H. O. Anger3-]-r and . Jaszczak, Scintillation camera with multichannel collimators Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT, J. Nucl. Med. Phys. Med. Biol, vol.54, issue.39, pp.515-531, 1964.

J. B. Habraken, Evaluation of High-Resolution Pinhole SPECT Using a Small Rotating Animal, High-Resolution SPECT Using Multipinhole Collimation, pp.1863-1869, 2001.

Z. Liu, Quantitative Analysis of Acute Myocardial Infarct in Rat Hearts with Ischemia ? Reperfusion Using a High-Resolution Stationary SPECT System FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager, Performance Evaluation of a Multipinhole Small Animal SPECT System Smith et al., Design of Multipinhole Collimators for Small Animal SPECT, Conf. Record of the 2003 IEEE Nuclear Scaince Symposium and Medical Imaging Conference, pp.933-939, 2002.

Z. Cao, Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging ? a simulation study Design and simulation of a high-resolution stationary SPECT system for small animals Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation, Phys. Med. Biol. Phys. Med. Biol. Phys. Med. Biol, vol.5015, issue.48, pp.4609-4624, 2003.

M. F. Smith, An analytic model of pinhole aperture penetration for 3D pinhole SPECT image reconstruction Analytic Determination of the Pinhole Collimator sensitivity with penetration Analytic Determination of the Pinhole Collimator's Point-Spread Function and RMS Resolution With Penetration, Phys. Med. Biol. IEEE Trans. Med. Ima. IEEE Trans. Med. Ima, vol.4317, issue.21 8, pp.761-775, 1998.

R. Accorsi, Analytic Determination of the Resolution-Equivalent Effective Diameter of a Pinhole Collimator, IEEE Transactions on Medical Imaging, vol.23, issue.6, 2004.
DOI : 10.1109/TMI.2004.826951

R. Accorsi, Resolution-Effective Diameters for Asymmetric-Knif-Edge Pinhole Collimators, IEEE Trans. Med. Ima, vol.2420, issue.12, 2005.
DOI : 10.1109/tmi.2005.857229

M. Gieles, Fast Simulation of micro-pinhole imaging by mixing Monte Carlo and Analytical modelling, Image Science Institute, vol.21, 2002.

M. Gieles, Monte Carlo simulations of pinhole imaging accelerated by kernelbased forced detection An Integrated PET-SPECT Small Animal Imager: preliminary results Performance Characteristics of an Integrated Small Animal SPECT/CT Unit, Simultaneous PET/SPECT imaging with the YAP-(S)PET Scanner, AMI Annual Conference, pp.1853-1867, 2000.

G. D. Domenico, PET small animal scanner: quantitative results [26] E. Baussan, Le trajectographe électronique associé à la cible de l'expérience d'oscillation de neutrinos OPERA Electronics dedicated to multi-anode photomultiplier tubes for imaging scintigraphic devices, 14th IEEE ? NPSS Real Time conference Opera/spl I.bar/ROC: A front-end chip for Opera multi-anode photomultipliers, IEEE Trans. Nucl. Sci IEEE Nuclear Science Symposium Conference Record, vol.5029, issue.1, pp.1351-1356, 2003.

A. Lucotte, A front-end read out chip for the OPERA scintillator tracker, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.521, issue.2-3, pp.378-392, 2004.
DOI : 10.1016/j.nima.2003.10.104

URL : https://hal.archives-ouvertes.fr/in2p3-00021919

T. W. Geneva, Contrinution to locating interactions and identifying trajectories in the OPERA detector, thesis [31] F. James, MINUIT Function Minimization and Error Analysis, CERN Program Library Long Writeup D506, Computing and Networks Division An ISPA-Camera for Gamma Rays with Improved Energy Resolution, IEEE Trans. Nucl. Sci, vol.4433, issue.5, 1997.

F. Vittori, T. Malatesta, F. De-notaristefani, A. Del-guerra, C. Damiani et al., An Integrated PET-SPECT Small Animal Imager: preliminary results Performance Evaluation of the Fully Engineered YAP-(S)PET Scanner for Small Animal Imaging Analytic and Iterative Reconstruction Algorithms in SPECT Towards an inline reconstruction architecture for micro-CT system On the determination of function from their integals along certain manifolds, traduction de l'article de J. Radon en 1917 par R. Lobner, School of mathematic, Georgia Institutes of technology, Ce and CsI:Tl multipillar matrices. [41] S. Agostinelli et al. Geant4 Developments and Applications, pp.497-506, 1984.

R. Gordon, G. Herman, M. E. Daube-witherspoon, and G. Muehllehner, Three-dimensional reconstruction from projections: a review of algorithms Treatment of axial data in threedimensional PET Simultaneous algebraic reconstruction technique (SART): a superior implementation of the ART algorithm, Preconditioning Methods For Shift Variant Image Reconstruction, International Conference on Image Processing, pp.111-151, 1974.

H. Hartley, Maximum likelihood estimation from incomplete data Maximum likelihood from incomplete data using the EM algorithm, Biometrics Journal of the Royal Statistical Society, vol.1450, pp.174-194, 1958.

J. Qi, R. Hudson, R. S. Larkin, S. E. Derenzo, T. F. Budinger et al., Accelerated image reconstruction using ordered subsets of projection data Imaging properties of a positron tomograph with 280 BGO crystals Accelerated Image Reconstruction using Ordered Subsets of Projection Data An accurate iterative reconstruction algorithm for spare objets: application to 3D blood vessel reconstruction from limited number of projections, Iterative reconstruction techniques in emission computed tomography, pp.541-578, 1981.

R. Accorsi and S. D. Metzler, Resolution-effective diameters for asymmetric-knife-edge pinhole collimators, Matsumoto and M. Senda, Development of a GSO positron/singlephoton imaging detector, pp.457-469, 2005.
DOI : 10.1109/TMI.2005.857229