/j.neulet.2005.04.049
Neural interfaces for the brain and spinal cord???restoring motor function, Nature Reviews Neurology, vol.23, issue.12, pp.690-699, 2012. ,
DOI : 10.1109/TNSRE.2010.2076364
Systematic review of sacral nerve stimulation for faecal incontinence and constipation, British Journal of Surgery, vol.90, issue.12, pp.911559-1569, 2004. ,
DOI : 10.1002/bjs.4796
Design of a stimulator ASIC for an implantable vestibular neural prosthesis, 2010 Biomedical Circuits and Systems Conference (BioCAS), pp.2010-206, 2010. ,
DOI : 10.1109/BIOCAS.2010.5709607
An implantable 3-D vestibular stimulator with neural recording, 2012 Proceedings of the ESSCIRC (ESSCIRC), p.4, 2012. ,
DOI : 10.1109/ESSCIRC.2012.6341339
Identification of non-linear system structure and parameters using regime decomposition, Automatica, vol.31, issue.2, pp.31321-326, 1995. ,
DOI : 10.1016/0005-1098(94)00096-2
Multifunctional chronic 3D electrode arrays based on a simple folding process, 2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII), pp.1476-1479, 2013. ,
DOI : 10.1109/Transducers.2013.6627059
Generation of locomotor-like activity in the isolated rat spinal cord by electrical microstimulations driven by an artificial CPG, 2013 IEEE Neural Eng. Short Pap. No. 0079, p.5218, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-00966014
Focalizing electrical neural stimulation with penetrating microelectrode arrays: A modeling study, Journal of Neuroscience Methods, vol.209, issue.1, pp.250-254, 2012. ,
DOI : 10.1016/j.jneumeth.2012.05.006
Modeling extracellular electrical neural stimulation: From basic understanding to MEA-based applications, Journal of Physiology-Paris, vol.106, issue.3-4, pp.146-158, 2012. ,
DOI : 10.1016/j.jphysparis.2011.10.003
A power-efficient neural tissue stimulator with energy recovery. Biomedical Circuits and Systems, IEEE Transactions on, vol.5, issue.1, pp.20-29, 2011. ,
Impedance of rough capacitive electrodes: the role of surface disorder, Journal of Electroanalytical Chemistry, vol.448, issue.1, pp.139-142, 1998. ,
DOI : 10.1016/S0022-0728(98)00025-4
A figure-of-merit for designing high-performance inductive power transmission links. Industrial Electronics, IEEE Transactions on, issue.11, pp.605292-5305, 2013. ,
Distribution of networks generating and coordinating locomotor activity in the neonatal rat spinal cord in vitro: a lesion study, The Journal of neuroscience, issue.18, pp.165777-5794, 1996. ,
Subthalamic nucleus deep brain stimulation: Summary and meta-analysis of outcomes, Movement Disorders, vol.70, issue.S14, pp.290-304, 2006. ,
DOI : 10.1002/mds.20962
Evolution of a CMOS Based Lateral High Voltage Technology Concept, Microelectronics Journal, vol.37, issue.3, pp.243-248, 2006. ,
DOI : 10.1016/j.mejo.2005.09.014
Characterization of a non linear fractional model of electrode-tissue impedance for neuronal stimulation, 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS), pp.338-341, 2013. ,
DOI : 10.1109/BioCAS.2013.6679708
URL : https://hal.archives-ouvertes.fr/hal-00986311
Introduction to the theory, design, and modeling of thin-film microelectrodes for neural interfaces, 1994. ,
High-Power Integrated Stimulator Output Stages With Floating Discharge Over a Wide Voltage Range for Nerve Stimulation, IEEE Transactions on Biomedical Circuits and Systems, vol.4, issue.1, pp.39-48, 2010. ,
DOI : 10.1109/TBCAS.2009.2034138
Biomedical applications of batteries, Solid State Ionics, vol.172, issue.1-4, pp.7-11, 2004. ,
DOI : 10.1016/j.ssi.2004.04.024
A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation, IEEE Journal of Solid-State Circuits, vol.48, issue.9, p.4814, 2013. ,
DOI : 10.1109/JSSC.2013.2266862
A 64 Channel Programmable Closedloop Deep Brain Stimulator with 8 Channel Neural Amplifier and Logarithmic ADC, Symposium on VLSI Circuits Digest of Technical Papers, p.2, 2008. ,
A 64 Channel Programmable Closed-Loop Neurostimulator With 8 Channel Neural Amplifier and Logarithmic ADC, IEEE Journal of Solid-State Circuits, vol.45, issue.9, pp.451935-1945, 2010. ,
DOI : 10.1109/JSSC.2010.2052403
impedance spectroscopy of deep brain stimulation electrodes, Journal of Neural Engineering, vol.6, issue.4, p.46001, 2009. ,
DOI : 10.1088/1741-2560/6/4/046001
impedance spectroscopy of deep brain stimulation electrodes, Journal of Neural Engineering, vol.6, issue.4, p.46001, 2009. ,
DOI : 10.1088/1741-2560/6/4/046001
Effect on parkinsonian signs and symptoms of bilateral subthalamic nucleus stimulation. The Lancet, pp.34591-95, 1995. ,
Effect on parkinsonian signs and symptoms of bilateral subthalamic nucleus stimulation, The Lancet, vol.345, issue.8942, pp.34591-34596, 1995. ,
DOI : 10.1016/S0140-6736(95)90062-4
Physiology of Spinal Cord Stimulation: Review and Update, Neuromodulation: Technology at the Neural Interface, pp.150-164, 1999. ,
DOI : 10.1016/0140-6736(90)93307-B
A neuro-stimulus chip with telemetry unit for retinal prosthetic device, IEEE Journal of Solid-State Circuits, vol.35, issue.10, p.3511, 2000. ,
DOI : 10.1109/4.871327
A Stimulator Output Stage with Capacitor Reduction and Failure-Checking Techniques, IEEE ISCAS, p.4, 2006. ,
Five valuable functions of blocking capacitors in stimulators, 13th Annu. Int. Conf. FES Soc, pp.322-324, 2008. ,
An Integrated Stimulator With DC-Isolation and Fine Current Control for Implanted Nerve Tripoles, IEEE Journal of Solid-State Circuits, vol.46, issue.7, p.4614, 2011. ,
DOI : 10.1109/JSSC.2011.2144310
Active Books: The Design of an Implantable Stimulator That Minimizes Cable Count Using Integrated Circuits Very Close to Electrodes, IEEE Transactions on Biomedical Circuits and Systems, vol.6, issue.3, p.12, 2012. ,
DOI : 10.1109/TBCAS.2011.2174360
Phrenic motor unit recruitment during ventilatory and non-ventilatory behaviors, Respiratory Physiology & Neurobiology, vol.179, issue.1, pp.57-63, 2011. ,
DOI : 10.1016/j.resp.2011.06.028
URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3183333
Retinal Prosthesis for the Blind, Survey of Ophthalmology, vol.47, issue.4, pp.335-356, 2002. ,
DOI : 10.1016/S0039-6257(02)00311-9
A novel apparatus that permits multiple routes for infusions and body-fluid collections in a freely-moving animal, Journal of Neuroscience Methods, vol.57, issue.2, pp.145-154, 1995. ,
DOI : 10.1016/0165-0270(94)00107-R
Deuxième mémoire sur le courant électrique propre de la grénouille et sur celui des animaux à sang chaud, 1842. ,
A Dynamical Theory of the Electromagnetic Field., Proceedings of the Royal Society of London, vol.13, issue.0, pp.531-536, 1863. ,
DOI : 10.1098/rspl.1863.0098
Deep brain stimulation for treatment-resistant depression, Neuron, issue.5, pp.45651-660, 2005. ,
Tissue impedance: a historical overview, Physiological Measurement, vol.16, issue.3A, p.1, 1995. ,
DOI : 10.1088/0967-3334/16/3A/001
The linear and non-linear electrical properties of the electrode-electrolyte interface, Biosensors and Bioelectronics, vol.10, issue.1-2, pp.67-74, 1995. ,
DOI : 10.1016/0956-5663(95)96795-Z
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation, IEEE Transactions on Biomedical Engineering, vol.37, issue.10, pp.37996-1001, 1990. ,
DOI : 10.1109/10.102812
Analysis of a Model for Excitation of Myelinated Nerve, IEEE Transactions on Biomedical Engineering, vol.23, issue.4, pp.329-337, 1976. ,
DOI : 10.1109/TBME.1976.324593
Deep brain stimulation for Parkinson's disease: Potential risk of tissue damage associated with external stimulation, Annals of Neurology, vol.21, issue.3, pp.449-450, 2004. ,
DOI : 10.1002/ana.20002
Electrical stimulation of excitable tissue: design of efficacious and safe protocols, Journal of Neuroscience Methods, vol.141, issue.2, pp.171-198, 2005. ,
DOI : 10.1016/j.jneumeth.2004.10.020
Electrical stimulation of excitable tissue: design of efficacious and safe protocols, Journal of Neuroscience Methods, vol.141, issue.2, pp.141171-98, 2005. ,
DOI : 10.1016/j.jneumeth.2004.10.020
A flexible high voltage biphasic current-controlled stimulator, 2006 IEEE Biomedical Circuits and Systems Conference, p.4, 2006. ,
DOI : 10.1109/BIOCAS.2006.4600344
A novel bioelectronic glucose sensor to process distinct electrical activities of pancreatic beta-cells, EMBC), 2013 35th Annual International Conference of the IEEE, pp.172-175, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-00980774
Restoration of upper limb movement via artificial corticospinal and musculospinal connections in a monkey with spinal cord injury, Frontiers in neural circuits, 2013. ,
DOI : 10.3389/fncir.2013.00057
Safety of multi-channel stimulation implants: a single blocking capacitor per channel is not sufficient after single-fault failure, Medical & Biological Engineering & Computing, vol.119, issue.6, pp.403-410, 2012. ,
DOI : 10.1007/s11517-012-0889-5
A Neural Stimulator Frontend With High-Voltage Compliance and Programmable Pulse Shape for Epiretinal Implants, IEEE Journal of Solid-State Circuits, vol.47, issue.1, pp.244-256, 2012. ,
DOI : 10.1109/JSSC.2011.2164667
Microfabricated electrode arrays for restoring lost sensory and motor functions, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664), pp.959-962, 2003. ,
DOI : 10.1109/SENSOR.2003.1216926
Optimizing a Rodent Model of Parkinson's Disease for Exploring the Effects and Mechanisms of Deep Brain Stimulation, Parkinson's Disease, vol.39, issue.5, p.414682, 2011. ,
DOI : 10.1038/nrn2653
Complete worldwide operative experience in laparoscopic diaphragm pacing: results and differences in spinal cord injured patients and amyotrophic lateral sclerosis patients, Surgical Endoscopy, vol.21, issue.S, pp.1433-1440, 2009. ,
DOI : 10.1007/s00464-008-0223-3
A 232-Channel Epiretinal Stimulator ASIC, IEEE Journal of Solid-State Circuits, vol.42, issue.12, p.4214, 2007. ,
DOI : 10.1109/JSSC.2007.908693
Frequency-band complex noninteger differentiator: characterization and synthesis. Circuits and Systems I: Fundamental Theory and Applications, IEEE Transactions on, vol.47, issue.1, pp.25-39, 2000. ,
DOI : 10.1109/81.817385
Ueber die Potentialdifferenz zwischen zwei verd??nnten L??sungen bin??rer Electrolyte, Annalen der Physik und Chemie, vol.39, issue.8, pp.561-576, 1890. ,
DOI : 10.1002/andp.18902760802
Bioelectricity A quantitative approach, 2007. ,
Fractional differential equations: an introduction to fractional derivatives, fractional differential equations, to methods of their solution and some of their applications, 1998. ,
Study on DBS device for small animals, Conf. Proc. IEEE Eng. Med. Biol. Soc, pp.6773-6779, 2011. ,
Kinetics of rapid electrode reactions, Discussions of the Faraday Society, vol.1, pp.11-19, 1947. ,
DOI : 10.1039/df9470100011
Analysis of Models for External Stimulation of Axons, IEEE Transactions on Biomedical Engineering, vol.33, issue.10, pp.974-977, 1986. ,
DOI : 10.1109/TBME.1986.325670
Analysis of models for extracellular fiber stimulation, IEEE Transactions on Biomedical Engineering, vol.36, issue.7, pp.676-682, 1989. ,
DOI : 10.1109/10.32099
Body weight gain and deep brain stimulation, Journal of the Neurological Sciences, vol.310, issue.1-2, pp.267-70, 2011. ,
DOI : 10.1016/j.jns.2011.06.055
Implantable stimulator featuring multiple programs, adjustable stimulation amplitude and bi-directional communication for implantation in mice, Med. Biol. Eng. Comput, issue.7, pp.45695-45704, 2007. ,
Non-rectangular waveforms for neural stimulation with practical electrodes, Journal of Neural Engineering, vol.4, issue.3, p.227, 2007. ,
DOI : 10.1088/1741-2560/4/3/008
Linear and non-linear behavior of fractal and irregular electrodes, Solid State Ionics, vol.75, pp.269-273, 1995. ,
DOI : 10.1016/0167-2738(94)00171-N
Development of an Electrode/Electrolyte Interface Model Based on Pseudo-Distributed Elements Combining COMSOL, MATLAB and HSPICE, 2nd International Conference on Bio-Sensing Technology, pp.69-78, 2012. ,
DOI : 10.1016/j.proche.2012.10.132
CNS plasticity and assessment of forelimb sensorimotor outcome in unilateral rat models of stroke, cortical ablation, parkinsonism and spinal cord injury, Neuropharmacology, vol.39, issue.5, pp.39777-787, 2000. ,
DOI : 10.1016/S0028-3908(00)00005-8
A High-Level Simulink-Based Tool for FPAA Configuration, IEEE Transactions on Very Large Scale Integration (VLSI) Systems, vol.20, issue.1, pp.10-18, 2012. ,
DOI : 10.1109/TVLSI.2010.2091687
The future of lithium and lithium-ion batteries in implantable medical devices, Journal of Power Sources, vol.97, issue.98, pp.97-98742, 2001. ,
DOI : 10.1016/S0378-7753(01)00648-6
Reinforcement value of sucrose measured by progressive ratio operant licking in the rat, Physiology & Behavior, vol.79, issue.4-5, pp.4-5663, 2003. ,
DOI : 10.1016/S0031-9384(03)00143-4
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface, IEEE Transactions on Biomedical Circuits and Systems, vol.4, issue.3, p.13, 2010. ,
DOI : 10.1109/TBCAS.2010.2041350
A model of safe levels for electrical stimulation, IEEE Transactions on Biomedical Engineering, vol.39, issue.4, pp.424-426, 1992. ,
DOI : 10.1109/10.126616
Neuromorphic hardware for rapid sparse coding, 2012 IEEE Biomedical Circuits and Systems Conference (BioCAS), pp.396-399, 2012. ,
DOI : 10.1109/BioCAS.2012.6418413
A linearized current stimulator for deep brain stimulation, Conf. Proc. IEEE Eng. Med. Biol. Soc, pp.6485-6493, 2010. ,
CMOS current-copying neural stimulator with OTA-sharing, Proceedings of 2010 IEEE International Symposium on Circuits and Systems, pp.1232-1235, 2010. ,
DOI : 10.1109/ISCAS.2010.5537284
A Low-Power Blocking-Capacitor-Free Charge-Balanced Electrode-Stimulator Chip With Less Than 6 nA DC Error for 1-mA Full-Scale Stimulation, IEEE Transactions on Biomedical Circuits and Systems, vol.1, issue.3, pp.172-83, 2007. ,
DOI : 10.1109/TBCAS.2007.911631
A Variable Range Bi-phasic Current Stimulus Driver Circuitry for an Implantable Retinal Prosthetic Device, IEEE Journal of Solid-State Circuits, issue.3, p.409, 2005. ,
Nonlinear modeling of neural population dynamics for hippocampal prostheses, Neural Networks, vol.22, issue.9, pp.1340-1351, 2009. ,
DOI : 10.1016/j.neunet.2009.05.004
A Neural Stimulator Output Stage for Dodecapolar Electrodes, 2008 IEEE Computer Society Annual Symposium on VLSI, pp.487-490, 2008. ,
DOI : 10.1109/ISVLSI.2008.84
URL : https://hal.archives-ouvertes.fr/lirmm-00279905
Stimulation of the rat subthalamic nucleus is neuroprotective following significant nigral dopamine neuron loss, Neurobiology of Disease, vol.39, issue.1, pp.105-120, 2010. ,
DOI : 10.1016/j.nbd.2010.03.009
Floating-gates transistors for precision analog circuit design: an overview, 48th Midwest Symposium on Circuits and Systems, 2005., pp.71-74, 2005. ,
DOI : 10.1109/MWSCAS.2005.1594042
A micropower low-noise monolithic instrumentation amplifier for medical purposes. Solid-State Circuits, IEEE Journal, vol.22, issue.6, pp.1163-1168, 1987. ,
CMOS neurostimulation ASIC with 100 channels, scaleable output, and bidirectional radio-frequency telemetry, IEEE Transactions on Biomedical Engineering, vol.48, issue.2, p.13, 2001. ,
DOI : 10.1109/10.909646
Biblia naturae. Leyden: Isaack Severinus, Boubowyn Vander and Peter Vander, 1758. ,
New Implantable Stimulator for the FES of Paralyzed Muscles. Solid-State Circuits Conference, p.4, 2004. ,
URL : https://hal.archives-ouvertes.fr/lirmm-00108820
CMOS-Based Multichip Networked Flexible Retinal Stimulator Designed for Image-Based Retinal Prosthesis, IEEE Transactions on Electron Devices, vol.56, issue.11, pp.562577-2585, 2009. ,
DOI : 10.1109/TED.2009.2030552
Low-Power Vestibular Signal Processing Circuitry Utilizing a Filed-Programmable Analog Array, IEEE Transactions on Biomedical Circuits and Systems, vol.7, issue.3, p.6, 2012. ,
An implantable neural stimulator for Intraspinal MicroStimulation, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, p.4, 2012. ,
DOI : 10.1109/EMBC.2012.6346077
6-hydroxy-dopamine induced degeneration of central monoamine neurons, European Journal of Pharmacology, vol.5, issue.1, pp.107-117, 1968. ,
DOI : 10.1016/0014-2999(68)90164-7
Design of a current-steering implantable stimulator with electric field shifting for deep brain stimulation, 2010 Biomedical Circuits and Systems Conference (BioCAS), p.4, 2010. ,
DOI : 10.1109/BIOCAS.2010.5709596
A Tripolar Current-Steerin Stimulator ASIC for Field Shaping in Deep Brain Stimulation, IEEE Transactions on Biomedical Circuits and Systems, vol.6, issue.3, p.11, 2012. ,
Design of a low power 100 dB dynamic range integrator for an implantable neural stimulator, 2010 Biomedical Circuits and Systems Conference (BioCAS), pp.158-161, 2010. ,
DOI : 10.1109/BIOCAS.2010.5709595
Towards a Switched-Capacitor based Stimulator for efficient deep-brain stimulation, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010. ,
DOI : 10.1109/IEMBS.2010.5626290
Basic algorithms for the programming of deep brain stimulation in Parkinson's disease, Movement Disorders, vol.44, issue.S14, pp.284-293, 2006. ,
DOI : 10.1002/mds.20961
On the electricity excited by the mere contact of conducting substances of different kinds. in a letter from mr. alexander volta, frs professor of natural philosophy in the university of pavia, to the rt. hon. sir joseph banks, bart. kbprs, Philosophical Transactions of the Royal Society of London, pp.403-431, 1800. ,
A Switched-Mode Multichannel Neural Stimlulator with a Minimum Number of External Components, Circuits and Systems (ISCAS), 2013 IEEE International Symposium on, p.4, 2013. ,
Analog-to-digital converter technology comparison, Proceedings of 1994 IEEE GaAs IC Symposium, pp.217-219, 1994. ,
DOI : 10.1109/GAAS.1994.636970
Analog-to-digital converter survey and analysis. Selected Areas in Communications, IEEE Journal on, vol.17, issue.4, pp.539-550, 1999. ,
Vestibular prostheses: the engineering and biomedical issues, Journal of Vestibular Research, vol.12, issue.2, pp.95-113, 2003. ,
Respiratory muscle pacing with chronically implanted intramuscular Permaloc electrodes: A feasibility study, The Journal of Rehabilitation Research and Development, vol.48, issue.2, pp.103-114, 2011. ,
DOI : 10.1682/JRRD.2010.05.0086
Fabrication and Characterization of a Parylene-Based Three-Dimensional Microelectrode Array for Use in Retinal Prosthesis, Journal of Microelectromechanical Systems, vol.19, issue.2, pp.367-374, 2010. ,
DOI : 10.1109/JMEMS.2009.2039773
A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor, IEEE Transactions on Biomedical Circuits and Systems, vol.8, issue.3, pp.411-422, 2014. ,
DOI : 10.1109/TBCAS.2013.2278659
Power sources and electrical recharging strategies for implantable medical devices. Front. Energy Power Eng, China, vol.2, issue.1, pp.1-13, 2008. ,
Impact of Large-Scale Science on the United States: Big science is here to stay, but we have yet to make the hard financial and educational choices it imposes, Science, vol.134, issue.3473, pp.134161-164, 1961. ,
DOI : 10.1126/science.134.3473.161
An Energy-Efficient, Dynamic VOltage Scaling Neural Stimulator for a Proprioceptive Prosthesis, IEEE Transactions on Biomedical Circuits and Systems, vol.7, issue.2, p.10, 2013. ,
Cochlear implants: A remarkable past and a brilliant future, Hearing Research, vol.242, issue.1-2, pp.3-21, 2008. ,
DOI : 10.1016/j.heares.2008.06.005
A versatile multichannel direct-synthesized electrical stimulator for fes applications. Instrumentation and Measurement, IEEE Transactions on, vol.51, issue.1, pp.2-9, 2002. ,
Biomechanical and electromyogram characterization of neuroleptic-induced rigidity in the rat, Neuroscience, vol.147, issue.1, pp.183-96, 2007. ,
DOI : 10.1016/j.neuroscience.2007.02.045
CMOS current reference with supply and temperature compensation, Electronics Letters, vol.43, issue.25, pp.1422-1424, 2007. ,
DOI : 10.1049/el:20072528
A programmable bioamplifier on FPAA for in vivo neural recording, 2010 Biomedical Circuits and Systems Conference (BioCAS), pp.2010-114, 2010. ,
DOI : 10.1109/BIOCAS.2010.5709584
URL : https://hal.archives-ouvertes.fr/hal-00585043
Cochlear Implants: System Design, Integration, and Evaluation, IEEE Reviews in Biomedical Engineering, vol.1, pp.115-142, 2008. ,
DOI : 10.1109/RBME.2008.2008250
A simple miniature device for wireless stimulation of neural circuits in small behaving animals, Journal of Neuroscience Methods, vol.202, issue.1, p.8, 2011. ,
DOI : 10.1016/j.jneumeth.2011.07.020
Design of a Neural Stimulator System with Closed-Loop Charge Cancellation. VLSI and System-on-Chip (VLSI-SoC), 2012 IEEE/IFIP 20th International Conference on, p.6, 2012. ,