S. Patankar, Numerical Heat Transfer and Fluid Flow. Hemisphere, 1980.

B. Leonard, A stable and accurate convective modelling procedure based on quadratic upstream interpolation, Computer Methods in Applied Mechanics and Engineering, vol.19, issue.1, pp.59-98, 1991.
DOI : 10.1016/0045-7825(79)90034-3

M. Peric, A finite volume method for the prediction of three dimensional fluid flow in complex ducts

H. Jasak, Error anamysis and estimation for the finitie volume method with applications to fluid flows, 1996.

C. Hirsch, Numerical computation of internal and external flows, 1991.

S. Patankar and D. Spalding, A calculation procedure for heat, mass and momentum transfer in three-dimensional parabolic flows, International Journal of Heat and Mass Transfer, vol.15, issue.10, pp.1787-1806, 1972.
DOI : 10.1016/0017-9310(72)90054-3

R. Issa, Solution of the implicitly discretised fluid flow equations by operator-splitting, Journal of Computational Physics, vol.62, issue.1, pp.40-65, 1986.
DOI : 10.1016/0021-9991(86)90099-9

M. Lowe and P. Kutt, Refraction through cylindrical tubes, Experiments in Fluids, vol.13, issue.5, pp.50-54, 1992.
DOI : 10.1007/BF00209503

D. Liepsch, G. Thurston, and M. Lee, Studies of fluids simulating blood-like rheological properties and applications in models of arterial branches, Biorheology, vol.28, pp.39-52, 1991.

D. Liepsch, An introduction to biofluid mechanics???basic models and applications, Journal of Biomechanics, vol.35, issue.4, pp.145-435, 2002.
DOI : 10.1016/S0021-9290(01)00185-3

F. Gijsen, F. Van-de-vosse, and J. Janssen, The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model, Journal of Biomechanics, vol.32, issue.6, pp.145-435, 1999.
DOI : 10.1016/S0021-9290(99)00015-9

F. Gijsen, Modelling of wall shear stress in large arteries, 1998.

K. Brookshier and J. Tarbell, Evaluation of a transparent blood analog fluid ? aqueous xanthan gum glycerine, Biorheology, vol.30, pp.107-116, 1993.

M. Pohl, M. Wendt, S. Werner, B. Koch, and D. Lerche, In Vitro Testing of Artificial Heart Valves: Comparison Between Newtonian and Non-Newtonian Fluids, Artificial Organs, vol.34, issue.1, pp.37-46, 1996.
DOI : 10.1111/j.1525-1594.1996.tb04416.x

R. Chen and L. Fan, Particle image velocimetry for characterizing the flow structure in three-dimensional gas-liquid-solid fluidized beds, Chemical Engineering Science, vol.47, issue.13-14, pp.3615-3622, 1992.
DOI : 10.1016/0009-2509(92)85077-O

O. Uzol, Y. Chow, J. Katz, and C. Meneveau, Unobstructed PIV measurements within an axial turbo-pump using liquid and blades with matched refractive indices, Proceeding of 4 th International Symposium on Particle Image Velocimetry, pp.17-19, 2001.

T. Narrow, M. Yoda, and S. Abdel-khalik, A simple model for the refractive index of sodium iodide aqueous solutions, Experiments in Fluids, vol.28, issue.3, pp.282-283, 2000.
DOI : 10.1007/s003480050389

H. Simon, H. Leo, J. Carberry, and A. Yoganathan, Investigation of the leakage flow fields of two bileaflet mechanical heart valves under aortic conditions. Proceeding of the European Society of Biomechanics, s-Hertogenbosch, 2004.

D. Jan, A. Shapiro, and R. Kamm, Some features of oscillatory flow in a model bifurcation, J. Appl. Physiol, vol.67, pp.147-159, 1989.

H. Hooper, Experimental studies of the hemodynamics in abdominal aortic aneurysms, 1992.

C. Liu, C. Vafidis, and J. Whitelaw, Flow in the coolant passages of an internal combustion engine cylinder head, Experiments in Fluids, vol.68, issue.1, pp.50-54, 1990.
DOI : 10.1007/BF00187872

A. Awtrey and R. Connick, The absorption spectra of iodure components, J of Am. Chem. Society, vol.79, pp.1842-1843, 1951.

S. Chien, S. Usami, R. Dellenback, and M. Gregersen, Shear-dependent deformation of erythrocytes in rheology of human blood, Am J Physiol, vol.219, pp.136-142, 1970.

R. Adrian, Particle-Imaging Techniques for Experimental Fluid Mechanics, Annual Review of Fluid Mechanics, vol.23, issue.1, pp.261-304, 1991.
DOI : 10.1146/annurev.fl.23.010191.001401

S. Alshihabi, Y. Chang, J. Frangos, and J. Tarbell, Shear Stress-Induced Release of PGE2and PGI2by Vascular Smooth Muscle Cells, Biochemical and Biophysical Research Communications, vol.224, issue.3, pp.808-814, 1996.
DOI : 10.1006/bbrc.1996.1104

B. Armaly, F. Durst, B. Schonung, and J. Pereira, Experimental and theoretical investigation of backward-facing step flow, Journal of Fluid Mechanics, vol.86, issue.-1, pp.473-496, 1983.
DOI : 10.1017/S0022112067001892

T. Asakura and T. Karino, Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries, Circulation Research, vol.66, issue.4, pp.1045-1066, 1990.
DOI : 10.1161/01.RES.66.4.1045

D. Ashby, G. Dangas, R. Mehran, A. Lansky, R. Narasimaiah et al., Comparison of clinical outcomes using stents versus no stents after percutaneous coronary intervention for proximal left anterior descending versus proximal right and left circumflex coronary arteries, The American Journal of Cardiology, vol.89, issue.10, pp.1162-1166, 2002.
DOI : 10.1016/S0002-9149(02)02297-X

A. Awtrey and R. Connick, The absorption spectra of iodure components, J of Am. Chem. Society, vol.79, pp.1842-1843, 1951.

J. Baaijens, A. Van-steenhoven, and J. Janssen, Numerical analysis of steady generalized Newtonian blood flow in a 2D model of the carotid artery bifurcation, Biorheology, vol.30, pp.63-74, 1993.

X. Bao, C. Lu, and J. Frangos, Temporal Gradient in Shear But Not Steady Shear Stress Induces PDGF-A and MCP-1 Expression in Endothelial Cells : Role of NO, NF??B, and egr-1, Arteriosclerosis, Thrombosis, and Vascular Biology, vol.19, issue.4, pp.996-1003, 1999.
DOI : 10.1161/01.ATV.19.4.996

A. Barakat and E. Cheng, Numerical simulation of fluid mechanical disturbance induced by intravascular stents, Proceedings of ICMMB-11, 2000.

K. Barbee, P. Davies, and R. Lal, Shear stress-induced reorganization of the surface topography of living endothelial cells imaged by atomic force microscopy, Circulation Research, vol.74, issue.1, pp.163-71, 1994.
DOI : 10.1161/01.RES.74.1.163

P. Barragan, R. Rieu, V. Garitey, P. Roquebert, J. Sainsous et al., Elastic recoil of coronary stents: A comparative analysis, Catheterization and Cardiovascular Interventions, vol.98, issue.1, pp.112-119, 2000.
DOI : 10.1002/(SICI)1522-726X(200005)50:1<112::AID-CCD25>3.0.CO;2-X

N. Benard, D. Coisne, E. Donal, and R. Perrault, Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress, Journal of Biomechanics, vol.36, issue.7, pp.991-998, 2003.
DOI : 10.1016/S0021-9290(03)00068-X

J. Berry, J. Moore, V. Newman, and W. Routh, In vitro flow visualization in stented arterial segments, J of Vascular Invest, vol.3, pp.63-68, 1997.

J. Berry, A. Santamarina, J. Moore, . Jr, S. Roychowdhury et al., Experimental and Computational Flow Evaluation of Coronary Stents, Annals of Biomedical Engineering, vol.28, issue.4, pp.386-398, 2000.
DOI : 10.1114/1.276

B. Berthier, R. Bouzerar, and C. Legallais, Blood flow patterns in an anatomically realistic coronary vessel: influence of three different reconstruction methods, Journal of Biomechanics, vol.35, issue.10, pp.1347-1356, 2002.
DOI : 10.1016/S0021-9290(02)00179-3

C. Briguori, C. Sarais, P. Pagnotta, F. Liistro, M. Montorfano et al., In-stent restenosis in small coronary arteries, Journal of the American College of Cardiology, vol.40, issue.3, pp.403-409, 2002.
DOI : 10.1016/S0735-1097(02)01989-7

K. Brookshier and J. Tarbell, Evaluation of a transparent blood analog fluid -aqueous xanthan gum glycerine, Biorheology, vol.30, pp.107-116, 1993.

C. Brown, L. Leverett, C. Lewis, C. Alfrey, and J. Hellums, Morphological, biochemical, and functional changes in human platelets subjected to shear stress, J Lab Clin Med, vol.86, pp.462-71, 1975.

J. Buchanan, . Jr, C. Kleinstreuer, and J. Comer, Rheological effects on pulsatile hemodynamics in a stenosed tube, Computers & Fluids, vol.29, issue.6, pp.695-724, 2000.
DOI : 10.1016/S0045-7930(99)00019-5

D. Calluaud, Développement d'une méthode de mesures tridimensionnelles par PIV stéréoscopique, Thèse de doctorat de l, 2003.

G. Campbell and J. Campbell, Smooth muscle phenotypic changes in arterial wall homeostasis: Implications for the pathogenesis of atherosclerosis, Experimental and Molecular Pathology, vol.42, issue.2, pp.139-162, 1984.
DOI : 10.1016/0014-4800(85)90023-1

P. Cannon, M. Weiss, and R. Sciacca, Myocardial blood flow in coronary artery disease: Studies at rest and during stress with inert gas washout techniques, Progress in Cardiovascular Diseases, vol.20, issue.2, pp.95-120, 1977.
DOI : 10.1016/0033-0620(77)90002-0

R. Chen and L. Fan, Particle image velocimetry for characterizing the flow structure in three-dimensional gas-liquid-solid fluidized beds, Chemical Engineering Science, vol.47, issue.13-14, pp.3615-3622, 1992.
DOI : 10.1016/0009-2509(92)85077-O

G. Cheng, W. Briggs, D. Gerson, P. Libby, A. Grodzinsky et al., Mechanical Strain Tightly Controls Fibroblast Growth Factor-2 Release From Cultured Human Vascular Smooth Muscle Cells, Circulation Research, vol.80, issue.1, pp.28-36, 1997.
DOI : 10.1161/01.RES.80.1.28

S. Chien, S. Usami, R. Dellenback, and M. Gregersen, Shear-dependent deformation of erythrocytes in rheology of human blood, Am J Physiol, vol.219, pp.136-142, 1970.

G. Chilsom and D. Steinberg, The oxidative modification hypothesis of artherogenesis : An overview. Free Rad, Biol. Med, vol.28, pp.1815-1826, 2000.

Y. Cho and K. Kensey, Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flows, Biorheology, vol.28, pp.241-62, 1991.

G. Danzi, L. Fiocca, C. Capuano, S. Predolini, and E. Quaini, Acute stent recoil: In vivo evaluation of different stent designs, Catheterization and Cardiovascular Interventions, vol.76, issue.2, pp.147-153, 2001.
DOI : 10.1002/1522-726X(200102)52:2<147::AID-CCD1038>3.0.CO;2-B

P. Davies, Flow-mediated endothelial mechanotransduction, Physiol. Rev, vol.75, pp.519-560, 1995.

R. Dougal, M. Mcclean, and E. Eigler, Stent design : implications for restenosis, Reviews in cardiovascular medicine, vol.3, pp.16-22, 2002.

J. Downing and D. Ku, Effects of Frictional Losses and Pulsatile Flow on the Collapse of Stenotic Arteries, Journal of Biomechanical Engineering, vol.119, issue.3, pp.317-324, 1997.
DOI : 10.1115/1.2796096

F. Etave, G. Finet, M. Boivin, J. Boyer, G. Rioufol et al., Mechanical properties of coronary stents determined by using finite element analysis, Journal of Biomechanics, vol.34, issue.8, pp.1065-1075, 2001.
DOI : 10.1016/S0021-9290(01)00026-4

URL : https://hal.archives-ouvertes.fr/hal-00475353

N. Fatouraee, X. Deng, D. Champlain, A. Guidoin, and R. , Numerical simulation of lipid transport through arterial stenoses. Transaction of ASME Bioengineering Conference, 1998.

J. Ferziger and M. Peric, Computational methods for fluid dynamics. 3rd rev, 2002.

D. Fischman, M. Leon, D. Baim, R. Schatz, M. Savage et al., A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease, New England Journal of Medicine, vol.331, issue.8, pp.496-501, 1994.
DOI : 10.1056/NEJM199408253310802

K. Fox, M. Cowie, and D. Wood, Coronary artery disease as the cause of incident heart failure in the population, European Heart Journal, vol.22, issue.3, pp.228-236, 2001.
DOI : 10.1053/euhj.2000.2289

A. Frank, P. Walsh, J. Moore, and . Jr, Computational Fluid Dynamics and Stent Design, Artificial Organs, vol.13, issue.7, pp.614-621, 2002.
DOI : 10.1114/1.276

D. Fry, Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients, Circulation Research, vol.22, issue.2, pp.165-197, 1968.
DOI : 10.1161/01.RES.22.2.165

Y. C. Fung, BIOMECHANICS, SHOCK, vol.9, issue.2, 1997.
DOI : 10.1097/00024382-199802000-00018

J. Garasic, E. Edelman, J. Squire, P. Seifert, M. Williams et al., Stent and Artery Geometry Determine Intimal Thickening Independent of Arterial Injury, Circulation, vol.101, issue.7, pp.812-818, 2000.
DOI : 10.1161/01.CIR.101.7.812

F. Gijsen, E. Allanic, F. Van-de-vosse, and J. Janssen, The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90?? curved tube, Journal of Biomechanics, vol.32, issue.7, pp.705-718, 1999.
DOI : 10.1016/S0021-9290(99)00014-7

F. Gijsen, F. Van-de-vosse, and J. Janssen, Wall shear stress in backward-facing step flow of a red blood cell suspension, Biorheology, vol.35, issue.4-5, pp.263-279, 1998.
DOI : 10.1016/S0006-355X(99)80010-9

F. Gijsen, Modelling of wall shear stress in large arteries, 1998.

F. Gijsen, F. Van-de-vosse, and J. Janssen, The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model, Journal of Biomechanics, vol.32, issue.6, pp.145-435, 1999.
DOI : 10.1016/S0021-9290(99)00015-9

M. Gimbrone, J. Topper, T. Nagel, K. Anderson, and G. Garcia-cardena, Endothelial Dysfunction, Hemodynamic Forces, and Atherogenesisa, Annals of the New York Academy of Sciences, vol.93, issue.2, pp.230-240, 2000.
DOI : 10.1111/j.1749-6632.2000.tb06318.x

C. Glover, L. Mcintire, L. Leverett, J. Hellums, C. Brown et al., Effect of shear stress on clot structure formation, Trans Am Soc Artif Intern Organs, vol.20, pp.463-468, 1974.

A. Gojova and A. Barakat, Vascular endothelial wound closure under shear stress: role of membrane fluidity and flow-sensitive ion channels, Journal of Applied Physiology, vol.98, issue.6, 2005.
DOI : 10.1152/japplphysiol.01136.2004

A. Guyton and J. Hall, Textbook of Medical Physiology, 1996.

M. Haga, A. Yamashita, J. Paszkowiak, B. Sumpio, and A. Dardik, Oscillatory shear stress increases smooth muscle cell proliferation and akt phosphorylation, Journal of Vascular Surgery, vol.37, issue.6, pp.1277-1284, 2003.
DOI : 10.1016/S0741-5214(03)00329-X

F. Henry, Simulation of flow through model stented arteries Proceeding of ASME Bioengineering Conference, pp.329-330, 2001.

C. Hirsch, Numerical computation of internal and external flows, 1991.

R. Hoffmann, C. Jansen, A. Konig, P. Haager, G. Kerckhoff et al., Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study, European Heart Journal, vol.22, issue.21, pp.2007-2021, 2001.
DOI : 10.1053/euhj.2001.2606

R. Hoffmann, G. Mintz, G. Dussaillant, J. Popma, A. Pichard et al., Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study, Circulation, vol.94, issue.6, pp.1247-1254, 1996.
DOI : 10.1161/01.CIR.94.6.1247

H. Hooper, Experimental studies of the hemodynamics in abdominal aortic aneurysms, 1992.

H. Hsieh, N. Li, and J. Frangos, Shear stress increases endothelial platelet-derived growth factor mRNA levels, Am J Physiol, vol.260, pp.642-646, 1991.

P. Huang, J. Feng, H. Hu, and D. Joseph, Direct simulation of the motion of solid particles in Couette and Poiseuille flows of viscoelastic fluids, Journal of Fluid Mechanics, vol.343, pp.73-94, 1997.
DOI : 10.1017/S0022112097005764

R. Issa, Solution of the implicitly discretised fluid flow equations by operator-splitting, Journal of Computational Physics, vol.62, issue.1, pp.40-65, 1986.
DOI : 10.1016/0021-9991(86)90099-9

D. Jan, A. Shapiro, and R. Kamm, Some features of oscillatory flow in a model bifurcation, J. Appl. Physiol, vol.67, pp.147-159, 1989.

H. Jasak, Error anamysis and estimation for the finitie volume method with applications to fluid flows, 1996.

Y. Jiang, K. Kohara, and K. Hiwada, Association Between Risk Factors for Atherosclerosis and Mechanical Forces in Carotid Artery, Stroke, vol.31, issue.10, pp.2319-2326, 2000.
DOI : 10.1161/01.STR.31.10.2319

B. Johnston, P. Johnston, S. Corney, and D. Kilpatrick, Non-Newtonian blood flow in human right coronary arteries: steady state simulations, Journal of Biomechanics, vol.37, issue.5, pp.709-720, 2004.
DOI : 10.1016/j.jbiomech.2003.09.016

B. Johnston, P. Johnston, S. Corney, and D. Kilpatrick, Non-Newtonian blood flow in human right coronary arteries: Transient simulations, Journal of Biomechanics, vol.39, issue.6, 2005.
DOI : 10.1016/j.jbiomech.2005.01.034

A. Kastrati, J. Mehilli, J. Dirschinger, J. Pache, K. Ulm et al., Restenosis after coronary placement of various stent types, The American Journal of Cardiology, vol.87, issue.1, pp.34-39, 2001.
DOI : 10.1016/S0002-9149(00)01268-6

R. Keane and R. Adrian, Theory of cross-correlation analysis of PIV images, Applied Scientific Research, vol.23, issue.3, pp.191-215, 1992.
DOI : 10.1007/BF00384623

I. Krieger and T. Dougherty, A Mechanism for Non???Newtonian Flow in Suspensions of Rigid Spheres, Transactions of the Society of Rheology, vol.3, issue.1, pp.137-52, 1959.
DOI : 10.1122/1.548848

D. Ku, D. Giddens, C. Zarins, and S. Glagov, Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress, Arteriosclerosis, Thrombosis, and Vascular Biology, vol.5, issue.3, pp.293-302, 1985.
DOI : 10.1161/01.ATV.5.3.293

J. Ladisa, I. Guler, L. Olson, D. Hettrick, J. Kersten et al., Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation, Annals of Biomedical Engineering, vol.31, issue.8, pp.972-980, 2003.
DOI : 10.1114/1.1588654

J. Ladisa, L. Olson, I. Guler, D. Hettrick, S. Audi et al., Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery, Journal of Applied Physiology, vol.97, issue.1, pp.424-430, 2004.
DOI : 10.1152/japplphysiol.01329.2003

J. Ladisa, L. Olson, I. Guler, D. Hettrick, J. Kersten et al., Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models, Journal of Applied Physiology, vol.98, issue.3, pp.947-957, 2005.
DOI : 10.1152/japplphysiol.00872.2004

J. Ladisa, D. Warltier, I. Guler, J. Kersten, and P. Pagel, Stent geometry and deployment ratio influence distributions of wall shear stress : Three dimensional numerical simulations exploiting properties of an implanted stent, Proceeding of ASME Summer Bioengineering Conference, 2003.

B. Lee, J. Lee, B. Hong, B. Park, D. Kim et al., Hemodynamic Analysis of Coronary Circulation in Angulated Coronary Stenosis Following Stenting, Yonsei Medical Journal, vol.43, issue.5, pp.590-600, 2002.
DOI : 10.3349/ymj.2002.43.5.590

B. Leonard, A stable and accurate convective modelling procedure based on quadratic upstream interpolation, Computer Methods in Applied Mechanics and Engineering, vol.19, issue.1, 1991.
DOI : 10.1016/0045-7825(79)90034-3

J. Léoni, Physiopathologie de l'athérosclérose -Mécanismes et prévention de l'athérothrombose. Thèse d'état de l, 2001.

M. Levesque and R. Nerem, The Elongation and Orientation of Cultured Endothelial Cells in Response to Shear Stress, Journal of Biomechanical Engineering, vol.107, issue.4, pp.341-347, 1985.
DOI : 10.1115/1.3138567

R. Liao, N. Green, S. Chen, J. Messenger, A. Hansgen et al., Three-Dimensional Analysis of in vivo Coronary Stent ??? Coronary Artery Interactions, The International Journal of Cardiovascular Imaging formerly The International Journal of Cardiac Imaging, vol.20, issue.4, pp.305-313, 2004.
DOI : 10.1023/B:CAIM.0000041950.84736.e6

P. Lichtlen and H. Engel, Assessment of regional myocardial blood flow using the inert gas washout technique, 1979.

D. Liepsch, An introduction to biofluid mechanics???basic models and applications, Journal of Biomechanics, vol.35, issue.4, pp.145-435, 2002.
DOI : 10.1016/S0021-9290(01)00185-3

D. Liepsch, G. Thurston, and M. Lee, Studies of fluids simulating blood-like rheological properties and applications in models of arterial branches, Biorheology, vol.28, pp.39-52, 1991.

H. Lipowsky, S. Usami, and S. Chien, The distribution of blood rheological parameters in the microvasculature of cat mesentery, Circulation Research, vol.43, issue.5, pp.738-749, 1980.
DOI : 10.1161/01.RES.43.5.738

C. Liu, C. Vafidis, and J. Whitelaw, Flow in the coolant passages of an internal combustion engine cylinder head, Experiments in Fluids, vol.68, issue.1, pp.50-54, 1990.
DOI : 10.1007/BF00187872

S. Liu, D. Tang, C. Tieche, and P. Alkema, Pattern formation of vascular smooth muscle cells subject to nonuniform fluid shear stress: mediation by gradient of cell density, American Journal of Physiology - Heart and Circulatory Physiology, vol.285, issue.3, pp.1072-1080, 2003.
DOI : 10.1152/ajpheart.01009.2002

Q. Long, X. Xu, K. Ramnarine, and P. Hoskins, Numerical investigation of physiologically realistic pulsatile flow through arterial stenosis, Journal of Biomechanics, vol.34, issue.10, pp.1229-1242, 2001.
DOI : 10.1016/S0021-9290(01)00100-2

C. Loudon and A. Tordesillas, The Use of the Dimensionless Womersley Number to Characterize the Unsteady Nature of Internal Flow, Journal of Theoretical Biology, vol.191, issue.1, pp.63-78, 1998.
DOI : 10.1006/jtbi.1997.0564

M. Lowe and P. Kutt, Refraction through cylindrical tubes, Experiments in Fluids, vol.13, issue.5, pp.50-54, 1992.
DOI : 10.1007/BF00209503

R. Macalpin, A. Abbasi, G. Jr, J. Eber, and L. , Human Coronary Artery Size During Life, Radiology, vol.108, issue.3, pp.567-576, 1973.
DOI : 10.1148/108.3.567

A. Malek, G. Gibbons, V. Dzau, and S. Izumo, Fluid shear stress differentially modulates expression of genes encoding basic fibroblast growth factor and platelet-derived growth factor B chain in vascular endothelium., Journal of Clinical Investigation, vol.92, issue.4, pp.2013-2021, 1993.
DOI : 10.1172/JCI116796

A. Malek and S. Izumo, Mechanism of endothelial cell shape change and cytoskeletal remodelling in response to fluid shear stress, J. of Cell Science, vol.109, pp.713-726, 1996.

M. Malek and . Izumo, Physiological fluid shear stress causes downregulation of endothelin-1 mRNA in bovine aortic endhothelium, Am J Physiol Cell Physiol, vol.263, pp.389-396, 1992.

S. Matsuo, M. Tsuruta, M. Hayano, Y. Immamura, Y. Eguchi et al., Phasic coronary artery flow velocity determined by Doppler flowmeter catheter in aortic stenosis and aortic regurgitation, The American Journal of Cardiology, vol.62, issue.13, pp.917-922, 1988.
DOI : 10.1016/0002-9149(88)90893-4

D. Mcdonald, Blood Flow in Arteries, The American Journal of the Medical Sciences, vol.245, issue.1, 1974.
DOI : 10.1097/00000441-196301000-00017

D. Mcmillan, J. Strigberger, and N. Utterback, Rapidly recovered transient flow resistance: a newly discovered property of blood, Am J Physiol, vol.253, pp.919-926, 1987.

R. Mehran, G. Dangas, and A. Abizaid, Angiographic Patterns of In-Stent Restenosis : Classification and Implications for Long-Term Outcome, Circulation, vol.100, issue.18, pp.1872-1878, 1999.
DOI : 10.1161/01.CIR.100.18.1872

A. Melling, Tracer particles and seeding for particle image velocimetry, Measurement Science and Technology, vol.8, issue.12, pp.1406-1416, 1997.
DOI : 10.1088/0957-0233/8/12/005

J. Moore, . Jr, and J. Berry, Fluid and Solid Mechanical Implications of Vascular Stenting, Annals of Biomedical Engineering, vol.30, issue.4, pp.498-508, 2002.
DOI : 10.1114/1.1458594

J. Murray and A. Lopez, Mortality by cause for eight regions of the world: Global Burden of Disease Study, The Lancet, vol.349, issue.9061, pp.1269-1276, 1997.
DOI : 10.1016/S0140-6736(96)07493-4

T. Nagel, N. Resnick, W. Atkinson, F. Dewey, and M. Gimbrone, Shear stress selectively upregulates intercellular adhesion molecule-1 expression in cultured human vascular endothelial cells., Journal of Clinical Investigation, vol.94, issue.2, pp.885-891, 1994.
DOI : 10.1172/JCI117410

T. Narrow, M. Yoda, and S. Abdel-khalik, A simple model for the refractive index of sodium iodide aqueous solutions, Experiments in Fluids, vol.28, issue.3, pp.282-283, 2000.
DOI : 10.1007/s003480050389

S. Natarajan and M. Mokhtarzadeh-dehghan, A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries, Medical Engineering & Physics, vol.22, issue.8, pp.555-566, 2000.
DOI : 10.1016/S1350-4533(00)00072-2

R. Nerem and W. Seed, An in vivo study of aortic flow disturbances, Cardiovascular Research, vol.6, issue.1, pp.1-14, 1972.
DOI : 10.1093/cvr/6.1.1

J. Nikuradse, Applied Hydro-and Aeromechanics. Prandtl, L & Tietjens, 1934.

J. Nogueira, A. Lecuona, and P. Rodriguez, Identification of a new source of peak locking, analysis and its removal in conventional and super-resolution PIV techniques, Experiments in Fluids, vol.30, issue.3, pp.309-316, 2001.
DOI : 10.1007/s003480000179

M. Noris, M. Morigi, R. Donadelli, S. Aiello, M. Foppolo et al., Nitric Oxide Synthesis by Cultured Endothelial Cells Is Modulated by Flow Conditions, Circulation Research, vol.76, issue.4, pp.536-543, 1995.
DOI : 10.1161/01.RES.76.4.536

O. 'callaghan, S. Walsh, M. Mcgloughlin, and T. , Numerical modelling of Newtonian and non-Newtonian representation of blood in a distal end-to-side vascular bypass graft anastomosis, Med Eng Phys, 2005.

J. Orford, R. Lennon, S. Melby, P. Fasseas, M. Bell et al., Frequency and correlates of coronary stent thrombosis in the modern era, Journal of the American College of Cardiology, vol.40, issue.9, pp.1567-1572, 2002.
DOI : 10.1016/S0735-1097(02)02374-4

J. Pache, A. Kastrati, J. Mehilli, H. Schuhlen, F. Dotzer et al., Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial, Journal of the American College of Cardiology, vol.41, issue.8, pp.1283-1288, 2003.
DOI : 10.1016/S0735-1097(03)00119-0

S. Patankar and D. Spalding, A calculation procedure for heat, mass and momentum transfer in three-dimensional parabolic flows, International Journal of Heat and Mass Transfer, vol.15, issue.10, pp.1787-1806, 1972.
DOI : 10.1016/0017-9310(72)90054-3

S. Patankar, Numerical Heat Transfer and Fluid Flow. Hemisphere, 1980.

J. Peacock, S. Hankins, T. Jones, and R. Lutz, Flow instabilities induced by coronary artery stents: Assessment with an in vitro pulse duplicator, Journal of Biomechanics, vol.28, issue.1, pp.17-26, 1995.
DOI : 10.1016/0021-9290(95)80003-4

K. Perktold and G. Rappitsch, Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model, Journal of Biomechanics, vol.28, issue.7, pp.845-856, 1995.
DOI : 10.1016/0021-9290(95)95273-8

M. Peric, A finite volume method for the prediction of three dimensional fluid flow in complex ducts, 1995.

M. Pohl, M. Wendt, S. Werner, B. Koch, and D. Lerche, In Vitro Testing of Artificial Heart Valves: Comparison Between Newtonian and Non-Newtonian Fluids, Artificial Organs, vol.34, issue.1, pp.37-46, 1996.
DOI : 10.1111/j.1525-1594.1996.tb04416.x

G. Poitras, L. Brizzi, and Y. Gagnon, Structure of channel flows with surface mounted ribs, Journal of Thermal Science, vol.10, issue.2, pp.213-219, 2004.
DOI : 10.1007/s11630-004-0034-3

URL : https://hal.archives-ouvertes.fr/hal-00146865

G. Pontrelli and G. Pedrizzetti, Numerical modelling of blood flow in a stented artery. Wall-fluid interactions in physiological flows, pp.173-188, 2004.

S. Prakash and C. Ethier, Requirements for Mesh Resolution in 3D Computational Hemodynamics, Journal of Biomechanical Engineering, vol.123, issue.2, pp.134-144, 2001.
DOI : 10.1115/1.1351807

D. Quemada, Rheology of concentrated disperse systems and minimum energy dissipation principle, Rheologica Acta, vol.3, issue.1, pp.82-94, 1977.
DOI : 10.1007/BF01516932

M. Quemada and . Hemorheology, Erythrocyte aggregation and non-Newtonian properties of blood: new rheological law and the validity of Casson's law for blood, C R Acad Sci Hebd Seances Acad Sci D, vol.281, pp.747-750

M. Raffel, C. Willert, and J. Kompenhans, Particle image velocimetry : A practical guide, 1998.
DOI : 10.1007/978-3-662-03637-2

R. Rieu, P. Barragan, V. Garitey, P. Roquebert, J. Fuseri et al., Assessment of the trackability, flexibility, and conformability of coronary stents: A comparative analysis, Catheterization and Cardiovascular Interventions, vol.346, issue.4, pp.496-503, 2003.
DOI : 10.1002/ccd.10583

URL : https://hal.archives-ouvertes.fr/hal-00092259

R. Rieu, P. Barragan, C. Masson, J. Fuseri, V. Garitey et al., Radial force of coronary stents: A comparative analysis, Catheterization and Cardiovascular Interventions, vol.28, issue.3, pp.380-391, 1999.
DOI : 10.1002/(SICI)1522-726X(199903)46:3<380::AID-CCD27>3.0.CO;2-J

C. Rogers and E. Edelman, Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis, Circulation, vol.91, issue.12, pp.2995-3001, 1995.
DOI : 10.1161/01.CIR.91.12.2995

C. Rogers, D. Tseng, J. Squire, and E. Edelman, Balloon-Artery Interactions During Stent Placement : A Finite Element Analysis Approach to Pressure, Compliance, and Stent Design as Contributors to Vascular Injury, Circulation Research, vol.84, issue.4, pp.378-383, 1999.
DOI : 10.1161/01.RES.84.4.378

P. Rolland, C. Mekkaoui, V. Vidal, J. Berry, J. Moore et al., Compliance Matching Stent Placement in the Carotid Artery of the Swine Promotes Optimal Blood Flow and Attenuates Restenosis, European Journal of Vascular and Endovascular Surgery, vol.28, issue.4, pp.431-438, 2004.
DOI : 10.1016/j.ejvs.2004.06.018

R. Ross, Atherosclerosis-an inflammatory disease, N. Engl. J. Med, vol.340, pp.115-126, 1999.

R. Ross, K. Ueda, P. Lichtlen, and J. Rees, Measurement of Myocardial Blood Flow in Animals and Man by Selective Injection of Radioactive Inert Gas into the Coronary Arteries, Circulation Research, vol.15, issue.1, pp.28-41, 1964.
DOI : 10.1161/01.RES.15.1.28

R. Rudic, E. Shesely, N. Madea, O. Smithies, S. Segal et al., Direct evidence for the importance of endothelium derived nitric oxide in vascular remodelling, J. Clin. Invest, vol.101, p.731736, 1998.

H. Sabbah, F. Walburn, and P. Stein, Patterns of Flow in the Left Coronary Artery, Journal of Biomechanical Engineering, vol.106, issue.3, pp.272-279, 1984.
DOI : 10.1115/1.3138493

S. Cruz-bustamante and A. , Contrôle par plaque séparatrice du proche sillage à l'aval d'un cylinder semi-circulaire, 2001.

M. Sato, K. Nagayama, N. Kataoka, M. Sasaki, and K. Hane, Local mechanical properties measured by atomic force microscopy for cultured bovine endothelial cells exposed to shear stress, Journal of Biomechanics, vol.33, issue.1, pp.127-162, 2000.
DOI : 10.1016/S0021-9290(99)00178-5

H. Schlichting, Boundary-layer theory, 1987.
DOI : 10.1007/978-3-662-52919-5

S. Schwartz, M. Reidy, O. Brien, and E. , Assessment of factors important in atherosclerotic occlusion and restenosis, Thromb Haemost, vol.74, pp.541-551, 1995.

D. Schwenke and T. Carew, Initiation of atherosclerotic lesions in cholesterol-fed rabbits. I. Focal increases in arterial LDL concentration precede development of fatty streak lesions, Arteriosclerosis, Thrombosis, and Vascular Biology, vol.9, issue.6, pp.895-907, 1989.
DOI : 10.1161/01.ATV.9.6.895

P. Serruys and M. Kutryk, Handbook of coronary stents, 2000.

M. Sharp, G. Thurston, J. Moore, and . Jr, The effect of blood viscoelasticity on pulsatile flow in stationary and axially moving tubes, Biorheology, vol.33, issue.3, pp.185-208, 1996.
DOI : 10.1016/0006-355X(96)00017-0

K. Shigematsu, H. Yasuhara, H. Shigematsu, and T. Muto, Direct and indirect effects of pulsatile shear stress on the smooth muscle cell, Int Angiol, vol.19, pp.39-46, 2000.

L. Simmers, Diversified Health Occupations, Thomson Delmar Learning, p.157, 2003.

H. Simon, H. Leo, J. Carberry, and A. Yoganathan, Investigation of the leakage flow fields of two bileaflet mechanical heart valves under aortic conditions. Proceeding of the European Society of Biomechanics, s-Hertogenbosch, 2004.

M. Siouffi, V. Deplano, and R. Pelissier, Experimental analysis of unsteady flows through a stenosis, Journal of Biomechanics, vol.31, issue.1, pp.11-19, 1998.
DOI : 10.1016/S0021-9290(97)00104-8

URL : https://hal.archives-ouvertes.fr/hal-00085339

F. Smith, The separating flow through a severely constricted symmetric tube, Journal of Fluid Mechanics, vol.227, issue.04, pp.725-754, 1979.
DOI : 10.1007/BF01535188

E. Sprague, J. Luo, and J. Palmaz, Human Aortic Endothelial Cell Migration onto Stent Surfaces under Static and Flow Conditions, Journal of Vascular and Interventional Radiology, vol.8, issue.1, pp.83-92, 1997.
DOI : 10.1016/S1051-0443(97)70521-9

E. Sprague, J. Palmaz, C. Simon, and A. Watson, Electrostatic forces on the surface of metals as measured by atomic force microscopy, J Long Term Eff Med Implants, vol.10, pp.111-125, 2000.

J. Squire, Dynamics of endovascular stent expansion. Thesis of Massachusetts institute of technology, 2000.

D. Steinberg and A. Gotto, Preventing Coronary Artery Disease by Lowering Cholesterol Levels, JAMA, vol.282, issue.21, pp.2043-2050, 1999.
DOI : 10.1001/jama.282.21.2043

D. Steinberg and A. Lewis, Oxidative Modification of LDL and Atherogenesis, Circulation, vol.95, pp.1062-1071, 1997.
DOI : 10.1007/978-94-011-5022-4_16

D. Steinberg, S. Parthasarathy, T. Carew, J. Khoo, and J. Witztum, Beyond cholesterol. Modification of low-density lipoprotein that increase atherogenicity, N. Engl. J. Med, vol.320, pp.915-924, 1989.

A. Sterpetti, A. Cucina, D. Angelo, L. Cardillo, B. Cavallaro et al., Shear stress modulates the proliferation rate, protein synthesis, and mitogenic activity of arterial smooth muscle cells, Surgery, vol.113, pp.691-699, 1993.

Y. Tardy, N. Resnick, T. Nagel, M. Gimbrone, . Jr et al., Shear Stress Gradients Remodel Endothelial Monolayers in Vitro via a Cell Proliferation-Migration-Loss Cycle, Arteriosclerosis, Thrombosis, and Vascular Biology, vol.17, issue.11, pp.3102-3106, 1997.
DOI : 10.1161/01.ATV.17.11.3102

A. Texier and L. David, A KINEMATIC STUDY OF HYDRODYNAMIC FLOWS USING PARTICLE STREAK VELOCIMETRY TECHNIQUE, Journal of Flow Visualization and Image Processing, vol.3, issue.4, p.279298, 1996.
DOI : 10.1615/JFlowVisImageProc.v3.i4.40

S. Thangam and D. Knight, Effect of stepheight on the separated flow past a backward facing step, Physics of Fluids A: Fluid Dynamics, vol.1, issue.3, pp.604-606, 1989.
DOI : 10.1063/1.857430

M. Thiriet, G. Martin-borret, and F. Hecht, ??coulement rh??ofluidifiant dans un coude et une bifurcation plane sym??trique. Application ?? l'??coulement sanguin dans la grande circulation, Journal de Physique III, vol.6, issue.4, pp.529-542, 1996.
DOI : 10.1051/jp3:1996139

G. Thurston, Frequency and shear rate dependence of viscoelasticity of human blood, Biorheology, vol.10, pp.375-81, 1973.

G. Thurston, Rheological parameters for the viscosity viscoelasticity and thixotropy of blood, Biorheology, vol.16, pp.149-162, 1979.

M. Togni, F. Balmer, D. Pfiffner, W. Maier, A. Zeiher et al., Percutaneous coronary interventions in Europe 1992?2001, European Heart Journal, vol.25, issue.14, pp.1208-1213, 1992.
DOI : 10.1016/j.ehj.2004.04.024

A. Tortoriello and G. Pedrizzetti, Flow-tissue interaction with compliance mismatch in a model stented artery, Journal of Biomechanics, vol.37, issue.1, pp.1-11, 2004.
DOI : 10.1016/S0021-9290(03)00259-8

C. Tropea and R. Gackstatter, The Flow Over Two-Dimensional Surface-Mounted Obstacles at Low Reynolds Numbers, Journal of Fluids Engineering, vol.107, issue.4, pp.489-494, 1985.
DOI : 10.1115/1.3242518

H. Tsuboi, J. Ando, R. Korenaga, Y. Takada, and A. Kamiya, Flow Stimulates ICAM-1 Expression Time and Shear Stress Dependently in Cultured Human Endothelial Cells, Biochemical and Biophysical Research Communications, vol.206, issue.3, pp.988-996, 1995.
DOI : 10.1006/bbrc.1995.1140

C. Tu and M. Deville, Pulsatile flow of non-Newtonian fluids through arterial stenoses, Journal of Biomechanics, vol.29, issue.7, pp.899-908, 1996.
DOI : 10.1016/0021-9290(95)00151-4

. S. Uchida, The pulsating viscous flow superposed on the steady laminar motion of incompressible fluid in a circular pipe, Zeitschrift f??r angewandte Mathematik und Physik ZAMP, vol.42, issue.5, pp.403-421, 1956.
DOI : 10.1007/BF01606327

O. Uzol, Y. Chow, J. Katz, and C. Meneveau, Unobstructed PIV measurements within an axial turbo-pump using liquid and blades with matched refractive indices, Proceeding of 4th International Symposium on Particle Image Velocimetry, pp.17-19, 2001.
DOI : 10.1007/s00348-002-0494-8

H. Vernhet, R. Demaria, J. Juan, M. Oliva-lauraire, J. Senac et al., Changes in Wall Mechanics After Endovascular Stenting in the Rabbit Aorta, American Journal of Roentgenology, vol.176, issue.3, pp.803-807, 2001.
DOI : 10.2214/ajr.176.3.1760803

H. Versteeg and W. Malalasekera, An introduction to computational fluid dynamics, the finite volume method, 1995.

R. Virmani, F. Kolodgie, A. Farb, and A. Lafont, Drug eluting stents: are human and animal studies comparable?, Heart, vol.89, issue.2, pp.133-138, 2003.
DOI : 10.1136/heart.89.2.133

URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1767527

V. Dahl, J. Dietz, U. Silber, and S. , Rotational Atherectomy Does Not Reduce Recurrent In-Stent Restenosis: Results of the Angioplasty Versus Rotational Atherectomy for Treatment of Diffuse In-Stent Restenosis Trial (ARTIST), Circulation, vol.105, issue.5, pp.583-588, 2002.
DOI : 10.1161/hc0502.103347

M. Walsh, T. Mcgloughlin, D. Liepsch, O. Brien, T. Morris et al., On using experimentally estimated wall shear stresses to validate numerically predicted results, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol.6, issue.5, pp.77-90, 2003.
DOI : 10.1243/09544110360579286

B. Wang, X. Liu, D. Dumas, J. Stoltz, and X. Wang, The migration of endothelial cells under laminar shear stress, 2003.

J. Westerweel, Efficient detection of spurious vectors in particle image velocimetry data, Experiments in Fluids, vol.16, issue.3-4, pp.236-247, 1994.
DOI : 10.1007/BF00206543

J. Westerweel, Fundamentals of digital particle image velocimetry, Measurement Science and Technology, vol.8, issue.12, pp.1379-1392, 1997.
DOI : 10.1088/0957-0233/8/12/002

C. White, M. Haidekker, X. Bao, and J. Frangos, Temporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation, Circulation, vol.103, issue.20, pp.2508-2513, 2001.
DOI : 10.1161/01.CIR.103.20.2508

E. Wilson, K. Sudhir, and H. Ives, Mechanical strain of rat vascular smooth muscle cells is sensed by specific extracellular matrix/integrin interactions., Journal of Clinical Investigation, vol.96, issue.5, pp.2364-2372, 1995.
DOI : 10.1172/JCI118293

M. Winter, K. Van-dijk, L. Havenekes, and M. Hofker, Macrophage Scavenger Receptor Class A : A Multifunctional Receptor in Atherosclerosis, Arteriosclerosis, Thrombosis, and Vascular Biology, vol.20, issue.2, pp.290-297, 2000.
DOI : 10.1161/01.ATV.20.2.290

J. Womersley, Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known, The Journal of Physiology, vol.127, issue.3, pp.553-563, 1955.
DOI : 10.1113/jphysiol.1955.sp005276

W. Bank, World development report 1993: investing in health, 1993.

C. Zarins, M. Zatina, D. Giddens, D. Ku, and S. Glagov, Shear stress regulation of artery lumen diameter in experimental atherogenesis, Journal of Vascular Surgery, vol.5, issue.3, pp.413-420, 1987.
DOI : 10.1016/0741-5214(87)90048-6

J. Zhang and Z. Kuang, Study on blood constitutive parameters in different blood constitutive equations, Journal of Biomechanics, vol.33, issue.3, pp.355-360, 2000.
DOI : 10.1016/S0021-9290(99)00101-3

H. Zhu, J. Warner, T. Gehrig, and M. Friedman, Comparison of coronary artery dynamics pre- and post-stenting, Journal of Biomechanics, vol.36, issue.5, pp.689-697, 2003.
DOI : 10.1016/S0021-9290(02)00447-5