]. P. Bibliographie, S. E. Abolmaesumi, W. H. Salcudean, S. P. Zhu, M. R. Dimaio et al., A user interface for robot-assisted diagnostic ultrasound, IEEE Int. Conf. on Robotics and Automation, ICRA'01, pp.1549-1554, 2001.

]. P. Abolmaesumi, S. Salcudean, W. Zhu, M. Sirouspour, and S. Dimaio, Image-guided control of a robot for medical ultrasound, IEEE Transactions on Robotics and Automation, vol.18, issue.1, pp.11-23, 2002.
DOI : 10.1109/70.988970

F. Allgower, T. A. Badgwell, S. J. Qin, J. B. Rawlings, and S. J. Wright, Nonlinear predictive control and moving horizon estimation -an introductory overwiew Advances in Control : Highlights of ECC'99, pp.391-449, 1999.

]. P. Arbeille, J. Ayoub, V. Kieffer, P. Ruiz, B. Combes et al., Realtime tele-operated abdominal and fetal echography in 4 medical centres, from one expert center, using a robotic arm & ISDN or satellite link, 2008 IEEE International Conference on Automation, Quality and Testing, Robotics, pp.45-46, 1976.
DOI : 10.1109/AQTR.2008.4588703

]. W. Bachta and A. Krupa, Towards ultrasound image-based visual servoing, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006., pp.4112-4117, 2006.
DOI : 10.1109/ROBOT.2006.1642334

URL : https://hal.archives-ouvertes.fr/inria-00350281

]. S. Baker and I. Matthews, Lucas-Kanade 20 Years On: A Unifying Framework, International Journal of Computer Vision, vol.56, issue.3, pp.221-255, 2004.
DOI : 10.1023/B:VISI.0000011205.11775.fd

]. A. Belaid, D. Boukerroui, Y. Maingourd, and J. F. Lerallut, Phase based level set segmentation of ultrasound images, 9th Int. Conf. on Information Technology and Applications in Biomedicine, pp.1-4, 2009.
URL : https://hal.archives-ouvertes.fr/hal-00551806

]. A. Benabid, P. Cinquin, S. Lavalle, J. F. Le-bas, J. Demongeot et al., Computer-Driven Robot for Stereotactic Surgery Connected to CT Scan and Magnetic Resonance Imaging, Stereotactic and Functional Neurosurgery, vol.50, issue.1-6, pp.153-154, 1987.
DOI : 10.1159/000100701

]. S. Bibliographie, E. Benhimane, and . Malis, Real-time image-based tracking of planes using efficient second-order minimization, IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, IROS'04, pp.943-948, 2004.

]. E. Boctor, I. Iordachita, G. Fichtinger, and G. D. Hager, Real-Time Quality Control of Tracked Ultrasound, Int. Conf. on Medical Image Computing and Computer- Assisted Intervention, MICCAI'05, pp.621-630, 2005.
DOI : 10.1007/11566465_77

]. L. Bohs, B. J. Geiman, M. E. Anderson, S. C. Gebhart, and G. E. Trahey, Speckle tracking for multi-dimensional flow estimation, Ultrasonics, vol.38, issue.1-8, pp.369-375, 2000.
DOI : 10.1016/S0041-624X(99)00182-1

]. F. Bookstein, Principal warps: thin-plate splines and the decomposition of deformations, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.11, issue.6, p.107, 1989.
DOI : 10.1109/34.24792

]. I. Bricault, N. Zemiti, E. Jouniaux, C. Fouard, E. Taillant et al., Light Puncture Robot for CT and MRI Interventions, IEEE Engineering in Medicine and Biology Magazine, vol.27, issue.3, pp.42-50, 2008.
DOI : 10.1109/EMB.2007.910262

URL : https://hal.archives-ouvertes.fr/hal-00387377

]. P. Brigger, J. Hoeg, and M. Unser, B-spline snakes: a flexible tool for parametric contour detection, IEEE Transactions on Image Processing, vol.9, issue.9, pp.1484-1496, 2000.
DOI : 10.1109/83.862624

]. A. Casal, J. Amat, and E. Laporte, Automatic guidance of an assistant robot in laparoscopic surgery, Proceedings of IEEE International Conference on Robotics and Automation, pp.895-900, 1996.
DOI : 10.1109/ROBOT.1996.503886

]. T. Chan and L. A. Vese, Active contours without edges, IEEE Transactions on Image Processing, vol.10, issue.2, pp.266-277, 2001.
DOI : 10.1109/83.902291

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.2.1828

]. R. Chang, W. J. Wu, D. R. Chen, W. M. Chen, W. Shu et al., 3-D US frame positioning using speckle decorrelation and image registration, Ultrasound in Medicine & Biology, vol.29, issue.6, pp.801-812, 2003.
DOI : 10.1016/S0301-5629(03)00036-X

]. F. Chaumette-2004 and . Chaumette, Image Moments: A General and Useful Set of Features for Visual Servoing, IEEE Transactions on Robotics, vol.20, issue.4, pp.713-723, 2004.
DOI : 10.1109/TRO.2004.829463

]. F. Chaumette and S. Hutchinson, Visual servo control. I. Basic approaches, IEEE Robotics & Automation Magazine, vol.13, issue.4, pp.82-90, 2006.
DOI : 10.1109/MRA.2006.250573

URL : https://hal.archives-ouvertes.fr/inria-00350638

]. F. Chaumette and S. Hutchinson, Visual servo control. II. Advanced approaches [Tutorial], IEEE Robotics & Automation Magazine, vol.14, issue.1, pp.109-118, 2007.
DOI : 10.1109/MRA.2007.339609

URL : https://hal.archives-ouvertes.fr/inria-00350638

]. W. Chimiak, R. O. Rainer, N. T. Wolfman, and W. Covitz, Architecture for a high-performance tele-ultrasound system, Medical imaging : PACS design and evaluation : Engineering and clinical issues, pp.459-465, 1996.

]. D. Clarke, C. Mohtadi, and P. S. Tuffs, Generalized predictive control???Part I. The basic algorithm, Automatica, vol.23, issue.2, pp.137-160, 1987.
DOI : 10.1016/0005-1098(87)90087-2

]. L. Cohen, On active contour models and balloons, CVGIP: Image Understanding, vol.53, issue.2, pp.211-218, 1991.
DOI : 10.1016/1049-9660(91)90028-N

]. L. Cohen and I. Cohen, Finite-element methods for active contour models and balloons for 2-D and 3-D images, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.15, issue.11, pp.1131-1147, 1993.
DOI : 10.1109/34.244675

]. C. Collewet and F. Chaumette, A contour approach for image-based control on objects with complex shape, Proceedings. 2000 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2000) (Cat. No.00CH37113), pp.751-756, 2000.
DOI : 10.1109/IROS.2000.894694

]. C. Collewet, Polar snakes: A fast and robust parametric active contour model, 2009 16th IEEE International Conference on Image Processing (ICIP), pp.3013-3016, 2009.
DOI : 10.1109/ICIP.2009.5414444

URL : https://hal.archives-ouvertes.fr/inria-00629794

]. C. Collewet and E. Marchand, Photometric Visual Servoing, IEEE Transactions on Robotics, vol.27, issue.4, pp.828-834, 2011.
DOI : 10.1109/TRO.2011.2112593

URL : https://hal.archives-ouvertes.fr/inria-00319107

]. A. Comport, E. Marchand, M. Pressigout, and F. Chaumette, Real-time markerless tracking for augmented reality: the virtual visual servoing framework, IEEE Transactions on Visualization and Computer Graphics, vol.12, issue.4, pp.615-628, 2006.
DOI : 10.1109/TVCG.2006.78

URL : https://hal.archives-ouvertes.fr/inria-00161250

]. A. Crétual and F. Chaumette, Visual Servoing Based on Image Motion, The International Journal of Robotics Research, vol.20, issue.11, pp.857-877, 2001.
DOI : 10.1177/02783640122068155

C. Delgorge, F. Courreges, L. A. Bassit, C. Novales, C. Rosenberger et al., A Tele-Operated Mobile Ultrasound Scanner Using a Light-Weight Robot, IEEE Transactions on Information Technology in Biomedicine, vol.9, issue.1, pp.50-58, 2005.
DOI : 10.1109/TITB.2004.840062

F. Daniel, L. S. Dementhon, and . Davis, Model-based object pose in 25 lines of code, International Journal of Computer Vision, vol.15, pp.123-141, 1995.

]. P. Detmer-1994, G. Detmer, T. Basheim, K. W. Hodges, E. P. Beach et al., 3d ultrasonic image feature localization based on magnetic scanhead tracking: In vitro calibration and validation, Ultrasound in Medicine & Biology, vol.20, issue.9, pp.923-936, 1994.
DOI : 10.1016/0301-5629(94)90052-3

]. T. Drummond and R. Cipolla, Real-time visual tracking of complex structures, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.24, issue.7, pp.932-946, 2002.
DOI : 10.1109/TPAMI.2002.1017620

]. B. Espiau, F. Chaumette, and P. Rives, A new approach to visual servoing in robotics, IEEE Transactions on Robotics and Automation, vol.8, issue.3, pp.313-326, 1992.
DOI : 10.1109/70.143350

]. N. Felix, D. Voisin, O. Clade, and R. Dufait, Biplane ultrasound arrays with integrated multiplexing solution for enhanced diagnostic accuracy in endorectal and transvaginal imaging, IEEE Ultrasonics Symposium, 2005., p.27, 2005.
DOI : 10.1109/ULTSYM.2005.1603332

]. A. Fonte, T. Essomba, P. Vieyres, J. Canou, S. P. Fraisse et al., Robotic Platform for an Interactive Tele-echographic System : The PROSIT ANR-2008 project, Hamlyn Symposium on Medical robotics, 1976.
URL : https://hal.archives-ouvertes.fr/hal-00751827

]. H. Freeman and L. S. Davis, A Corner-Finding Algorithm for Chain-Coded Curves, IEEE Transactions on Computers, vol.26, issue.3, pp.297-303, 1977.
DOI : 10.1109/TC.1977.1674825

]. J. Gangloff, Asservissements visuels rapides d'un robot manipulateur à 6 degrés de liberté, p.30, 1999.

]. J. Gangloff and M. De-mathelin, High speed visual servoing of a 6 DOF manipulator using multivariable predictive control Advanced Robotics, Special issue : advanced 3D vision and its application to robotics, p.30, 2003.

]. J. Gangloff, R. Ginhoux, M. De-mathelin, L. Soler, and J. Marescaux, Model predictive control for compensation of cyclic organ motions in teleoperated laparoscopic surgery, IEEE Transactions on Control Systems Technology, vol.14, issue.2, pp.235-246, 2006.
DOI : 10.1109/TCST.2005.863650

]. A. Gee, R. J. Housden, P. Hassenpflug, G. M. Treece, and R. W. Prager, Sensorless freehand 3D ultrasound in real tissue: Speckle decorrelation without fully developed speckle, Medical Image Analysis, vol.10, issue.2, pp.137-149, 2006.
DOI : 10.1016/j.media.2005.08.001

R. Ginhoux, J. Gangloff, M. De-mathelin, L. Soler, M. Sanchez et al., Beating heart tracking in robotic surgery using 500 Hz visual servoing, model predictive control and an adaptive observer, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004, pp.274-279, 2004.
DOI : 10.1109/ROBOT.2004.1307163

]. D. Glozman and M. Shoham, Flexible Needle Steering and Optimal Trajectory Planning for Percutaneous Therapies, Int. Conf. on Medical Image Computing and Computer Assisted Intervention, MICCAI'04, 2004.
DOI : 10.1007/978-3-540-30136-3_18

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.626.8196

]. G. Guthart-2000, J. K. Guthart, and . Salisbury, The Intuitive telesurgery system : Overview and application, IEEE Int. Conf. on Robotics and Automation, pp.618-621, 2000.

]. M. Hadwiger, J. M. Kniss, C. Rezk-salama, D. Weiskopf, and K. Engel, Realtime volume graphics, p.96, 2006.

]. G. Hager and P. N. Belhumeur, Efficient region tracking with parametric models of geometry and illumination, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.20, issue.10, pp.1025-1039, 1998.
DOI : 10.1109/34.722606

]. J. Hong, T. Dohi, M. Hashizume, K. Konishi, N. W. Hata-]-p et al., An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy, Physics in Medicine and Biology, vol.49, issue.3, pp.441-455, 2004.
DOI : 10.1088/0031-9155/49/3/007

M. K. Hu, Visual pattern recognition by moment invariants, IRE Trans. Information Theory, vol.8, pp.179-187, 1962.

]. N. Hungr, J. Troccaz, N. Zemiti, and N. Tripodi, Design of an ultrasound-guided robotic brachytherapy needle-insertion system, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp.250-253, 2009.
DOI : 10.1109/IEMBS.2009.5333801

URL : https://hal.archives-ouvertes.fr/hal-00416163

]. S. Impedovo, B. Marangelli, and A. M. Fanelli, A fourier descriptor set for recognizing nonstylized numerals, IEEE Tran. on Systems, Man and Cybernetics, vol.8, issue.69, pp.640-645, 1978.

M. Kass, A. Witkin, D. Terzopoulos-]-o, F. Kermorgant, and . Chaumette, Snakes: Active contour models, IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, pp.321-331, 1987.
DOI : 10.1007/BF00133570

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.124.5318

]. A. Krupa, Commande par vision d'un robot de chirurgie laparoscopique, 2003.

]. A. Krupa, J. Gangloff, M. Doignon, G. De-mathelin, J. Morel et al., Autonomous 3-d positioning of surgical instruments in robotized laparoscopic surgery using visual servoing, IEEE Transactions on Robotics and Automation, vol.19, issue.5, pp.842-853, 2003.
DOI : 10.1109/TRA.2003.817086

]. A. Krupa and F. Chaumette, Control of an ultrasound probe by adaptive visual servoing, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.2007-2012, 2005.
DOI : 10.1109/IROS.2005.1545272

URL : https://hal.archives-ouvertes.fr/inria-00351891

]. A. Krupa, Automatic calibration of a robotized 3D ultrasound imaging system by visual servoing, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006., pp.4136-4141, 2006.
DOI : 10.1109/ROBOT.2006.1642338

URL : https://hal.archives-ouvertes.fr/inria-00350295

]. A. Krupa and F. Chaumette, Guidance of an ultrasound probe by visual servoing, Advanced Robotics, vol.20, issue.11, pp.1203-1218, 2006.
DOI : 10.1163/156855306778792443

URL : https://hal.archives-ouvertes.fr/inria-00350296

]. A. Krupa, G. Fichtinger, and G. Hager, Full Motion Tracking in Ultrasound Using Image Speckle Information and Visual Servoing, Proceedings 2007 IEEE International Conference on Robotics and Automation, pp.2458-2464, 2007.
DOI : 10.1109/ROBOT.2007.363688

URL : https://hal.archives-ouvertes.fr/inria-00350650

]. A. Krupa, G. Fichtinger, G. D. Hager, and ]. Krupa, Real-time tissue tracking with B-mode ultrasound using speckle and visual servoing In Int. Conf. on Medical Image Computing and Computer-Assisted Intervention, MICCAI'07 Asservissement visuel par imagerie médicale, Journées Nationales de la Recherche en Robotique, JNRR'09, pp.1-8, 2007.

]. A. Krupa, G. Fichtinger, and G. D. Hager, Real-time Motion Stabilization with B-mode Ultrasound Using Image Speckle Information and Visual Servoing, The International Journal of Robotics Research, vol.26, issue.4, pp.1334-1354, 2009.
DOI : 10.1177/0278364909104066

URL : https://hal.archives-ouvertes.fr/inria-00436745

]. C. Laporte and T. Arbel, Probabilistic Speckle Decorrelation for 3D Ultrasound, Int. Conf. on Medical Image Computing and Computer-Assisted Intervention, MIC- CAI'07, pp.925-932, 2007.
DOI : 10.1007/978-3-540-75757-3_112

]. C. Lawrence, J. L. Zhou, and A. L. Tits, User's Guide for CFSQP Version 2.5 : A C code for solving (large Scale) constrained nonlinear (minimax) optimization problems, generating iterates satisfying all inequality constraints, p.43, 1997.

D. Lee, N. Koizumi, K. Ota, S. Yoshizawa, A. Ito et al., Ultrasound-based visual servoing system for lithotripsy, IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, IROS'07, pp.877-882, 2007.

]. D. Lee and A. Krupa, Intensity-based visual servoing for non-rigid motion compensation of soft tissue structures due to physiological motion using 4D ultrasound, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.2831-2836, 2011.
DOI : 10.1109/IROS.2011.6094953

URL : https://hal.archives-ouvertes.fr/hal-00639687

]. T. Li, A. Krupa, and C. Collewet, A robust parametric active contour based on fourier descriptors, 2011 18th IEEE International Conference on Image Processing, p.71, 2011.
DOI : 10.1109/ICIP.2011.6115601

URL : https://hal.archives-ouvertes.fr/hal-00645326

]. T. Li, A. Krupa, and C. Collewet, Un contour actif robuste basé sur les descripteurs de Fourier, ORASIS'11, journées francophones des jeunes chercheurs en vision par ordinateur, p.74, 2011.

]. T. Li, Commande d'un robot de télé-échographie par asservissement visuel, p.15, 2012.

]. T. Li, O. Kermorgant, and A. Krupa, Maintaining visibility constraints during teleechography with ultrasound visual servoing, IEEE Int. Conf. on Robotics and Automation , ICRA'12, p.79, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00748987

]. W. Lie and Y. C. Chen, Shape representation and matching using polar signature, Proc. Int. Computer Symposium, pp.710-718, 1986.

]. Y. Liu, T. S. Huang, and O. D. Faugeras, Determination of camera location from 2-D to 3-D line and point correspondences, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.12, issue.1, pp.28-37, 1990.
DOI : 10.1109/34.41381

]. D. Lowe, Fitting parameterized three-dimensional models to images, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.13, issue.5, pp.441-450, 1936.
DOI : 10.1109/34.134043

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.3.7868

]. M. Lubinski, S. Y. Emelianov, and M. O. Donnell, Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.46, issue.1, pp.82-96, 1999.
DOI : 10.1109/58.741427

]. J. Maintz and M. A. Viergever, A survey of medical image registration, Medical Image Analysis, vol.2, issue.1, pp.1-36, 1998.
DOI : 10.1016/S1361-8415(01)80026-8

]. E. Malis, F. Chaumette, and S. Boudet, 2 1/2 D visual servoing, IEEE Transactions on Robotics and Automation, vol.15, issue.2, pp.238-250, 1999.
DOI : 10.1109/70.760345

URL : https://hal.archives-ouvertes.fr/inria-00073302

]. E. Malis and F. Chaumette, Theoretical improvements in the stability analysis of a new class of model-free visual servoing methods, IEEE Transactions on Robotics and Automation, vol.18, issue.2, pp.176-186, 2002.
DOI : 10.1109/TRA.2002.999646

URL : https://hal.archives-ouvertes.fr/inria-00352094

]. R. Malladi, J. A. Sethian, and B. C. Vemuri, Shape modeling with front propagation: a level set approach, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.17, issue.2, pp.158-175, 1995.
DOI : 10.1109/34.368173

]. N. Mansard, O. Khatib, and A. Kheddar, A Unified Approach to Integrate Unilateral Constraints in the Stack of Tasks, IEEE Transactions on Robotics, vol.25, issue.3, pp.670-685, 2009.
DOI : 10.1109/TRO.2009.2020345

URL : https://hal.archives-ouvertes.fr/lirmm-00798676

]. N. Mansard, A. Remazeilles, and F. Chaumette, Continuity of Varying-Feature-Set Control Laws, IEEE Transactions on Automatic Control, vol.54, issue.11, pp.2493-2505, 2009.
DOI : 10.1109/TAC.2009.2031202

URL : https://hal.archives-ouvertes.fr/hal-01062003

]. E. Marchand and F. Chaumette, Virtual Visual Servoing: a framework for real-time augmented reality, Computer Graphics Forum, vol.1, issue.3, pp.289-298, 2002.
DOI : 10.1111/1467-8659.t01-1-00588

URL : https://hal.archives-ouvertes.fr/inria-00352096

]. P. Martinet, J. Gallice, and D. Khadraoui, Vision based control law using 3D visual features, World Automation Congress, WAC'96, Robotics and Manufacturing Systems, pp.497-502, 1935.

]. K. Masuda, E. Kimura, N. Tateishi, and K. Ishihara, Three dimensional motion mechanism of ultrasound probe and its application for tele-echography system, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180), pp.1112-1116, 2001.
DOI : 10.1109/IROS.2001.976317

]. B. Maurin, B. Bayle, O. Piccin, J. Gangloff, M. De-mathelin et al., A Patient-Mounted Robotic Platform for CT-Scan Guided Procedures, IEEE Transactions on Biomedical Engineering, vol.55, issue.10, pp.2417-2425, 2005.
DOI : 10.1109/TBME.2008.919882

]. R. Mebarki, A. Krupa, and F. Chaumette, Image moments-based ultrasound visual servoing, 2008 IEEE International Conference on Robotics and Automation, pp.113-119, 2008.
DOI : 10.1109/ROBOT.2008.4543195

URL : https://hal.archives-ouvertes.fr/inria-00351872

]. R. Mebarki, A. Krupa, and C. Collewet, Automatic Guidance of an Ultrasound Probe by Visual Servoing Based on B-Mode Image Moments, Int. Conf. on Medical Image Computing and Computer-Assisted Intervention, MICCAI'08, pp.339-346, 2008.
DOI : 10.1007/978-3-540-85990-1_41

URL : https://hal.archives-ouvertes.fr/inria-00351873

]. R. Mebarki, A. Krupa, and F. Chaumette, Modeling and 3D local estimation for in-plane and out-of-plane motion guidance by 2D ultrasound-based visual servoing, 2009 IEEE International Conference on Robotics and Automation, pp.319-325, 2009.
DOI : 10.1109/ROBOT.2009.5152371

URL : https://hal.archives-ouvertes.fr/inria-00436757

]. R. Mebarki, Automatic guidance of robotized 2D ultrasound probes with visual servoing based on image moments, p.60, 2010.
URL : https://hal.archives-ouvertes.fr/tel-00476718

]. R. Mebarki, A. Krupa, and F. Chaumette, 2-D Ultrasound Probe Complete Guidance by Visual Servoing Using Image Moments, IEEE Transactions on Robotics, vol.26, issue.2, pp.296-306, 2010.
DOI : 10.1109/TRO.2010.2042533

URL : https://hal.archives-ouvertes.fr/inria-00544791

]. M. Bibliographie, A. Mitsuishi, N. Morita, S. Sugita, R. Sora et al., Master-slave robotic platform and its feasibility study for micro-neurosurgery Moment functions in image analysis : Theory and application A multi-plane approach for ultrasound visual servoing : application to a registration task, IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, IROS'10, pp.55-5706, 1998.

]. C. Nadeau, C. Nadeau, and A. Krupa, Asservissement visuel échographique Asservissement visuel direct d'une sonde échographique Improving ultrasound intensity-based visual servoing : tracking and positioning tasks with 2D and bi-plane probes, Recherche en Imagerie et Technologies pour la Santé IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, pp.101-93, 2011.

]. C. Nadeau and A. Krupa, Intensity-based direct visual servoing of an ultrasound probe, 2011 IEEE International Conference on Robotics and Automation, pp.5677-5682, 2011.
DOI : 10.1109/ICRA.2011.5979673

URL : https://hal.archives-ouvertes.fr/hal-00639689

]. C. Nadeau, A. Krupa, J. Gangloff-nadeau, H. Ren, A. Krupa et al., Automatic tracking of an organ section with an ultrasound probe : Compensation of respiratory motion In Int. Conf. on Medical Image Computing and Computer Assisted Intervention Target tracking in 3D ultrasound volumes by direct visual servoing, Hamlyn Symposium on Medical robotics, pp.57-64, 0105.

]. R. Nakadate, J. Solis, A. Takanashi, E. Minagawa, M. Sugawara et al., Out-of-plane visual servoing method for tracking the carotid artery with a robotassisted ultrasound diagnostic system Heartbeat synchronization for robotic cardiac surgery, IEEE Int. Conf. on Robotics and Automation IEEE Int. Conf. on Robotics and Automation, pp.2014-2019, 2001.

]. T. Nelson and D. H. Pretorius, Three-dimensional ultrasound imaging, Ultrasound in Medicine & Biology, vol.24, issue.9, pp.1243-1270, 1998.
DOI : 10.1016/S0301-5629(98)00043-X

]. Z. Neubach and M. Shoham, Ultrasound-Guided Robot for Flexible Needle Steering, IEEE Transactions on Biomedical Engineering, vol.57, issue.4, pp.799-805, 2010.
DOI : 10.1109/TBME.2009.2030169

]. L. Nouaille, N. Smith-guerin, G. Poisson, P. Arbeille, ]. P. Novotny et al., Optimization of a 4 dof tele-echography robot Real-Time visual servoing of a robot using three-dimensional ultrasound, IEEE/RSJ Int. Conf. on Intelligent Robots and Systems IEEE Int. Conf. on Robotics and Automation, ICRA'07, pp.3501-3506, 2007.

]. T. Ortmaier, M. A. Vitrani, and G. Morel, Robust Real-Time Instrument Tracking in Ultrasound Images for Visual Servoing, Proceedings of the 2005 IEEE International Conference on Robotics and Automation, pp.2179-2184, 2005.
DOI : 10.1109/ROBOT.2005.1570434

URL : https://hal.archives-ouvertes.fr/hal-01171255

]. B. Itkowitz, E. Butler, P. Dupont, and J. Lock, Design and control of concentrictube robots, IEEE Trans. on Robotics, vol.26, issue.2, pp.209-225, 2010.

N. Pagoulatos, W. Edwards, D. R. Haynor, and Y. Kim, Interactive 3D registration of ultrasound and magnetic resonance images based on a magnetic position sensor, IEEE Transactions on Information Technology in Biomedicine, vol.3, issue.4, pp.278-288, 1999.
DOI : 10.1109/4233.809172

N. Pagoulatos, R. N. Rohling, W. S. Edwards, and Y. Kim, <title>New spatial localizer based on fiber optics with applications in 3D ultrasound imaging</title>, Medical Imaging 2000: Image Display and Visualization, pp.595-602, 2000.
DOI : 10.1117/12.383088

]. N. Papanikolopoulos, P. K. Khosla, and T. Kanade, Visual tracking of a moving target by a camera mounted on a robot: a combination of control and vision, IEEE Transactions on Robotics and Automation, vol.9, issue.1, pp.14-35, 1993.
DOI : 10.1109/70.210792

F. Pierrot, E. Dombre, E. Degoulange, L. Urbain, P. Caron et al., Hippocrate: a safe robot arm for medical applications with force feedback, Medical Image Analysis, vol.3, issue.3, pp.285-300, 1999.
DOI : 10.1016/S1361-8415(99)80025-5

]. J. Pluim, J. B. Maintz, and M. A. Viergever, Mutual-information-based registration of medical images: a survey, IEEE Transactions on Medical Imaging, vol.22, issue.8, pp.986-1004, 2003.
DOI : 10.1109/TMI.2003.815867

]. R. Prager, A. H. Gee, and L. Berman, Stradx: real-time acquisition and visualization of freehand three-dimensional ultrasound, Medical Image Analysis, vol.3, issue.2, pp.129-140, 1999.
DOI : 10.1016/S1361-8415(99)80003-6

F. Precioso, M. Barlaud, T. Blu, and M. Unser, Robust real-time segmentation of images and videos using a smooth-spline snake-based algorithm, IEEE Transactions on Image Processing, vol.14, issue.7, pp.910-924, 2005.
DOI : 10.1109/TIP.2005.849307

URL : https://hal.archives-ouvertes.fr/hal-01343201

]. J. Prokop and A. P. Reeves, A survey of moment-based techniques for unoccluded object representation and recognition, CVGIP : Graphical Models and Image Processing, pp.438-460, 1992.
DOI : 10.1016/1049-9652(92)90027-U

]. J. Revell, M. Mirmehdi, and D. Mcnally, Computer vision elastography: speckle adaptive motion estimation for elastography using ultrasound sequences, IEEE Transactions on Medical Imaging, vol.24, issue.6, pp.755-766, 2005.
DOI : 10.1109/TMI.2005.848331

]. R. Richa, P. Poignet, and C. Liu, Three-dimensional Motion Tracking for Beating Heart Surgery Using a Thin-plate Spline Deformable Model, The International Journal of Robotics Research, vol.22, issue.11, pp.218-230, 2009.
DOI : 10.1177/0278364909356600

]. R. Rohling, 3D freehand ultrasound : reconstruction and spatial compounding, p.28, 1998.

]. F. Rousseau, P. Hellier, and C. Barillot, Confhusius: A robust and fully automatic calibration method for 3D freehand ultrasound, Medical Image Analysis, vol.9, issue.1, pp.25-38, 2005.
DOI : 10.1016/j.media.2004.06.021

URL : https://hal.archives-ouvertes.fr/inserm-00136520

]. S. Salcudean, W. H. Zhu, P. Abolmaesumi, S. Bachmann, and P. D. Lawrence, A Robot System for Medical Ultrasound, 9th International Symposium of Robotics Research (ISRR'99), Snowbird, pp.152-159, 1999.
DOI : 10.1109/42.41487

]. C. Samson, B. Espiau, and M. L. Borgne, Robot control : The task function approach, p.80, 1991.

]. M. Sauvée, P. Poignet, and E. Dombre, Ultrasound Image-Based Visual Servoing of a Surgical Instrument Through Nonlinear Model Predictive Control, The International Journal of Robotics Research, vol.127, issue.6, pp.25-40, 2008.
DOI : 10.1177/0278364907082269

]. G. Slabaugh, G. Unal, T. Fang, and M. Wels, Ultrasound-Specific Segmentation via Decorrelation and Statistical Region-Based Active Contours, 2006 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, Volume 1 (CVPR'06), pp.45-53, 2006.
DOI : 10.1109/CVPR.2006.318

URL : http://openaccess.city.ac.uk/6079/1/Ultrasound%20specific.pdf

]. J. Stoll, P. M. Novotny, R. D. Howe, and P. E. Dupont, Real-time 3D ultrasoundbased servoing of a surgical instrument, IEEE Int. Conf. on Robotics and Automation , ICRA'06, p.43, 2006.

]. M. Subasic, S. Loncaric, and E. Sorantin, Region-based deformable model for aortic wall segmentation, 3rd International Symposium on Image and Signal Processing and Analysis, 2003. ISPA 2003. Proceedings of the, pp.731-735, 2003.
DOI : 10.1109/ISPA.2003.1296372

]. O. Tahri and F. Chaumette, Point-based and region-based image moments for visual servoing of planar objects, IEEE Transactions on Robotics, vol.21, issue.6, pp.1116-1127, 2005.
DOI : 10.1109/TRO.2005.853500

URL : https://hal.archives-ouvertes.fr/inria-00351908

]. R. Taylor, B. D. Mittelstadt, H. A. Paul, W. Hanson, P. Kazanzides et al., An image-directed robotic system for precise orthopaedic surgery, IEEE Transactions on Robotics and Automation, vol.10, issue.3, pp.261-275, 1994.
DOI : 10.1109/70.294202

]. D. Uecker, C. Lee, Y. F. Wang, and Y. Wang, Automated instrument tracking in robotically assisted laparoscopic surgery, Journal of Image Guided Surgery, vol.1, issue.6, pp.308-325, 1995.
DOI : 10.1002/(SICI)1522-712X(1995)1:6<308::AID-IGS3>3.0.CO;2-E

]. A. Vilchis, J. Troccaz, P. Cinquin, K. Masuda, and F. Pellissier, A new robot architecture for tele-echography, IEEE Transactions on Robotics and Automation, vol.19, issue.5, pp.922-926, 2003.
DOI : 10.1109/TRA.2003.817509

]. M. Vitrani, G. Morel, and T. Ortmaier, Automatic Guidance of a Surgical Instrument with Ultrasound Based Visual Servoing, Proceedings of the 2005 IEEE International Conference on Robotics and Automation, pp.508-513, 2005.
DOI : 10.1109/ROBOT.2005.1570169

URL : https://hal.archives-ouvertes.fr/hal-01170707

M. A. Vitrani, H. Mitterhofer, G. Morel, and N. Bonnet, Robust Ultrasound-Based Visual Servoing for Beating Heart Intracardiac Surgery, Proceedings 2007 IEEE International Conference on Robotics and Automation, pp.3021-3027, 2007.
DOI : 10.1109/ROBOT.2007.363931

URL : https://hal.archives-ouvertes.fr/hal-01170711

]. M. Vitrani and G. Morel, Hand-eye self-calibration of an ultrasound imagebased robotic system, IEEE/RSJ IROS'08 International Conference on Intelligent Robots and Systems, pp.1179-1185, 2008.
URL : https://hal.archives-ouvertes.fr/hal-01170721

]. G. Wei, K. Arbter, and G. Hirzinger, Real-time visual servoing for laparoscopic surgery, IEEE Trans. in Engineering in Medecine and Biology, vol.16, issue.1, pp.40-45, 1997.

]. W. Wilson, C. Hulls, and G. Bell, Relative end-effector control using Cartesian position based visual servoing, IEEE Transactions on Robotics and Automation, vol.12, issue.5, pp.684-696, 1996.
DOI : 10.1109/70.538974

]. M. Wyawahare, P. M. Patil, and H. K. Abhyankar, Image registration techniques : An overview, Int. Journal of Signal Processing Image Processing and Pattern Recognition, vol.2, issue.3, pp.11-28, 2009.

]. C. Xu and L. Prince, Generalized gradient vector flow external forces for active contours, Signal Processing, vol.71, issue.2, pp.131-139, 1998.
DOI : 10.1016/S0165-1684(98)00140-6

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.35.5052