58 3.2.1 Distinction de différentes zones dans l'image, p.59 ,
Studies of human locomotion ; past, present and future, Journal of Biomechanics, vol.33, pp.1217-1224, 2000. ,
Correcting for deformation in skin-based marker systems, Journal of Biomechanics, vol.34, issue.3, pp.355-361, 2001. ,
DOI : 10.1016/S0021-9290(00)00192-5
A point cluster method for in vivo motion analysis applied to a study of knee kinematics, Journal of Biomechanical Engineering, vol.20, pp.743-749, 1998. ,
Least-squares Fitting of Two 3D Point Sets, IEEE Transaction on Pattern Analysis and Machine Intelligence, vol.9, issue.5, pp.698-700, 1987. ,
A 3D Ultrasound-based tracking system for prostate biopsy distribution quality insurance and guidance, 2008. ,
3-D Ultrasound Probe Calibration for Computer-Guided Diagnosis and Therapy, CVAMIA, pp.248-259, 2006. ,
DOI : 10.1007/11889762_22
URL : https://hal.archives-ouvertes.fr/hal-00214270
Glenohumeral relationships buring physiologic shoulder motion and stress testing : initial experience with open mr imaging and active imaging-plane registration, Radiology, vol.212, pp.699-705, 1999. ,
Hierarchical chamfer matching: a parametric edge matching algorithm, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.10, issue.6, pp.849-865, 1988. ,
DOI : 10.1109/34.9107
A Survey of Image Registration Techniques, ACM Computing Surveys, vol.24, issue.4, pp.325-376, 1992. ,
Using 2.5D echography in computer assisted spine surgery, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ, pp.160-161, 1993. ,
DOI : 10.1109/IEMBS.1993.978480
Registration of 3d ct and ultrasound datasets of the spine using bone structures, Computer Aided Surgery, vol.7, pp.146-155, 2002. ,
Bone registration with 3D CT and ultrasound datasets, Lemke et al. [LVI + 03], pp.426-432 ,
DOI : 10.1016/s0531-5131(03)00396-0
URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.140.6564
Position and orientation in space of bones during movement: experimental artefacts, Clinical Biomechanics, vol.11, issue.2, pp.90-100, 1996. ,
DOI : 10.1016/0268-0033(95)00046-1
Multiple anatomical landmark calibration for optimal bone pose estimation, Human Movement Science, vol.16, issue.2-3, pp.259-276, 1997. ,
DOI : 10.1016/S0167-9457(96)00055-3
A solidification procedure to facilitate kinematic analyses based on video system data, Journal of Biomechanics, vol.28, issue.7, pp.879-884, 1995. ,
DOI : 10.1016/0021-9290(95)95278-D
Automated Multi-modality Image Registraction Based On Information Theory, Bizais and Barillot [BB95], pp.263-274 ,
Multi-Modality Image Registration based on Information Theory, 1998. ,
3D Multi-Modality Medical Image Registration Using Feature Space Clustering, CVRMed '95 : Proceedings of the First International Conference on Computer Vision, pp.195-204, 1995. ,
DOI : 10.1007/bfb0034948
Scapular kinematics during humeral elevation in adults and children, Clinical Biomechanics, vol.20, pp.600-606, 2005. ,
An Information Fusion Method for the Automatic Delineation of the Bone-Soft Tissues Interface in Ultrasound Images, ECCV Workshops CVAMIA and MMBIA, pp.218-229, 2004. ,
DOI : 10.1007/978-3-540-27816-0_19
Ultrasound bone segmentation using dynamic programming, IEEE International Ultrasonics Symposium, pp.2523-2526, 2007. ,
Automatic MR volume registration and its evaluation for the pelvis and prostate, Physics in Medicine and Biology, vol.47, issue.5, pp.823-838, 2002. ,
DOI : 10.1088/0031-9155/47/5/309
A comparison of lower-extremity skeletal kinematics measured using skin- and pin-mounted markers, Human Movement Science, vol.16, issue.2-3, pp.219-242, 1997. ,
DOI : 10.1016/S0167-9457(96)00053-X
The distribution of target registration error in rigid-body point-based registration, IEEE Transactions on Medical Imaging, vol.20, issue.9, pp.917-927, 2001. ,
DOI : 10.1109/42.952729
Soft-tissue artefact assessment during step-up using fluoroscopy ans skin-mounted marker, Journal of Biomechanics, vol.40, pp.518-524, 2007. ,
Une approche statistique multi-échelle au recalage rigide de surfaces : Application à l'implantologie dentaire, 2003. ,
The variability of shoulder motions recorded by means of palpation, Clinical Biomechanics, vol.12, pp.461-472, 1997. ,
Glenohumeral translation during active and passive elevation of the shoulder ??? a 3D open-MRI study, Journal of Biomechanics, vol.33, issue.5, pp.609-613, 2000. ,
DOI : 10.1016/S0021-9290(99)00209-2
2A-4 Enhancement of Bone Surface Visualization from 3D Ultrasound Based on Local Phase Information, 2006 IEEE Ultrasonics Symposium, pp.21-24, 2006. ,
DOI : 10.1109/ULTSYM.2006.20
Biomechanical model of the human shoulder joint???II. The shoulder rhythm, Journal of Biomechanics, vol.24, issue.8, pp.699-709, 1991. ,
DOI : 10.1016/0021-9290(91)90334-J
A Feasibility Study on Mutual Information based set-up Error Estimation for Radiotherapy, Medical Physics, issue.12, pp.282507-2517, 2001. ,
A accuracy estimation of kinematic data derived from bone anchored external markers, Proceedings of 3rd International Symposium on 3D Analysis of Human Movement, pp.27-30, 1994. ,
Rapid elastic image registration for 3-D ultrasound, IEEE Transactions on Medical Imaging, vol.21, issue.11, pp.1384-1394, 2002. ,
DOI : 10.1109/TMI.2002.806424
Measurement of the anteroposterior translation of the humeral head using MRI, International Orthopaedics, vol.21, issue.2, pp.77-82, 1997. ,
DOI : 10.1007/s002640050124
Dynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study, Journal of Biomechanical Engineering, vol.123, issue.2, pp.184-190, 2001. ,
DOI : 10.1115/1.1351892
Human movement analysis using stereophotogrammetry, Gait & Posture, vol.21, issue.2, pp.212-225, 2005. ,
DOI : 10.1016/j.gaitpost.2004.05.002
Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints, Journal of Biomechanics, vol.32, issue.2, pp.129-134, 1999. ,
DOI : 10.1016/S0021-9290(98)00158-4
Rigid Registration of 3D Ultrasound Data of Brain Tumours, Lemke et al. [LVI + 03], pp.433-439 ,
Semiautomatic registration of volumetric ultrasound scans, Ultrasound in Medicine & Biology, vol.25, issue.3, pp.339-347, 1999. ,
DOI : 10.1016/S0301-5629(98)00148-3
Calibration of the ???Flock of Birds??? electromagnetic tracking device and its application in shoulder motion studies, Journal of Biomechanics, vol.32, issue.6, pp.629-633, 1999. ,
DOI : 10.1016/S0021-9290(99)00011-1
Direct 3-dimensional measurement of scapular kinematics during dynamic movements in vivo, Journal of Shoulder and Elbow Surgery, vol.10, issue.3, pp.269-277, 2001. ,
DOI : 10.1067/mse.2001.112954
Dynamic Scapulohumeral Rhythm: The Effects of External Resistance During Elevation of the Arm in the Scapular Plane, Journal of Orthopaedic & Sports Physical Therapy, vol.27, issue.2, pp.125-133, 1998. ,
DOI : 10.2519/jospt.1998.27.2.125
Deviation of skin marker from bone target during movement of the scapula, Journal of Orthopaedic Science, vol.11, issue.2, pp.180-184, 2006. ,
DOI : 10.1007/s00776-005-1000-y
A survey of medical image registration, Medical Image Analysis, vol.2, issue.1, pp.1-36, 1998. ,
DOI : 10.1016/S1361-8415(01)80026-8
Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information, Medical Image Analysis, vol.3, issue.4, pp.373-386, 1999. ,
DOI : 10.1016/S1361-8415(99)80030-9
Determination of in vivo glenohumeral translation using fluoroscopy and shape-matching techniques, Journal of Shoulder and Elbow Surgery, vol.17, issue.2, pp.319-322, 2008. ,
DOI : 10.1016/j.jse.2007.05.018
Cadaver Validation of Intensity-Based Ultrasound to CT Registration, Lecture Notes in Computer Science, vol.3750, issue.2, pp.1000-1007, 2005. ,
DOI : 10.1007/11566489_123
Cadaver validation of intensity-based ultrasound to ct registration, Medical Image Analysis, vol.10, pp.385-395, 2006. ,
Registration of freehand 3D ultrasound and magnetic resonance liver images, Medical Image Analysis, vol.8, issue.1, pp.81-91, 2004. ,
DOI : 10.1016/j.media.2003.07.003
Accurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain, Journal Computer Assisted Tomography, vol.13, issue.1, pp.20-26, 1989. ,
(ii) the accuracy of surgical navigation for orthopaedic surgery, Current Orthopeadics, vol.21, pp.180-192, 2007. ,
Mutual information matching in multiresolution contexts, Image and Vision Computing, vol.19, issue.1-2, pp.45-52, 2001. ,
DOI : 10.1016/S0262-8856(00)00054-8
Three-dimensional extended field-of-view ultrasound, Ultrasound in Medicine & Biology, vol.32, issue.3, pp.357-369, 2006. ,
DOI : 10.1016/j.ultrasmedbio.2005.11.003
Numerical Recipes in C : The Art of Scientific Computing, 1992. ,
Automatic registration of 3-D ultrasound images, Ultrasound in Medicine & Biology, vol.24, issue.6, pp.841-854, 1998. ,
DOI : 10.1016/S0301-5629(97)00210-X
3D Freehand Ultrasound : Reconstruction and Spatial Compounding, 1998. ,
Rigid registration of 3-D ultrasound with MR images: a new approach combining intensity and gradient information, IEEE Transactions on Medical Imaging, vol.20, issue.10, pp.1038-1049, 2001. ,
DOI : 10.1109/42.959301
URL : https://hal.archives-ouvertes.fr/cea-00333699
Non-rigid registration using free-form deformations : Application to breast mr images, IEEE Trans. Med. Imaging, issue.8, pp.18712-721, 1999. ,
Evaluation of Linear Registration Algorithms for Brain SPECT and the Erros due to Hypoperfusion Lesions, Medical Physics, issue.8, pp.281660-1668, 2001. ,
Effect of skin movement on the analysis of skeletal knee joint motion during running, Journal of Biomechanics, vol.30, issue.7, pp.729-732, 1997. ,
DOI : 10.1016/S0021-9290(97)00001-8
Bone morphing : 3d morphological data for total knee arthroplasty, Computer Aided Surgery, vol.7, pp.156-168, 2002. ,
Improving in vivo knee kinematic measurements : application to prosthetic ligament analysis. The Knee, pp.179-190, 1996. ,
Multiresolution Voxel Similarity Measures for MR-PET Registration, Bizais and Barillot [BB95] ,
An overlap invariant entropy measure of 3D medical image alignment, Pattern Recognition, vol.32, issue.1, pp.71-86, 1998. ,
DOI : 10.1016/S0031-3203(98)00091-0
Evaluation of voxel-based registration of 3-D power Doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries, Ultrasound in Medicine & Biology, vol.27, issue.7, pp.945-955, 2001. ,
DOI : 10.1016/S0301-5629(01)00387-8
A general scheme for automatically building 3D morphometric anatomical atlases : application to a skull and a brain atlas, 16th L.A.S.R. Workshop Image Fusion And Shape Variability Techniques, pp.115-122, 1996. ,
URL : https://hal.archives-ouvertes.fr/inria-00615754
Comparing three attachment systems used to determine knee kinematics during gait, Gait & Posture, vol.25, issue.4, pp.533-543, 2007. ,
DOI : 10.1016/j.gaitpost.2006.06.002
A technique for noninvasive respiratory gated radiation treatment system based on a real time 3D ultrasound image correlation: A phantom study, Medical Physics, vol.4, issue.2, pp.31245-250, 2004. ,
DOI : 10.1118/1.1634482
Mutual information-based rigid and nonrigid registration of ultrasound volumes, IEEE Transactions on Medical Imaging, vol.21, issue.1, pp.9-22, 2002. ,
DOI : 10.1109/42.981230
Clinical Results of Percutaneous Pelvic Surgery. Computer Assisted Surgery Using Ultrasound Compared to Standard Fluoroscopy, Computer Aided Surgery, vol.71, issue.4, pp.204-211, 2001. ,
DOI : 10.1097/00005131-199711000-00007
Fast Non-Rigid Matching of 3D Medical Images, Proceedings of the Conference on Medical Robotics and Computer Assisted Surgery (MRCAS'95), 1995. ,
Optimization of Mutual Information for Multiresolution Image Registration Three-dimentional recording and description of motions of the shoulder mechanism, IEEE Transactions on Image Processing Journal of Biomachanical Engineering, vol.9, issue.117, pp.2083-209927, 1995. ,
Alignment by Maximization of Mutual Information, 1995. ,
Computer-aided hepatic tumour ablation : requirements and preliminary results, Compte-rendus de l'Académie des Sciences, pp.309-319, 2002. ,
Rapid Automated Algorithm for Aligning and Reslicing PET Images, Journal of Computer Assisted Tomography, vol.16, issue.4, pp.620-633, 1992. ,
DOI : 10.1097/00004728-199207000-00024
Some aspects of the biomechanics of the elbow joint related to prosthetic design, 1996. ,
Wells III. 2d-3d rigid registration of x-ray fluoroscopy and ct images using mutual information and sparsely ,