B. Serhal, C. Jacobs, R. Flygare, L. Quirynen, M. Van-steenberghe et al., Perioperative validation of localisation of the mental foramen, Dentomaxillofacial Radiology, vol.31, issue.1, pp.39-43, 2002.
DOI : 10.1038/sj.dmfr.4600662

R. Jung, D. Schneider, J. Ganeles, D. Wismeijer, M. Zwahlen et al., Computer technology applications in surgical implant dentistry: a systematic review, Int J Oral Maxillofac Implants, vol.24, pp.92-109, 2009.

D. Schneider, P. Marquardt, M. Zwahlen, and R. Jung, A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry, Clinical Oral Implants Research, vol.10, issue.(Suppl. 1), pp.73-86, 2009.
DOI : 10.1111/j.1600-0501.2009.01788.x

D. 'haese, J. Van-de-velde, T. Komiyama, A. Hultin, M. et al., Accuracy and Complications Using Computer-Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature, Clinical Implant Dentistry and Related Research, vol.18, issue.1, pp.321-356, 2012.
DOI : 10.1111/j.1708-8208.2010.00275.x

D. Van-steenberghe, R. Glauser, and U. Blomback, A Computed Tomographic Scan???Derived Customized Surgical Template and Fixed Prosthesis for Flapless Surgery and Immediate Loading of Implants in Fully Edentulous Maxillae: A Prospective Multicenter Study, Clinical Implant Dentistry and Related Research, vol.3, issue.s1, pp.111-120, 2005.
DOI : 10.1034/j.1600-0501.2001.012002167.x

R. Jacobs, Accuracy of implant placement based on pre-surgical planning of threedimensional cone-beam images: a pilot study, J Clin Periodontol, vol.34, pp.816-821, 2007.

A. Pettersson, T. Kero, L. Gillot, B. Cannas, J. Faldt et al., Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I, The Journal of Prosthetic Dentistry, vol.103, issue.6, pp.334-342, 2010.
DOI : 10.1016/S0022-3913(10)60072-8

A. Pettersson, A. Komiyama, M. Hultin, K. Nasstrom, and B. Klinge, Accuracy of Virtually Planned and Template Guided Implant Surgery on Edentate Patients, Clinical Implant Dentistry and Related Research, vol.20, issue.4, 2010.
DOI : 10.1111/j.1708-8208.2010.00285.x

F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, and P. Suetens, Multimodality image registration by maximization of mutual information, IEEE Transactions on Medical Imaging, vol.16, issue.2, pp.187-198, 1997.
DOI : 10.1109/42.563664

P. Suetens, An image guided planning system for endosseous oral implants, IEEE Trans Med Imaging, vol.17, pp.842-852, 1998.

C. Aparicio, P. Perales, and B. Rangert, Tilted Implants as an Alternative to Maxillary Sinus Grafting: A Clinical, Radiologic, and Periotest Study, Clinical Implant Dentistry and Related Research, vol.9, issue.1, pp.39-49, 2001.
DOI : 10.1034/j.1600-0501.1997.080604.x

D. Atwood, Some clinical factors related to rate of resorption of residual ridges

J. Brief, D. Edinger, S. Hassfeld, and G. Eggers, Accuracy of image-guided implantology, Clinical Oral Implants Research, vol.107, issue.(Suppl. 1 Part
DOI : 10.1111/j.1600-0501.2005.01133.x

V. Gardette, Principes d'une démarche d'assurance qualité, évaluation des pratiques professionnels. Cours DCEM2 -Toulouse -http

A. Donabedian, Explorations in quality assessment and monitoring. Vol. I. The definition of quality and approaches to its assessment, II. The criteria and standards of quality, 1980.

A. Walter and . Shewhart, Statistical Method from the Viewpoint of Quality Control, 1939.

B. Comte, Recherche et développement d'une représentation à objets multipoints de vue dans le cadre de l'assurance qualité en santé bucco-dentaire, Thèse de doctorat, 1999.

A. Poyet, Le dispositif médical : aspects réglementaires et économiques Evolution sur les dix dernières années 12 -http://has-sante.fr/portail, Th.D. Pharm, 2003.

. Collectif-académie-nationale-de-médecine, Recommandations pour améliorer l'évaluation et le contrôle des dispositifs médicaux, 2003.

A. Du, fixant les règles de classification des dispositifs médicaux, pris en application de l'article R. 5211-7 du code de la santé publique 16 -Annexe IX de la directive 93, 2006.

. Afssaps_protheses_dentaires_2009 and . Pdf, 19 -http://ansm.sante.fr/Activites/Mise-sur-le-marche-des-dispositifs-medicaux-et-dispositifsmedicaux-de-diagnostic-in-vitro-DM-DMIA-DMDIV/Dispositifs-medicaux-sur-mesure, p.11

T. Jemt and J. Johansson, Implant Treatment in the Edentulous Maxillae: A 15-Year Follow-Up Study on 76 Consecutive Patients Provided with Fixed Prostheses, Clinical Implant Dentistry and Related Research, vol.16, issue.2, pp.61-70, 2006.
DOI : 10.1902/jop.2004.75.10.1404

P. Brånemark, Introduction to osseointegration Tissue-Integrated Prostheses -Osseointegration in Clinical Dentistry

R. Noharet, B. Cannas, and L. Gillot, Traitements des zones maxillaires atrophiées, Journal de Parodontologie et Implantologie Orale, vol.201130, issue.2, pp.91-106

N. Lang and S. Jepsen, Working Group 4. Implant surfaces and design (Working Group 4) Clin Oral Implants Res, pp.228-259, 2009.

C. Aparicio, B. Rangert, and L. Sennerby, Immediate/Early Loading of Dental Implants: a Report from the Sociedad Espanola de Implantes World Congress Consensus Meeting in Barcelona, Spain, 2002, Clinical Implant Dentistry and Related Research, vol.9, issue.1, pp.57-60, 2002.
DOI : 10.1067/mpr.2002.121111

S. Szmukler-moncler, H. Salama, Y. Reingewirtz, and J. Dubruille, Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature, Journal of Biomedical Materials Research, vol.4, issue.2, pp.192-203, 1998.
DOI : 10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K

M. Esposito, M. Grusovin, H. Maghaireh, and H. Worthington, Interventions for replacing missing teeth: different times for loading dental implants. Cochrane Database Syst Rev, 2013.
DOI : 10.1002/14651858.cd003878.pub4

A. Komiyama, B. Klinge, and M. Hultin, Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery, Clinical Oral Implants Research, vol.17, issue.1
DOI : 10.1111/j.1600-0501.2004.01069.x

A. Sanna, M. L. Van-steenberghe, and D. , Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: A cohort study of consecutive patients, The Journal of Prosthetic Dentistry, vol.97, issue.6, pp.331-340, 2007.
DOI : 10.1016/S0022-3913(07)60021-3

P. Malo, M. De-araujo-nobre, and A. Lopes, The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: Preliminary results after a mean follow-up period of thirteen months, The Journal of Prosthetic Dentistry, vol.97, issue.6, pp.26-34, 2007.
DOI : 10.1016/S0022-3913(07)60005-5

L. Yong and P. Moy, Complications of Computer-Aided-Design/Computer-Aided-Machining-Guided (NobelGuide???) Surgical Implant Placement: An Evaluation of Early Clinical Results, Clinical Implant Dentistry and Related Research, vol.17, issue.3, pp.123-130, 2008.
DOI : 10.1111/j.1708-8208.2007.00082.x

B. Johansson, B. Friberg, and H. Nilson, Digitally planned, immediately loaded dental implants with prefabricated prostheses in the reconstruction of edentulous maxillae: a 1-year prospective, multicenter study, Clin Implant Dent Relat Res, vol.11, issue.3, 2008.

N. Bellaïche, Radiologie conventionnelle et scanner en implantologie, le fil dentaire N° 41, pp.34-37, 2009.

N. Bellaïche, Place de la technologie Cone-Beam en imagerie odontostomatologique. La lettre de la Stomatologie, pp.4-14, 2009.

A. Pettersson, Accuracy of virtually planned and CAD/CAM-guided dental implant surgery

A. Voulgarakis, J. Strub, and W. Att, Outcomes of implants placed with three different flapless surgical procedures: A systematic review, International Journal of Oral and Maxillofacial Surgery, vol.43, issue.4, pp.476-86, 2013.
DOI : 10.1016/j.ijom.2013.10.024

E. Nkenke, S. Eitner, M. Radespiel-tröger, E. Vairaktaris, F. Neukam et al., Patient-centred outcomes comparing transmucosal implant placement with an open approach in the maxilla: a prospective, non-randomized pilot study, Clinical Oral Implants Research, vol.17, issue.2, pp.197-203, 2007.
DOI : 10.1111/j.1708-8208.2005.tb00083.x

M. Hultin, K. Svensson, and M. Trulsson, Clinical advantages of computer-guided implant placement: a systematic review, Clinical Oral Implants Research, vol.10, issue.Suppl 1, pp.124-159, 2012.
DOI : 10.1111/j.1600-0501.2012.02545.x

R. Noharet and M. Jurado, Anticipations implantaires et prothétiques dans le traitement de l'édenté partiel maxillaire postérieur, Stratégie Prothétique, vol.12, issue.5, pp.281-91, 2012.

S. Annibali, M. Cristalli, D. Dell-'aquila, I. Bignozzi, L. Monaca et al., Short Dental Implants: A Systematic Review, Journal of Dental Research, vol.91, issue.1, pp.91-116, 2012.
DOI : 10.1177/0022034511425675

M. Esposito, G. Cannizzaro, E. Soardi, R. Pistilli, M. Piattelli et al., Posterior atrophic jaws rehabilitated with prostheses supported by 6 mm-long, 4 mm-wide implants or by longer implants in augmented bone

A. Monje, J. Fu, H. Chan, F. Suarez, P. Galindo-moreno et al., Do Implant Length and Width Matter for Short Dental Implants (<10 mm)? A Meta-Analysis of Prospective Studies, Journal of Periodontology, vol.84, issue.12, pp.1783-91, 2013.
DOI : 10.1902/jop.2013.120745

M. Srinivasan, L. Vazquez, P. Rieder, O. Moraguez, J. Bernard et al., Survival rates of short (6??mm) micro-rough surface implants: a review of literature and meta-analysis, Clinical Oral Implants Research, vol.13, issue.Suppl. 2
DOI : 10.1111/clr.12125

E. Anitua, M. Alkhraisat, L. Piñas, and G. Orive, Efficacy of biologically guided implant site preparation to obtain adequate primary implant stability, Annals of Anatomy - Anatomischer Anzeiger, vol.199, 2014.
DOI : 10.1016/j.aanat.2014.02.005

F. Renouard and D. Et-nisand, Impact of implant length and diameter on survival rates, Clinical Oral Implants Research, vol.19, issue.S2, pp.35-51, 2006.
DOI : 10.1902/annals.2000.5.1.22

F. Neves, D. Fones, S. Bernardes, C. Prado, and A. Neto, Short implants???an analysis of longitudinal studies, The Journal of Prosthetic Dentistry, vol.96, issue.4, pp.86-93, 2006.
DOI : 10.1016/j.prosdent.2006.05.023

. Espositom, M. Grusovin, Y. Chew, P. Coulthard, and H. Worthington, One-stage versus two-stage implant placement. A Cochrane systematic review of randomised controlled clinical trials, Eur J Oral Implantol, vol.2, issue.2, pp.91-100, 2009.

. Birdih, J. Schulte, A. Kovacs, M. Weed, and S. Chuang, Crown-to-Implant Ratios of Short-Length Implants, Journal of Oral Implantology, vol.36, issue.6, pp.425-458, 2010.
DOI : 10.1563/AAID-JOI-D-09-00071

B. Yilmaz, J. Seidt, E. Mcglumphy, and N. Clelland, Comparison of strains for splinted and nonsplinted screw-retained prostheses on shortimplants, Int J Oral Maxillofac Implants, 2011.

T. Yang, Y. Maeda, and T. Gonda, Biomechanical rationale for short implants in splinted restorations: an in vitro study, Int J Prosthodont, vol.24, issue.2, pp.130-132, 2011.

J. Mendonça, C. Francischone, P. Senna, A. Matos-de-oliveira, and B. Sotto-maior, A Retrospective Evaluation of the Survival Rates of Splinted and Nonsplinted Short Dental Implants in Posterior Partially Edentulous Jaws, J Periodontol, 2013.

D. Santos, M. Elias, C. , C. Lima, and J. , The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants, Clinical Implant Dentistry and Related Research, vol.26, issue.3, 2011.
DOI : 10.1111/j.1708-8208.2009.00202.x

B. Pommer, S. Frantal, J. Willer, M. Posch, G. Watzek et al., Impact of dental implant length on early failure rates: a meta-analysis of observational studies, Journal of Clinical Periodontology, vol.10, issue.(S, pp.38-856, 2011.
DOI : 10.1111/j.1600-051X.2011.01750.x

A. Wennerberg and T. Et-albrektsson, Effects of titanium surface topography on bone integration: a systematic review, Clinical Oral Implants Research, vol.16, issue.4, pp.172-84, 2009.
DOI : 10.1111/j.1600-0501.2009.01775.x

C. Aparicio, P. Perales, and B. Rangert, Tilted Implants as an Alternative to Maxillary Sinus Grafting: A Clinical, Radiologic, and Periotest Study, Clinical Implant Dentistry and Related Research, vol.9, issue.1, pp.39-49, 2001.
DOI : 10.1034/j.1600-0501.1997.080604.x

D. Fabbro, M. Bellini, C. Romeo, D. Francetti, and L. , Tilted Implants for the Rehabilitation of Edentulous Jaws: A Systematic Review, Clinical Implant Dentistry and Related Research, vol.99, issue.6, pp.1-10, 2010.
DOI : 10.1111/j.1708-8208.2010.00288.x

D. Steenberghe, P. Van-der-stelt, and . European, Association for Osseointegration E.A.O. guidelines for the use of diagnostic imaging in implant dentistry. A consensus workshop organized by the European Association for Osseointegration in Trinity College Dublin, Clin Oral Implants Res, 2002.

F. Brugnami and C. Caleffi, Prosthetically driven Implant Placement. How to achieve the appropriate implant site development, Prosthetically driven implant placement. How to achieve the appropriate implant site development, pp.172-180, 2005.
DOI : 10.2302/kjm.54.172

L. Ensuite and . Qualité-du-traitement-implantaire-est-discutée, des bases historiques jusqu'aux connaissances d'aujourd'hui. Il est important de maitriser l'évolution de cette technique et des outils associées afin de comprendre et donc d'utiliser les outils diagnostics et thérapeutiques à notre disposition aujourd'hui. Le dernier temps de ce travail constitue l'évaluation des outils actuels en implantologie (CFAO, stéréolithographie, chirurgie guide statique, informatique) au travers d'une étude sur sujets anatomiques, Cette étude évalue la précision du positionnement implantaire avec des guides dits conventionnels et des guides de chirurgie guidée statique

. Rubrique-de-classement, Implantologie Mots-clé français : Assurance qualité Dispositifs médicaux Placement implantaire Chirurgie guidée Mots-clés anglais : Quality assurance Medical devices Implant placement Guided Surgery Jury