Design of optimal 2-D non-grid sparse arrays for medical ultrasoundVariable-size elements in 2D sparse arrays for 3D medical ultrasound, bibliography International journal, pp.3093-3102, 2013. ,
Non-grid based elements positioning for optimal 2D array beams, IEEE International Ultrasonics Symposium, pp.1-4, 2012. ,
Optimized 2-D array design for ultrasound imaging, EUSIPCO, pp.2718-2722, 2012. ,
2D matrix array optimization by simulated annealing for 3D hepatic imaging, 2011 IEEE International Ultrasonics Symposium, pp.1595-1598, 2011. ,
DOI : 10.1109/ULTSYM.2011.0396
A new scheme for curved needle segmentation in three-dimensional ultrasound images, 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp.1067-1070, 2009. ,
DOI : 10.1109/ISBI.2009.5193240
Which transducer array is best?, European Journal of Ultrasound, vol.2, issue.2, pp.151-164, 1995. ,
DOI : 10.1016/0929-8266(95)00092-5
Sparse arrays for real-time 3D imaging, simulated and experimental results, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121), pp.1187-1190, 2000. ,
DOI : 10.1109/ULTSYM.2000.921535
Sparse 2-D arrays for 3-D phased array imaging - design methods, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.49, issue.8, pp.1073-1086, 2002. ,
DOI : 10.1109/TUFFC.2002.1026019
Sparse 2-d arrays for 3-D phased array imaging-experimental validation, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.49, pp.1087-1093, 2002. ,
Ultrasonic B-scanning: a computer simulation, Physics in Medicine and Biology, vol.25, issue.3, pp.463-479, 1980. ,
DOI : 10.1088/0031-9155/25/3/006
Characterization of 1.5-D ultrasound transducer arrays, IEEE International Ultrasonics Symposium, vol.2, pp.1489-1493, 1996. ,
ULTRASOUND IMAGE POST-PROCESSING ??? APPLICATION TO SEGMENTATION, Physics for Medical Imaging Applications, NATO Science Series, pp.227-239, 2007. ,
DOI : 10.1007/978-1-4020-5653-6_17
Figure 17, color JPG, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.55, issue.2, pp.308-318, 2008. ,
DOI : 10.1109/TUFFC.2008.650/mm2
Mechanically assisted 3D ultrasound guided prostate biopsy system, Medical Physics, vol.66, issue.2, pp.35-5397, 2008. ,
DOI : 10.1016/0301-5629(95)00044-5
Sparse Array Optimization by Using the Simulated Annealing Algorithm, Numerical Methods and Applications, pp.223-230, 2007. ,
DOI : 10.1007/978-3-540-70942-8_26
Three- and Four-Dimensional Cardiovascular Ultrasound Imaging: A New Era for Echocardiography, Mayo Clinic Proceedings, vol.68, issue.3, pp.68-221, 1993. ,
DOI : 10.1016/S0025-6196(12)60042-1
Figure 5, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.59, issue.7, pp.59-1378, 2012. ,
DOI : 10.1109/TUFFC.2012.2338/mm3
Fourier Transforms in Radar and Signal Processing, 2012. ,
The Core Curriculum: Ultrasound, 2001. ,
Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.44, issue.5, pp.1101-1109, 1997. ,
DOI : 10.1109/58.655635
A two-dimensional transducer array for real-time 3D medical ultrasound imaging, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102), pp.1065-1068, 1998. ,
DOI : 10.1109/ULTSYM.1998.765012
Volumetric ultrasound system for left ventricle motion imaging, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.46, issue.6, pp.1527-1538, 1999. ,
DOI : 10.1109/58.808877
Enhancing Sparsity by Reweighted ??? 1 Minimization, Journal of Fourier Analysis and Applications, vol.7, issue.3, pp.877-905, 2008. ,
DOI : 10.1007/s00041-008-9045-x
Planar antenna array design with a multi-purpose GA-based procedure, Microwave and Optical Technology Letters, vol.46, issue.6, pp.428-430, 2002. ,
DOI : 10.1002/mop.10629
URL : https://hal.archives-ouvertes.fr/hal-01169807
Optimization of wide-band linear arrays, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.48, issue.4, pp.943-952, 2001. ,
DOI : 10.1109/58.935711
Rough Large Deviation Estimates for Simulated Annealing: Application to Exponential Schedules, The Annals of Probability, vol.20, issue.3, pp.1109-1146, 1992. ,
DOI : 10.1214/aop/1176989682
Optimized simulated annealing algorithm for thinning and weighting large planar arrays, Journal of Zhejiang University SCIENCE C, vol.11, issue.4, pp.261-269, 2010. ,
DOI : 10.1631/jzus.C0910037
A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, pp.837-847, 2009. ,
Optimization and Beamforming of a Two Dimensional Sparse Array, High Performance Computing, p.98, 1998. ,
1.5-D high intensity focused ultrasound array for non-invasive prostate cancer surgery, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.49, issue.2, pp.231-242, 2002. ,
DOI : 10.1109/58.985707
URL : https://hal.archives-ouvertes.fr/hal-01466197
A 1.5D transducer for medical ultrasound, Proceedings of IEEE Ultrasonics Symposium ULTSYM-94, pp.1491-1495, 1994. ,
DOI : 10.1109/ULTSYM.1994.401873
2-D array for 3-D ultrasound imaging using synthetic aperture techniques, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.53, issue.5, pp.912-924, 2006. ,
DOI : 10.1109/TUFFC.2006.1632682
Iteratively reweighted least squares minimization for sparse recovery, Communications on Pure and Applied Mathematics, vol.58, issue.1, pp.1-38, 2010. ,
DOI : 10.1002/cpa.20303
An efficient 3D beamformer implementation for real-time 4D ultrasound systems deploying planar array probes, IEEE Ultrasonics Symposium, 2004, pp.1421-1424, 2004. ,
DOI : 10.1109/ULTSYM.2004.1418067
Non-grid based elements positioning for optimal 2D array beams, 2012 IEEE International Ultrasonics Symposium, 2012. ,
DOI : 10.1109/ULTSYM.2012.0388
URL : https://hal.archives-ouvertes.fr/hal-00830790
Optimized 2D array design for Ultrasound imaging, European Signal Processing Conference, pp.2718-2722, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00830916
2D matrix array optimization by simulated annealing for 3D hepatic imaging, 2011 IEEE International Ultrasonics Symposium, pp.1595-1598, 2011. ,
DOI : 10.1109/ULTSYM.2011.0396
Sparse array techniques for 2D array ultrasound imaging, pp.1591-1596, 2012. ,
Variable-size elements in 2D sparse arrays for 3D medical ultrasound, IEEE International Ultrasonics Symposium, 2013. ,
Design of optimal 2- D non-grid sparse arrays for medical ultrasound, IEEE Transactions on Biomedical Engineering, issue.99, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-00850032
A real-time biopsy needle segmentation technique using Hough Transform, Medical Physics, vol.21, issue.8, pp.2222-2233, 2003. ,
DOI : 10.1118/1.1591192
Fabrication and evaluation of fully-sampled, two-dimensional transducer array for ???Sonic Window??? imaging system, Ultrasonics, vol.48, issue.5, pp.376-383, 2008. ,
DOI : 10.1016/j.ultras.2008.01.011
High element count [3600], fully sampled, two dimensional transducer array, IEEE Ultrasonics Symposium, 2005., pp.2243-2246, 2005. ,
DOI : 10.1109/ULTSYM.2005.1603330
Synthetic elevation beamforming and image acquisition capabilities using an 8 /spl times/ 128 1.75D array, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.50, issue.1, pp.40-57, 2003. ,
DOI : 10.1109/TUFFC.2003.1176524
Personal communication, 2013. ,
A portable, low-cost, highly integrated, 3D medical ultrasound system, IEEE Symposium on Ultrasonics, 2003, pp.38-41, 2003. ,
DOI : 10.1109/ULTSYM.2003.1293352
Experimental System Prototype of a Portable, Low-Cost, C-Scan Ultrasound Imaging Device, IEEE Transactions on Biomedical Engineering, vol.55, issue.2, pp.519-530, 2008. ,
DOI : 10.1109/TBME.2007.903517
Narrow-band volume rendering for freehand 3D ultrasound, Computers & Graphics, vol.26, issue.3, pp.463-476, 2002. ,
DOI : 10.1016/S0097-8493(02)00089-4
Engineering a freehand 3D ultrasound system, Pattern Recognition Letters, vol.24, issue.4-5, pp.4-5, 2003. ,
DOI : 10.1016/S0167-8655(02)00180-0
High element count two dimensional transducer array, IEEE Symposium on Ultrasonics, 2003, pp.964-967, 2003. ,
DOI : 10.1109/ULTSYM.2003.1293559
Dense and sparse 2-D array radiation patterns in lossy media, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.47, issue.4, pp.940-948, 2000. ,
DOI : 10.1109/58.852077
Marshall Rosenbluth and the Metropolis algorithm, Physics of Plasmas, vol.12, issue.5, p.57303, 2005. ,
DOI : 10.1063/1.1887186
Cooling Schedules for Optimal Annealing, Mathematics of Operations Research, vol.13, issue.2, pp.311-329, 1988. ,
DOI : 10.1287/moor.13.2.311
Rotationally acquired four-dimensional optical coherence tomography of embryonic chick hearts using retrospective gating on the common central A-scan, Journal of Biomedical Optics, vol.16, issue.9, 2011. ,
DOI : 10.1117/1.3622491.3
Thinned arrays using genetic algorithms, IEEE Transactions on Antennas and Propagation, vol.42, issue.7, pp.993-999, 1994. ,
DOI : 10.1109/8.299602
Transthoracic Ultrasound, Respiration, vol.70, issue.1, pp.87-94, 2003. ,
DOI : 10.1159/000068420
Sparse and irregular sampling in array processing, 2000 IEEE International Conference on Acoustics, Speech, and Signal Processing. Proceedings (Cat. No.00CH37100), pp.3850-3853, 2000. ,
DOI : 10.1109/ICASSP.2000.860243
Sparse sampling in array processing Sampling Theory and Practice, 2001. ,
Properties of the beampattern of weight- and layout-optimized sparse arrays, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.44, issue.5, pp.983-991, 1997. ,
DOI : 10.1109/58.655623
Optimization of sparse arrays by an improved simulated annealing algorithm, International Workshop on Sampling Theory and Applications, pp.91-95, 1999. ,
Calibration of an orientation sensor for freehand 3D ultrasound and its use in a hybrid acquisition system, BioMedical Engineering OnLine, vol.7, issue.1, 2008. ,
DOI : 10.1186/1475-925X-7-5
FIELD: A Program for Simulating Ultrasound Systems, 10th Nordic- Baltic Conference on Biomedical Imaging, pp.351-353, 1996. ,
Experimental ultrasound system for real-time synthetic imaging, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027), pp.1595-1599, 1999. ,
DOI : 10.1109/ULTSYM.1999.849300
Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.39, issue.2, pp.262-267, 1992. ,
DOI : 10.1109/58.139123
A study of two-dimensional array transducers for limited diffraction beams, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.41, issue.5, pp.724-739, 1994. ,
DOI : 10.1109/58.308509
Phased subarray processing for underwater 3D acoustic imaging, Oceans '02 MTS/IEEE, pp.2145-2151, 2002. ,
DOI : 10.1109/OCEANS.2002.1191962
URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.576.4984
Minimally Redundant 2-D Array Designs for 3-D Medical Ultrasound Imaging, IEEE Transactions on Medical Imaging, vol.28, issue.7, pp.28-1051, 2009. ,
DOI : 10.1109/TMI.2008.2010936
Synthesis of Sparse Planar Arrays Using Modified Real Genetic Algorithm, IEEE Transactions on Antennas and Propagation, vol.55, issue.4, pp.1067-1073, 2007. ,
Optimization by Simulated Annealing, Science, vol.220, issue.4598, pp.671-680, 1983. ,
DOI : 10.1126/science.220.4598.671
Three-Dimensional Ultrasound in Soft Tissue Tumor Imaging, Current Medical Imaging Reviews, vol.5, issue.4, pp.210-215, 2009. ,
DOI : 10.2174/157340509790112862
Matrix Array Transducer and Flexible Matrix Arry Transducer, IEEE 1986 Ultrasonics Symposium, pp.649-654, 1986. ,
DOI : 10.1109/ULTSYM.1986.198816
Assessment of left ventricular function by three-dimensional echocardiography, Cardiovascular Ultrasound, vol.16, issue.1, p.12, 2003. ,
DOI : 10.1067/mje.2003.40
Simulated Annealing: Theory and Applications, 1987. ,
DOI : 10.1007/978-94-015-7744-1
A? l'intérieur? d'une? barrette? échographique, 1998. ,
Sequential Turning Acquisition and Reconstruction (STAR) method for four-dimensional imaging of cyclically moving structures, Biomedical Optics Express, vol.3, issue.3, p.650, 2012. ,
DOI : 10.1364/BOE.3.000650.m004
Transthoracic hepatic radiofrequency ablation, Surgical Endoscopy, vol.12, issue.11, pp.1672-1674, 2004. ,
DOI : 10.1007/s00464-004-8110-z
US-guided Transthoracic Cutting Biopsy for Peripheral Thoracic Lesions Less than 3 cm in Diameter, Radiology, vol.217, issue.3, pp.685-691, 2000. ,
DOI : 10.1148/radiology.217.3.r00dc21685
Fourier domain beamforming for transverse-oscillations, 2010 IEEE International Ultrasonics Symposium, pp.1755-1758, 2010. ,
DOI : 10.1109/ULTSYM.2010.5935762
P3H-2 Improved Beamforming for Lateral Oscillations in Elastography Using Synthetic Aperture Imaging, 2006 IEEE Ultrasonics Symposium, pp.2168-2171, 2006. ,
DOI : 10.1109/ULTSYM.2006.548
Figure 15, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.55, issue.9, pp.2066-2078, 2008. ,
DOI : 10.1109/TUFFC.898/mm3
Advances in two dimensional arrays for real time volumetric imaging, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118), pp.1619-1623, 1997. ,
DOI : 10.1109/ULTSYM.1997.663305
Texture-based instrument segmentation in 3D ultrasound images, Medical Imaging 2006: Image Processing, pp.61443-61443, 2006. ,
DOI : 10.1117/12.649980
Optimizing the radiation pattern of sparse periodic two-dimensional arrays, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.43, issue.1, pp.15-19, 1996. ,
DOI : 10.1109/58.484458
Sidelobe reduction in sparse linear arrays by genetic algorithms, Microwave and Optical Technology Letters, vol.38, issue.3, pp.194-196, 2002. ,
DOI : 10.1002/mop.10128
An Introduction to Underwater Acoustics: Principles and Applications, 2002. ,
Efficient digital beamforming in the frequency domain, The Journal of the Acoustical Society of America, vol.86, issue.5, pp.1813-1819, 1989. ,
DOI : 10.1121/1.398614
Modeling and simulation of ultrasound fields generated by 2D phased array transducers for medical applications, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, pp.6003-6006, 2010. ,
DOI : 10.1109/IEMBS.2010.5627588
Simulating ultrasound fields for 2D phased-array probes design optimization, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp.8507-8510, 2011. ,
DOI : 10.1109/IEMBS.2011.6092099
Simulations of circular 2D phase-array ultrasonic imaging transducers, Ultrasonics, vol.39, issue.9, pp.657-666, 2002. ,
DOI : 10.1016/S0041-624X(02)00266-4
Ultrasonic texture motion analysis: theory and simulation, IEEE Transactions on Medical Imaging, vol.14, issue.2, pp.293-300, 1995. ,
DOI : 10.1109/42.387711
Theoretical assessment of a crossed electrode 2-D array for 3-D imaging, IEEE Symposium on Ultrasonics, 2003, pp.968-971, 2003. ,
DOI : 10.1109/ULTSYM.2003.1293560
A comparison of efficient beamforming algorithms, IEEE Transactions on Acoustics, Speech, and Signal Processing, vol.32, issue.3, pp.548-558, 1984. ,
DOI : 10.1109/TASSP.1984.1164359
Underwater 3D imaging by FFT dynamic focusing beamforming, Proceedings of 1st International Conference on Image Processing, pp.169-172, 1994. ,
DOI : 10.1109/ICIP.1994.413242
Synthesis of unequally spaced arrays by simulated annealing, IEEE Transactions on Signal Processing, vol.44, issue.1, pp.119-122, 1996. ,
DOI : 10.1109/78.482017
Sonar Signal Processing, 1991. ,
Investigation of the feasibility of 3D synthetic aperture imaging, IEEE Symposium on Ultrasonics, 2003, pp.1903-1906, 2003. ,
DOI : 10.1109/ULTSYM.2003.1293287
Real time 3D visualization of ultrasonic data using a standard PC, IEEE Ultrasonics, issue.6, pp.41-421, 2003. ,
Methods for segmenting curved needles in ultrasound images, Medical Image Analysis, vol.10, issue.3, pp.330-342, 2006. ,
DOI : 10.1016/j.media.2006.01.002
4-D x 3-D ultrasound: real-time scan conversion, filtering, and display of displacement vectors with a motorized curvilinear transducer, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.57, issue.10, pp.57-2271, 2010. ,
DOI : 10.1109/TUFFC.2010.1688
Elevation beamforming performance of a 1.75 D array, IEEE International Ultrasonics Symposium, pp.1113-1116, 2001. ,
Ultrasonic calibration material and method, 1993. ,
Real time volumetric ultrasound imaging system, Journal of Digital Imaging, vol.76, issue.4, pp.261-266, 1990. ,
DOI : 10.1007/BF03168124
Theoretically Grounded Acceleration Techniques for Simulated Annealing Handbook of Optimization, Intelligent Systems Reference Library, pp.311-335, 2013. ,
Simulated annealing, acceleration techniques, and image restoration, IEEE Transactions on Image Processing, vol.8, issue.10, pp.1374-1387, 1999. ,
DOI : 10.1109/83.791963
From simulated annealing to stochastic continuation: a new trend in combinatorial optimization, Journal of Global Optimization, vol.104, issue.3, pp.185-215, 2013. ,
DOI : 10.1007/s10898-012-9860-0
URL : https://hal.archives-ouvertes.fr/hal-00850581
Accuracy of Transthoracic Sonography in Detection of Pneumothorax After Sonographically Guided Lung Biopsy: Prospective Comparison with Chest Radiography, American Journal of Roentgenology, vol.188, issue.1, pp.37-41, 2007. ,
DOI : 10.2214/AJR.05.1716
Fully sampled matrix transducer for real time 3D ultrasonic imaging, IEEE Symposium on Ultrasonics, 2003, pp.945-953, 2003. ,
DOI : 10.1109/ULTSYM.2003.1293556
Realistic Simulation of B-Scan Images, 1983 Ultrasonics Symposium, pp.714-717, 1983. ,
DOI : 10.1109/ULTSYM.1983.198151
Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays, The Journal of the Acoustical Society of America, vol.75, issue.4, pp.1273-1282, 1984. ,
DOI : 10.1121/1.390734
The Principle of Multidimensional Arrays, European Journal of Echocardiography, vol.3, issue.2, pp.149-153, 2002. ,
DOI : 10.1053/euje.2001.0139
High-speed ultrasound volumetric imaging system. II. Parallel processing and image display, IEEE Ultrasonics, vol.38, issue.2, pp.109-115, 1991. ,
High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.38, issue.2, pp.100-108, 1991. ,
DOI : 10.1109/58.68466
Methods and systems for selective processing of transmit ultrasound beams to display views of selected slices of a volume, 2001. ,
The Time???Dependent Force and Radiation Impedance on a Piston in a Rigid Infinite Planar Baffle, The Journal of the Acoustical Society of America, vol.49, issue.3B, pp.841-849, 1971. ,
DOI : 10.1121/1.1912424
Transient Radiation from Pistons in an Infinite Planar Baffle, The Journal of the Acoustical Society of America, vol.49, issue.5B, pp.1629-1638, 1971. ,
High-resolution real-time three-dimensional acoustic imaging system with a reflector, Journal of Medical Ultrasonics, vol.34, issue.3, pp.133-144, 2007. ,
Optimizing circular ring arrays for forward-loo ing IVUS imaging, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, issue.12, pp.58-2596, 2011. ,
Evolution of ultrasound beamformers, 1996 IEEE Ultrasonics Symposium. Proceedings, pp.1615-1622, 1996. ,
DOI : 10.1109/ULTSYM.1996.584398
Figure 9, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.10, pp.2207-2216, 2009. ,
DOI : 10.1109/TUFFC.2009.1303/mm4
A 128??4 channels 1.5D curved linear array for medical imaging, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium, pp.1331-1335, 1995. ,
DOI : 10.1109/ULTSYM.1995.495802
Thinning and weighting of large planar arrays by simulated annealing, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.46, issue.2, pp.347-355, 1999. ,
DOI : 10.1109/58.753023
Weighting and thinning wide-band arrays by simulated annealing, Ultrasonics, vol.40, issue.1-8, pp.485-489, 2002. ,
DOI : 10.1016/S0041-624X(02)00163-4
Devising an Affordable Sonar System for Underwater 3-D Vision, IEEE Transactions on Instrumentation and Measurement, vol.57, issue.10, pp.2348-2354, 2008. ,
DOI : 10.1109/TIM.2008.922111
A stochastic approach to optimizing the aperture and the number of elements of an aperiodic array, OCEANS 96 MTS/IEEE Conference Proceedings. The Coastal Ocean, Prospects for the 21st Century, pp.1510-1515, 1996. ,
DOI : 10.1109/OCEANS.1996.569134
Generation of acoustic pulses by baffled plane pistons, Mathematika, vol.7, issue.02, pp.209-224, 1969. ,
DOI : 10.1121/1.1907019
Beam steering with pulsed two-dimensional transducer arrays, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.38, issue.4, pp.320-333, 1991. ,
DOI : 10.1109/58.84270
Aperiodic and deterministic 2D phased array structures for ultrasonic imaging, 2009 IEEE International Ultrasonics Symposium, pp.406-409, 2009. ,
DOI : 10.1109/ULTSYM.2009.5441873
Model Fitting Using RANSAC for Surgical Tool Localization in 3-D Ultrasound Images, IEEE Transactions on Biomedical Engineering, vol.57, pp.1907-1916, 2010. ,
Nonlinear radio frequency image simulation for harmonic imaging: Creanuis, 2010 IEEE International Ultrasonics Symposium, pp.2179-2182, 2010. ,
DOI : 10.1109/ULTSYM.2010.5935538
1D- and 2D-Sparse-Array-Optimization, Instrumentation Science & Technology, vol.12, issue.4, pp.235-246, 1999. ,
DOI : 10.1016/0161-7346(92)90064-3
URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.128.7073
Optimization of random sparse 2-D transducer arrays for 3-D electronic beam steering and focusing, Proceedings of IEEE Ultrasonics Symposium ULTSYM-94, pp.1503-1506, 1994. ,
DOI : 10.1109/ULTSYM.1994.401875
Elevation performance of 1.25D and 1.5D transducer arrays, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.44, issue.5, pp.44-1027, 1997. ,
DOI : 10.1109/58.655628
Needle Segmentation Using 3D Quic Randomized Hough Transform, International Conference on Intelligent Networks and Intelligent Systems, pp.449-452, 2008. ,
DOI : 10.1109/icinis.2008.41
Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3D catheter-based ultrasonic imaging, Medical Imaging 2006: Ultrasonic Imaging and Signal Processing, pp.61470-61470, 2006. ,
DOI : 10.1117/12.673786
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.55, issue.2, pp.327-342, 2008. ,
DOI : 10.1109/TUFFC.2008.652
Real-Time 3-Dimensional Echocardiography: A Review of the Development of the Technology and Its Clinical Application, Progress in Cardiovascular Diseases, vol.48, issue.3, pp.48-209, 2005. ,
DOI : 10.1016/j.pcad.2005.07.002
A novel method to design sparse linear arrays for ultrasonic phased array, Ultrasonics, vol.44, issue.1, pp.717-721, 2006. ,
DOI : 10.1016/j.ultras.2006.05.131
Real-time rectilinear volumetric imaging using a periodic array, Ultrasound in Medicine and Biology, vol.28, issue.7, pp.923-931, 2002. ,
Parallelization and performance of 3D ultrasound imaging beamforming algorithms on modem clusters, International Conference on Supercomputing, 2002. ,
Orthogonal Genetic Algorithm for Planar Thinned Array Designs, International Journal of Antennas and Propagation, vol.3, issue.1, pp.1-7, 2012. ,
DOI : 10.1109/TEVC.2004.835176