non-proliferation.irsn.fr The Black Death Medical management of Chemical and Biological Casualties The silent weapons Harris, Factories of Death: Japanese Biological Warfare, 1932-45, and the American Cover-Up International Humanitarian Law -Protocole de Genève 1925 Convention on the Prohibition of the Development, Production and Stockpiling of Bacteriological (Biological) and Toxin Weapons and on Their Destruction Contrôle de l'interdiction des armes biologiques : un état des lieux, IRSN -Institut de radioprotection et de sûreté nucléaire Sofia, Bulgaria. [4], 1968. ,
Analyzing The Anthrax Attacks, 2005. ,
Chemical and Biological Defense Defense Threat Reduction Agency, www.dtra.mil [16 Mission and Vision of the Joint Program Executive Office for Chemical and Biological Defense Chemical and Biological Defense Program, 19] A.F. Collings et F. Caruso, Reports on Progess in Physics, 1997. ,
The Enzyme Electrode, Nature, vol.18, issue.5092, pp.986-988, 1967. ,
DOI : 10.1021/ac60238a014
Biosensor technology: Technology push versus market pull, Biotechnology Advances, vol.26, issue.5, pp.492-500, 2008. ,
DOI : 10.1016/j.biotechadv.2008.05.007
Imprinted polymer-based enantioselective acoustic sensor using a quartz crystal microbalance, Analytical Communications, vol.326, issue.11-12, pp.391-393, 1999. ,
DOI : 10.1039/a907844d
A B Cell-Based Sensor for Rapid Identification of Pathogens, Science, vol.301, issue.5630, pp.213-215, 2003. ,
DOI : 10.1126/science.1084920
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY, Annals of the New York Academy of Sciences, vol.12, issue.2, pp.29-45, 1962. ,
DOI : 10.1111/j.1749-6632.1962.tb13623.x
Review of the use of biosensors as analytical tools in the food and drink industries, Food Chemistry, vol.77, issue.2, pp.237-256, 2002. ,
DOI : 10.1016/S0308-8146(02)00104-8
Current research activity in biosensors, Analytical and Bioanalytical Chemistry, vol.377, issue.3, pp.446-468, 2003. ,
DOI : 10.1007/s00216-003-1947-5
Biosensor technology for determination of BOD, Field Analytical Chemistry & Technology, vol.2, issue.6, pp.333-340, 1999. ,
DOI : 10.1002/(SICI)1520-6521(1998)2:6<333::AID-FACT3>3.0.CO;2-0
Determination of cyanide using a microbial sensor, Applied Biochemistry and Biotechnology, vol.13, issue.3, pp.97-106, 1996. ,
DOI : 10.1007/BF02788064
A disposable immunomagnetic electrochemical sensor based on functionalised magnetic beads and carbon-based screen-printed electrodes (SPCEs) for the detection of polychlorinated biphenyls (PCBs), Analytica Chimica Acta, vol.538, issue.1-2, pp.205-212, 2005. ,
DOI : 10.1016/j.aca.2005.01.073
A Disposable Biosensor for Organophosphorus Nerve Agents Based on Carbon Nanotubes Modified Thick Film Strip Electrode, Electroanalysis, vol.288, issue.1, pp.54-58, 2005. ,
DOI : 10.1002/elan.200403118
Piezoelectric Biosensor for Detection of Salmonella typhimurium, Journal of Food Science, vol.57, issue.3, pp.1067-1086, 1997. ,
DOI : 10.1111/j.1365-2621.1997.tb15039.x
Rapid and sensitive biosensor for Salmonella, Biosensors and Bioelectronics, vol.15, issue.3-4, pp.135-141, 2000. ,
DOI : 10.1016/S0956-5663(00)00067-1
URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.596.4799
Biomolecular sensors, 2002. ,
Required technology breakthroughs to assume widely accepted biosensors, Applied Biochemistry and Biotechnology, vol.22, issue.No. 4, pp.109-128, 1993. ,
DOI : 10.1007/BF02918537
Fiber-Optic Nitric Oxide-Selective Biosensors and Nanosensors, Analytical Chemistry, vol.70, issue.5, pp.971-976, 1998. ,
DOI : 10.1021/ac970706k
Electrochemical Detection of a One-Base Mismatch in an Oligonucleotide Using Ion-Channel Sensors with Self-Assembled PNA Monolayers, Electroanalysis, vol.4, issue.16, pp.1272-1276, 2000. ,
DOI : 10.1002/1521-4109(200011)12:16<1272::AID-ELAN1272>3.0.CO;2-F
Biosensor for the specific detection of a single viable B.??anthracis spore, Analytical and Bioanalytical Chemistry, vol.282, issue.3, pp.319-327, 2003. ,
DOI : 10.1016/S0956-5663(02)00162-8
Detection of Francisella tularensis within Infected Mouse Tissues by Using a Hand-Held PCR Thermocycler, Journal of Clinical Microbiology, vol.41, issue.2, pp.689-693, 2003. ,
DOI : 10.1128/JCM.41.2.689-693.2003
A handheld real time thermal cycler for bacterial pathogen detection, Biosensors and Bioelectronics, vol.18, issue.9, pp.1115-1123, 2003. ,
DOI : 10.1016/S0956-5663(02)00252-X
Sensitive and Rapid Identification of Biological Threat Agents, Annals of the New York Academy of Sciences, vol.162, issue.1 FOOD AND AGRI, pp.130-148, 2000. ,
DOI : 10.1001/jama.278.5.428
Immunology: a short course, 2000. ,
Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors, Applied Physics Letters, vol.91, issue.10, p.103901, 2007. ,
DOI : 10.1063/1.2779965
Rapid and sensitive biosensor for Salmonella, Biosensors and Bioelectronics, vol.15, issue.3-4, pp.135-141, 2000. ,
DOI : 10.1016/S0956-5663(00)00067-1
The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance, Journal of Virological Methods, vol.162, issue.1-2, pp.14-21, 2009. ,
DOI : 10.1016/j.jviromet.2009.07.001
Biosensor technology for detecting biological warfare agents: Recent progress and future trends, Analytica Chimica Acta, vol.559, issue.2, pp.137-151, 2006. ,
DOI : 10.1016/j.aca.2005.12.020
The Analyst, pp.29-32, 1996. ,
USE OF SURFACE PLASMON RESONANCE TO PROBE THE EQUILIBRIUM AND DYNAMIC ASPECTS OF INTERACTIONS BETWEEN BIOLOGICAL MACROMOLECULES, Annual Review of Biophysics and Biomolecular Structure, vol.26, issue.1, pp.541-566, 1997. ,
DOI : 10.1146/annurev.biophys.26.1.541
Antibody-coated tube method for radioimmunoassay of human growth hormone, Clinica Chimica Acta, vol.27, issue.2, pp.267-279, 1970. ,
DOI : 10.1016/0009-8981(70)90344-X
Problems and approaches in covalent attachment of peptides and proteins to inorganic surfaces for biosensor applications, Journal of Industrial Microbiology, vol.1, issue.3, pp.137-143, 1994. ,
DOI : 10.1007/BF01583997
Nanopatterning at the Service of Single Molecule Assays, Biophysical Journal, vol.98, issue.3, p.758, 2010. ,
DOI : 10.1016/j.bpj.2009.12.4163
Approaches to the immobilization of proteins at surfaces for analysis by scanning tunneling microscopy, Langmuir, vol.9, issue.9, pp.2356-2362, 1993. ,
DOI : 10.1021/la00033a018
Self-assembled thiol monolayers with carboxylic acid functionality: measuring pH-dependent phase transitions with the quartz crystal microbalance, The Journal of Physical Chemistry, vol.96, issue.13, pp.5224-5228, 1992. ,
DOI : 10.1021/j100192a010
Observation of n-octadecanethiol multilayer formation from solution onto gold, Langmuir, vol.9, issue.8, pp.1941-1944, 1993. ,
DOI : 10.1021/la00032a001
SPR Studies of the Nonspecific Adsorption Kinetics of Human IgG and BSA on Gold Surfaces Modified by Self-Assembled Monolayers (SAMs), Journal of Colloid and Interface Science, vol.185, issue.1, pp.94-103, 1997. ,
DOI : 10.1006/jcis.1996.4586
Protein adsorption to oligo(ethylene glycol) self-assembled monolayers: Experiments with fibrinogen, heparinized plasma, and serum, Journal of Biomaterials Science, Polymer Edition, vol.9, issue.1, pp.581-597, 2001. ,
DOI : 10.1163/156856201316883421
An Introduction to Ultrathin Organic Films from Langmuir?Blodgett to Self- Assembly, 1991. ,
A fiber optic biosensor: combination tapered fibers designed for improved signal acquisition, Biosensors and Bioelectronics, vol.8, issue.5, pp.249-256, 1993. ,
DOI : 10.1016/0956-5663(93)80012-E
Thoughts on the Structure of Alkylsilane Monolayers, Langmuir, vol.15, issue.8, pp.2773-2778, 1999. ,
DOI : 10.1021/la981064e
Miniaturized total chemical analysis systems: A novel concept for chemical sensing, Sensors and Actuators B: Chemical, vol.1, issue.1-6, pp.244-248, 1990. ,
DOI : 10.1016/0925-4005(90)80209-I
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology, Analytical Chemistry, vol.74, issue.12, pp.2623-2636, 2002. ,
DOI : 10.1021/ac0202435
Surface plasmon resonance (BIACORE) detection of serum antibodies against Salmonella enteritidis and Salmonella typhimurium, Journal of Immunological Methods, vol.266, issue.1-2, pp.33-44, 2002. ,
DOI : 10.1016/S0022-1759(02)00102-3
Control of the Specific Adsorption of Proteins onto Gold Surfaces with Poly(L-lysine) Monolayers, Analytical Chemistry, vol.67, issue.24, pp.4452-4457, 1995. ,
DOI : 10.1021/ac00120a003
-poly(ethylene glycol) Layers on Metal Oxide Surfaces:?? Surface-Analytical Characterization and Resistance to Serum and Fibrinogen Adsorption, Langmuir, vol.17, issue.2, pp.489-498, 2001. ,
DOI : 10.1021/la000736+
URL : https://hal.archives-ouvertes.fr/hal-00309089
-poly(ethylene glycol):?? A Novel Polymeric Interface for Bioaffinity Sensing, Langmuir, vol.18, issue.1, pp.220-230, 2002. ,
DOI : 10.1021/la010913m
URL : https://hal.archives-ouvertes.fr/hal-00309089
In Pursuit of Zero: Polymer Brushes that Resist the Adsorption of Proteins, Advanced Materials, vol.260, issue.23, pp.2441-2446, 2009. ,
DOI : 10.1002/adma.200803125
???Non-Fouling??? Oligo(ethylene glycol)- Functionalized Polymer Brushes Synthesized by Surface-Initiated Atom Transfer Radical Polymerization, Advanced Materials, vol.16, issue.4, pp.338-341, 2004. ,
DOI : 10.1002/adma.200305830
Influence of Coupling Method on the Luminescence Properties, Coupling Efficiency, and Binding Affinity of Antibodies Labeled with Europium(III) Chelates, Bioconjugate Chemistry, vol.8, issue.1, pp.71-75, 1997. ,
DOI : 10.1021/bc960075l
A sensitive and specific fluorescence assay for tissue serotonin, Biochemical Pharmacology, vol.14, issue.5, pp.831-835, 1965. ,
DOI : 10.1016/0006-2952(65)90102-4
DNA chips: State-of-the art, Nature Biotechnology, vol.2, issue.31, pp.40-44, 1998. ,
DOI : 10.1006/geno.1996.0219
A Portable Array Biosensor for Detecting Multiple Analytes in Complex Samples, Microbial Ecology, vol.47, issue.2, pp.175-185, 2004. ,
DOI : 10.1007/s00248-003-1011-1
Optical fiber-based sensors: application to chemical biology, Current Opinion in Chemical Biology, vol.9, issue.5, pp.494-500, 2005. ,
DOI : 10.1016/j.cbpa.2005.08.009
Biochip readout system for point-of-care applications, Sensors and Actuators B: Chemical, vol.139, issue.1, pp.245-251, 2009. ,
DOI : 10.1016/j.snb.2009.02.052
RAPTOR: A portable, automated biosensor, Proceedings of the First Conference on Point Detection for Chemical and Biological Defense, 2000. ,
Multiplexed fluid array screening of phage displayed anti-ricin single domain antibodies for rapid assessment of specificity, BioTechniques, vol.43, issue.6, pp.806-811, 2007. ,
DOI : 10.2144/000112600
Characterization of biomembranes by spectral ellipsometry, surface plasmon resonance and interferometry with regard to biosensor application, Biosensors and Bioelectronics, vol.9, issue.2, pp.139-146, 1994. ,
DOI : 10.1016/0956-5663(94)80105-3
Zeitschrift für Physik A Hadrons and Nuclei, pp.398-410, 1968. ,
Performance of the Spreeta 2000 integrated surface plasmon resonance affinity sensor, Sensors and Actuators B: Chemical, vol.91, issue.1-3, pp.266-274, 2003. ,
DOI : 10.1016/S0925-4005(03)00113-8
Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor, Biosensors and Bioelectronics, vol.17, issue.6-7, pp.573-584, 2002. ,
DOI : 10.1016/S0956-5663(02)00014-3
Biosensors for Biological Warfare Agent Detection, Defence Science Journal, vol.57, issue.3, pp.185-193, 2007. ,
DOI : 10.14429/dsj.57.1760
Amperometric immunosensor for detection of antibodies of Salmonella typhi in patient serum, Analytica Chimica Acta, vol.531, issue.2, pp.173-177, 2005. ,
DOI : 10.1016/j.aca.2004.10.015
Amperometric Glucose Biosensor Based on Sol???Gel Organic???Inorganic Hybrid Material, Analytical Chemistry, vol.70, issue.15, pp.3170-3174, 1998. ,
DOI : 10.1021/ac980160h
A biosensor for Escherichia coli based on a potentiometric alternating biosensing (PAB) transducer, Sensors and Actuators B: Chemical, vol.83, issue.1-3, pp.48-52, 2002. ,
DOI : 10.1016/S0925-4005(01)01027-9
Effect of two types of surface sites on the characteristics of Si3N4-gate pH-ISFETs, Sensors and Actuators B: Chemical, vol.37, issue.1-2, pp.13-17, 1996. ,
DOI : 10.1016/S0925-4005(97)80067-6
The pH-sensing properties of tantalum pentoxide films fabricated by metal organic low pressure chemical vapor deposition, Sensors and Actuators B: Chemical, vol.44, issue.1-3, pp.262-267, 1997. ,
DOI : 10.1016/S0925-4005(97)00166-4
Study on the temperature effect, hysteresis and drift of pH-ISFET devices based on amorphous tungsten oxide, Sensors and Actuators B: Chemical, vol.76, issue.1-3, pp.624-628, 2001. ,
DOI : 10.1016/S0925-4005(01)00657-8
Development of pH-ISFET sensors for the detection of bacterial activity, Sensors and Actuators B: Chemical, vol.103, issue.1-2, pp.247-251, 2004. ,
DOI : 10.1016/j.snb.2004.04.056
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species, Science, vol.293, issue.5533, pp.1289-1292, 2001. ,
DOI : 10.1126/science.1062711
Development of a conductometric nitrate biosensor based on Methyl viologen/Nafion?? composite film, Electrochemistry Communications, vol.8, issue.2, pp.201-205, 2006. ,
DOI : 10.1016/j.elecom.2005.11.006
URL : https://hal.archives-ouvertes.fr/hal-00141454
Combined physico-chemical and biological sensing in environmental monitoring, Biosensors and Bioelectronics, vol.18, issue.5-6, pp.667-674, 2003. ,
DOI : 10.1016/S0956-5663(03)00012-5
Piezoelectricity: An Introduction to the Theory and Applications of Electromechanical Phenomena in Crystals, 1964. ,
Detection of viral bioagents using a shear horizontal surface acoustic wave biosensor, Biosensors and Bioelectronics, vol.23, issue.9, pp.1397-1403, 2008. ,
DOI : 10.1016/j.bios.2007.12.016
Harmonic frequency analysis of SAW resonator chemical sensors: application to the detection of carbon dioxide and humidity1Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by Lockheed Martin Energy Research Corporation for the US Department of Energy under Contract No. DE-AC05-96OR22464.1, Sensors and Actuators B: Chemical, vol.50, issue.2, pp.110-116, 1998. ,
DOI : 10.1016/S0925-4005(98)00163-4
Verwendung von Schwingquarzen zur W???gung d???nner Schichten und zur Mikrow???gung, Zeitschrift f???r Physik, vol.155, issue.2, pp.206-222, 1959. ,
DOI : 10.1007/BF01337937
The oxidation of aluminum films in low-pressure oxygen atmospheres, Surface Science, vol.9, issue.2, pp.217-245, 1968. ,
DOI : 10.1016/0039-6028(68)90174-X
Viscoelastic Acoustic Response of Layered Polymer Films at Fluid-Solid Interfaces: Continuum Mechanics Approach, Physica Scripta, vol.59, issue.5, pp.391-396, 1999. ,
DOI : 10.1238/Physica.Regular.059a00391
Real-time detection of mesothelin in pancreatic cancer cell line supernatant using an acoustic wave immunosensor, Cancer Detection and Prevention, vol.30, issue.2, pp.180-187, 2006. ,
DOI : 10.1016/j.cdp.2006.03.004
Sensing Escherichia coli O157:H7 via frequency shift through a self-assembled monolayer based QCM immunosensor, Journal of Zhejiang University SCIENCE B, vol.9, issue.2, pp.121-131, 2008. ,
DOI : 10.1631/jzus.B0710307
Variations in Coupled Water, Viscoelastic Properties, and Film Thickness of a Mefp-1 Protein Film during Adsorption and Cross-Linking:?? A Quartz Crystal Microbalance with Dissipation Monitoring, Ellipsometry, and Surface Plasmon Resonance Study, Analytical Chemistry, vol.73, issue.24, pp.5796-5804, 2001. ,
DOI : 10.1021/ac0106501
Rapid detection of Bacillus anthracis using monoclonal antibody functionalized QCM sensor, Biosensors and Bioelectronics, vol.24, issue.5, pp.1330-1335, 2009. ,
DOI : 10.1016/j.bios.2008.07.071
A protein A-based orientation-controlled immobilization strategy for antibodies using nanometer-sized gold particles and plasma-polymerized film, Analytical Biochemistry, vol.324, issue.2, pp.219-226, 2004. ,
DOI : 10.1016/j.ab.2003.09.032
Microgravimetric immunosensor for direct detection of aerosolized influenza A virus particles, Sensors and Actuators B: Chemical, vol.126, issue.2, pp.691-699, 2007. ,
DOI : 10.1016/j.snb.2007.04.028
The resonant gate transistor, IEEE Transactions on Electron Devices, vol.14, issue.3, pp.117-133, 1967. ,
DOI : 10.1109/T-ED.1967.15912
BioMEMS: state-of-the-art in detection, opportunities and prospects, Advanced Drug Delivery Reviews, vol.56, issue.11, pp.1565-1586, 2004. ,
DOI : 10.1016/j.addr.2004.03.002
Biosensors, Sensors and Actuators A: Physical, vol.134, pp.555-564, 2007. ,
Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device, Nature Biotechnology, vol.5, issue.4, pp.437-438, 2006. ,
DOI : 10.1038/nbt1199
MEMS-based micropumps in drug delivery and biomedical applications, Sensors and Actuators B: Chemical, vol.130, issue.2, pp.917-942, 2008. ,
DOI : 10.1016/j.snb.2007.10.064
A review of microvalves, Journal of Micromechanics and Microengineering, vol.16, issue.5, p.13, 2006. ,
DOI : 10.1088/0960-1317/16/5/R01
Nanotribology and nanomechanics of MEMS/NEMS and BioMEMS/BioNEMS materials and devices, Microelectronic Engineering, vol.84, issue.3, pp.387-412, 2007. ,
DOI : 10.1016/j.mee.2006.10.059
A uniaxial bioMEMS device for imaging single cell response during quantitative force-displacement measurements, Biomedical Microdevices, vol.109, issue.Pt 17, pp.883-889, 2008. ,
DOI : 10.1007/s10544-008-9202-7
Cell Mechanics: Integrating Cell Responses to Mechanical Stimuli, Annual Review of Biomedical Engineering, vol.9, issue.1, pp.1-34, 2007. ,
DOI : 10.1146/annurev.bioeng.9.060906.151927
BIOMEMS AND NANOTECHNOLOGY-BASED APPROACHES FOR RAPID DETECTION OF BIOLOGICAL ENTITIES, Journal of Rapid Methods and Automation in Microbiology, vol.2, issue.3, pp.1-32, 2007. ,
DOI : 10.1016/S0003-2670(97)00560-6
Atomic Force Microscope, Physical Review Letters, vol.56, issue.9, p.930, 1986. ,
DOI : 10.1103/PhysRevLett.56.930
The Tension of Metallic Films Deposited by Electrolysis, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, vol.82, issue.553, pp.172-175, 1909. ,
DOI : 10.1098/rspa.1909.0021
Label-Free Protein Recognition Two-Dimensional Array Using Nanomechanical Sensors, Nano Letters, vol.8, issue.2, pp.520-524, 2008. ,
DOI : 10.1021/nl072740c
Sequential position readout from arrays of micromechanical cantilever sensors, Applied Physics Letters, vol.72, issue.3, p.383, 1998. ,
DOI : 10.1063/1.120749
MOSFET-Embedded Microcantilevers for Measuring Deflection in Biomolecular Sensors, Science, vol.311, issue.5767, pp.1592-1595, 2006. ,
DOI : 10.1126/science.1122588
Environmental sensors based on micromachined cantilevers with integrated read-out, Ultramicroscopy, vol.82, issue.1-4, pp.11-16, 2000. ,
DOI : 10.1016/S0304-3991(99)00148-5
Force Sensors Based on Screen-Printed Cantilevers, IEEE Sensors Journal, vol.10, issue.6, pp.1133-1137, 2010. ,
DOI : 10.1109/JSEN.2010.2040387
URL : https://hal.archives-ouvertes.fr/hal-00453483
An analytical model for transient deformation of viscoelastically coated beams: Applications to static-mode microcantilever chemical sensors, Journal of Applied Physics, vol.105, issue.12, p.124903, 2009. ,
DOI : 10.1063/1.3148291
URL : https://hal.archives-ouvertes.fr/hal-00383067
An industrial CMOS process family adapted for the fabrication of smart silicon sensors, Sensors and Actuators A: Physical, vol.84, issue.1-2, pp.126-133, 2000. ,
DOI : 10.1016/S0924-4247(99)00348-9
Microfabricated mechanical biosensor with inherently differential readout, Applied Physics Letters, vol.83, issue.8, p.1659, 2003. ,
DOI : 10.1063/1.1605238
Theoretical and experimental investigation of optically driven nanoelectromechanical oscillators, Journal of Applied Physics, vol.107, issue.3, p.34311, 2010. ,
DOI : 10.1063/1.3305464
Wireless bimorph micro-actuators by pulsed laser heating, Sensors and Actuators A: Physical, vol.121, issue.1, pp.35-43, 2005. ,
DOI : 10.1016/j.sna.2004.12.012
Electromagnetic actuation and MOS-transistor sensing for CMOS-integrated micromechanical resonators, Sensors and Actuators A: Physical, vol.103, issue.1-2, pp.150-155, 2003. ,
DOI : 10.1016/S0924-4247(02)00307-2
Pressure dependent resonant frequency of micromechanical drumhead resonators, Applied Physics Letters, vol.94, issue.21, p.213506, 2009. ,
DOI : 10.1063/1.3141731
Characterization of vaccinia virus particles using microscale silicon cantilever resonators and atomic force microscopy, Sensors and Actuators B: Chemical, vol.115, issue.1, pp.189-197, 2006. ,
DOI : 10.1016/j.snb.2005.08.047
Liquid-Phase Chemical and Biochemical Detection Using Fully Integrated Magnetically Actuated Complementary Metal Oxide Semiconductor Resonant Cantilever Sensor Systems, Analytical Chemistry, vol.79, issue.4, pp.1646-1654, 2007. ,
DOI : 10.1021/ac061795g
Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever, Sensors and Actuators A: Physical, vol.122, issue.2, pp.326-334, 2005. ,
DOI : 10.1016/j.sna.2005.05.012
Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300spores/mL, Biosensors and Bioelectronics, vol.21, issue.9, pp.1684-1692, 2006. ,
DOI : 10.1016/j.bios.2005.08.001
Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers, Biosensors and Bioelectronics, vol.21, issue.3, pp.462-473, 2005. ,
DOI : 10.1016/j.bios.2004.11.009
Weighing of biomolecules, single cells and single nanoparticles in fluid, Nature, vol.442, issue.7139, pp.1066-1069, 2007. ,
DOI : 10.1038/nature05741
Label-Free Biomarker Sensing in Undiluted Serum with Suspended Microchannel Resonators, Analytical Chemistry, vol.82, issue.5, pp.1905-1910, 2010. ,
DOI : 10.1021/ac9027356
Study of the noise of micromechanical oscillators under quality factor enhancement via driving force control, Journal of Applied Physics, vol.97, issue.4, p.44903, 2005. ,
DOI : 10.1063/1.1847729
Piezoelectric actuation of PZT thin-film diaphragms at static and resonant conditions, Sensors and Actuators A: Physical, vol.53, issue.1-3, pp.398-404, 1996. ,
DOI : 10.1016/0924-4247(96)01139-9
Ultrasonic flexural Lamb-wave actuators based on PZT thin film, Sensors and Actuators A: Physical, vol.64, issue.1, pp.41-49, 1998. ,
DOI : 10.1016/S0924-4247(98)80056-3
Piezoelectric diaphragm as a high performance biosensor platform, Applied Physics Letters, vol.89, issue.22, p.223508, 2006. ,
DOI : 10.1063/1.2396919
Resonating piezoelectric membranes for microelectromechanically based bioassay: detection of streptavidin???gold nanoparticles interaction with biotinylated DNA, Sensors and Actuators B: Chemical, vol.110, issue.1, pp.125-136, 2005. ,
DOI : 10.1016/j.snb.2005.01.021
URL : https://hal.archives-ouvertes.fr/hal-00130821
Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007. ,
Combining Resonant Piezoelectric Micromembranes with Molecularly Imprinted Polymers, Angewandte Chemie, vol.542, issue.48, pp.9431-9434, 2007. ,
DOI : 10.1002/ange.200703881
URL : https://hal.archives-ouvertes.fr/hal-00198071
Multi-Mode Air Damping Analysis of Composite Cantilever Beams, Japanese Journal of Applied Physics, vol.38, issue.Part 1, No. 11, pp.6521-6525, 1999. ,
DOI : 10.1143/JJAP.38.6521
Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007. ,
On the Vibrations of an Elastic Plate in Contact with Water, Proceedings of the royal society of London, pp.205-216, 1920. ,
DOI : 10.1098/rspa.1920.0064
Formulas for Natural Frequency and Mode Shape, Journal of Applied Mechanics, vol.47, issue.2, 1979. ,
DOI : 10.1115/1.3153712
Study of the mechanical and microstructural state of platinum thin films, Thin Solid Films, vol.275, issue.1-2, pp.22-24, 1996. ,
DOI : 10.1016/0040-6090(95)07011-7
True Young modulus of Pb(Zr,Ti)O3 films measured by nanoindentation, Applied Physics Letters, vol.85, issue.22, p.5185, 2004. ,
DOI : 10.1063/1.1827331
URL : https://hal.archives-ouvertes.fr/hal-00141178
Stress-based vapor sensing using resonant microbridges, Applied Physics Letters, vol.96, issue.16, p.163503, 2010. ,
DOI : 10.1063/1.3393999
Thin Film Zinc Oxide Microsensors and Microactuators, thèse, 1997. ,
Electronic Scheme for Multiplexed Dynamic Behavior Excitation and Detection of Piezoelectric Silicon-Based Micromembranes, IEEE Sensors Journal, vol.8, issue.3, p.210, 2008. ,
DOI : 10.1109/JSEN.2007.913021
URL : https://hal.archives-ouvertes.fr/hal-00360093
Fabrication and characterization of PZT thin films for micromotors, Integrated Ferroelectrics, vol.11, issue.1-4, pp.213-220, 1995. ,
DOI : 10.1063/1.341027
Determination of the d31 piezoelectric coefficient of PbZrxTi1???xO3 thin films using multilayer buckled micromembranes, Journal of Applied Physics, vol.100, issue.5, pp.54908-54908, 2006. ,
DOI : 10.1063/1.2338139
URL : https://hal.archives-ouvertes.fr/hal-00130888
Sensors and Actuators A: Physical, pp.83-91, 1991. ,
Strain gauge technology, 1992. ,
Piezoresistive Microphone Design Pareto Optimization: Tradeoff Between Sensitivity and Noise Floor, Journal of Microelectromechanical Systems, vol.15, issue.6, pp.1632-1643, 2006. ,
DOI : 10.1109/JMEMS.2006.883884
Monolithic CMOS multi-transducer gas sensor microsystem for organic and inorganic analytes, Sensors and Actuators B: Chemical, vol.126, issue.2, pp.431-440, 2007. ,
DOI : 10.1016/j.snb.2007.03.035
FREE VIBRATIONS OF CIRCULAR PLATES COUPLED WITH LIQUIDS: REVISING THE LAMB PROBLEM, Journal of Fluids and Structures, vol.10, issue.7, pp.743-761, 1996. ,
DOI : 10.1006/jfls.1996.0051
Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope, Journal of Applied Physics, vol.84, issue.1, p.64, 1998. ,
DOI : 10.1063/1.368002
Effectiveness of polycrystalline silicon diffusion sources, Applied Physics Letters, vol.43, issue.10, p.960, 1983. ,
DOI : 10.1063/1.94166
layers in silicon by thermal diffusion of boron and by subsequent rapid thermal annealing, Applied Physics Letters, vol.58, issue.16, p.1748, 1991. ,
DOI : 10.1063/1.105104
A Comprehensive Study of Thin Rapid Thermal Oxide Films, Japanese Journal of Applied Physics, vol.32, issue.Part 1, No. 12A, pp.5805-5812, 1993. ,
DOI : 10.1143/JJAP.32.5805
Laser Doppler vibrometry for evaluating the piezoelectric coefficient d33 on thin film, Review of Scientific Instruments, vol.77, issue.9, p.93905, 2006. ,
DOI : 10.1063/1.2349605
Epitaxial ferroelectric Pb(Zr,???Ti)O3 thin films on Si using SrTiO3 template layers, Applied Physics Letters, vol.80, issue.1, p.97, 2002. ,
DOI : 10.1063/1.1428413
Size effect in mesoscopic epitaxial ferroelectric structures: Increase of piezoelectric response with decreasing feature size, Applied Physics Letters, vol.80, issue.17, p.3195, 2002. ,
DOI : 10.1063/1.1475369
Piezoelectric Ceramics, Journal of the American Ceramic Society, vol.36, issue.11, 1971. ,
DOI : 10.1143/JPSJ.7.333
3D measurement of micromechanical devices vibration mode shapes with a stroboscopic interferometric microscope, Optics and Lasers in Engineering, vol.36, issue.2, pp.77-101, 2001. ,
DOI : 10.1016/S0143-8166(01)00040-9
Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007. ,
Stress-based vapor sensing using resonant microbridges, Applied Physics Letters, vol.96, issue.16, p.163503, 2010. ,
DOI : 10.1063/1.3393999
On the Vibrations of an Elastic Plate in Contact with Water, Proceedings of the royal society of London, pp.205-216, 1920. ,
DOI : 10.1098/rspa.1920.0064
Micromachined piezoelectric membranes with high nominal quality factors in newtonian liquid media: A Lamb's model validation at the microscale, Sensors and Actuators B: Chemical, vol.123, issue.2, pp.860-868, 2007. ,
DOI : 10.1016/j.snb.2006.10.048
FREE VIBRATIONS OF CIRCULAR PLATES COUPLED WITH LIQUIDS: REVISING THE LAMB PROBLEM, Journal of Fluids and Structures, vol.10, issue.7, pp.743-761, 1996. ,
DOI : 10.1006/jfls.1996.0051
Weighing of biomolecules, single cells and single nanoparticles in fluid, Nature, vol.442, issue.7139, pp.1066-1069, 2007. ,
DOI : 10.1038/nature05741
ETH -SURFACE -Quartz Crystal Microbalance Technique (QCM) with Dissipation Monitoring Changes of both Adsorbed Mass and of Viscoelastic Properties of Adlayer ,
Steric Crowding Effects on Target Detection in an Affinity Biosensor, Langmuir, vol.23, issue.10, pp.5817-5823, 2007. ,
DOI : 10.1021/la063659c
Molecular Recognition between Genetically Engineered Streptavidin and Surface-Bound Biotin, Journal of the American Chemical Society, vol.121, issue.27, pp.6469-6478, 1999. ,
DOI : 10.1021/ja983984p
-poly(ethylene glycol):?? A Novel Polymeric Interface for Bioaffinity Sensing, Langmuir, vol.18, issue.1, pp.220-230, 2002. ,
DOI : 10.1021/la010913m
URL : https://hal.archives-ouvertes.fr/hal-00309089
Parallel acoustic detection of biological warfare agents surrogates by means of piezoelectric immunochips, Sensors and Actuators B: Chemical, vol.138, issue.2, pp.532-538, 2009. ,
DOI : 10.1016/j.snb.2009.02.060
URL : https://hal.archives-ouvertes.fr/hal-00406164
ADN Acide Desoxyribo-Nucléique AGB Agent de Guerre Biologique APTES 3-aminopropyltriethoxysilane ARN Acide Ribo-Nucléique Bdf Bruit de fond biologique CABT Convention sur l'interdiction des Armes Biologiques et Toxicologiques CDNBC Centre de Défense Nucléaire Biologique et Chimique CEB Centre d'Etudes du Bouchet CpGV virus Cydia pomonella Granulosis DGA/MRIS Délégation Générale de l'Armement / Mission pour la Recherche et l'Innovation ,
ADC Analog-to-Digital Converter Convertisseur Analogique-Numérique AFM Atomic Force Microscopy Microscopie à Force Atomique APDS Autonomous Pathogen Detection System Système Autonome de Détection de Pathogènes BAWS Biological Agent Warning Sensor Capteur d'Alerte d'Agents Biologiques BIDS Biological Integrated Detection System Système de Détection Biologique Intégré BOD Biochemical Oxygen Demand Demande Biochimique en Oxygène BSA Bovin Serum Albumin Albumine Sérique de Bovin CBDP Chemical and Biological Defense Program Programme de Défense Biologique et Chimique CCD Charge-Coupled Device Capteur photographique CDC Center for Disease Control Centre de Contrôle des Maladies (USA) DARPA Defense Advanced ,
1 : Graphe du bilan des forces à l'encastrement de la membrane pour un rayon global donné (trait plein) comparé au seuil critique de flambement de la structure, p.5 ,
Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007. ,
Phosphate Buffer Saline (tampon phosphate salé), composition : NaCl 137 mM ; KCl 3 mM ,
Electronic scheme for multiplexed dynamic behavior excitation and detection of piezoelectric silicon-based micromembranes, IEEE of Sensors Journal, vol.8, issue.1, p.210, 2007. ,
Silicon-based micromembranes with piezoelectric actuation and piezoresistive detection for sensing purposes in liquid media, Journal of Micromechanics and Microengineering, vol.20, issue.7, p.7, 2010. ,
DOI : 10.1088/0960-1317/20/7/075014
URL : https://hal.archives-ouvertes.fr/hal-00549532
Applied Physics Letters, accepted for publication Conférences internationales à comité de lecture: 1. Electrical equivalent circuit for air and liquid characterization of a multilayer micromembrane with piezoelectric actuation and read-out capabilities, NSTI Nanotechnology Conference and Trade Show, 2007. ,
Investigation of molecularly imprinted polymers to detect proteins by an integrated, autonomous piezoelectric micromembrane platform, MicroTAS Conference, 2009. ,
MEMS-based multisensors platform with piezoelectric actuation and piezoresistive readout capabilities for biosensing applications, Biosensors, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00574487
Resonating BioMEMS with integrated actuation and sensing for Biodefense applications, Conférences nationales : 1 Journées Nationales du GDR Micro et Nano structures, 2009. ,