Arrêté du 3 mars 2003 fixant les listes des dispositifs médicaux soumis à l'obligation de maintenance et au contrôle de qualité mentionnés aux articles L. 5212-1 et D. 665-5-3 du code de la santé publique, Journal Officiel de la République Française, p.4848, 2003. ,
Image-guided radiation therapy: current and future directions, Future Oncology, vol.2, issue.4, pp.477-92, 2006. ,
DOI : 10.2217/14796694.2.4.477
Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system, International Journal of Radiation Oncology*Biology*Physics, vol.59, issue.4, pp.960-70, 2004. ,
DOI : 10.1016/j.ijrobp.2003.12.024
Quality Assurance of Image-Guidance Technologies, Seminars in Radiation Oncology, vol.17, issue.4, pp.278-86, 2007. ,
DOI : 10.1016/j.semradonc.2007.07.002
Advances in Image-Guided Radiation Therapy, Journal of Clinical Oncology, vol.25, issue.8, pp.25-938, 2007. ,
DOI : 10.1200/JCO.2006.09.9515
Image-guided radiotherapy: rationale, benefits, and limitations, The Lancet Oncology, vol.7, issue.10, pp.848-58, 2006. ,
DOI : 10.1016/S1470-2045(06)70904-4
In vivo dosimetry during external photon beam radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.43, issue.2, pp.245-59, 1999. ,
DOI : 10.1016/S0360-3016(98)00341-1
A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets, International Journal of Radiation Oncology*Biology*Physics, vol.45, issue.3, pp.45-773, 1999. ,
DOI : 10.1016/S0360-3016(99)00118-2
Cone-beam computed tomography with a flat-panel imager: Initial performance characterization, Medical Physics, vol.26, issue.6, pp.1311-1334, 2000. ,
DOI : 10.1118/1.599009
Flat-panel conebeam computed tomography for image-guided radiation therapy, Int J Radiat Oncol Biol Phys, issue.5, pp.53-1337, 2002. ,
Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40, Medical Physics, vol.21, issue.4, pp.581-618, 1994. ,
DOI : 10.1118/1.597316
The role of in vivo dosimetry in radiotherapy], Bull Cancer Radiother, vol.81, issue.4, pp.456-62, 1994. ,
The biological basis for conformal three-dimensional radiation therapy, International Journal of Radiation Oncology*Biology*Physics, vol.21, issue.3, pp.805-816, 1991. ,
DOI : 10.1016/0360-3016(91)90701-5
Décision du 27 juillet, p.14846, 2007. ,
Verification of the dose delivered to the patient by means of TLD, SC, PID, Cancer Radiother, vol.7, issue.1, pp.78-84, 2003. ,
Cone-beam-CT guided radiation therapy: A model for on-line application, Radiotherapy and Oncology, vol.75, issue.3, pp.75-271, 2005. ,
DOI : 10.1016/j.radonc.2005.03.026
Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research, Phys Med Biol, issue.6, pp.47-78, 2002. ,
Fluoroscopic visualization of megavoltage therapeutic x ray beams, International Journal of Radiation Oncology*Biology*Physics, vol.6, issue.7, pp.935-944, 1980. ,
DOI : 10.1016/0360-3016(80)90341-7
A review of electronic portal imaging devices (EPIDs), Medical Physics, vol.19, issue.1, pp.1-16, 1992. ,
DOI : 10.1118/1.596878
[A quality control test of the image obtained with electronic portal imaging devices, 2001. ,
Characterization of a fluoroscopic imaging system for kV and MV radiography, Medical Physics, vol.3032, issue.5, pp.898-905, 2000. ,
DOI : 10.1118/1.598955
Metal screen-film detector MTF at megavoltage x-ray energies, Medical Physics, vol.6, issue.6, pp.515-523, 1979. ,
DOI : 10.1118/1.594615
A practical method to measure the MTF of CT scanners, Medical Physics, vol.9, issue.5, pp.758-60, 1982. ,
DOI : 10.1118/1.595124
Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58, Medical Physics, vol.24, issue.6, pp.712-749, 2001. ,
DOI : 10.1118/1.1368128
Guide to clinical use of electronic portal imaging, Journal of Applied Clinical Medical Physics, vol.28, issue.2, pp.38-57, 2000. ,
DOI : 10.1120/jacmp.v1i2.2645
Use of digital fluoroscopy as an on-line verification device in radiation therapy, Phys Med Biol, issue.9, pp.31-985, 1986. ,
Commissioning and periodic quality assurance of a clinical electronic portal imaging device, International Journal of Radiation Oncology*Biology*Physics, vol.34, issue.1, pp.117-140, 1996. ,
DOI : 10.1016/0360-3016(95)02096-9
Advanced Image-Guided External Beam Radiotherapy, Cancer Treat Res, vol.139, pp.7-39, 2008. ,
DOI : 10.1007/978-0-387-36744-6_2
The value of frequent treatment verification films in reducing localization error in the irradiation of complex fields, Cancer, vol.31, issue.6, pp.37-2755, 1976. ,
DOI : 10.1002/1097-0142(197606)37:6<2755::AID-CNCR2820370628>3.0.CO;2-J
Optimization of image quality and dose for Varian aS500 electronic portal imaging devices (EPIDs), Physics in Medicine and Biology, vol.52, issue.23, 2007. ,
DOI : 10.1088/0031-9155/52/23/006
First clinical experience with a newly developed electronic portal imaging device, International Journal of Radiation Oncology*Biology*Physics, vol.18, issue.5, pp.1173-81, 1990. ,
DOI : 10.1016/0360-3016(90)90455-S
Quality assurance measurements of a-si epid performance, Medical Dosimetry, vol.29, issue.1, pp.11-18, 2004. ,
DOI : 10.1016/j.meddos.2003.09.002
Portal imaging technology: Past, present, and future, Seminars in Radiation Oncology, vol.5, issue.2, pp.115-133, 1995. ,
DOI : 10.1016/S1053-4296(95)80005-0
Therapy imaging: Source sizes of radiotherapy beams, Medical Physics, vol.15, issue.4, pp.517-541, 1988. ,
DOI : 10.1118/1.596295
A quality control test for electronic portal imaging devices, Medical Physics, vol.23, issue.7, pp.1237-1281, 1996. ,
DOI : 10.1118/1.597866
Video techniques for on-line portal imaging, Computerized Medical Imaging and Graphics, vol.13, issue.3, pp.217-243, 1989. ,
DOI : 10.1016/0895-6111(89)90128-6
Clinical application of??image-guided radiotherapy, IGRT (on??the??Varian OBI platform), Cancer/Radioth??rapie, vol.10, issue.5, pp.252-259, 2006. ,
DOI : 10.1016/j.canrad.2006.05.012
A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapy, Radiotherapy and Oncology, vol.11, issue.4, pp.369-78, 1988. ,
DOI : 10.1016/0167-8140(88)90208-3
Performance of a prototype fluoroscopic radiotherapy imaging system, International Journal of Radiation Oncology*Biology*Physics, vol.18, issue.1, pp.43-50, 1990. ,
DOI : 10.1016/0360-3016(90)90265-L
On-line radiotherapy imaging with an array of fiber-optic image reducers, International Journal of Radiation Oncology*Biology*Physics, vol.18, issue.6, pp.1477-84, 1990. ,
DOI : 10.1016/0360-3016(90)90324-D
Commissioning and Clinical Implementation of a Sliding Gantry CT Scanner Installed in an Existing Treatment Room and Early Clinical Experience for Precise Tumor Localization, American Journal of Clinical Oncology, vol.26, issue.3, pp.28-36, 2003. ,
DOI : 10.1097/01.COC.0000072509.66808.2C
Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy, Radiotherapy and Oncology, vol.48, issue.3, pp.335-343, 1998. ,
DOI : 10.1016/S0167-8140(98)00072-3
A practical method to measure the MTF of CT scanners, Medical Physics, vol.9, issue.5, pp.758-60, 1982. ,
DOI : 10.1118/1.595124
Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58, Medical Physics, vol.24, issue.6, pp.712-749, 2001. ,
DOI : 10.1118/1.1368128
Flat-panel cone-beam computed tomography for image-guided radiation therapy, International Journal of Radiation Oncology*Biology*Physics, vol.53, issue.5, pp.53-1337, 2002. ,
DOI : 10.1016/S0360-3016(02)02884-5
Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planning, Physics in Medicine and Biology, vol.47, issue.9, pp.1485-92, 2002. ,
DOI : 10.1088/0031-9155/47/9/304
In-room CT techniques for image-guided radiation therapy, Medical Dosimetry, vol.31, issue.1, pp.30-39, 2006. ,
DOI : 10.1016/j.meddos.2005.12.010
History of tomotherapy, Physics in Medicine and Biology, vol.51, issue.13, pp.427-53, 2006. ,
DOI : 10.1088/0031-9155/51/13/R24
Image guidance for precise conformal radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.56, issue.1, pp.89-105, 2003. ,
DOI : 10.1016/S0360-3016(03)00090-7
X-ray volumetric imaging in image-guided radiotherapy: The new standard in on-treatment imaging, International Journal of Radiation Oncology*Biology*Physics, vol.64, issue.2, pp.625-659, 2006. ,
DOI : 10.1016/j.ijrobp.2005.09.018
Evaluation of Geometric Accuracy and Image Quality of an On-Board Imager (OBI) Medical Radiation Physics, 2007. ,
Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy, The British Journal of Radiology, vol.79, issue.special_issue_1, 2006. ,
DOI : 10.1259/bjr/68255935
A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy, Medical Physics, vol.25, issue.7, pp.34-3005, 2007. ,
DOI : 10.1118/1.1420395
Linac-integrated kV-cone beam CT: Technical features and first applications, Medical Dosimetry, vol.31, issue.1, pp.31-62, 2006. ,
DOI : 10.1016/j.meddos.2005.12.008
Low-dose megavoltage cone-beam CT for radiation therapy, International Journal of Radiation Oncology*Biology*Physics, vol.61, issue.2, pp.61-552, 2005. ,
DOI : 10.1016/j.ijrobp.2004.10.011
Megavoltage cone-beam CT: Recent developments and clinical applications], Cancer Radiother, vol.3, issue.105, pp.258-68, 2006. ,
The calibration of CT Hounsfield units for radiotherapy treatment planning, Physics in Medicine and Biology, vol.41, issue.1, pp.111-135, 1996. ,
DOI : 10.1088/0031-9155/41/1/009
Developments in megavoltage cone beam CT with an amorphous silicon EPID: Reduction of exposure and synchronization with respiratory gating, Medical Physics, vol.26, issue.3, pp.819-848, 2005. ,
DOI : 10.1118/1.1861522
Implementations, comparisons, and an investigation of heuristic techniques for cone-beam tomography, IEEE Transactions on Medical Imaging, vol.15, issue.4, pp.519-550, 1996. ,
DOI : 10.1109/42.511755
Clinical application of??image-guided radiotherapy, IGRT (on??the??Varian OBI platform), Cancer/Radioth??rapie, vol.10, issue.5, pp.252-259, 2006. ,
DOI : 10.1016/j.canrad.2006.05.012
Image-guided radiotherapy using a mobile kilovoltage x-ray device, Medical Dosimetry, vol.31, issue.1, pp.31-40, 2006. ,
DOI : 10.1016/j.meddos.2005.12.003
Software tools dedicated for an automatic analysis of the CT scanner quality control images, Medical Imaging 2007: Physics of Medical Imaging, p.65104, 2007. ,
DOI : 10.1117/12.707343
URL : https://hal.archives-ouvertes.fr/hal-00326646
Clinical Implementation of Adaptive Helical Tomotherapy: A Unique Approach to Image-Guided Intensity Modulated Radiotherapy, Technology in Cancer Research & Treatment, vol.52, issue.1, pp.465-79, 2006. ,
DOI : 10.1016/S0360-3016(01)01512-7
Helical Tomotherapy: An Innovative Technology and Approach to Radiation Therapy, Technology in Cancer Research & Treatment, vol.49, issue.4, pp.311-317, 2002. ,
DOI : 10.1016/S0360-3016(98)00091-1
Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation, Physics in Medicine and Biology, vol.52, issue.3, pp.685-705, 2007. ,
DOI : 10.1088/0031-9155/52/3/011
Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning, International Journal of Radiation Oncology*Biology*Physics, vol.66, issue.5, pp.1553-61, 2006. ,
DOI : 10.1016/j.ijrobp.2006.08.031
A short-scan reconstruction for cone-beam CT using shift-invariant FBP and equal weighting, Medical Physics, vol.5535, issue.11, pp.34-4422, 2007. ,
DOI : 10.1117/12.560168
Mise en place de la radiothérapie en conditions stéréotaxiques au CRLC Val d'Aurelle -Paul Lamarque, 2006. ,
A diagnostic X ray field verification device for a 10 MV linear accelerator, International Journal of Radiation Oncology*Biology*Physics, vol.11, issue.3, pp.635-678, 1985. ,
DOI : 10.1016/0360-3016(85)90201-9
Quality Assurance of Image-Guidance Technologies, Seminars in Radiation Oncology, vol.17, issue.4, pp.278-86, 2007. ,
DOI : 10.1016/j.semradonc.2007.07.002
Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID), Medical Physics, vol.18, issue.2, pp.263-270, 1997. ,
DOI : 10.1118/1.598070
Quality Assurance Programme on Stereotactic Radiosurgery, Acta Neurochir, vol.62, pp.98-100, 1994. ,
DOI : 10.1007/978-3-7091-9371-6_20
Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58, Medical Physics, vol.24, issue.6, pp.712-749, 2001. ,
DOI : 10.1118/1.1368128
Dual-beam imaging for online verification of radiotherapy field placement, International Journal of Radiation Oncology*Biology*Physics, vol.33, issue.5, pp.1273-80, 1995. ,
DOI : 10.1016/0360-3016(95)00271-5
A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets, International Journal of Radiation Oncology*Biology*Physics, vol.45, issue.3, pp.45-773, 1999. ,
DOI : 10.1016/S0360-3016(99)00118-2
A method for determining the alignment accuracy of the treatment table axis at an isocentric irradiation facility, Physics in Medicine and Biology, vol.46, issue.1, pp.19-26, 2001. ,
DOI : 10.1088/0031-9155/46/1/404
New method of verification of the position of target points in stereotactic radiosurgery by linear accelerator], Nippon Hoshasen Gijutsu Gakkai Zasshi, issue.6, pp.58-802, 2002. ,
Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40, Medical Physics, vol.21, issue.4, pp.581-618, 1994. ,
DOI : 10.1118/1.597316
Commissioning experience with cone-beam computed tomography for image-guided radiation therapy, Journal of Applied Clinical Medical Physics, vol.66, issue.3 Suppl, p.2354, 2007. ,
DOI : 10.1120/jacmp.v8i3.2354
A system for stereotactic radiosurgery with a linear accelerator, International Journal of Radiation Oncology*Biology*Physics, vol.14, issue.2, pp.373-81, 1988. ,
DOI : 10.1016/0360-3016(88)90446-4
Linac mechanic QA using a cylindrical phantom, Physics in Medicine and Biology, vol.53, issue.18, pp.53-5139, 2008. ,
DOI : 10.1088/0031-9155/53/18/019
First clinical experience with a newly developed electronic portal imaging device, International Journal of Radiation Oncology*Biology*Physics, vol.18, issue.5, pp.1173-81, 1990. ,
DOI : 10.1016/0360-3016(90)90455-S
Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy, The British Journal of Radiology, vol.79, issue.special_issue_1, pp.66-78, 2006. ,
DOI : 10.1259/bjr/68255935
Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs, International Journal of Radiation Oncology*Biology*Physics, vol.47, issue.3, pp.47-825, 2000. ,
DOI : 10.1016/S0360-3016(00)00476-4
Quality assurance in linac-based stereotactic radiosurgery and radiotherapy, Medical Dosimetry, vol.23, issue.3, pp.147-51, 1998. ,
DOI : 10.1016/S0958-3947(98)00020-X
Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer, International Journal of Radiation Oncology*Biology*Physics, vol.65, issue.5, pp.65-1585, 2006. ,
DOI : 10.1016/j.ijrobp.2006.04.019
Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy, Medical Imaging 2008: Physics of Medical Imaging, p.69133, 2008. ,
DOI : 10.1117/12.768668
URL : https://hal.archives-ouvertes.fr/hal-00326648
On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers, Physics in Medicine and Biology, vol.45, issue.8, pp.45-2331, 2000. ,
DOI : 10.1088/0031-9155/45/8/318
Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS), Physics in Medicine and Biology, vol.41, issue.9, pp.1597-620, 1996. ,
DOI : 10.1088/0031-9155/41/9/003
Quality assurance in stereotactic radiosurgery using a standard linear accelerator, International Journal of Radiation Oncology*Biology*Physics, vol.21, issue.3, pp.737-785, 1991. ,
DOI : 10.1016/0360-3016(91)90694-Y
Introducing a system for automated control of rotation axes, collimator and laser adjustment for a medical linear accelerator, Physics in Medicine and Biology, vol.48, issue.9, pp.48-1123, 2003. ,
DOI : 10.1088/0031-9155/48/9/303
A quality assurance program for the on-board imagers, Med Phys, issue.11, pp.33-4431, 2006. ,
173 5.2.2.1. Modélisation de la source et de l'imageur portal, p.179 ,
Modélisation, . ,
LAP et GE) et des OTN indirects (3D) ,
objet-test LAP ont été générés, avec différents types de décalage (devant/derrière, bas/haut, gauche/droite) Ces OTN ont confirmé que nos algorithmes de contrôle de positionnement du laser ont une précision de un-demi pixel pour le décalage bas/haut et gauche/droite, et une précision égale à la moitié de l'épaisseur de coupe en ce qui concerne le décalage devant/derrière ,
objet-test GE ont été générés pour contrôler la précision et les limites de nos algorithmes Ils nous ont notamment permis d'évaluer et de comparer différentes méthodes de détermination de la FTM. FTM pratique selon Droege et Morin (Droege and Morin 1982) et la transformée de Fourier de la réponse impulsionnelle du système (PSF) Dans ce cas, 2007. ,
en géométrie divergente ont été générés pour simuler les images du contrôle mécanique de l'imageur embarqué sur un appareil de traitement par radiothérapie, 2008. ,
de 4 millimètres sur l'axe bas-haut et de 3 millimètres sur l'axe droite-gauche. L'OTN est composé de 9 images portales qui correspondent à 9 différents angles du statif, 280° et 320°), dsa = 100 cm ,
Simulations réalistes de données de tomographie d'émission monophotonique TEMP pour l'évaluation des méthodes de recalage TEMP/IRM utilisant des mesures statistiques de similarité : application dans le contexte de la fusion de données en élpilépsie, 2002. ,
Design and construction of a realistic digital brain phantom, IEEE Transactions on Medical Imaging, vol.17, issue.3, pp.463-471, 1998. ,
DOI : 10.1109/42.712135
Objets-tests Numériques pour le contrôle de qualité des systèmes de planification géométrique des traitements en radiothérapie, Thèse de Doctorat, 2008. ,
Digital reconstructed radiography quality control with software methods, Medical Imaging 2005: Physics of Medical Imaging, pp.1002-1013, 2005. ,
DOI : 10.1117/12.593415
Discrete and continuous description of a three-dimensional scene for quality control of radiotherapy treatment planning systems, Medical Imaging 2006: Physics of Medical Imaging, pp.614255-614256, 2006. ,
DOI : 10.1117/12.650571
URL : https://hal.archives-ouvertes.fr/hal-00360298
A practical method to measure the MTF of CT scanners, Medical Physics, vol.9, issue.5, pp.758-60, 1982. ,
DOI : 10.1118/1.595124
A system for stereotactic radiosurgery with a linear accelerator, International Journal of Radiation Oncology*Biology*Physics, vol.14, issue.2, pp.373-81, 1988. ,
DOI : 10.1016/0360-3016(88)90446-4
Application of a surface matching image registration technique to the correlation of cardiac studies in positron emission tomography (PET) by transmission images, Physics in Medicine and Biology, vol.40, issue.10, pp.40-1695, 1995. ,
DOI : 10.1088/0031-9155/40/10/010
Utilization of 3-D elastic transformation in the registration of chest X-ray CT and whole body PET, IEEE Trans Nucl. Med, issue.44, pp.1606-1612, 1997. ,
Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy, Medical Imaging 2008: Physics of Medical Imaging, p.69133, 2008. ,
DOI : 10.1117/12.768668
URL : https://hal.archives-ouvertes.fr/hal-00326648
Software tools dedicated for an automatic analysis of the CT scanner quality control images, Medical Imaging 2007: Physics of Medical Imaging, p.65104, 2007. ,
DOI : 10.1117/12.707343
URL : https://hal.archives-ouvertes.fr/hal-00326646
Evaluation of two Software Tools dedicated to an Automatic Analysis of the CT Scanner Image Spatial Resolution, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp.3910-3913, 2007. ,
DOI : 10.1109/IEMBS.2007.4353188