Regularly occurring periods of eye motility and concomitant phenomena during sleep, Science, vol.118, pp.273-274, 1953. ,
Sleep structure: a new diagnostic tool for stage determination in sleeping sickness, Acta Tropica, vol.93, issue.1, pp.107-124, 2005. ,
DOI : 10.1016/j.actatropica.2004.10.001
Guidance of a wheelchair using electrooculography, Proceeding of the 3rd IMACS International Multiconference on Circuits, Systems, Communications and Computers (CSCC'99), 1999. ,
Comparison between five classifiers for automatic scoring of human sleep recordings, Proceedings of the 1 st international conference on fuzzy systems and knowledge discovery, 2005. ,
Modafinil, d-amphetamine and placebo during 64 hours of sustained mental work. II. Effects on two nights of recovery sleep, Journal of Sleep Research, vol.12, issue.4, pp.229-241, 1995. ,
DOI : 10.1111/j.1365-2869.1995.tb00173.x
Dipole modeling of eye activity and its application to the removal of eye artefacts from the EEG and MEG, Clin Phys Physiol Meas, vol.12, pp.49-54, 1991. ,
Dipole models of eye movements and blinks, Electroencephalogr Clin Neurophysiol, vol.79, issue.1, pp.36-44, 1991. ,
A multiple source approach to the correction of eye artifacts, Electroencephalogr Clin Neurophysiol, vol.90, issue.3, pp.229-241, 1994. ,
Muscle artifacts in the sleep EEG: Automated detection and effect on all-night EEG power spectra, Journal of Sleep Research, vol.5, pp.155-164, 1996. ,
A glossary of terms commonly used cliubnical electroencephalographers, Electroencephalogr Clin Neurophysiol, vol.37, pp.538-548, 1974. ,
The origin of biopotentials Medical Instrumentation, Application and Design, pp.121-182, 1998. ,
Distinctive effect of modafinil and d-amphetamine on the homeostatic and circadian modulation of the human waking EEG, Psychopharmacology, 2003. ,
Classification en tempsfréquence à partir de données expertisées -Application à la détection des complexes-K, 2002. ,
Important factors in surface EMG measurement Available at: <http://www.bortec.ca, Bortec Medical Ltd, 2002. ,
ACTION POTENTIALS OF THE BRAIN, Archives of Neurology & Psychiatry, vol.36, issue.6, pp.1214-1224, 1936. ,
DOI : 10.1001/archneurpsyc.1936.02260120061004
Cyclic Variations in EEG During Sleep and their Relation to Eye Movements, Body Motility and Dreaming, Electroencephalogr. Clin. Neurophysiol, vol.9, pp.673-390, 1957. ,
A simple system for detection of EEG artifacts in polysomnographic recordings, IEEE Trans. Biomed. Eng, vol.50, issue.4, pp.526-528, 2003. ,
Interrater reliability between scorers from eight European sleep laboratories in subjects with different sleep disorders, J Sleep Res, vol.13, pp.63-69, 2004. ,
K-complexes and sleep spindles before transient activation during sleep, Sleep, vol.4, pp.400-407, 1981. ,
Fundamentals of Neural Networks, 1994. ,
A reliable probabilistic sleep stager based on a single EEG signal, Artificial Intelligence in Medicine, issue.3, pp.33199-207, 2005. ,
Transformations towards the normal distribution of broad band spectral parameters of the EEG, Electroencephalogr Clin Neurophysiol, pp.119-124, 1982. ,
The objective study of mental imagery. I. Physiological concomitance. Appendix on new method of electroencephalographic analysis, Journal of Mental Science, vol.89, pp.216-223, 1943. ,
Automatic recognition of rapid eye movement (REM) sleep by artificial neural networks, J Sleep Res, vol.4, pp.86-91, 1995. ,
The correction of EOG artifacts by frequency dependent and frequency independent methods, Psychophysiology, vol.23, issue.6, pp.704-712, 1986. ,
K-complex Detection using the Continuous Wavelet Transform: EEG analysis based on time domain properties, Electroencephalography and Clinical Neurophysiology, vol.29, pp.306-310, 1970. ,
The physical significance of time domain descriptors in EEG analysis, Electroencephalography and Clinical Neurophysiology, vol.34, issue.3, pp.321-325, 1973. ,
DOI : 10.1016/0013-4694(73)90260-5
Proposed supplements and amendments to 'A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects', the Rechtschaffen & Kales (1968) standard, pp.305-310, 2001. ,
Autonomic correlates of the spontaneous K-complex, Psychophysiology, vol.4, pp.444-452, 1968. ,
Agreement in visual scoring of sleep stages among laboratories in Japan, Journal of Sleep Research, vol.1, pp.58-60, 1992. ,
Removal of the ocular artifact from the EEG: a comparison of time and frequency domain methods with simulated and real data, Psychophysiology, vol.28, issue.1, pp.114-121, 1991. ,
Úvod do biomechaniky svalové ?innosti p?i t?lesném pohybu ?lov?ka, Praha : SPN, 1972. ,
A Sleep Spindle Detection Algorithm, 2002. ,
Cerebral states during sleep, as studied by human brain potentials, J Exp Psychol, vol.21, pp.127-144, 1937. ,
Distribution of disturbance patterns in the human electroencephalogram, with special reference to sleep, J Neurophysiol, vol.1, pp.413-430, 1938. ,
Independent component analysis of electroencephalographic data Advances in neural information processing systems 8, pp.145-151, 1996. ,
Evaluation of Hjorth parameters in forearm surface EMG analysis during an occupational repetitive task, Electroencephalography and Clinical Neurophysiology, vol.101, issue.2, pp.181-184, 1996. ,
On Estimation of Entropy and Mutual Information of Continuous Distributions, Signal Processing, vol.16, issue.3, pp.233-246, 1989. ,
Biopotential electrodes Medical Instrumentation, Application and Design, pp.183-232, 1998. ,
Sleep and EEG. Electroencephalography: Basic principles, clinical applications and related fields, pp.174-185, 1998. ,
Interobserver agreement among sleep scorers from different centers in a large dataset, Sleep, vol.23, issue.7, pp.901-908, 2000. ,
Evaluation of missing value estimation for microarray data, J. Data Sci, vol.2, pp.347-370, 2004. ,
Digital analysis and technical specifications, J Clin Sleep Med, vol.3, issue.2, pp.109-129, 2007. ,
Léka?ské diagnostické p?ístroje : U?ební texty, 2004. ,
The K-complex variability in normal subjects Phasics events and dynamic organisation of sleep, pp.167-184, 1991. ,
The use of polysomnography in the evaluation of insomnia, Sleep, vol.18, pp.58-70, 1995. ,
Review of neural network applications in sleep research, Journal of Neuroscience Methods, vol.79, pp.187-193, 1998. ,
Techniques of EMG signal analysis: detection, processing, classification and applications, Biological Procedures Online, vol.8, issue.1, pp.11-35, 2006. ,
A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects, 1968. ,
Adult rat vigilance state discrimination by artificial neural network using a single EEG channel, Physiol and Behav, vol.59, issue.6, pp.1051-1060, 1996. ,
Joint time and time-frequency optimal detection of K-complexes in sleep EEG. Computers and biomedical research, pp.31-209, 1998. ,
Spectral edge frequency-a new correlate of anesthetic depth, Anesthesiology, vol.53, pp.512-517, 1980. ,
A solution for reliable and valid reduction of ocular artifacts, applied to the P300 ERP, Psychophysiology, issue.6, pp.23695-703, 1986. ,
Two bilateral sources of the late EP as identified by a spatio-temporal dipole model, Electroenceph. Clin. Neurophysiol, vol.62, pp.32-44, 1985. ,
Quality Control of polysomnographic Sleep Data by Histogram and Entropy Analysis, Clin. Neurophysiol, issue.12, pp.110-2165, 1999. ,
Neural network model: application to automatic analysis of human sleep, Computers and Biomedical Research, vol.26, pp.157-171, 1993. ,
Sleep Stage scoring using neural network model: comparison between visual and automatic analysis in normal subjects and patients, Sleep, vol.19, pp.26-35, 1996. ,
Dealing with missing values in neural network-based diagnostic systems, Neural Computing and Applications, pp.73-77, 1995. ,
DOI : 10.1007/BF01421959
Missing value estimation methods for DNA microarrays, Bioinformatics, issue.6, pp.17-520, 2001. ,
Automatic detection of rapid eye movements by discrete wavelet transform, Psychiatry Clin Neurosci, vol.54, pp.276-277, 2000. ,
Detection of muscle artefact in the normal human awake EEG, Electroencephalography and Clinical Neurophysiology, vol.107, issue.2, pp.149-58, 1998. ,
DOI : 10.1016/S0013-4694(98)00052-2
Extraction of ocular artefacts from EEG using independent component analysis, Electroencephalography and Clinical Neurophysiology, vol.103, issue.3, pp.395-404, 1997. ,
DOI : 10.1016/S0013-4694(97)00042-8
Detektion von Rapid-Eye-Movements mit schnell adaptierenden neuronalen Fuzzy-Systemen bei unsicherer REM-Syntax - Detection of Rapid-Eye-Movement with Rapidly Adapting Fuzzy-Systems Despite Imprecise Syntax, Biomedizinische Technik/Biomedical Engineering, vol.41, issue.4, pp.84-90, 1996. ,
DOI : 10.1515/bmte.1996.41.4.84
A Wavelet Based De-Noising Technique For Ocular Artifact Correction Of The Electroencephalogram Feature selection for sleep/wake stages classification using data driven methods, International Conference of the IEEE Engineering in Medicine and Biology Society Biomedical Signal Processing and Control, vol.2, issue.3, pp.171-179, 2002. ,
Missing-value estimation using linear and non-linear regression with Bayesian gene selection, Bioinformatics, vol.19, issue.17, pp.2302-2307, 2003. ,