Kinetic screening of antibodies from crude hybridoma samples using Biacore, Analytical Biochemistry, vol.325, issue.2, p.301, 2004. ,
DOI : 10.1016/j.ab.2003.11.004
Biosensors for detection of pathogenic bacteria, Biosensors and Bioelectronics, vol.14, issue.7, p.599, 1999. ,
DOI : 10.1016/S0956-5663(99)00039-1
The antibody binding site. Labelling of a specific antibody against the photo-precursor of an aryl nitrene, Biochemical Journal, vol.128, issue.3, p.499, 1972. ,
DOI : 10.1042/bj1280499
Synthesis and evaluation of oligodeoxyribonucleotides containing an aryl(trifluoromethyl)diazirine moiety as the cross-linking probe: photoaffinity labeling of mammalian DNA polymerase ??, Nucleic Acids Research, vol.25, issue.12, pp.2352-485, 1997. ,
DOI : 10.1093/nar/25.12.2352
2-Benzoylbenzoic Acid:?? A Photolabile Mask for Alcohols and Thiols, The Journal of Organic Chemistry, vol.61, issue.26, p.9455, 1996. ,
DOI : 10.1021/jo961638p
Micron-Scale Patterning of Biological Molecules, Barie et al, p.91, 1995. ,
DOI : 10.1002/anie.199500911
Photoactivatable Cross-Linked Polyacrylamide for the Site-Selective Immobilization of Antigens and Antibodies, Chemistry of Materials, vol.10, issue.6, p.1510, 1998. ,
DOI : 10.1021/cm970632t
The Electrical Discharge from Liquid Points, and a Hydrostatic Method of Measuring the Electric Intensity at Their Surfaces, Physical Review, vol.3, issue.2, p.69, 1914. ,
DOI : 10.1103/PhysRev.3.69
Two-Component Graded Deposition of Biomolecules with a Double-Barreled Nanopipette, Angewandte Chemie International Edition, vol.77, issue.42, p.6854, 2005. ,
DOI : 10.1002/anie.200502338
Microfabricated Quill-Type Surface Patterning Tools for the Creation of Biological Micro/Nano Arrays, Biomedical Microdevices, vol.6, issue.2, p.117, 2004. ,
DOI : 10.1023/B:BMMD.0000031748.13353.10
Micromachined Transducers Sourcebook, 1998. ,
Hydrogels in Medicine and Pharmacy, Biomed. Microdev. Z. Phys, vol.2, issue.216, pp.131-398, 1968. ,
192 Stress-sensing and mass-sensing methods at the microscale were reviewed in detail by C. Bergaud, Habilitation à diriger les recherches thesis, Nat. Biotechnol. Biosens. Bioelectron. Sens. Act. Chem. Adv. Drug Deliv. Rev. PNAS USA Biophys. J, vol.21, issue.90, pp.1192-1560, 1994. ,
Cantilever Sensor for Nanomechanical Detection of Specific Protein Conformations, Nano Letters, vol.5, issue.12, pp.2385-2690, 2005. ,
DOI : 10.1021/nl051449z
13 th Int. Conf. Solid-State Sens, Transducers '05) Proc. 593, p.3010, 2003. ,
Viscosity measurements based on experimental investigations of composite cantilever beam eigenfrequencies in viscous media, Review of Scientific Instruments, vol.71, issue.6, p.2487, 2000. ,
DOI : 10.1063/1.1150640
13 th Int. Conf. Solid-State Sens, Transducers '05) Proc. 247 (2005) 202 T. Burg et al, p.1066, 2007. ,
Detect of Escherichia coli O157:H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors, Biosensors and Bioelectronics, vol.22, issue.7, p.1296, 2007. ,
DOI : 10.1016/j.bios.2006.05.028
Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1mL/min, Biosensors and Bioelectronics, vol.22, issue.1, p.78, 2006. ,
DOI : 10.1016/j.bios.2005.12.002
Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water, Biosensors and Bioelectronics, vol.22, issue.12, p.3028, 2007. ,
DOI : 10.1016/j.bios.2007.01.012
211 cfu = colony forming units 212, Sens. Act. Phys. A43, pp.2762-164, 1989. ,
Micro???fabricated piezoelectric cantilever for atomic force microscopy, Review of Scientific Instruments, vol.67, issue.11, p.3898, 1996. ,
DOI : 10.1063/1.1147290
Viscosity measurements based on experimental investigations of composite cantilever beam eigenfrequencies in viscous media, Review of Scientific Instruments, vol.71, issue.6, pp.2487-60, 1999. ,
DOI : 10.1063/1.1150640
Fabrication of Microcantilever Sensors Actuated by Piezoelectric Pb(Zr0.52Ti0.48)O3 Thick Films and Determination of Their Electromechanical Characteristics, Advanced Functional Materials, vol.68, issue.12, p.2021, 2005. ,
DOI : 10.1002/adfm.200500331
Piezoelectric diaphragm as a high performance biosensor platform, Applied Physics Letters, vol.89, issue.22, p.223508, 2006. ,
DOI : 10.1063/1.2396919
Textbook of Medical Physiology 286 For the major part of results (some being still unpublished) presented from now and to the end of the second chapter I am indebted to my student, 2000. ,
Determination of the d31 piezoelectric coefficient of PbZrxTi1???xO3 thin films using multilayer buckled micromembranes, Journal of Applied Physics, vol.100, issue.5, p.54908, 2006. ,
DOI : 10.1063/1.2338139
URL : https://hal.archives-ouvertes.fr/hal-00130888
Thin Solid Films 327-329, 1997. ,