. Neutron-interactions, ]. S. Dosimetry-bibliography, and . Eidelman, Particle Data Group: Review of Particle Properties, Phys. Lett. B, vol.592, issue.1, pp.1-5, 2004.

K. Nakamura, Particle Data Group: Review of Particle Physics, J. Phys. G, vol.37, 2010.

W. M. Yao, Particle Data Group: Review of Particle Properties, J. Phys. G, vol.33, pp.1-1232, 2006.

H. H. Andersen, Hydrogen Stopping Powers and Ranges in All Elements (The Stopping and Ranges of Ions in Matter, 1977.

L. Landau, On the energy loss of fast particles by ionization, J. Phs. (USSR), vol.8, p.201, 1994.

N. Tsoulfanidis, Measurement and Detection of Radiation, 1983.

C. Grupen, B. Shwartz, and H. Spieler, Particle Detectors, ser. Cambridge Monographs on Particle Physics, Nuclear Physics, and Cosmology, 2008.

H. Bichsel, Experimental Range of Protons in Al, Physical Review, vol.112, issue.4, pp.1089-1091, 1958.
DOI : 10.1103/PhysRev.112.1089

L. Katz and A. S. Penfold, Range-Energy Relations for Electrons and the Determination of Beta-Ray End-Point Energies by Absorption, Reviews of Modern Physics, vol.24, issue.1, pp.28-44, 1952.
DOI : 10.1103/RevModPhys.24.28

K. Hagiwara, Particle Data Group: Review of Particle Physics, J. Phys. D, vol.66, 2002.

M. Vanstalle, Dosimétrié electronique et métrologie neutrons par capteur CMOS a pixels actifs, 2011.

V. Lacoste, Review of radiation sources, calibration facilities and simulated workplace fields, proceedings of the 11th symposium on neutron and ion dosimetry, pp.1083-1089, 2010.
DOI : 10.1016/j.radmeas.2010.05.036

M. J. Garcia, Neutron spectrometry in complex n-? fields: Application to LINAC and PET facilities, 2010.

G. Noel, L. Feuvret, R. Ferrand, and J. Mazeron, Le traitement par neutrons??: hadronth??rapie partie II??: bases physiques et exp??rience clinique, Cancer/Radioth??rapie, vol.7, issue.5, pp.340-352, 2003.
DOI : 10.1016/S1278-3218(03)00113-6

D. T. Bartlett, Radiation protection aspects of the cosmic radiation exposure of aircraft crew, Radiation Protection Dosimetry, vol.109, issue.4, pp.349-355, 2004.
DOI : 10.1093/rpd/nch311

I. O. Andersson and J. Braun, A neutron rem counter, Nukleonika, vol.6, pp.237-241, 1964.

L. Brackenbush, J. Mcdonald, G. Endres, and W. Quam, Mixed Field Dose Equivalent Measuring Instruments, Radiation Protection Dosimetry, vol.10, issue.1-4, pp.307-318, 1985.
DOI : 10.1093/rpd/10.1-4.307

URL : http://rpd.oxfordjournals.org/cgi/content/short/10/1-4/307

A. Waker, Microdosimetric Radiation Field Characterisation and Dosimetry in a Heavy Water Moderated Reactor Environment, Radiation Protection Dosimetry, vol.52, issue.1-4, pp.415-418, 1994.
DOI : 10.1093/oxfordjournals.rpd.a082225

J. Mcdonald, F. Posny, S. Gerdung-list, J. Chartier, and J. Kurkdjian, Dosimetric measurements in simulated practical neutron fields using several dosemeter systems, Radiation Protection Dosimetry, vol.62, issue.4, pp.197-202, 1995.

L. Braby, C. Ratcliffe, and N. Metting, A portable microdosimetric system, Fifth Symposium on Neutron Dosimetry, pp.321-329, 1984.

A. Aroua, M. , and A. Sannikov, On the use of tissue-equivalent proportional counters in high energy stray radiation fields, Radiation Protection Dosimetry, vol.59, issue.1, pp.49-53, 1995.

H. Ing and H. Birnboim, A bubble-damage polymer detector for neutrons, Nuclear Tracks and Radiation Measurements (1982), vol.8, issue.1-4, pp.285-288, 1982.
DOI : 10.1016/0735-245X(84)90106-6

M. Zielczy´nskizielczy´nski, N. Golnik, and Z. Rusinowski, A computer controlled ambient dose equivalent meter based on a recombination chamber Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and 1. Neutron interactions and dosimetry Associated Equipment, pp.563-567, 1996.

B. Cartwright, E. Shirk, and P. Price, A nuclear-track-recording polymer of unique sensitivity and resolution, Nuclear Instruments and Methods, vol.153, issue.2-3, pp.457-460, 1978.
DOI : 10.1016/0029-554X(78)90989-8

K. Oda, Y. Imasaka, T. Yamauchi, Y. Nakane, A. Endo et al., Radiator design for detecting high-energy neutrons with a nuclear track detector, proceedings of the 22nd International Conference on Nuclear Tracks in Solids. [Online]. Available, pp.570-574, 2005.
DOI : 10.1016/j.radmeas.2005.04.012

K. Shimada, T. Iimoto, and T. Kosako, Design of a high energy neutron dosimeter using CR-39 with multi-layer radiator, proceedings of the 16th Solid State Dosimetry Conference, pp.1778-1781, 2011.
DOI : 10.1016/j.radmeas.2011.10.001

D. Bartlett, R. Tanner, and D. Thomas, Active Neutron Personal Dosemeters - A Review of Current Status, Radiation Protection Dosimetry, vol.86, issue.2, pp.107-122, 1999.
DOI : 10.1093/oxfordjournals.rpd.a032930

F. Errico, M. Luszik-bhadra, and T. Lahaye, State of the art of electronic personal dosimeters for neutrons Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, proceedings of the tenth Symposium on Radiation Measurements and Applications. [Online]. Available, pp.411-414, 2003.

M. Luszik-bhadra, Electronic personal dosemeters: the solution to problems of individual monitoring in mixed neutron/photon fields?, Radiation Protection Dosimetry, vol.110, issue.1-4, pp.747-752, 2004.
DOI : 10.1093/rpd/nch181

F. Errico, D. Bartlett, T. Bolognese-milsztajn, M. Boschung, M. Coeck et al., Evaluation of individual dosimetry in mixed neutron and photon radiation fields (evidos). part i: scope and methods of the project, Radiation Protection Dosimetry, vol.125, pp.1-4, 2007.

H. Schuhmacher, D. Bartlett, T. Bolognese-milsztajn, M. Boschung, M. Coeck et al., Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part II: conclusions and recommendations, Radiation Protection Dosimetry, vol.125, issue.1-4, pp.281-284, 2007.
DOI : 10.1093/rpd/ncm167

M. Reginatto and M. Luszik-bhadra, Determination of the full response function of personal neutron dosemeters, Radiation Protection Dosimetry, vol.125, issue.1-4, pp.285-288, 2007.
DOI : 10.1093/rpd/ncl169

D. Husson, Device simulation of a CMOS pixel detector for MIP tracking Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Available: http, pp.511-513, 2001.

G. Deptuch, New generation of monolithic active pixel sensors for charged particle detection, 2002.
URL : https://hal.archives-ouvertes.fr/tel-00011109

D. Contarato, Silicon Detectors for Particle Tracking at Future High-Energy Physics Experiments, 2005.

G. Masetti, M. Severi, and S. Solmi, Modeling of carrier mobility against carrier concentration in arsenic-, phosphorus-, and boron-doped silicon, IEEE Transactions on Electron Devices, vol.30, issue.7, pp.764-769, 1983.
DOI : 10.1109/T-ED.1983.21207

C. Lombardi, S. Manzini, A. Saporito, and M. Vanzi, A physically based mobility model for numerical simulation of nonplanar devices Computer-Aided Design of Integrated Circuits and Systems, IEEE Transactions on, vol.7, issue.11, pp.1164-1171, 1988.

W. Shockley and W. T. Read, Statistics of the Recombinations of Holes and Electrons, Physical Review, vol.87, issue.5, pp.835-842, 1952.
DOI : 10.1103/PhysRev.87.835

L. Huldt, N. G. Nilsson, and K. G. Svantesson, The temperature dependence of band???to???band Auger recombination in silicon, Applied Physics Letters, vol.35, issue.10, pp.776-777, 1979.
DOI : 10.1063/1.90974

W. Lochmann and A. Haug, Phonon-assisted Auger recombination in Si with direct calculation of the overlap integrals, Solid State Communications, vol.35, issue.7, pp.553-556, 1980.
DOI : 10.1016/0038-1098(80)90896-0

R. Hacker and A. Hangleiter, Intrinsic upper limits of the carrier lifetime in silicon, Journal of Applied Physics, vol.75, issue.11, pp.7570-7572, 1994.
DOI : 10.1063/1.356634

H. S. Bennett and C. L. Wilson, Statistical comparisons of data on band???gap narrowing in heavily doped silicon: Electrical and optical measurements, Journal of Applied Physics, vol.55, issue.10, pp.3582-3587, 1984.
DOI : 10.1063/1.332950

Y. Zhang, C. Hu-guo, D. Husson, and Y. Hu, Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter, 2011 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications, pp.1-7, 2011.
DOI : 10.1109/ANIMMA.2011.6172973

D. Husson, A. Bozier, S. Higueret, T. D. Lê, and A. M. Nourreddine, AlphaRad, a new integrated CMOS System-on-Chip for high efficiency alpha particles counting, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.569, issue.3, pp.845-852, 2006.
DOI : 10.1016/j.nima.2006.09.110

URL : https://hal.archives-ouvertes.fr/hal-00135895

L. Rossi, P. Fischer, T. Rohe, and N. Wermes, Pixel Detectors: From Fundamentals To Applications, 2010.

B. Schneider, M. Strutt, M. Luszik-bhadra, and T. Lahaye, Theory and Experiments on Shot Noise in Silicon P-N Junction Diodes and Transistors State of the art of electronic personal dosimeters for neutrons, Proceedings of the IRE, pp.546-554, 2003.

A. Codino, Gallium arsenide telescope for measuring the time of flight of ionizing particles Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Proceedings of the Fifth International Workshop on GaAs Detectors and Related Compounds. [Online]. Available, pp.12-18, 1998.

M. Paulus, J. Rochelle, M. Andreaco, and D. Binkley, A low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors, IEEE Transactions on Nuclear Science, vol.43, issue.3, pp.1666-1671, 1996.
DOI : 10.1109/23.507167

M. Weng, E. Mandelli, W. Moses, and S. Derenzo, A high-speed low-noise cmos 16-channel charge-sensitive preamplifier asic for apd-based pet detectors, IEEE Transactions on Nuclear Science, vol.50, issue.4, pp.898-902, 2003.
DOI : 10.1109/TNS.2003.814565

Y. Hu, J. D. Berst, and M. Schaeffer, A Very Low Power Consumption, Low Noise Analog Readout Chip for Capacitive Detectors with a Power Supply of 3.3 V, Analog Integrated Circuits and Signal Processing, vol.17, issue.3, pp.249-260, 1998.
DOI : 10.1023/A:1008387815061

URL : https://hal.archives-ouvertes.fr/in2p3-00019634

G. Anelli, K. Borer, L. Casagrande, M. Despeisse, P. Jarron et al., A high-speed low-noise transimpedance amplifier in a 0

P. O. Connor and G. D. Geronimo, Prospects for charge sensitive amplifiers in scaled CMOS, Nucl. Instr. and Meth. A, vol.480, issue.2-3, pp.713-725, 2002.

W. M. Sansen and Z. Y. Chang, Limits of low noise performance of detector readout front ends in CMOS technology, IEEE Transactions on Circuits and Systems, vol.37, issue.11, pp.1375-1382, 1990.
DOI : 10.1109/31.62412

L. Rossi, P. Fischer, T. Rohe, and N. Wermes, Pixel Detectors: From Fundamentals To Applications, 2010.

C. Hu-guo, D. Bonnet, A. Brogna, J. P. Coffin, and E. A. Deptuch, The HAL25 frontend chip for the ALICE silicon strip detectors, Proc. 7th Workshop on Electronics for LHC Experiments, pp.76-80, 2001.
URL : https://hal.archives-ouvertes.fr/in2p3-00012270

F. Krummenacher and N. Joehl, A 4-MHz CMOS continuous-time filter with on-chip automatic tuning Solid-State Circuits, IEEE Journal, vol.23, issue.3, pp.750-758, 1988.

D. Husson, A. Bozier, S. Higueret, T. D. Lê, and A. M. Nourreddine, AlphaRad, a new integrated CMOS System-on-Chip for high efficiency alpha particles counting, Characterization of AlphaRad-2 with radiative sources Bibliography, pp.845-852, 2006.
DOI : 10.1016/j.nima.2006.09.110

URL : https://hal.archives-ouvertes.fr/hal-00135895

J. F. Ziegler, J. P. Biersack, and M. D. Ziegler, SRIM -The Stopping and Range of Ions in Matter, SRIM-2008, 2008.

Y. Zhang, C. Hu-guo, D. Husson, T. Le, S. Higueret et al., A High-Sensitivity Low-Power CMOS Sensor for a Future Neutron Personal Dosimeter, IEEE Transactions on Nuclear Science, vol.59, issue.4, pp.1465-1471, 2012.
DOI : 10.1109/TNS.2012.2195676

M. Vanstalle, Dosimétrié electronique et métrologie neutrons par capteur CMOS a pixels actifs, 2011.

V. Gressier, Les installations de l'IRSN dédiéesdédiéesà la métrologie des neutrons, IRSN/LMDN, Tech. Rep, 2005.

Y. Zhang, C. Hu-guo, D. Husson, T. D. Lê, S. Higueret et al., A High-Sensitivity Low-Power CMOS Sensor for a Future Neutron Personal Dosimeter, IEEE Transactions on Nuclear Science, vol.59, issue.4, pp.1465-1471, 2012.
DOI : 10.1109/TNS.2012.2195676

Y. Zhang, C. Hu-guo, D. Husson, S. Higueret, T. D. Lê et al., Design of a monolithic CMOS sensor for high efficiency neutron counting, Microelectronics Journal, vol.43, issue.11, pp.730-736, 2012.
DOI : 10.1016/j.mejo.2012.07.012

C. , .. Y. Zhang, D. Husson, T. D. Lê, S. Higueret et al., Development of an integrated CMOS sensor for efficient neutron counting, Proceedings Nuclear Science Symposium and Medical Imaging Conference, pp.23-29, 2011.

Y. Zhang, C. Hu-guo, D. Husson, and Y. Hu, Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter, 2011 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications, pp.6-9, 2011.
DOI : 10.1109/ANIMMA.2011.6172973