U. Manchester, S. Kingdom, K. Tonev, C. Kanev, R. Dishovsky et al., non-proliferation.irsn.fr The Black Death Medical management of Chemical and Biological Casualties The silent weapons Harris, Factories of Death: Japanese Biological Warfare, 1932-45, and the American Cover-Up International Humanitarian Law -Protocole de Genève 1925 Convention on the Prohibition of the Development, Production and Stockpiling of Bacteriological (Biological) and Toxin Weapons and on Their Destruction Contrôle de l'interdiction des armes biologiques : un état des lieux, IRSN -Institut de radioprotection et de sûreté nucléaire Sofia, Bulgaria. [4], 1968.

E. G. Lake, Analyzing The Anthrax Attacks, 2005.

D. Raoult, Chemical and Biological Defense Defense Threat Reduction Agency, www.dtra.mil [16 Mission and Vision of the Joint Program Executive Office for Chemical and Biological Defense Chemical and Biological Defense Program, 19] A.F. Collings et F. Caruso, Reports on Progess in Physics, 1997.

S. J. Updike and G. P. Hicks, The Enzyme Electrode, Nature, vol.18, issue.5092, pp.986-988, 1967.
DOI : 10.1021/ac60238a014

J. H. Luong, K. B. Male, and J. D. Glennon, Biosensor technology: Technology push versus market pull, Biotechnology Advances, vol.26, issue.5, pp.492-500, 2008.
DOI : 10.1016/j.biotechadv.2008.05.007

K. Haupt, K. Noworyta, and E. W. Kutner, Imprinted polymer-based enantioselective acoustic sensor using a quartz crystal microbalance, Analytical Communications, vol.326, issue.11-12, pp.391-393, 1999.
DOI : 10.1039/a907844d

T. H. Rider, A B Cell-Based Sensor for Rapid Identification of Pathogens, Science, vol.301, issue.5630, pp.213-215, 2003.
DOI : 10.1126/science.1084920

L. C. Clark and C. Lyons, ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY, Annals of the New York Academy of Sciences, vol.12, issue.2, pp.29-45, 1962.
DOI : 10.1111/j.1749-6632.1962.tb13623.x

L. D. Mello and L. T. Kubota, Review of the use of biosensors as analytical tools in the food and drink industries, Food Chemistry, vol.77, issue.2, pp.237-256, 2002.
DOI : 10.1016/S0308-8146(02)00104-8

H. Nakamura and I. Karube, Current research activity in biosensors, Analytical and Bioanalytical Chemistry, vol.377, issue.3, pp.446-468, 2003.
DOI : 10.1007/s00216-003-1947-5

Y. Nomura, G. Chee, and E. I. Karube, Biosensor technology for determination of BOD, Field Analytical Chemistry & Technology, vol.2, issue.6, pp.333-340, 1999.
DOI : 10.1002/(SICI)1520-6521(1998)2:6<333::AID-FACT3>3.0.CO;2-0

K. Nakanishi, K. Ikebukuro, and I. Karube, Determination of cyanide using a microbial sensor, Applied Biochemistry and Biotechnology, vol.13, issue.3, pp.97-106, 1996.
DOI : 10.1007/BF02788064

S. Centi, S. Laschi, M. Fránek, and E. M. Mascini, A disposable immunomagnetic electrochemical sensor based on functionalised magnetic beads and carbon-based screen-printed electrodes (SPCEs) for the detection of polychlorinated biphenyls (PCBs), Analytica Chimica Acta, vol.538, issue.1-2, pp.205-212, 2005.
DOI : 10.1016/j.aca.2005.01.073

K. A. Joshi, J. Tang, R. Haddon, J. Wang, W. Chen et al., A Disposable Biosensor for Organophosphorus Nerve Agents Based on Carbon Nanotubes Modified Thick Film Strip Electrode, Electroanalysis, vol.288, issue.1, pp.54-58, 2005.
DOI : 10.1002/elan.200403118

J. Ye, S. V. Leichter, and A. G. Rand, Piezoelectric Biosensor for Detection of Salmonella typhimurium, Journal of Food Science, vol.57, issue.3, pp.1067-1086, 1997.
DOI : 10.1111/j.1365-2621.1997.tb15039.x

S. T. Pathirana, J. Barbaree, B. A. Chin, M. G. Hartell, W. C. Neely et al., Rapid and sensitive biosensor for Salmonella, Biosensors and Bioelectronics, vol.15, issue.3-4, pp.135-141, 2000.
DOI : 10.1016/S0956-5663(00)00067-1

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.596.4799

E. Gizeli and C. R. Lowe, Biomolecular sensors, 2002.

M. Madou and M. Tierney, Required technology breakthroughs to assume widely accepted biosensors, Applied Biochemistry and Biotechnology, vol.22, issue.No. 4, pp.109-128, 1993.
DOI : 10.1007/BF02918537

S. L. Barker, R. Kopelman, T. E. Meyer, and M. A. Cusanovich, Fiber-Optic Nitric Oxide-Selective Biosensors and Nanosensors, Analytical Chemistry, vol.70, issue.5, pp.971-976, 1998.
DOI : 10.1021/ac970706k

H. Aoki, P. Bühlmann, and Y. Umezawa, Electrochemical Detection of a One-Base Mismatch in an Oligonucleotide Using Ion-Channel Sensors with Self-Assembled PNA Monolayers, Electroanalysis, vol.4, issue.16, pp.1272-1276, 2000.
DOI : 10.1002/1521-4109(200011)12:16<1272::AID-ELAN1272>3.0.CO;2-F

H. A. Hartley and A. J. Baeumner, Biosensor for the specific detection of a single viable B.??anthracis spore, Analytical and Bioanalytical Chemistry, vol.282, issue.3, pp.319-327, 2003.
DOI : 10.1016/S0956-5663(02)00162-8

P. A. Emanuel, R. Bell, J. L. Dang, R. Mcclanahan, J. C. David et al., Detection of Francisella tularensis within Infected Mouse Tissues by Using a Hand-Held PCR Thermocycler, Journal of Clinical Microbiology, vol.41, issue.2, pp.689-693, 2003.
DOI : 10.1128/JCM.41.2.689-693.2003

J. A. Higgins, S. Nasarabadi, J. S. Karns, D. R. Shelton, M. Cooper et al., A handheld real time thermal cycler for bacterial pathogen detection, Biosensors and Bioelectronics, vol.18, issue.9, pp.1115-1123, 2003.
DOI : 10.1016/S0956-5663(02)00252-X

J. A. Higgins, M. S. Ibrahim, F. K. Knauert, G. V. Ludwig, T. M. Kijek et al., Sensitive and Rapid Identification of Biological Threat Agents, Annals of the New York Academy of Sciences, vol.162, issue.1 FOOD AND AGRI, pp.130-148, 2000.
DOI : 10.1001/jama.278.5.428

E. Benjamini, S. Leskowitz, and G. H. Sunshine, Immunology: a short course, 2000.

A. Kim, C. S. Ah, H. Y. Yu, J. Yang, I. Baek et al., Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors, Applied Physics Letters, vol.91, issue.10, p.103901, 2007.
DOI : 10.1063/1.2779965

S. T. Pathirana, J. Barbaree, B. A. Chin, M. G. Hartell, W. C. Neely et al., Rapid and sensitive biosensor for Salmonella, Biosensors and Bioelectronics, vol.15, issue.3-4, pp.135-141, 2000.
DOI : 10.1016/S0956-5663(00)00067-1

T. M. Peduru-hewa, G. A. Tannock, D. E. Mainwaring, S. Harrison, and J. V. Fecondo, The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance, Journal of Virological Methods, vol.162, issue.1-2, pp.14-21, 2009.
DOI : 10.1016/j.jviromet.2009.07.001

J. J. Gooding, Biosensor technology for detecting biological warfare agents: Recent progress and future trends, Analytica Chimica Acta, vol.559, issue.2, pp.137-151, 2006.
DOI : 10.1016/j.aca.2005.12.020

B. Lu, M. R. Smyth, and R. O. Kennedy, The Analyst, pp.29-32, 1996.

P. Schuck, USE OF SURFACE PLASMON RESONANCE TO PROBE THE EQUILIBRIUM AND DYNAMIC ASPECTS OF INTERACTIONS BETWEEN BIOLOGICAL MACROMOLECULES, Annual Review of Biophysics and Biomolecular Structure, vol.26, issue.1, pp.541-566, 1997.
DOI : 10.1146/annurev.biophys.26.1.541

K. Catt, G. Tregear, H. Burger, and C. Skermer, Antibody-coated tube method for radioimmunoassay of human growth hormone, Clinica Chimica Acta, vol.27, issue.2, pp.267-279, 1970.
DOI : 10.1016/0009-8981(70)90344-X

J. E. Zull, J. Reed-mundell, Y. W. Lee, D. Vezenov, N. P. Ziats et al., Problems and approaches in covalent attachment of peptides and proteins to inorganic surfaces for biosensor applications, Journal of Industrial Microbiology, vol.1, issue.3, pp.137-143, 1994.
DOI : 10.1007/BF01583997

A. Cerf and C. Vieu, Nanopatterning at the Service of Single Molecule Assays, Biophysical Journal, vol.98, issue.3, p.758, 2010.
DOI : 10.1016/j.bpj.2009.12.4163

G. J. Leggett, C. J. Roberts, P. M. Williams, M. C. Davies, D. E. Jackson et al., Approaches to the immobilization of proteins at surfaces for analysis by scanning tunneling microscopy, Langmuir, vol.9, issue.9, pp.2356-2362, 1993.
DOI : 10.1021/la00033a018

J. Wang, L. M. Frostman, and M. D. Ward, Self-assembled thiol monolayers with carboxylic acid functionality: measuring pH-dependent phase transitions with the quartz crystal microbalance, The Journal of Physical Chemistry, vol.96, issue.13, pp.5224-5228, 1992.
DOI : 10.1021/j100192a010

Y. T. Kim, R. L. Mccarley, and A. J. Bard, Observation of n-octadecanethiol multilayer formation from solution onto gold, Langmuir, vol.9, issue.8, pp.1941-1944, 1993.
DOI : 10.1021/la00032a001

V. Silin, H. Weetall, and D. J. Vanderah, SPR Studies of the Nonspecific Adsorption Kinetics of Human IgG and BSA on Gold Surfaces Modified by Self-Assembled Monolayers (SAMs), Journal of Colloid and Interface Science, vol.185, issue.1, pp.94-103, 1997.
DOI : 10.1006/jcis.1996.4586

J. Benesch, S. Svedhem, S. C. Svensson, R. Valiokas, B. Liedberg et al., Protein adsorption to oligo(ethylene glycol) self-assembled monolayers: Experiments with fibrinogen, heparinized plasma, and serum, Journal of Biomaterials Science, Polymer Edition, vol.9, issue.1, pp.581-597, 2001.
DOI : 10.1163/156856201316883421

A. Ulman, An Introduction to Ultrathin Organic Films from Langmuir?Blodgett to Self- Assembly, 1991.

G. P. Anderson, J. P. Golden, and F. S. Ligler, A fiber optic biosensor: combination tapered fibers designed for improved signal acquisition, Biosensors and Bioelectronics, vol.8, issue.5, pp.249-256, 1993.
DOI : 10.1016/0956-5663(93)80012-E

M. J. Stevens, Thoughts on the Structure of Alkylsilane Monolayers, Langmuir, vol.15, issue.8, pp.2773-2778, 1999.
DOI : 10.1021/la981064e

A. Manz, N. Graber, and H. Widmer, Miniaturized total chemical analysis systems: A novel concept for chemical sensing, Sensors and Actuators B: Chemical, vol.1, issue.1-6, pp.244-248, 1990.
DOI : 10.1016/0925-4005(90)80209-I

D. R. Reyes, D. Iossifidis, P. A. Auroux, and A. Manz, Micro Total Analysis Systems. 1. Introduction, Theory, and Technology, Analytical Chemistry, vol.74, issue.12, pp.2623-2636, 2002.
DOI : 10.1021/ac0202435

B. G. Jongerius-gortemaker, R. L. Goverde, F. Van-knapen, and E. A. Bergwerff, Surface plasmon resonance (BIACORE) detection of serum antibodies against Salmonella enteritidis and Salmonella typhimurium, Journal of Immunological Methods, vol.266, issue.1-2, pp.33-44, 2002.
DOI : 10.1016/S0022-1759(02)00102-3

B. L. Frey, C. E. Jordan, S. Kornguth, and R. M. Corn, Control of the Specific Adsorption of Proteins onto Gold Surfaces with Poly(L-lysine) Monolayers, Analytical Chemistry, vol.67, issue.24, pp.4452-4457, 1995.
DOI : 10.1021/ac00120a003

N. P. Huang, R. Michel, J. Voros, M. Textor, R. Hofer et al., -poly(ethylene glycol) Layers on Metal Oxide Surfaces:?? Surface-Analytical Characterization and Resistance to Serum and Fibrinogen Adsorption, Langmuir, vol.17, issue.2, pp.489-498, 2001.
DOI : 10.1021/la000736+

URL : https://hal.archives-ouvertes.fr/hal-00309089

N. Huang, J. Vörös, S. M. De-paul, M. Textor, and N. D. Spencer, -poly(ethylene glycol):?? A Novel Polymeric Interface for Bioaffinity Sensing, Langmuir, vol.18, issue.1, pp.220-230, 2002.
DOI : 10.1021/la010913m

URL : https://hal.archives-ouvertes.fr/hal-00309089

A. Hucknall, S. Rangarajan, and A. Chilkoti, In Pursuit of Zero: Polymer Brushes that Resist the Adsorption of Proteins, Advanced Materials, vol.260, issue.23, pp.2441-2446, 2009.
DOI : 10.1002/adma.200803125

H. Ma, J. Hyun, P. Stiller, and A. Chilkoti, ???Non-Fouling??? Oligo(ethylene glycol)- Functionalized Polymer Brushes Synthesized by Surface-Initiated Atom Transfer Radical Polymerization, Advanced Materials, vol.16, issue.4, pp.338-341, 2004.
DOI : 10.1002/adma.200305830

H. Kar??layan, I. Hemmilä, H. Takalo, A. Toivonen, K. Pettersson et al., Influence of Coupling Method on the Luminescence Properties, Coupling Efficiency, and Binding Affinity of Antibodies Labeled with Europium(III) Chelates, Bioconjugate Chemistry, vol.8, issue.1, pp.71-75, 1997.
DOI : 10.1021/bc960075l

S. H. Snyder, J. Axelrod, and M. Zweig, A sensitive and specific fluorescence assay for tissue serotonin, Biochemical Pharmacology, vol.14, issue.5, pp.831-835, 1965.
DOI : 10.1016/0006-2952(65)90102-4

G. Ramsay, DNA chips: State-of-the art, Nature Biotechnology, vol.2, issue.31, pp.40-44, 1998.
DOI : 10.1006/geno.1996.0219

C. Taitt, J. P. Golden, Y. S. Shubin, L. C. Shriver-lake, K. E. Sapsford et al., A Portable Array Biosensor for Detecting Multiple Analytes in Complex Samples, Microbial Ecology, vol.47, issue.2, pp.175-185, 2004.
DOI : 10.1007/s00248-003-1011-1

K. Brogan and D. Walt, Optical fiber-based sensors: application to chemical biology, Current Opinion in Chemical Biology, vol.9, issue.5, pp.494-500, 2005.
DOI : 10.1016/j.cbpa.2005.08.009

A. Brandenburg, F. Curdt, G. Sulz, F. Ebling, J. Nestler et al., Biochip readout system for point-of-care applications, Sensors and Actuators B: Chemical, vol.139, issue.1, pp.245-251, 2009.
DOI : 10.1016/j.snb.2009.02.052

G. P. Anderson and C. A. Rowe-taitt, RAPTOR: A portable, automated biosensor, Proceedings of the First Conference on Point Detection for Chemical and Biological Defense, 2000.

G. Anderson, R. Matney, J. Liu, A. Hayhurst, and E. Goldman, Multiplexed fluid array screening of phage displayed anti-ricin single domain antibodies for rapid assessment of specificity, BioTechniques, vol.43, issue.6, pp.806-811, 2007.
DOI : 10.2144/000112600

C. Striebel, A. Brecht, and G. Gauglitz, Characterization of biomembranes by spectral ellipsometry, surface plasmon resonance and interferometry with regard to biosensor application, Biosensors and Bioelectronics, vol.9, issue.2, pp.139-146, 1994.
DOI : 10.1016/0956-5663(94)80105-3

A. Otto, Zeitschrift für Physik A Hadrons and Nuclei, pp.398-410, 1968.

T. M. Chinowsky, J. G. Quinn, D. U. Bartholomew, R. Kaiser, and J. L. Elkind, Performance of the Spreeta 2000 integrated surface plasmon resonance affinity sensor, Sensors and Actuators B: Chemical, vol.91, issue.1-3, pp.266-274, 2003.
DOI : 10.1016/S0925-4005(03)00113-8

A. N. Naimushin, S. D. Soelberg, D. K. Nguyen, L. Dunlap, D. Bartholomew et al., Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor, Biosensors and Bioelectronics, vol.17, issue.6-7, pp.573-584, 2002.
DOI : 10.1016/S0956-5663(02)00014-3

M. Pohanka, P. Skládal, and M. Kroèa, Biosensors for Biological Warfare Agent Detection, Defence Science Journal, vol.57, issue.3, pp.185-193, 2007.
DOI : 10.14429/dsj.57.1760

V. K. Rao, G. P. Rai, G. S. Agarwal, and S. Suresh, Amperometric immunosensor for detection of antibodies of Salmonella typhi in patient serum, Analytica Chimica Acta, vol.531, issue.2, pp.173-177, 2005.
DOI : 10.1016/j.aca.2004.10.015

B. Wang, B. Li, Q. Deng, and S. Dong, Amperometric Glucose Biosensor Based on Sol???Gel Organic???Inorganic Hybrid Material, Analytical Chemistry, vol.70, issue.15, pp.3170-3174, 1998.
DOI : 10.1021/ac980160h

C. Ercole, M. D. Gallo, M. Pantalone, S. Santucci, L. Mosiello et al., A biosensor for Escherichia coli based on a potentiometric alternating biosensing (PAB) transducer, Sensors and Actuators B: Chemical, vol.83, issue.1-3, pp.48-52, 2002.
DOI : 10.1016/S0925-4005(01)01027-9

M. Niu, X. Ding, and Q. Tong, Effect of two types of surface sites on the characteristics of Si3N4-gate pH-ISFETs, Sensors and Actuators B: Chemical, vol.37, issue.1-2, pp.13-17, 1996.
DOI : 10.1016/S0925-4005(97)80067-6

T. Mikolajick, R. Kühnhold, and H. , The pH-sensing properties of tantalum pentoxide films fabricated by metal organic low pressure chemical vapor deposition, Sensors and Actuators B: Chemical, vol.44, issue.1-3, pp.262-267, 1997.
DOI : 10.1016/S0925-4005(97)00166-4

J. Chiang, S. Jan, J. Chou, and Y. Chen, Study on the temperature effect, hysteresis and drift of pH-ISFET devices based on amorphous tungsten oxide, Sensors and Actuators B: Chemical, vol.76, issue.1-3, pp.624-628, 2001.
DOI : 10.1016/S0925-4005(01)00657-8

M. L. Pourciel-gouzy, W. Sant, I. Humenyuk, L. Malaquin, X. Dollat et al., Development of pH-ISFET sensors for the detection of bacterial activity, Sensors and Actuators B: Chemical, vol.103, issue.1-2, pp.247-251, 2004.
DOI : 10.1016/j.snb.2004.04.056

Y. Cui, Q. Wei, H. Park, and C. M. Lieber, Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species, Science, vol.293, issue.5533, pp.1289-1292, 2001.
DOI : 10.1126/science.1062711

X. Wang, S. V. Dzyadevych, J. Chovelon, N. J. Renault, L. Chen et al., Development of a conductometric nitrate biosensor based on Methyl viologen/Nafion?? composite film, Electrochemistry Communications, vol.8, issue.2, pp.201-205, 2006.
DOI : 10.1016/j.elecom.2005.11.006

URL : https://hal.archives-ouvertes.fr/hal-00141454

R. Bhatia, J. W. Dilleen, A. L. Atkinson, and D. M. Rawson, Combined physico-chemical and biological sensing in environmental monitoring, Biosensors and Bioelectronics, vol.18, issue.5-6, pp.667-674, 2003.
DOI : 10.1016/S0956-5663(03)00012-5

W. G. Cady, Piezoelectricity: An Introduction to the Theory and Applications of Electromechanical Phenomena in Crystals, 1964.

M. Bisoffi, B. Hjelle, D. Brown, D. Branch, T. Edwards et al., Detection of viral bioagents using a shear horizontal surface acoustic wave biosensor, Biosensors and Bioelectronics, vol.23, issue.9, pp.1397-1403, 2008.
DOI : 10.1016/j.bios.2007.12.016

K. Korsah and C. L. Ma, Harmonic frequency analysis of SAW resonator chemical sensors: application to the detection of carbon dioxide and humidity1Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by Lockheed Martin Energy Research Corporation for the US Department of Energy under Contract No. DE-AC05-96OR22464.1, Sensors and Actuators B: Chemical, vol.50, issue.2, pp.110-116, 1998.
DOI : 10.1016/S0925-4005(98)00163-4

G. Sauerbrey, Verwendung von Schwingquarzen zur W???gung d???nner Schichten und zur Mikrow???gung, Zeitschrift f???r Physik, vol.155, issue.2, pp.206-222, 1959.
DOI : 10.1007/BF01337937

C. T. Kirk and E. E. Huber, The oxidation of aluminum films in low-pressure oxygen atmospheres, Surface Science, vol.9, issue.2, pp.217-245, 1968.
DOI : 10.1016/0039-6028(68)90174-X

M. V. Voinova, M. Rodahl, M. Jonson, and E. B. Kasemo, Viscoelastic Acoustic Response of Layered Polymer Films at Fluid-Solid Interfaces: Continuum Mechanics Approach, Physica Scripta, vol.59, issue.5, pp.391-396, 1999.
DOI : 10.1238/Physica.Regular.059a00391

C. D. Corso, D. D. Stubbs, S. H. Lee, M. Goggins, R. H. Hruban et al., Real-time detection of mesothelin in pancreatic cancer cell line supernatant using an acoustic wave immunosensor, Cancer Detection and Prevention, vol.30, issue.2, pp.180-187, 2006.
DOI : 10.1016/j.cdp.2006.03.004

L. Wang, C. Wu, Z. Hu, Y. Zhang, R. Li et al., Sensing Escherichia coli O157:H7 via frequency shift through a self-assembled monolayer based QCM immunosensor, Journal of Zhejiang University SCIENCE B, vol.9, issue.2, pp.121-131, 2008.
DOI : 10.1631/jzus.B0710307

F. Höök, B. Kasemo, T. Nylander, C. Fant, K. Sott et al., Variations in Coupled Water, Viscoelastic Properties, and Film Thickness of a Mefp-1 Protein Film during Adsorption and Cross-Linking:?? A Quartz Crystal Microbalance with Dissipation Monitoring, Ellipsometry, and Surface Plasmon Resonance Study, Analytical Chemistry, vol.73, issue.24, pp.5796-5804, 2001.
DOI : 10.1021/ac0106501

R. Hao, D. Wang, X. Zhang, G. Zuo, H. Wei et al., Rapid detection of Bacillus anthracis using monoclonal antibody functionalized QCM sensor, Biosensors and Bioelectronics, vol.24, issue.5, pp.1330-1335, 2009.
DOI : 10.1016/j.bios.2008.07.071

H. Wang, Y. Liu, Y. Yang, T. Deng, G. Shen et al., A protein A-based orientation-controlled immobilization strategy for antibodies using nanometer-sized gold particles and plasma-polymerized film, Analytical Biochemistry, vol.324, issue.2, pp.219-226, 2004.
DOI : 10.1016/j.ab.2003.09.032

T. W. Owen, R. O. Al-kaysi, C. J. Bardeen, and Q. Cheng, Microgravimetric immunosensor for direct detection of aerosolized influenza A virus particles, Sensors and Actuators B: Chemical, vol.126, issue.2, pp.691-699, 2007.
DOI : 10.1016/j.snb.2007.04.028

H. C. Nathanson, W. E. Newell, R. A. Wickstrom, and J. R. Davis-jr, The resonant gate transistor, IEEE Transactions on Electron Devices, vol.14, issue.3, pp.117-133, 1967.
DOI : 10.1109/T-ED.1967.15912

R. Bashir, BioMEMS: state-of-the-art in detection, opportunities and prospects, Advanced Drug Delivery Reviews, vol.56, issue.11, pp.1565-1586, 2004.
DOI : 10.1016/j.addr.2004.03.002

N. Bioelectronics-elsevier, C. Tsai, and . Sue, Biosensors, Sensors and Actuators A: Physical, vol.134, pp.555-564, 2007.

J. H. Prescott, S. Lipka, S. Baldwin, N. F. Sheppard, J. M. Maloney et al., Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device, Nature Biotechnology, vol.5, issue.4, pp.437-438, 2006.
DOI : 10.1038/nbt1199

A. Nisar, N. Afzulpurkar, B. Mahaisavariya, and A. Tuantranont, MEMS-based micropumps in drug delivery and biomedical applications, Sensors and Actuators B: Chemical, vol.130, issue.2, pp.917-942, 2008.
DOI : 10.1016/j.snb.2007.10.064

K. W. Oh and C. H. Ahn, A review of microvalves, Journal of Micromechanics and Microengineering, vol.16, issue.5, p.13, 2006.
DOI : 10.1088/0960-1317/16/5/R01

B. Bhushan, Nanotribology and nanomechanics of MEMS/NEMS and BioMEMS/BioNEMS materials and devices, Microelectronic Engineering, vol.84, issue.3, pp.387-412, 2007.
DOI : 10.1016/j.mee.2006.10.059

D. B. Serrell, J. Law, A. J. Slifka, R. L. Mahajan, and D. S. Finch, A uniaxial bioMEMS device for imaging single cell response during quantitative force-displacement measurements, Biomedical Microdevices, vol.109, issue.Pt 17, pp.883-889, 2008.
DOI : 10.1007/s10544-008-9202-7

P. A. Janmey and C. A. Mcculloch, Cell Mechanics: Integrating Cell Responses to Mechanical Stimuli, Annual Review of Biomedical Engineering, vol.9, issue.1, pp.1-34, 2007.
DOI : 10.1146/annurev.bioeng.9.060906.151927

S. Bhattacharya, J. Jang, L. Yang, D. Akin, and R. Bashir, BIOMEMS AND NANOTECHNOLOGY-BASED APPROACHES FOR RAPID DETECTION OF BIOLOGICAL ENTITIES, Journal of Rapid Methods and Automation in Microbiology, vol.2, issue.3, pp.1-32, 2007.
DOI : 10.1016/S0003-2670(97)00560-6

G. Binnig, C. F. Quate, and C. Gerber, Atomic Force Microscope, Physical Review Letters, vol.56, issue.9, p.930, 1986.
DOI : 10.1103/PhysRevLett.56.930

G. G. Stoney, The Tension of Metallic Films Deposited by Electrolysis, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, vol.82, issue.553, pp.172-175, 1909.
DOI : 10.1098/rspa.1909.0021

M. Yue, J. C. Stachowiak, H. Lin, R. Datar, R. Cote et al., Label-Free Protein Recognition Two-Dimensional Array Using Nanomechanical Sensors, Nano Letters, vol.8, issue.2, pp.520-524, 2008.
DOI : 10.1021/nl072740c

H. P. Lang, R. Berger, C. Andreoli, J. Brugger, M. Despont et al., Sequential position readout from arrays of micromechanical cantilever sensors, Applied Physics Letters, vol.72, issue.3, p.383, 1998.
DOI : 10.1063/1.120749

G. Shekhawat, S. Tark, and V. P. Dravid, MOSFET-Embedded Microcantilevers for Measuring Deflection in Biomolecular Sensors, Science, vol.311, issue.5767, pp.1592-1595, 2006.
DOI : 10.1126/science.1122588

A. Boisen, J. Thaysen, H. Jensenius, and O. Hansen, Environmental sensors based on micromachined cantilevers with integrated read-out, Ultramicroscopy, vol.82, issue.1-4, pp.11-16, 2000.
DOI : 10.1016/S0304-3991(99)00148-5

R. Lakhmi, H. Debeda, I. Dufour, and C. Lucat, Force Sensors Based on Screen-Printed Cantilevers, IEEE Sensors Journal, vol.10, issue.6, pp.1133-1137, 2010.
DOI : 10.1109/JSEN.2010.2040387

URL : https://hal.archives-ouvertes.fr/hal-00453483

S. Heinrich, M. Wenzel, F. Josse, and I. Dufour, An analytical model for transient deformation of viscoelastically coated beams: Applications to static-mode microcantilever chemical sensors, Journal of Applied Physics, vol.105, issue.12, p.124903, 2009.
DOI : 10.1063/1.3148291

URL : https://hal.archives-ouvertes.fr/hal-00383067

T. Müller, M. Brandl, O. Brand, and H. Baltes, An industrial CMOS process family adapted for the fabrication of smart silicon sensors, Sensors and Actuators A: Physical, vol.84, issue.1-2, pp.126-133, 2000.
DOI : 10.1016/S0924-4247(99)00348-9

C. A. Savran, T. P. Burg, J. Fritz, and S. R. Manalis, Microfabricated mechanical biosensor with inherently differential readout, Applied Physics Letters, vol.83, issue.8, p.1659, 2003.
DOI : 10.1063/1.1605238

B. Ilic, S. Krylov, and H. G. Craighead, Theoretical and experimental investigation of optically driven nanoelectromechanical oscillators, Journal of Applied Physics, vol.107, issue.3, p.34311, 2010.
DOI : 10.1063/1.3305464

L. Han and S. Chen, Wireless bimorph micro-actuators by pulsed laser heating, Sensors and Actuators A: Physical, vol.121, issue.1, pp.35-43, 2005.
DOI : 10.1016/j.sna.2004.12.012

D. Lange, C. Hagleitner, C. Herzog, O. Brand, and H. Baltes, Electromagnetic actuation and MOS-transistor sensing for CMOS-integrated micromechanical resonators, Sensors and Actuators A: Physical, vol.103, issue.1-2, pp.150-155, 2003.
DOI : 10.1016/S0924-4247(02)00307-2

D. R. Southworth, H. G. Craighead, and J. M. Parpia, Pressure dependent resonant frequency of micromechanical drumhead resonators, Applied Physics Letters, vol.94, issue.21, p.213506, 2009.
DOI : 10.1063/1.3141731

L. Johnson, A. K. Gupta, A. Ghafoor, D. Akin, and R. Bashir, Characterization of vaccinia virus particles using microscale silicon cantilever resonators and atomic force microscopy, Sensors and Actuators B: Chemical, vol.115, issue.1, pp.189-197, 2006.
DOI : 10.1016/j.snb.2005.08.047

C. Vanc?-ura, Y. Li, J. Lichtenberg, K. U. Kirstein, A. Hierlemann et al., Liquid-Phase Chemical and Biochemical Detection Using Fully Integrated Magnetically Actuated Complementary Metal Oxide Semiconductor Resonant Cantilever Sensor Systems, Analytical Chemistry, vol.79, issue.4, pp.1646-1654, 2007.
DOI : 10.1021/ac061795g

G. A. Campbell and R. Mutharasan, Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever, Sensors and Actuators A: Physical, vol.122, issue.2, pp.326-334, 2005.
DOI : 10.1016/j.sna.2005.05.012

G. A. Campbell and R. Mutharasan, Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300spores/mL, Biosensors and Bioelectronics, vol.21, issue.9, pp.1684-1692, 2006.
DOI : 10.1016/j.bios.2005.08.001

G. A. Campbell and R. Mutharasan, Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers, Biosensors and Bioelectronics, vol.21, issue.3, pp.462-473, 2005.
DOI : 10.1016/j.bios.2004.11.009

T. P. Burg, M. Godin, S. M. Knudsen, W. Shen, G. Carlson et al., Weighing of biomolecules, single cells and single nanoparticles in fluid, Nature, vol.442, issue.7139, pp.1066-1069, 2007.
DOI : 10.1038/nature05741

M. G. Von-muhlen, N. D. Brault, S. M. Knudsen, S. Jiang, and S. R. Manalis, Label-Free Biomarker Sensing in Undiluted Serum with Suspended Microchannel Resonators, Analytical Chemistry, vol.82, issue.5, pp.1905-1910, 2010.
DOI : 10.1021/ac9027356

J. Tamayo, Study of the noise of micromechanical oscillators under quality factor enhancement via driving force control, Journal of Applied Physics, vol.97, issue.4, p.44903, 2005.
DOI : 10.1063/1.1847729

P. Muralt, A. Kholkin, M. Kohli, and T. Maeder, Piezoelectric actuation of PZT thin-film diaphragms at static and resonant conditions, Sensors and Actuators A: Physical, vol.53, issue.1-3, pp.398-404, 1996.
DOI : 10.1016/0924-4247(96)01139-9

P. Luginbuhl, S. Collins, G. Racine, M. Grétillat, N. De-rooij et al., Ultrasonic flexural Lamb-wave actuators based on PZT thin film, Sensors and Actuators A: Physical, vol.64, issue.1, pp.41-49, 1998.
DOI : 10.1016/S0924-4247(98)80056-3

Y. Xin, Z. Li, L. Odum, Z. Cheng, and E. Z. Xu, Piezoelectric diaphragm as a high performance biosensor platform, Applied Physics Letters, vol.89, issue.22, p.223508, 2006.
DOI : 10.1063/1.2396919

L. Nicu, M. Guirardel, F. Chambosse, P. Rougerie, S. Hinh et al., Resonating piezoelectric membranes for microelectromechanically based bioassay: detection of streptavidin???gold nanoparticles interaction with biotinylated DNA, Sensors and Actuators B: Chemical, vol.110, issue.1, pp.125-136, 2005.
DOI : 10.1016/j.snb.2005.01.021

URL : https://hal.archives-ouvertes.fr/hal-00130821

C. Ayela, Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007.

C. Ayela, F. Vandevelde, D. Lagrange, K. Haupt, and L. Nicu, Combining Resonant Piezoelectric Micromembranes with Molecularly Imprinted Polymers, Angewandte Chemie, vol.542, issue.48, pp.9431-9434, 2007.
DOI : 10.1002/ange.200703881

URL : https://hal.archives-ouvertes.fr/hal-00198071

C. Bergaud, L. Nicu, and A. Martinez, Multi-Mode Air Damping Analysis of Composite Cantilever Beams, Japanese Journal of Applied Physics, vol.38, issue.Part 1, No. 11, pp.6521-6525, 1999.
DOI : 10.1143/JJAP.38.6521

C. Ayela, Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007.

H. Lamb, On the Vibrations of an Elastic Plate in Contact with Water, Proceedings of the royal society of London, pp.205-216, 1920.
DOI : 10.1098/rspa.1920.0064

R. D. Blevins, Formulas for Natural Frequency and Mode Shape, Journal of Applied Mechanics, vol.47, issue.2, 1979.
DOI : 10.1115/1.3153712

V. Branger, V. Pelosin, K. F. Badawi, and P. Goudeau, Study of the mechanical and microstructural state of platinum thin films, Thin Solid Films, vol.275, issue.1-2, pp.22-24, 1996.
DOI : 10.1016/0040-6090(95)07011-7

P. Delobelle, O. Guillon, E. Fribourg-blanc, C. Soyer, E. Cattan et al., True Young modulus of Pb(Zr,Ti)O3 films measured by nanoindentation, Applied Physics Letters, vol.85, issue.22, p.5185, 2004.
DOI : 10.1063/1.1827331

URL : https://hal.archives-ouvertes.fr/hal-00141178

D. R. Southworth, L. M. Bellan, Y. Linzon, H. G. Craighead, and J. M. Parpia, Stress-based vapor sensing using resonant microbridges, Applied Physics Letters, vol.96, issue.16, p.163503, 2010.
DOI : 10.1063/1.3393999

D. L. Devoe, Thin Film Zinc Oxide Microsensors and Microactuators, thèse, 1997.

C. Ayela, T. Alava, D. Lagrange, D. Rèmiens, C. Soyer et al., Electronic Scheme for Multiplexed Dynamic Behavior Excitation and Detection of Piezoelectric Silicon-Based Micromembranes, IEEE Sensors Journal, vol.8, issue.3, p.210, 2008.
DOI : 10.1109/JSEN.2007.913021

URL : https://hal.archives-ouvertes.fr/hal-00360093

P. Muralt, A. Kholkin, M. Kohli, T. Maeder, K. G. Brooks et al., Fabrication and characterization of PZT thin films for micromotors, Integrated Ferroelectrics, vol.11, issue.1-4, pp.213-220, 1995.
DOI : 10.1063/1.341027

C. Ayela, L. Nicu, C. Soyer, E. Cattan, and C. Bergaud, Determination of the d31 piezoelectric coefficient of PbZrxTi1???xO3 thin films using multilayer buckled micromembranes, Journal of Applied Physics, vol.100, issue.5, pp.54908-54908, 2006.
DOI : 10.1063/1.2338139

URL : https://hal.archives-ouvertes.fr/hal-00130888

Y. Kanda, Sensors and Actuators A: Physical, pp.83-91, 1991.

A. L. Window, Strain gauge technology, 1992.

M. Papila, R. T. Haftka, T. Nishida, and M. Sheplak, Piezoresistive Microphone Design Pareto Optimization: Tradeoff Between Sensitivity and Noise Floor, Journal of Microelectromechanical Systems, vol.15, issue.6, pp.1632-1643, 2006.
DOI : 10.1109/JMEMS.2006.883884

Y. Li, C. Vancura, D. Barrettino, M. Graf, C. Hagleitner et al., Monolithic CMOS multi-transducer gas sensor microsystem for organic and inorganic analytes, Sensors and Actuators B: Chemical, vol.126, issue.2, pp.431-440, 2007.
DOI : 10.1016/j.snb.2007.03.035

M. Amabili and M. K. Kwak, FREE VIBRATIONS OF CIRCULAR PLATES COUPLED WITH LIQUIDS: REVISING THE LAMB PROBLEM, Journal of Fluids and Structures, vol.10, issue.7, pp.743-761, 1996.
DOI : 10.1006/jfls.1996.0051

J. E. Sader, Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope, Journal of Applied Physics, vol.84, issue.1, p.64, 1998.
DOI : 10.1063/1.368002

W. J. Josquin, Effectiveness of polycrystalline silicon diffusion sources, Applied Physics Letters, vol.43, issue.10, p.960, 1983.
DOI : 10.1063/1.94166

T. Inada, A. Kuranouchi, H. Hirano, T. Nakamura, Y. Kiyota et al., layers in silicon by thermal diffusion of boron and by subsequent rapid thermal annealing, Applied Physics Letters, vol.58, issue.16, p.1748, 1991.
DOI : 10.1063/1.105104

A. Y. Messaoud, E. Scheid, G. Sarrabayrouse, A. Claverie, and A. Martinez, A Comprehensive Study of Thin Rapid Thermal Oxide Films, Japanese Journal of Applied Physics, vol.32, issue.Part 1, No. 12A, pp.5805-5812, 1993.
DOI : 10.1143/JJAP.32.5805

R. Herdier, D. Jenkins, E. Dogheche, and D. , Laser Doppler vibrometry for evaluating the piezoelectric coefficient d33 on thin film, Review of Scientific Instruments, vol.77, issue.9, p.93905, 2006.
DOI : 10.1063/1.2349605

Y. Wang, C. Ganpule, B. T. Liu, H. Li, K. Mori et al., Epitaxial ferroelectric Pb(Zr,???Ti)O3 thin films on Si using SrTiO3 template layers, Applied Physics Letters, vol.80, issue.1, p.97, 2002.
DOI : 10.1063/1.1428413

S. Bühlmann, B. Dwir, J. Baborowski, and P. Muralt, Size effect in mesoscopic epitaxial ferroelectric structures: Increase of piezoelectric response with decreasing feature size, Applied Physics Letters, vol.80, issue.17, p.3195, 2002.
DOI : 10.1063/1.1475369

B. Jaffe, W. R. Cook, and H. Jaffe, Piezoelectric Ceramics, Journal of the American Ceramic Society, vol.36, issue.11, 1971.
DOI : 10.1143/JPSJ.7.333

S. Petitgrand, R. Yahiaoui, K. Danaie, A. Bosseboeuf, and J. P. Gilles, 3D measurement of micromechanical devices vibration mode shapes with a stroboscopic interferometric microscope, Optics and Lasers in Engineering, vol.36, issue.2, pp.77-101, 2001.
DOI : 10.1016/S0143-8166(01)00040-9

C. Ayela, Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007.

D. R. Southworth, L. M. Bellan, Y. Linzon, H. G. Craighead, and J. M. Parpia, Stress-based vapor sensing using resonant microbridges, Applied Physics Letters, vol.96, issue.16, p.163503, 2010.
DOI : 10.1063/1.3393999

H. Lamb, On the Vibrations of an Elastic Plate in Contact with Water, Proceedings of the royal society of London, pp.205-216, 1920.
DOI : 10.1098/rspa.1920.0064

C. Ayela and L. Nicu, Micromachined piezoelectric membranes with high nominal quality factors in newtonian liquid media: A Lamb's model validation at the microscale, Sensors and Actuators B: Chemical, vol.123, issue.2, pp.860-868, 2007.
DOI : 10.1016/j.snb.2006.10.048

M. Amabili and M. K. Kwak, FREE VIBRATIONS OF CIRCULAR PLATES COUPLED WITH LIQUIDS: REVISING THE LAMB PROBLEM, Journal of Fluids and Structures, vol.10, issue.7, pp.743-761, 1996.
DOI : 10.1006/jfls.1996.0051

T. P. Burg, M. Godin, S. M. Knudsen, W. Shen, G. Carlson et al., Weighing of biomolecules, single cells and single nanoparticles in fluid, Nature, vol.442, issue.7139, pp.1066-1069, 2007.
DOI : 10.1038/nature05741

F. Rossetti, M. Textor, and N. D. Spencer, ETH -SURFACE -Quartz Crystal Microbalance Technique (QCM) with Dissipation Monitoring Changes of both Adsorbed Mass and of Viscoelastic Properties of Adlayer

L. M. Bonanno and L. A. Delouise, Steric Crowding Effects on Target Detection in an Affinity Biosensor, Langmuir, vol.23, issue.10, pp.5817-5823, 2007.
DOI : 10.1021/la063659c

V. H. Perez-luna, M. J. O-'brien, K. A. Opperman, P. D. Hampton, G. P. López et al., Molecular Recognition between Genetically Engineered Streptavidin and Surface-Bound Biotin, Journal of the American Chemical Society, vol.121, issue.27, pp.6469-6478, 1999.
DOI : 10.1021/ja983984p

N. Huang, J. Vörös, S. M. De-paul, M. Textor, and N. D. Spencer, -poly(ethylene glycol):?? A Novel Polymeric Interface for Bioaffinity Sensing, Langmuir, vol.18, issue.1, pp.220-230, 2002.
DOI : 10.1021/la010913m

URL : https://hal.archives-ouvertes.fr/hal-00309089

T. Alava, N. Berthet-duroure, C. Ayela, E. Trévisiol, M. Pugnière et al., Parallel acoustic detection of biological warfare agents surrogates by means of piezoelectric immunochips, Sensors and Actuators B: Chemical, vol.138, issue.2, pp.532-538, 2009.
DOI : 10.1016/j.snb.2009.02.060

URL : https://hal.archives-ouvertes.fr/hal-00406164

. Abréviations-en-langue-française, ADN Acide Desoxyribo-Nucléique AGB Agent de Guerre Biologique APTES 3-aminopropyltriethoxysilane ARN Acide Ribo-Nucléique Bdf Bruit de fond biologique CABT Convention sur l'interdiction des Armes Biologiques et Toxicologiques CDNBC Centre de Défense Nucléaire Biologique et Chimique CEB Centre d'Etudes du Bouchet CpGV virus Cydia pomonella Granulosis DGA/MRIS Délégation Générale de l'Armement / Mission pour la Recherche et l'Innovation

. Nrbc-risque-nucléaire, B. Radiologique, U. Et-chimique, and . Unité-formant-colonie-abréviations-en-langue-anglaise, ADC Analog-to-Digital Converter Convertisseur Analogique-Numérique AFM Atomic Force Microscopy Microscopie à Force Atomique APDS Autonomous Pathogen Detection System Système Autonome de Détection de Pathogènes BAWS Biological Agent Warning Sensor Capteur d'Alerte d'Agents Biologiques BIDS Biological Integrated Detection System Système de Détection Biologique Intégré BOD Biochemical Oxygen Demand Demande Biochimique en Oxygène BSA Bovin Serum Albumin Albumine Sérique de Bovin CBDP Chemical and Biological Defense Program Programme de Défense Biologique et Chimique CCD Charge-Coupled Device Capteur photographique CDC Center for Disease Control Centre de Contrôle des Maladies (USA) DARPA Defense Advanced

A. Figure, 1 : Graphe du bilan des forces à l'encastrement de la membrane pour un rayon global donné (trait plein) comparé au seuil critique de flambement de la structure, p.5

C. Ayela, Micromembranes résonantes à actionnement et détection piézoélectriques intégrés pour la détection de molécules biologiques en temps réel, thèse, spécialité Conception des Circuits Microélectroniques et Microsystèmes, 2007.

R. Produits, Phosphate Buffer Saline (tampon phosphate salé), composition : NaCl 137 mM ; KCl 3 mM

J. Internationaux, Electronic scheme for multiplexed dynamic behavior excitation and detection of piezoelectric silicon-based micromembranes, IEEE of Sensors Journal, vol.8, issue.1, p.210, 2007.

T. Alava, . Mathieu, C. Mazenq, D. Soyer, L. Remiens et al., Silicon-based micromembranes with piezoelectric actuation and piezoresistive detection for sensing purposes in liquid media, Journal of Micromechanics and Microengineering, vol.20, issue.7, p.7, 2010.
DOI : 10.1088/0960-1317/20/7/075014

URL : https://hal.archives-ouvertes.fr/hal-00549532

F. Piezoelectric-actuated-alava, P. Mathieu, Y. Rameil, C. Morel, D. Soyer et al., Applied Physics Letters, accepted for publication Conférences internationales à comité de lecture: 1. Electrical equivalent circuit for air and liquid characterization of a multilayer micromembrane with piezoelectric actuation and read-out capabilities, NSTI Nanotechnology Conference and Trade Show, 2007.

T. Ayela, K. Alava, L. Haupt, and . Nicu, Investigation of molecularly imprinted polymers to detect proteins by an integrated, autonomous piezoelectric micromembrane platform, MicroTAS Conference, 2009.

T. Alava, F. Mathieu, D. Remiens, C. Soyer, and L. Nicu, MEMS-based multisensors platform with piezoelectric actuation and piezoresistive readout capabilities for biosensing applications, Biosensors, 2010.
URL : https://hal.archives-ouvertes.fr/hal-00574487

T. Alava, F. Mathieu, and L. Nicu, Resonating BioMEMS with integrated actuation and sensing for Biodefense applications, Conférences nationales : 1 Journées Nationales du GDR Micro et Nano structures, 2009.