D. Peiffert, Curieth??rapie interstitielle des cancers localis??s de prostate par implants permanents d'iode 125, Cancer/Radioth??rapie, vol.9, issue.6-7, p.388, 2005.
DOI : 10.1016/j.canrad.2005.09.008

R. G. Stock, N. N. Stone, and M. F. Wesson, A modified technique allowing interactive ultrasound-guided three-dimensional transperineal prostate implantation, International Journal of Radiation Oncology*Biology*Physics, vol.32, issue.1, p.219, 1995.
DOI : 10.1016/0360-3016(95)00521-Y

R. G. Stock, N. N. Stone, and J. Kao, The effect of disease and treatment-related factors on biopsy results after prostate brachytherapy, Cancer, vol.41, issue.8, p.1829, 2000.
DOI : 10.1002/1097-0142(20001015)89:8<1829::AID-CNCR25>3.0.CO;2-9

R. G. Stock, N. N. Stone, and A. Tabert, A dose-response study for I-125

C. Buron, L. Vu, B. Cosset, and J. M. , Brachytherapy versus prostatectomy in localized prostate cancer: Results of a French multicenter prospective medico-economic study, International Journal of Radiation Oncology*Biology*Physics, vol.67, issue.3, p.812, 2007.
DOI : 10.1016/j.ijrobp.2006.10.011

P. Pommier, A. Villers, and A. Bataillard, [Standards, Options, and Recommendations for brachytherapy in patients with prostate cancer: efficacy and toxicity], Cancer Radiother, vol.5, p.770, 2001.

L. Potters, Y. Cao, and E. Calugaru, A comprehensive review of CT-based dosimetry parameters and biochemical control in patients treated with permanent prostate brachytherapy, International Journal of Radiation Oncology*Biology*Physics, vol.50, issue.3, p.605, 2001.
DOI : 10.1016/S0360-3016(01)01473-0

H. Tanaka, S. Hayashi, and K. Ohtakara, Usefulness of CT-MRI Fusion in Radiotherapy Planning for Localized Prostate Cancer, Journal of Radiation Research, vol.52, issue.6, p.782, 2011.
DOI : 10.1269/jrr.11053

P. D. Grimm, J. C. Blasko, and J. E. Sylvester, 10-year biochemical (prostate-specific antigen) control of prostate cancer with 125I brachytherapy, International Journal of Radiation Oncology*Biology*Physics, vol.51, issue.1, p.31, 2001.
DOI : 10.1016/S0360-3016(01)01601-7

H. Ragde, A. A. Elgamal, and P. B. Snow, Ten-Year Disease Free Survival After Transperineal Sonography-Guided Iodine-125 Brachytherapy With or Without 45-Gray External Beam Irradiation in the Treatment of Patients With Clinically Localized, Low to High Gleason Grade Prostate Carcinoma, The Journal of Urology, vol.161, issue.1, p.989, 199811.
DOI : 10.1016/S0022-5347(01)62157-8

K. Wallner, J. Roy, and L. Harrison, Rate Brachytherapy for Patients with Localised Prostate Cancer: A Systematic Review of Randomised and Nonrandomised Controlled Clinical Trials Tumor control and morbidity following transperineal iodine 125 implantation for stage T1/T2 prostatic carcinoma, Eur Urol J Clin Oncol, vol.60, issue.14, pp.881-449, 1996.

B. L. Dalkin, B. A. Christopher, D. L. Shawler, T. Torre, and P. A. Fearn, single-surgeon studies Potency after permanent prostate brachytherapy for localized prostate cancer Penile erectile function after permanent radioactive seed implantation for treatment of prostate cancer Erectile function after permanent prostate brachytherapy [The recommendations of the International Commission on Radiological Protection (ICRP) for high-dose-rate brachytherapy and for permanent prostatic implants] Overcoming pubic arch interference with free-hand needle placement in men undergoing prostate brachytherapy Intra-operative pubic arch interference during prostate seed brachytherapy in patients with CT-based pubic arch interference of < or =1cm Use of pelvic CT scanning to evaluate pubic arch interference of transperineal prostate brachytherapyABS) recommendations for transperineal permanent brachytherapy of prostate cancer, A discrete soft tissue model for complex anatomical environment simulations. Stud Health Technol Inform, pp.28-1235, 2002.

A. R. Padhani, V. S. Khoo, and J. Suckling, Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI, International Journal of Radiation Oncology*Biology*Physics, vol.44, issue.3, pp.525-568, 2002.
DOI : 10.1016/S0360-3016(99)00040-1

E. Melian, G. S. Mageras, and Z. Fuks, Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning, International Journal of Radiation Oncology*Biology*Physics, vol.38, issue.1, pp.73-856, 1902.
DOI : 10.1016/S0360-3016(97)00221-6

S. E. Schild, H. E. Casale, L. P. Bellefontaine, A. Bruce, and A. P. Kroes, Movements of the Prostate Due to Rectal and Bladder Distension: Implications for Radiotherapy, Medical Dosimetry, vol.18, issue.1, p.13, 199329.
DOI : 10.1016/0958-3947(93)90021-K

J. C. Roeske, J. D. Forman, and C. F. Mesina, Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy, International Journal of Radiation Oncology*Biology*Physics, vol.33, issue.5, pp.1321-1352, 1995.
DOI : 10.1016/0360-3016(95)00225-1

J. A. Antolak, . Rosen, . Ii, and C. H. Childress, Prostate target volume variations during a course of radiotherapy Documentary of inter and intra-fractionnal prostate motion using self-moving CT scanner combined with linear accelerator and cine MRI Online ultrasound image guidance for radiotherapy of prostate cancer: impact of image acquisition on prostate displacement Prostate localization using transabdominal ultrasound imaging, Int J Radiat Oncol Biol Phys International Journal of Radiation Oncology Biology Physics Int J Radiat Oncol Biol Phys Int J Radiat Oncol Biol Phys, vol.42, issue.56, pp.661-706, 2002.

J. Roy, N. Stone, S. Hong, Y. Lo, and R. Stock, Prostate gland motion, deformation and distortion during needle placement in patients undergoing permanent seed implantation: implications for pre-planning, International Journal of Radiation Oncology*Biology*Physics, vol.51, issue.3, p.322, 2001.
DOI : 10.1016/S0360-3016(01)02416-6

K. K. Yu, H. Hricak, A. Villers, P. Puech, and D. Mouton, Imaging prostate cancer Dynamic contrast enhanced, pelvic phased array magnetic resonance imaging of localized prostate cancer for predicting tumor volume: correlation with radical prostatectomy findings Three-Tesla Magnetic Resonance-Guided Prostate Biopsy in Men With Increased Prostate-Specific Antigen and Repeated, Negative, Random, Systematic, Transrectal Ultrasound Biopsies: Detection of Clinically Significant Prostate Cancers Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer Transperineal magnetic resonance image guided prostate biopsy MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results, et al.: System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results. Radiology, pp.59-2432, 1998.

F. Lakosi, G. Antal, and C. Vandulek, Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy: Feasibility and Initial Experiences Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy, Pathology & Oncology Research, vol.91, issue.1, p.315
DOI : 10.1007/s12253-010-9319-x

N. Makni, P. Puech, and P. Colin, Elastic image registration for guiding focal laser ablation of prostate cancer: Preliminary results 3-dimensional elastic registration system of prostate biopsy location by real-time 3-dimensional transrectal ultrasound guidance with magnetic resonance/transrectal ultrasound image fusion MRI/TRUS data fusion for prostate brachytherapy. Preliminary results, Y. et al.: MRI/TRUS data fusion for brachytherapy, pp.1568-256, 2006.

S. Xu, J. Kruecker, and B. Turkbey, Real-time MRI-TRUS fusion for guidance of targeted prostate biopsies, Computer Aided Surgery, vol.13, issue.5, pp.255-334, 200851.
DOI : 10.1007/978-3-540-75759-7_4

L. Phee, G. Fichtinger, E. C. Burdette, and A. Tanacs, ULTRASOUND GUIDED ROBOTIC BIOPSY OF THE PROSTATE, International Journal of Humanoid Robotics, vol.03, issue.04, pp.463-746, 2005.
DOI : 10.1142/S0219843606000850

Z. Wei, G. Wan, and L. Gardi, 3D TRUS Guided Robot Assisted Prostate Brachytherapy, Med Phys Med Image Anal Brachytherapy, vol.31, issue.10, pp.539-535, 2008.
DOI : 10.1007/11566489_3

Y. Yu, T. K. Podder, and Y. D. Zhang, Robotic system for prostate brachytherapy, Proceedings of the IEEE International Conference on Robotics and Automation, pp.366-96, 2008.
DOI : 10.1118/1.2218061

M. A. Meltsner, N. J. Ferrier, B. R. Thomadsen, J. Kettenbach, G. Kronreif et al., Observations on rotating needle insertions using a brachytherapy robot, Proceedings of the 29th annual international conference of the IEEE Ennginering in medicine and biology society: 1233, pp.6027-765, 2005.
DOI : 10.1088/0031-9155/52/19/021

D. Stoianovici, D. Song, and D. Petrisor, ???MRI Stealth??? robot for prostate interventions, Minimally Invasive Therapy & Allied Technologies, vol.50, issue.1, p.241, 2007.
DOI : 10.1080/13645700701520735

K. Masamune, E. Kobayashi, and Y. Masutani, Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery, Journal of Image Guided Surgery, vol.1, issue.4, p.242, 1995.
DOI : 10.1002/(SICI)1522-712X(1995)1:4<242::AID-IGS7>3.0.CO;2-A

A. Felden, J. Vagner, and A. Hinz, ROBITOM- ROBOT FOR BIOPSY AND THERAPY OF THE MAMMA, Biomedizinische Technik/Biomedical Engineering, vol.47, issue.s1a, 2002.
DOI : 10.1515/bmte.2002.47.s1a.2

E. Hempel, H. Fischer, and L. Gumb, An MRI-Compatible Surgical Robot for Precise Radiological Interventions, Computer Aided Surgery, vol.5, issue.4, p.180, 2003.
DOI : 10.1148/radiology.209.2.9807562

. Chinzei and H. Warfield, Planning, simulation and assistance with intraoperative MRI, Minimally Invasive Therapy & Allied Technologies, vol.28, issue.12, pp.59-74, 2007.
DOI : 10.1080/13645700310001531

A. Krieger, C. Csoma, . Iordachital, and . Ii, Design and Preliminary Accuracy Studies of an MRI-Guided Transrectal Prostate Intervention System, Med Image Comput Comput Assist Interv, vol.10, p.59, 2007.
DOI : 10.1007/978-3-540-75759-7_8

D. Stoianovici, A. Patriciu, and D. Petrisor, A New Type of Motor: Pneumatic Step Motor A MR compatible mechatronic system to facilitate magic angle experiments in vivo Light puncture robot for CT and MRI interventions: designing a new robotic architecture to perform abdominal and thoracic punctures, IEEE ASME Trans Mechatron Med Image Comput Comput Assist Interv IEEE Eng Med Biol Mag, vol.12, issue.27, pp.98-604, 2007.

A. Melzer, B. Gutmann, and T. Remmele, INNOMOTION for Percutaneous Image-Guided Interventions, IEEE Engineering in Medicine and Biology Magazine, vol.27, issue.3, p.66, 2008.
DOI : 10.1109/EMB.2007.910274

P. Mozer, M. Baumann, and G. Chevreau, [Image fusion: use in the control of the distribution of prostatic biopsies] Prostate biopsies guided by three-dimensional real-time (4-D) transrectal ultrasonography on a phantom: comparative study versus two-dimensional transrectal ultrasound-guided biopsies [Real-time threedimensional (4D) ultrasound-guided prostatic biopsies on a phantom Comparative study versus 2D guidance] Towards 3D ultrasound image based soft tissue tracking: a transrectal ultrasound prostate image alignment system, Prostate biopsy assistance system with gland deformation estimation for enhanced precision. Med Image Comput Comput Assist Interv, pp.15-1097, 2007.

M. Baumann, P. Mozer, and V. Daanen, Prostate biopsy tracking with deformation estimation, Medical Image Analysis, vol.16, issue.3, pp.562-2012
DOI : 10.1016/j.media.2011.01.008

URL : https://hal.archives-ouvertes.fr/hal-00606407

P. Mozer, M. Baumann, and G. Chevreau, Mapping of Transrectal Ultrasonographic Prostate Biopsies, Journal of Ultrasound in Medicine, vol.28, issue.4, pp.455-5766, 2005.
DOI : 10.7863/jum.2009.28.4.455

URL : https://hal.archives-ouvertes.fr/hal-00371744

S. Martin, J. Troccaz, V. Daanenc, R. Lefrancois, R. S. Sloboda et al., Automated segmentation of the prostate in 3D MR images using a probabilistic atlas and a spatially constrained deformable model A medical needle drive for the study of interstitial implant mechanics A velocity-dependent model for needle insertion in soft tissue, Med Phys Med Eng Phys Med Image Comput Comput Assist Interv Med Phys, vol.37, issue.35, pp.1579-255, 2008.

X. Wen, S. T. Salcudean, and P. D. Lawrence, Detection of Brachytherapy Seeds Using 3-D Transrectal Ultrasound, IEEE Transactions on Biomedical Engineering, vol.57, issue.10, p.2467, 2010.
DOI : 10.1109/TBME.2010.2053926

J. A. Cunha, I. C. Hsu, and J. Pouliot, Toward adaptive stereotactic robotic brachytherapy for prostate cancer: Demonstration of an adaptive workflow incorporating inverse planning and an MR stealth robot, Minimally Invasive Therapy & Allied Technologies, vol.247, issue.4, p.189, 2010.
DOI : 10.1016/j.radonc.2005.09.018

J. P. Mcgahan, J. Ryu, and M. Fogata, Ultrasound probe pressure as a source of error in prostate localization for external beam radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.60, issue.3, p.788, 2004.
DOI : 10.1016/j.ijrobp.2004.04.005

E. Dehghan, X. Wen, and R. Zahiri-azar, Modeling of needle-tissue interaction using ultrasound-based motion estimation Vivo motion and force measurement of surgical needle intervention during prostate brachytherapy, Med Image Comput Comput Assist Interv Med Phys, vol.10, issue.33, pp.709-96, 2006.

E. L. Madsen, M. A. Hobson, and H. Shi, Tissue-mimicking agar/gelatin materials for use in heterogeneous elastography phantoms Acoustical properties of selected tissue phantom materials for ultrasound imaging Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging, Phys Med Biol Phys Med Biol Phys Med Biol, vol.50, issue.49, pp.5597-475, 2004.

J. Fromageau, J. L. Gennisson, and C. Schmitt, Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.54, issue.3, p.498, 2007.
DOI : 10.1109/TUFFC.2007.273

G. M. Spirou, A. A. Oraevsky, and I. A. Vitkin, Optical and acoustic properties at 1064 nm of polyvinyl chloride-plastisol for use as a tissue phantom in biomedical optoacoustics, Physics in Medicine and Biology, vol.50, issue.14, p.141, 2005.
DOI : 10.1088/0031-9155/50/14/N01

D. Souza, W. D. Madsen, E. L. Unal, and O. , Tissue mimicking materials for a multi-imaging modality prostate phantom, Medical Physics, vol.11, issue.4, p.688, 2001.
DOI : 10.1118/1.1354998

B. W. Pogue and M. S. Patterson, Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry, Journal of Biomedical Optics, vol.11, issue.4, p.41102, 2006.
DOI : 10.1117/1.2335429

U. Lindner, N. Lawrentschuk, and R. A. Weersink, Construction and Evaluation of an Anatomically Correct Multi-Image Modality Compatible Phantom for Prostate Cancer Focal Ablation, The Journal of Urology, vol.184, issue.1, p.352, 2010.
DOI : 10.1016/j.juro.2010.03.001

M. Mcdonald, S. Lochhead, and R. Chopra, Multi-modality tissue-mimicking phantom for thermal therapy, Physics in Medicine and Biology, vol.49, issue.13, p.2767, 2004.
DOI : 10.1088/0031-9155/49/13/001

H. Kato, M. Kuroda, and K. Yoshimura, Composition of MRI phantom equivalent to human tissues, Medical Physics, vol.41, issue.10, p.3199, 2005.
DOI : 10.1088/0031-9155/41/11/003

N. Bittner, G. S. Merrick, and W. M. Butler, The correlation between annular treatment margins and biochemical failure in prostate brachytherapy patients with optimized intraprostatic dosimetry, Brachytherapy, vol.10, issue.5, p.409, 2011.
DOI : 10.1016/j.brachy.2010.10.004

N. N. Stone, M. M. Stone, and B. S. Rosenstein, Influence of Pretreatment and Treatment Factors on Intermediate to Long-Term Outcome After Prostate Brachytherapy, The Journal of Urology, vol.185, issue.2, p.495, 2011.
DOI : 10.1016/j.juro.2010.09.099

S. E. Song, N. Hata, and I. Iordachita, A workspace-orientated needleguiding robot for 3T MRI-guided transperineal prostate intervention: evaluation of inbore workspace and MRI compatibility, Int J Med Robot, p.2012

H. W. Liu, K. Malkoske, and D. Sasaki, The dosimetric quality of brachytherapy implants in patients with small prostate volume depends on the experience of the brachytherapy team, Brachytherapy, vol.9, issue.3, p.202, 2010.
DOI : 10.1016/j.brachy.2009.07.009

E. P. Gibbons, B. L. Jacobs, and R. P. Smith, Dosimetric outcomes in prostate brachytherapy: Is downsizing the prostate with androgen deprivation necessary?, Brachytherapy, vol.8, issue.3, p.304, 2009.
DOI : 10.1016/j.brachy.2008.11.009

F. Bladou, N. Salem, and M. Simonian-sauve, [Permanent iodine 125 implant brachytherapy in localized prostate cancer: results of the first 4 years of experience], Prog Urol, vol.14, p.345, 2004.

W. R. Lee, A. F. Deguzman, and R. L. Bare, Postimplant analysis of transperineal interstitial permanent prostate brachytherapy: evidence for a learning curve in the first year at a single institution, International Journal of Radiation Oncology*Biology*Physics, vol.46, issue.1, p.83, 2000.
DOI : 10.1016/S0360-3016(99)00359-4

P. Acher, R. Popert, and J. Nichol, Permanent prostate brachytherapy: Dosimetric results and analysis of a learning curve with a dynamic dose-feedback technique, International Journal of Radiation Oncology*Biology*Physics, vol.65, issue.3, p.694, 2006.
DOI : 10.1016/j.ijrobp.2006.01.035

M. Lazzeri and G. Guazzoni, Focal therapy meets prostate cancer, The Lancet, vol.376, issue.9746, p.1036, 2010.
DOI : 10.1016/S0140-6736(10)60594-6

S. Eggener, G. Salomon, and P. T. Scardino, Focal Therapy for Prostate Cancer: Possibilities and Limitations, European Urology, vol.58, issue.1, p.57, 2010.
DOI : 10.1016/j.eururo.2010.03.034

N. Betrouni, R. Lopes, and P. Puech, A model to estimate the outcome of prostate cancer photodynamic therapy with TOOKAD Soluble WST11, Physics in Medicine and Biology, vol.56, issue.15, p.4771, 2011.
DOI : 10.1088/0031-9155/56/15/009