. J. Agence-de-l-'environnement-et-de-la-maitrise and . Anderson, Energie (ADEME) report, Guide de redaction du cahier des charges techniques des générateurs photovoltaïques connectées au réseau, ADEME/PVC/V1 available at www.ademe.fr/ [AND'96] A Photovoltaic Translation Equations: A New Approach, pp.604-612, 1996.

F. Antony, Le photovoltaïque pour tous : conception et réalisation d'installations, Observ'ER, p.39, 2006.

]. D. Babajee, An analysis of the properties of the variants of Newton???s method with third order convergence, Applied Mathematics and Computation, vol.183, issue.1, pp.659-684, 2006.
DOI : 10.1016/j.amc.2006.05.116

P. Bastiani, Stratégies de commande minimisant les pertes d'un ensemble convertisseur-machine alternative : application à la traction électrique, thesis from INSA- Lyon exposed, 2001.

G. Blaesser, Extrapolation of Outdoor Measurements of PV array I-V Characteristics to Standard Test Conditions, Solar Cells, pp.91-96, 1988.

A. Bratcu, Power optimization strategy for cascaded DC-DC converter architectures of photovoltaic modules, 2009 IEEE International Conference on Industrial Technology, pp.1-8, 2009.
DOI : 10.1109/ICIT.2009.4939559

URL : https://hal.archives-ouvertes.fr/hal-00364440

A. Bratcu, Cascaded DC-DC Converter Photovoltaic Systems: Power Optimization Issues Power loss in photovoltaic arrays due to mismatch cell characteristics, IEEE Transactions on Industrial Electronics, vol.9923, pp.277-288, 1979.

B. Burger, Extreme High Efficiency PV-Power Converters, European Conference EPE'09, pp.1-13, 2009.

J. M. Carrasco, Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey, IEEE Transactions on Industrial Electronics, vol.53, issue.4, pp.1002-1016, 2006.
DOI : 10.1109/TIE.2006.878356

S. Chokmaviroj, Performance of a 500 kWp grid connected photovoltaic system at Mae Hong Son Province, pp.3119-3147, 2006.

V. Dang, Conception d'une interface d'électronique de puissance pour Pile à Combustible, thesis from, 2006.

W. and D. Soto, Improvement and validation of a model for photovoltaic array performance, Master of Science in Mechanical Engineering, pp.20-66, 2004.

J. Ding, A new method to determine the optimum load of a real solar cell using the Lambert W-function, Solar Energy Materials and Solar Cells, vol.92, issue.12, pp.1566-1569, 2008.
DOI : 10.1016/j.solmat.2008.07.004

M. Drif, Univer Project. A grid connected photovoltaic system of 200kWp at Ja??n University. Overview and performance analysis, Solar Energy Materials and Solar Cells, vol.91, issue.8, pp.670-683, 2007.
DOI : 10.1016/j.solmat.2006.12.006

F. Electricité-de, Accès au réseau basse-tension pour les installations photovoltaïques : Condtions techniques et contractuelles du raccordement [EER'10] Energy Efficiency and Renewable Energy (EERE) U.S. Department of Energy, Solar technologies market report, available at www.eere.energy.gov/ [EPIA'09] European Photovoltaic Industry Association (EPIA), Global market outlook for photovoltaics until 2013, 2008.

]. N. Gautam, GET'06] program available at http://www.math.ucla.edu/~getreuer/lambertw.html/ [GRA'06] MOSFET Power Losses Calculation Using the Data-Sheet Parameters, Dr. Dusan Graovac Application note v1, www.infineon.com/ [GRA'09] IGBT Power Losses Calculation Using the Data-Sheet Parameters, Dr. Dusan Graovac, Marco Purschel, Application note v1, Progress in photovoltaics : Research & Applications, pp.129-141, 2002.

A. Jain, Solar cell array parameters using Lambert W-function, Solar Energy Materials and Solar Cells, vol.90, issue.1, pp.25-31, 2006.
DOI : 10.1016/j.solmat.2005.01.007

V. Kanwar, Modified families of Newton, Halley and Chebyshev methods, Applied Mathematics and Computation, vol.192, issue.1, pp.20-26, 2007.
DOI : 10.1016/j.amc.2007.02.119

N. D. Kaushika, An investigation of mismatch losses in solar photovoltaic cell networks, Energy, vol.32, issue.5, pp.755-759, 2007.
DOI : 10.1016/j.energy.2006.06.017

S. Kazmi, An improved and very efficient MPPT controller for PV systems subjected to rapidly varying atmospheric conditions and partial shading, p.9

K. L. Kennerud, Analysis of Performance Degradation in CdS Solar Cells, IEEE Transactions on Aerospace and Electronic Systems, vol.5, issue.6, pp.912-917, 1969.
DOI : 10.1109/TAES.1969.309966

K. Kiranmayi, Modeling and a MPPT method for solar cells, Journal of Engineering and Applied Sciences, vol.3, pp.128-133, 2008.

J. Li, A novel stand-alone PV generation system based on variable step size INC MPPT and SVPWM control, Conference Proceedings, pp.2155-2160, 2009.

B. Marion, A method for modeling the current-voltage curve of a PV module for outdoor conditions, Progress in Photovoltaics : Research & Applications, pp.205-214, 2002.
DOI : 10.1002/pip.403

M. Megdiche, Sureté de fonctionnement des réseaux de distribution en presence de production decentralisée, INPG thesis presented, 2004.

]. E. Meyer, Assessing the Reliability and Degradation of Photovoltaic Module Performance Parameters, IEEE Transactions on Reliability, vol.53, issue.1, pp.83-92, 2004.
DOI : 10.1109/TR.2004.824831

J. Ma, Myrzik et al, String and module integrated inverters for single-phase photovoltaic systems, p.3, 2003.

D. Nguyen, An Adaptive Solar Photovoltaic Array Using Model-Based Reconfiguration Algorithm, IEEE Transactions on Industrial Electronics, vol.55, issue.7, pp.2644-2654, 2008.
DOI : 10.1109/TIE.2008.924169

]. A. Pavan, Power Electronic Conditioning Systems for Industrial Photovoltaic Fields: Centralized or String Inverters?, 2007 International Conference on Clean Electrical Power, pp.7208-214, 2007.
DOI : 10.1109/ICCEP.2007.384213

. Iea and . Report, Innovative Electrical Concepts, available at www.iea-pvps.org/ [PVPS'02] IEA PVPS Report, Grid-connected photovoltaic power systems : Survey of inverter and related protection equipments, 2001.

T. Shimizu, A novel high-performance utility-interactive photovoltaic inverter system, IEEE Transactions on Power Electronics, vol.18, issue.2, pp.704-711, 2003.
DOI : 10.1109/TPEL.2003.809375

S. Silvestre, Effects of shadowing on photovoltaic module performance, Progress in Photovoltaics : Research and Applications, pp.141-149, 2008.
DOI : 10.1002/pip.780

. Solarbuzz and . Com, Solar Module Price Highlights, Solarbuzz LLC, 2010.

. Greenpeace, Solar Generation V-2008: Solar electricity for over one billion people and two million jobs by 2020

. L. Tal-'10-]-d and . Talavera, The internal rate of return of photovoltaic grid-connected systems: A comprehensive sensitivity analysis, Renewable Energy, vol.35, pp.101-111, 2010.

K. Ujiie, Study on dynamic and static characteristics of photovoltaic cell, Power Conversion Conference Osaka, Japan, pp.810-815, 2002.

G. R. Walker, Cascaded DC???DC Converter Connection of Photovoltaic Modules, IEEE Transactions on Power Electronics, vol.19, issue.4, pp.1130-1138, 2004.
DOI : 10.1109/TPEL.2004.830090

W. J. Wang, Analysis of Partially Shaded PV Modules Using Piecewise Linear Parallel Branches Model, World Academy of Science, Engineering and Technology, vol.60, pp.783-789, 2009.

E. W. Weisstein-mathworld--a-wolfram-web-resource and ]. J. Wiles, Nonlinear Least Squares Fitting http://mathworld.wolfram.com/NonlinearLeastSquaresFitting.html [WIL'97 Blocking diodes and fuses in low-voltage PV systems, 26 th Photovoltaic Specialists Conference, pp.1105-1108, 1997.

E. M. Wright, Solution of the equation $ze^z = a$, Bulletin of the American Mathematical Society, vol.65, issue.2, pp.89-93, 1959.
DOI : 10.1090/S0002-9904-1959-10290-1

M. Wuest, Single cell converter system (SCCS), Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion, WCPEC (A Joint Conference of PVSC, PVSEC and PSEC), pp.94813-815, 1994.
DOI : 10.1109/WCPEC.1994.520084

T. Yamamoto, Historical developments in convergence analysis for Newton's and Newton-like methods, Journal of Computational and Applied Mathematics, vol.124, issue.1-2, pp.1-23, 2000.
DOI : 10.1016/S0377-0427(00)00417-9

H. Yoshioka, Non hot-spot PV module using solar cells with bypass diode function, 25 th IEEE Photovoltaic Specialists Conference, pp.1271-1274, 1996.