B. Annexe, Articles Six axis inertial sensor using cold-atom interferometry B. Canuel, F

. Gauguet, soumis pour publication dans la Revue Française de métrologie. [1] O. Carnal and J. Mlynek, Phys. Rev. Lett, vol.66, p.2689, 1991.

D. W. Keith, C. R. Ekstrom, Q. A. Turchette, and D. E. Pritchard, An interferometer for atoms, Physical Review Letters, vol.66, issue.21, p.2693, 1991.
DOI : 10.1103/PhysRevLett.66.2693

M. Kasevich and S. Chu, Atomic interferometry using stimulated Raman transitions, Physical Review Letters, vol.67, issue.2, p.181, 1991.
DOI : 10.1103/PhysRevLett.67.181

J. M. Mcguirk, G. T. Foster, J. B. Fixler, M. J. Snadden, and M. A. Kasevich, Sensitive absolute-gravity gradiometry using atom interferometry, Physical Review A, vol.65, issue.3, p.33608, 2002.
DOI : 10.1103/PhysRevA.65.033608

T. L. Gustavson, P. Bouyer, and M. A. Kasevich, Precision Rotation Measurements with an Atom Interferometer Gyroscope, Physical Review Letters, vol.78, issue.11, p.2046, 1997.
DOI : 10.1103/PhysRevLett.78.2046

A. Lenef, T. D. Hammond, E. T. Smith, M. S. Chapman, R. A. Rubenstein et al., Rotation Sensing with an Atom Interferometer, Physical Review Letters, vol.78, issue.5, p.760, 1997.
DOI : 10.1103/PhysRevLett.78.760

A. Clairon, . Ph, G. Laurent, S. Santarelli, S. N. Ghezali et al., A cesium fountain frequency standard: preliminary results, IEEE Transactions on Instrumentation and Measurement, vol.44, issue.2, p.128, 1995.
DOI : 10.1109/19.377790

M. Kasevich, D. S. Weiss, E. Riis, K. Moler, S. Kasapi et al., Atomic velocity selection using stimulated Raman transitions, Physical Review Letters, vol.66, issue.18, p.2297, 1991.
DOI : 10.1103/PhysRevLett.66.2297

T. L. Gustavson, A. Landragin, and M. A. Kasevich, Rotation sensing with a dual atom-interferometer Sagnac gyroscope, Classical and Quantum Gravity, vol.17, issue.12, p.2385, 2000.
DOI : 10.1088/0264-9381/17/12/311

J. Fils, F. Leduc, P. Bouyer, D. Holleville, N. Dimarcq et al., Influence of optical aberrations in an atomic gyroscope, The European Physical Journal D, vol.54, issue.3, p.257, 2005.
DOI : 10.1140/epjd/e2005-00255-9

URL : https://hal.archives-ouvertes.fr/hal-00005869

A. Clairon, . Ph, G. Laurent, S. Santarelli, S. N. Ghezali et al., A cesium fountain frequency standard: preliminary results, IEEE Transactions on Instrumentation and Measurement, vol.44, issue.2, p.128, 1995.
DOI : 10.1109/19.377790

F. Riehle, . Th, A. Kister, J. Witte, C. J. Helmcke et al., Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer, Physical Review Letters, vol.67, issue.2
DOI : 10.1103/PhysRevLett.67.177

T. L. Gustavson, A. Landragin, and M. Kasevich, Rotation sensing with a dual atominterferometer Sagnac gyroscope, Class. Quantum. Grav, vol.17, issue.1, 2000.

A. Peters, K. Y. Chung, and S. Chu, High-precision gravity measurements using atom interferometry, Metrologia, vol.38, issue.1, p.25, 2001.
DOI : 10.1088/0026-1394/38/1/4

T. M. Niebauer, G. S. Sasagawa, J. E. Faller, R. Hilt, and F. Klopping, A new generation of absolute gravimeters, Metrologia, vol.32, issue.3, p.159, 1995.
DOI : 10.1088/0026-1394/32/3/004

G. E. Stedman, Ring-laser tests of fundamental physics and geophysics, Reports on Progress in Physics, vol.60, issue.6, pp.615-688, 1997.
DOI : 10.1088/0034-4885/60/6/001

F. Leduc, D. Holleville, J. Fils, A. Clairon, N. Dimarcq et al., COLD ATOM GYROSCOPE FOR PRECISION MEASUREMENTS, Laser Spectroscopy, pp.68-70, 2003.
DOI : 10.1142/9789812703002_0011

P. Cheinet, F. Pereira-dos-santos, A. Clairon, N. Dimarcq, D. Holleville et al., Gravim??tre ?? atomes froids, Journal de Physique IV (Proceedings), vol.119, issue.119, p.153, 2004.
DOI : 10.1051/jp4:2004119033

L. Alves, S. Chassagne, and . Topçu, The BNM Watt Balance Project, IEEE Trans. Inst. Meas

M. Kasevich and S. Chu, Atomic interferometry using stimulated Raman transitions, Physical Review Letters, vol.67, issue.2, p.181, 1991.
DOI : 10.1103/PhysRevLett.67.181

. J. Ch and . Bordé, Atom interferometry and laser spectroscopy, p.239, 1991.

. Ch, C. J. Antoine, and . Bordé, Quantum theory of atomic clocks and gravito-inertial sensors: an update, J. Opt. B: Quantum Semiclass. Opt, vol.5, pp.199-207, 2003.

G. J. Dick, Local Ocillator induced instabilities, Proc. Nineteenth Annual Precise Time and Time Interval, pp.133-147, 1987.

M. Kasevich and S. Chu, Measurement of the gravitational acceleration of an atom with a light-pulse atom interferometer, Applied Physics B Photophysics and Laser Chemistry, vol.65, issue.5, pp.321-332, 1992.
DOI : 10.1007/BF00325375

K. A. Moler, D. S. Weiss, M. Kasevich, and S. Chu, Theoretical analysis of velocity-selective Raman transitions, Physical Review A, vol.45, issue.1, p.342, 1992.
DOI : 10.1103/PhysRevA.45.342

G. Santarelli, A. Clairon, S. N. Lea, and G. M. Tino, Heterodyne optical phase-locking of extended-cavity semiconductor lasers at 9 GHz, Optics Communications, vol.104, issue.4-6, pp.339-344, 1994.
DOI : 10.1016/0030-4018(94)90567-3

F. Yver-leduc, P. Cheinet, J. Fils, A. Clairon, N. Dimarcq et al., Reaching the quantum noise limit in a high-sensitivity cold-atom inertial sensor, Journal of Optics B: Quantum and Semiclassical Optics, vol.5, issue.2, pp.136-142, 2003.
DOI : 10.1088/1464-4266/5/2/371

A. Mann, C. Sheng, and A. Luiten, Cryogenic sapphire oscillator with exceptionally high frequency stability, IEEE Transactions on Instrumentation and Measurement, vol.50, issue.2, p.519, 2001.
DOI : 10.1109/19.918181

E. M. Rasel, M. K. Oberthaler, H. Batelaan, J. Schmiedmayer, and A. Zeilinger, Atom Wave Interferometry with Diffraction Gratings of Light, Physical Review Letters, vol.75, issue.14, p.2633, 1995.
DOI : 10.1103/PhysRevLett.75.2633

D. M. Giltner, R. W. Mcgowan, and S. A. Lee, Atom Interferometer Based on Bragg Scattering from Standing Light Waves, Physical Review Letters, vol.75, issue.14, p.2638, 1995.
DOI : 10.1103/PhysRevLett.75.2638

O. Carnal, J. Et-mlynek, and . Young, Young???s double-slit experiment with atoms: A simple atom interferometer, Physical Review Letters, vol.66, issue.21, pp.2689-2692, 1991.
DOI : 10.1103/PhysRevLett.66.2689

D. W. Keith, C. R. Ekstrom, Q. A. Turchette, and D. E. Pritchard, An interferometer for atoms, Physical Review Letters, vol.66, issue.21, pp.2693-2696, 1991.
DOI : 10.1103/PhysRevLett.66.2693

F. Riehle, . Kister-th, A. Witte, J. Helmcke, and . Et-bordé-ch, Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer, Physical Review Letters, vol.67, issue.2, pp.177-180, 1991.
DOI : 10.1103/PhysRevLett.67.177

M. Kasevich and S. Chu, Atomic interferometry using stimulated Raman transitions, Physical Review Letters, vol.67, issue.2, pp.181-184, 1991.
DOI : 10.1103/PhysRevLett.67.181

A. Peters, K. Y. Chung, and S. Chu, High-precision gravity measurements using atom interferometry, Metrologia, vol.38, issue.1, pp.38-63, 2001.
DOI : 10.1088/0026-1394/38/1/4

J. M. Mcguirk, G. T. Foster, J. B. Fixler, M. J. Snadden, and M. A. Et-kasevich, Sensitive absolute-gravity gradiometry using atom interferometry, Physical Review A, vol.65, issue.3, pp.33608-33609, 2002.
DOI : 10.1103/PhysRevA.65.033608

T. L. Gustavson, P. Bouyer, and M. A. Et-kasevich, Precision Rotation Measurements with an Atom Interferometer Gyroscope, Physical Review Letters, vol.78, issue.11, pp.2046-2049, 1997.
DOI : 10.1103/PhysRevLett.78.2046

R. Bingham, « Assesment Study report», 2000.

A. Clairon, L. Ph, G. Santarelli, S. Ghezali, S. N. Lea et al., A cesium fountain frequency standard: preliminary results, IEEE Transactions on Instrumentation and Measurement, vol.44, issue.2, pp.128-131, 1995.
DOI : 10.1109/19.377790

B. J. Ch, M. Ducloy, E. Giacobino, and G. Et-camy, Atom interferometry and laser spectroscopy », dans Lasers Spectroscopy X, World Scientific, pp.239-245, 1991.

B. Canuel, F. Leduc, D. Holleville, A. Gauguet, J. Fils et al., Six-Axis Inertial Sensor Using Cold-Atom Interferometry, Physical Review Letters, vol.97, issue.1, pp.10402-10403, 2006.
DOI : 10.1103/PhysRevLett.97.010402

A. Ch and . J. Et-bordé-ch, « exact phase shift for atom interferometry, Phys. Lett. A, vol.306, pp.277-284, 2003.

T. L. Gustavson, A. Landragin, and M. A. Et-kasevich, Rotation sensing with a dual atom-interferometer Sagnac gyroscope, Classical and Quantum Gravity, vol.17, issue.12, pp.1-14, 2000.
DOI : 10.1088/0264-9381/17/12/311

F. Yver-leduc, « Caractérisation d'un capteur inertiel à atomes froids », thèse de doctorat de l'université de Paris XI, 2004.

J. Fils, F. Leduc, P. Bouyer, D. Holleville, N. Dimarcq et al., Influence of optical aberrations in an atomic gyroscope, The European Physical Journal D, vol.54, issue.3, pp.257-260, 2005.
DOI : 10.1140/epjd/e2005-00255-9

URL : https://hal.archives-ouvertes.fr/hal-00005869

P. Cheinet, F. Pereira-dos-santos, T. Petelski, L. Gouët, J. Therkildsen et al., Compact laser system for atom interferometry, Compact laser system for atom interferometry, pp.643-646, 2006.
DOI : 10.1007/s00340-006-2266-2

]. F. Bibliographie, I. Allard, M. Maksimovic, . Abgrall, . Ph et al., Automatic system to control the operation of an extended cavity diode laser, pp.75-76, 2004.

C. J. Antoine and . Bordé, Quantum theory of atomic clocks and gravito-inertial sensors: an update, Journal of Optics B: Quantum and Semiclassical Optics, vol.5, issue.2, pp.199-207, 2003.
DOI : 10.1088/1464-4266/5/2/380

]. O. Avenel, P. Hakonen, and E. Varoquaux, Detection of the Rotation of the Earth with a Superfluid Gyrometer, Physical Review Letters, vol.78, issue.19, pp.3602-3605, 1997.
DOI : 10.1103/PhysRevLett.78.3602

]. X. Baillard, A. Gauguet, S. Bize, P. Lemonde, . Ph et al., Interference-filter-stabilized external-cavity diode lasers, Optics Communications, vol.266, issue.2, pp.266-268, 2006.
DOI : 10.1016/j.optcom.2006.05.011

]. S. Bize, Tests fondamentaux à l'aide d'horloges à atomes froids de rubidium et de Césium, 2001.

. J. Ch and . Bordé, Atomic interferometry with internal state labelling, Physics Letters A, vol.140, pp.10-12, 1989.

. J. Ch and . Bordé, Atomic interferometry and laser spectroscopy, Laser Spectroscopy, pp.239-245, 1991.

. J. Ch and . Bordé, Quantum theory of atom wave beam-splitters and application to multidimensional atomic gravito-inertial sensors, General Relativity and Gravitation, vol.36, pp.475-502, 2004.

]. P. Featonby, A. Virdis, A. Landragin, B. Canuel, and F. Leduc, Procédé et appareil de mesure de vitesse de rotation par interférométrie atomique

]. B. Canuel, F. Leduc, D. Holleville, A. Gauguet, J. Fils et al., Six-Axis Inertial Sensor Using Cold-Atom Interferometry, Physical Review Letters, vol.97, issue.1, p.10402, 2006.
DOI : 10.1103/PhysRevLett.97.010402

]. O. Carnal and J. Mlynek, Young???s double-slit experiment with atoms: A simple atom interferometer, Physical Review Letters, vol.66, issue.21, p.2689, 1991.
DOI : 10.1103/PhysRevLett.66.2689

]. P. Cheinet, B. Canuel, F. Pereira-dos-santos, A. Gauguet, F. Leduc et al., Measurement of the Sensitivity Function in a Time-Domain Atomic Interferometer, IEEE Transactions on Instrumentation and Measurement, vol.57, issue.6, 2005.
DOI : 10.1109/TIM.2007.915148

]. W. Chow, The ring laser gyro, Reviews of Modern Physics, vol.57, issue.1, p.61, 1985.
DOI : 10.1103/RevModPhys.57.61

]. M. Kasevich and S. Chu, Atomic interferometry using stimulated Raman transitions, Physical Review Letters, vol.67, issue.2, p.181, 1991.
DOI : 10.1103/PhysRevLett.67.181

]. P. Cladé, E. De-mirandes, M. Cadoret, S. Guellati-khélifa, C. Schwob et al., Determination of the Fine Structure Constant Based on Bloch Oscillations of Ultracold Atoms in a Vertical Optical Lattice, Physical Review Letters, vol.96, issue.3, p.33001, 2006.
DOI : 10.1103/PhysRevLett.96.033001

]. P. Cladé, E. De-mirandes, M. Cadoret, S. Guellati-khélifa, C. Schwob et al., Determination of the Fine Structure Constant Based on Bloch Oscillations of Ultracold Atoms in a Vertical Optical Lattice, Physical Review Letters, vol.96, issue.3, p.33001, 2006.
DOI : 10.1103/PhysRevLett.96.033001

]. A. Clairon, C. Salomon, S. Guellati, and W. Phillips, Ramsey Resonance in a Zacharias Fountain, Europhysics Letters (EPL), vol.16, issue.2, p.165, 1991.
DOI : 10.1209/0295-5075/16/2/008

]. A. Clairon, P. Laurent, G. Santarelli, S. Ghezali, S. N. Lea et al., A cesium fountain frequency standard: preliminary results, IEEE Transactions on Instrumentation and Measurement, vol.44, issue.2, pp.128-131, 1995.
DOI : 10.1109/19.377790

]. J. Clauser, Ultra-high sensitivity accelerometers and gyroscopes using neutral atom matter-wave interferometry, Physica B+C, vol.151, issue.1-2, p.262, 1988.
DOI : 10.1016/0378-4363(88)90176-3

. Cohen-tannoudji-1977-]-c, B. Cohen-tannoudji, F. Diu, and . Laloë, Mécanique Quantique, 1977.

]. R. Colella, A. W. Overhauser, and S. A. Werner, Observation of Gravitationally Induced Quantum Interference, Physical Review Letters, vol.34, issue.23, pp.1472-1474, 1975.
DOI : 10.1103/PhysRevLett.34.1472

]. J. Dalibard and C. Cohen-tannoudji, Laser cooling below the Doppler limit by polarization gradients: simple theoretical models, Journal of the Optical Society of America B, vol.6, issue.11, p.2023, 1989.
DOI : 10.1364/JOSAB.6.002023

]. C. Davisson and H. Germer, The Scattering of Electrons by a Single Crystal of Nickel, Nature, vol.119, issue.2998, pp.558-560, 1927.
DOI : 10.1038/119558a0

]. G. Dick, Local Oscillator induced instabilities in trapped ion frequency standards, Proc. Nineteenth Annual Precise Time and Time Interval, pp.133-147, 1987.

]. P. Dirac, The Fundamental Equations of Quantum Mechanics, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, vol.109, issue.752, p.744, 1925.
DOI : 10.1098/rspa.1925.0150

]. M. Drewsen, . Ph, A. Laurent, G. Nadir, A. Santarelli et al., Investigation of sub-Doppler cooling effects in a cesium magneto-optical trap, Applied Physics B Lasers and Optics, vol.70, issue.3, p.283, 1994.
DOI : 10.1007/BF01081396

]. B. Dubetsky and M. A. Kasevich, Atom interferometer as a selective sensor of rotation or gravity, Physical Review A, vol.74, issue.2, p.23615, 2006.
DOI : 10.1103/PhysRevA.74.023615

]. M. Fattori, G. Lamporesi, T. Petelski, J. Stuhler, and G. M. Tino, Towards an atom interferometric determination of the Newtonian gravitational constant, Physics Letters A, vol.318, issue.3, p.184, 2003.
DOI : 10.1016/j.physleta.2003.07.011

]. J. Fils, F. Leduc, P. Bouyer, D. Holleville, N. Dimarcq et al., Influence of optical aberrations in an atomic gyroscope, The European Physical Journal D, vol.54, issue.3, pp.257-260, 2005.
DOI : 10.1140/epjd/e2005-00255-9

URL : https://hal.archives-ouvertes.fr/hal-00005869

]. J. Fixler, G. T. Foster, J. M. Mcguirk, and M. A. Kasevich, Atom Interferometer Measurement of the Newtonian Constant of Gravity, Science, vol.315, issue.5808, pp.74-77, 2006.
DOI : 10.1126/science.1135459

]. J. Le-gouët, P. Le-gouët, J. Cheinet, D. Kim, A. Holleville et al., Influence of lasers propagation delay on the sensitivity of atom interferometers, The European Physical Journal D, vol.84, issue.3, p.701023, 2006.
DOI : 10.1140/epjd/e2007-00218-2

]. T. Gustavson, P. Bouyer, and M. A. Kasevich, Precision Rotation Measurements with an Atom Interferometer Gyroscope, Physical Review Letters, vol.78, issue.11, p.2046, 1997.
DOI : 10.1103/PhysRevLett.78.2046

]. T. Gustavson, P. Bouyer, and M. A. Kasevich, A dual atomic beam matter-wave gyroscope, Proc. SPIE, p.62, 1998.

]. T. Gustavson, A. Landragin, and M. A. Kasevich, Rotation sensing with a dual atom-interferometer Sagnac gyroscope, Classical and Quantum Gravity, vol.17, issue.12, pp.1-14, 2000.
DOI : 10.1088/0264-9381/17/12/311

]. J. Hall, L. Hollberg, T. Baer, H. G. Robinson-henry, and C. , Optical heterodyne saturation spectroscopy, Applied Physics Letters, vol.39, issue.9, pp.680-698, 1981.
DOI : 10.1063/1.92867

]. D. Keith, C. R. Ekstrom, Q. A. Turchette, and D. E. Pritchard, An interferometer for atoms, Physical Review Letters, vol.66, issue.21, p.2693, 1991.
DOI : 10.1103/PhysRevLett.66.2693

S. Kobayashi and T. Kimura, Injection locking in AlGaAs semiconductor laser, IEEE Journal of Quantum Electronics, vol.17, issue.5, pp.681-689, 1981.
DOI : 10.1109/JQE.1981.1071166

]. G. Lucas-leclin and . Lucas-leclin, Importance des propriétés spectrales des lasers pour les performances des horloges atomiques à pompage optique, 1998.

H. Marion, F. Pereira-dos-santos, M. Abgrall, S. Zhang, Y. Sortais et al., Search for Variations of Fundamental Constants using Atomic Fountain Clocks, Physical Review Letters, vol.90, issue.15, p.150801, 2003.
DOI : 10.1103/PhysRevLett.90.150801

URL : https://hal.archives-ouvertes.fr/hal-00002552

]. L. Marton, Electron Interferometer, Physical Review, vol.85, issue.6, p.1057, 1952.
DOI : 10.1103/PhysRev.85.1057

]. J. Mcguirk, G. T. Foster, J. B. Fixler, M. J. Snadden, and M. A. Kasevich, Sensitive absolute-gravity gradiometry using atom interferometry, Physical Review A, vol.65, issue.3, p.33608, 2002.
DOI : 10.1103/PhysRevA.65.033608

D. S. Weiss, M. Kasevich, and S. Chu, Theoretical analysis of velocityselective Raman transitions, Phys. Rev. A, vol.45, p.342, 1992.

]. A. Peters, K. Y. Chung, and S. Chu, High-precision gravity measurements using atom interferometry, Metrologia, vol.38, issue.1, pp.25-61, 2001.
DOI : 10.1088/0026-1394/38/1/4

]. E. Raab, M. Prentiss, A. Cable, S. Chu, and D. E. Pritchard, Trapping of Neutral Sodium Atoms with Radiation Pressure, Physical Review Letters, vol.59, issue.23, p.2631, 1987.
DOI : 10.1103/PhysRevLett.59.2631

F. Norman and . Ramsey, A Molecular Beam Resonance Method with Separated Oscillating Fields, Phys. Rev, vol.78, p.695, 1950.

]. H. Rauch and W. Treimer, Test of a single crystal neutron interferometer, Physics Letters A, vol.47, issue.5, pp.369-371, 1974.
DOI : 10.1016/0375-9601(74)90132-7

]. F. Riehle, . Th, A. Kisters, J. Witte, C. J. Helmcke et al., Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer, Physical Review Letters, vol.67, issue.2, p.177, 1991.
DOI : 10.1103/PhysRevLett.67.177

]. M. Sagnac, Compte rendus de l'académie des sciences, pp.708-1410, 1913.

]. D. Sesko, T. Walker, C. Monroe, A. Gallagher, and C. Wieman, Collisional losses from a light-force atom trap, Physical Review Letters, vol.63, issue.9, p.961, 1987.
DOI : 10.1103/PhysRevLett.63.961

]. G. Stedman, Z. Li, C. H. Rowe, A. D. Mcgregor, and H. R. Bilger, Harmonic analysis in a large ring laser with backscatter-induced pulling, Physical Review A, vol.51, issue.6, pp.4944-4958, 1995.
DOI : 10.1103/PhysRevA.51.4944

]. P. Storey and C. C. Tannoudji, The feynmann path integral approach to atomic interferometry : A tutorial, J. Phys. II, vol.4, 1994.

]. Leduc-2004 and . Leduc, Caractérisation d'un capteur inertiel à atomes froids, thèse de doctorat de l'université Paris XI, 2004.

]. D. Weiss, B. C. Young, and S. Chu, Precision measurement of ?/m Cs based on photon recoil using laser-cooled atoms and atomic interferometry, Applied Physics B Lasers and Optics, vol.72, issue.3, pp.59-217, 1994.
DOI : 10.1007/BF01081393

]. A. Wicht, J. M. Henlsey, E. Sarajlic, and S. Chu, A Preliminary Measurement of the Fine Structure Constant Based on Atom Interferometry, Condensation and Coherence in Condensed Matter, pp.82-88, 2002.
DOI : 10.1142/9789812791269_0014