R. E. Tjho-heslinga, J. Davelaar, H. M. Kemme, H. De-vroome, J. A. Oosterhuis et al., Results of ruthenium irradiation of uveal melanomas: the Dutch experience, Radiotherapy and Oncology, vol.53, issue.2, pp.133-137, 1999.
DOI : 10.1016/S0167-8140(99)00105-X

P. Lommatzsch, Treatment of choroidal melanoma with 106 Ru/ 106 Rh beta ray applicators, Surv. Ophtalmo, vol.19, issue.2, pp.85-100, 1974.

P. Lommatzsch, Results after beta-irradiation (106Ru/106Rh) of choroidal melanomas: 20 years' experience., British Journal of Ophthalmology, vol.70, issue.11, pp.844-851, 1986.
DOI : 10.1136/bjo.70.11.844

P. Lommatzsch, B. Weise, and R. Ballin, Rh), Klinische Monatsbl??tter f??r Augenheilkunde, vol.189, issue.08, pp.133-140, 1986.
DOI : 10.1055/s-2008-1050770

P. Lommatzsch and I. Kirsch, 106Ru/106Rh plaque radiotherapy for malignant melanomas of the choroid, Documenta Ophthalmologica, vol.99, issue.3-4, pp.225-238, 1988.
DOI : 10.1007/BF00156429

J. Davelaar, D. Schaling, L. Hennen, and J. Broerse, Dosimetry of ruthenium-106 eye applicators, Medical Physics, vol.19, issue.3, pp.691-694, 1992.
DOI : 10.1118/1.596898

J. Grange, G. Joshi, J. Gérard, B. Jean-louis, I. Senténac et al., Bilan de dix années d'expériences de la béta-curiethérapie de contact par applicateur de ruthénium 106, pour mélanome de l'uvée. Revus de 207 cas et hommage à Lommatzsch, Ophtalmologie, vol.9, pp.317-323, 1995.

M. Kleineidam, R. Guthoff, and S. Bentzen, Rates of local control, metastasis, and overall survival in patients with posterior uveal melanomas treated with ruthenium-106 plaques, Radiotherapy and Oncology, vol.28, issue.2, pp.148-156, 1993.
DOI : 10.1016/0167-8140(93)90007-U

S. Seregard, E. Trampe, I. Lax, E. Kock, and G. Lundell, Results following episcleral ruthenium plaque radiotherapy for posterior uveal melanoma The Swedish experience, Acta Ophthalmologica Scandinavica, vol.29, issue.1, pp.11-16, 1997.
DOI : 10.1111/j.1600-0420.1997.tb00241.x

P. Summanem, I. Immonem, J. Heikkonen, P. Tommila, L. Laatikainen et al., Survival of patients and metastatic and local recurrent tumour growth in malignant melanoma of the uvea after ruthenium plaque radiotherapy, Ophthal. Surg, vol.25, pp.82-90, 1993.

P. Summanem, I. Immonem, T. Kivelä, P. Tommila, J. Heikkonen et al., Visual outcome of eyes with malignant melanoma of the uvea after ruthenium plaque radiotherapy, Ophthal. Surg. Lasers, vol.26, pp.449-460, 1995.

P. Summanem, I. Immonem, T. Kivelä, P. Tommila, J. Heikkonen et al., Radiation related complications after ruthenium plaque radiotherapy of uveal melanoma., British Journal of Ophthalmology, vol.80, issue.8, pp.732-739, 1996.
DOI : 10.1136/bjo.80.8.732

R. Müller, H. Buss, R. Pötter, P. Kroll, and U. Haverkamp, Results of high dose 106-ruthenium irradiation of choroidal melanomas, International Journal of Radiation Oncology*Biology*Physics, vol.12, issue.10, pp.1749-1755, 1986.
DOI : 10.1016/0360-3016(86)90315-9

R. Pötter, K. Janssen, and F. Prott, Ruthenium-106 Eye Plaque Brachytherapy in the Conservative Treatment of Uveal Melanoma: Evaluation of 175 Patients Treated with 150 Gy from 1981???1989, Radiotherapy of ocular disease, pp.143-149, 1997.
DOI : 10.1159/000425697

B. Polak and R. Wijngaarde, Radiation retinopathy in patients with both diabetes mellitus and ophthalmic Graves' disease, Orbit, vol.102, issue.2, pp.71-74, 1995.
DOI : 10.1136/bjo.64.9.660

M. Viebahn, M. Barricks, and M. Osterloh, Synergism between diabetic and radiation retinopathy: case report and review., British Journal of Ophthalmology, vol.75, issue.10, pp.629-632, 1991.
DOI : 10.1136/bjo.75.10.629

S. Supe, M. Rao, S. Sawant, and S. , ?? RAY EYE APPLICATORS, American Journal of Roentgenology, vol.123, issue.1, pp.36-41, 1975.
DOI : 10.2214/ajr.123.1.36

F. Bacin, S. Amara, J. L. Kemeny, R. Rozan, J. J. Bard et al., Etude comparative de l???irradiation b??ta (<sup>106</sup>Ru/<sup>106</sup>Rh) et de l???irradiation gamma (<sup>125</sup>I) sur l?????il du lapin, Ophthalmologica, vol.212, issue.6, pp.429-438, 1998.
DOI : 10.1159/000027382

S. Nag, J. M. Quivey, J. D. Earle, D. Followill, J. Fontanesi et al., The American Brachytherapy Society recommendations for brachytherapy of uveal melanomas, International Journal of Radiation Oncology*Biology*Physics, vol.56, issue.2, pp.544-555, 2003.
DOI : 10.1016/S0360-3016(03)00006-3

P. T. Finger, Tumour location affects the incidence of cataract and retinopathy after ophthalmic plaque radiation therapy, British Journal of Ophthalmology, vol.84, issue.9, pp.1068-1070, 2000.
DOI : 10.1136/bjo.84.9.1068

J. S. Pruit, C. G. Soares, and M. Ehrlich, Calibration of beta-particle radiation instrumentation and sources, NBS Special publication, pp.250-271, 1988.
DOI : 10.6028/NBS.SP.250-21

M. Piessens and N. Reynaert, Verification of absolute dose rates for intravascular brachytherapy beta sources, Physics in Medicine and Biology, vol.45, issue.8, pp.2219-2231, 2000.
DOI : 10.1088/0031-9155/45/8/311

A. Niroomand-rad, C. R. Blackwell, B. M. Coursey, K. P. Gall, J. M. Galvin et al., Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55, Medical Physics, vol.41, issue.11, pp.2093-2115, 1998.
DOI : 10.1118/1.598407

J. A. Sayeg and R. C. Gregory, A new method for characterizing beta-ray ophthalmic applicator sources, Medical Physics, vol.18, issue.3, pp.453-461, 1991.
DOI : 10.1118/1.596693

C. G. Soares, Y ophthalmic applicators, Physics in Medicine and Biology, vol.37, issue.4, pp.1005-1007, 1992.
DOI : 10.1088/0031-9155/37/4/014

C. G. Soares, D. G. Halpern, and C. K. Wang, Calibration and characterization of beta-particle sources for intravascular brachytherapy, Medical Physics, vol.28, issue.3, pp.339-346, 1998.
DOI : 10.1118/1.598204

C. G. Soares, S. Vynckier, H. Jarvinen, W. G. Cross, P. Sipila et al., Dosimetry of beta-ray ophthalmic applicators: Comparison of different measurement methods, Medical Physics, vol.39, issue.7, pp.1373-1384, 2001.
DOI : 10.1118/1.1376441

C. S. Reft, F. T. Kuchnir, I. Rosenberg, and L. C. Myrianthopoulos, Dosimetry of Sr-90 ophthalmic applicators, Dosimetry of Sr-90 ophthalmic applicators, pp.641-646, 1990.
DOI : 10.1118/1.596494

D. R. Schaart, A. J. Bos, A. J. Winkelman, and M. C. Clarijs, Re ?? line source measured with novel, ultra-thin TLDs in a PMMA phantom: comparison with Monte Carlo simulations, Physics in Medicine and Biology, vol.47, issue.20, pp.3605-3627, 2002.
DOI : 10.1088/0031-9155/47/20/304

L. Missotten, W. Dirven, A. Van-der-schueren, A. Leys, G. De-meester et al., Results of treatment of choroidal malignant melanoma with high-dose-rate strontium-90 brachytherapy, Graefe's Archive for Clinical and Experimental Ophthalmology, vol.236, issue.3, pp.164-173, 1983.
DOI : 10.1007/s004170050059

W. Binder, A. Chiari, and H. Aiginger, Determination of the Dose Distribution of an Ophthalmic 106Ru Irradiator with TLDs and an Eye Phantom, Radiation Protection Dosimetry, vol.34, issue.1-4, pp.275-278, 1990.
DOI : 10.1093/oxfordjournals.rpd.a080901

D. Siddle and K. Langmack, Calibration of strontium-90 eye applicator using a strontium external beam standard, Physics in Medicine and Biology, vol.44, issue.7, pp.1597-1608, 1999.
DOI : 10.1088/0031-9155/44/7/302

B. Schaeken and P. Scalliet, One year of experience with alanine dosimetry in radiotherapy, Applied Radiation and Isotopes, vol.47, issue.11-12, pp.1177-1182, 1996.
DOI : 10.1016/S0969-8043(96)00040-1

D. Flüs, M. Heintz, F. Indenkämpen, C. Wieczorek, H. Kolanski et al., Direct reading measurement of absorbed dose with plastic scintillators-The general concept and applications to ophthalmic plaque dosimetry, Medical Physics, vol.23, issue.3, pp.427-434, 1996.
DOI : 10.1118/1.597736

M. Heydarian, P. W. Hoban, W. A. Beckham, I. M. Borchardt, and A. H. Beddoe, Evaluation of a PTW diamond detector for electron beam measurements, Physics in Medicine and Biology, vol.38, issue.8, pp.1035-1042, 1993.
DOI : 10.1088/0031-9155/38/8/002

S. Vatnitsky and H. Jarvinen, Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy, Physics in Medicine and Biology, vol.38, issue.1, pp.173-184, 1993.
DOI : 10.1088/0031-9155/38/1/013

G. Rikner and E. Grusell, General specifications for silicon semiconductors for use in radiation dosimetry, Physics in Medicine and Biology, vol.32, issue.9, pp.1109-1117, 1987.
DOI : 10.1088/0031-9155/32/9/004

I. Lax, Ru eye applicators with a p-type silicon detector, Physics in Medicine and Biology, vol.36, issue.7, pp.963-972, 1991.
DOI : 10.1088/0031-9155/36/7/005

M. F. Chan, A. Y. Fung, Y. C. Hu, C. S. Chui, H. Amols et al., The measurement of three dimensional dose distribution of a ruthenium-106 ophthalmological applicator using magnetic resonance imaging of BANG polymer gels, J.Appl.Clin.Med.Phys, vol.2, pp.85-89, 2001.

M. J. Maryanski, G. S. Ibbott, P. Eastman, R. J. Schulz, and J. C. Gore, Radiation therapy dosimetry using magnetic resonance imaging of polymer gels, Medical Physics, vol.23, issue.5, pp.699-705, 1996.
DOI : 10.1118/1.597717

S. L. Meeks, F. J. Bova, M. J. Maryanski, L. A. Kendrick, M. K. Ranade et al., Image registration of BANG?? gel dose maps for quantitative dosimetry verification, International Journal of Radiation Oncology*Biology*Physics, vol.43, issue.5, pp.1135-1141, 1999.
DOI : 10.1016/S0360-3016(98)00536-7

R. P. Kollaard, W. J. Dries, H. J. Van-kleffens, A. H. Aalbers, J. Van-der-marel et al., Report 14 of the Netherlands Commission on Radiation Dosimetry Quality control of sealed beta sources in brachytherapy, Recommendations on detectors, measurement procedures and quality control of beta sources, 2004.

S. Trichter, Treatment Planning for Ru-106 Eye Plaques, Pitfalls and Remedies, Poster at RSNA 2002 -88th Scientific Assembly and Annual Meeting

M. Astrahan, G. Luxton, G. Jozsef, T. D. Kampp, P. Liggett et al., An interactive treatment planning system for ophthalmic plaque radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.18, issue.3, pp.679-687, 1990.
DOI : 10.1016/0360-3016(90)90077-W

M. Astrahan, G. Luxton, G. Joszef, P. Liggett, and Z. Petrovich, I ophthalmic plaque brachytherapy, Medical Physics, vol.17, issue.6, pp.1053-1057, 1990.
DOI : 10.1118/1.596585

M. D. Evans, M. A. Astrahan, and R. Bate, Tumor localization using fundus view photography for episcleral plaque therapy, Medical Physics, vol.20, issue.3, pp.1053-1057, 1990.
DOI : 10.1118/1.597031

M. A. Astrahan, A patch source model for treatment planning of ruthenium ophthalmic applicators, Medical Physics, vol.69, issue.6, pp.1219-1228, 2003.
DOI : 10.1118/1.1573971

M. J. Rivard, B. M. Coursey, L. A. Dewerd, W. F. Hanson, M. S. Huq et al., Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations, Med. Phys, issue.3, pp.31-633, 2004.

W. G. Cross, J. Hokkanen, H. Järvinen, F. Mourtada, P. Sipilä et al., Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye, Medical Physics, vol.14, issue.7, pp.1385-1396, 2001.
DOI : 10.1118/1.1376442

I. Foster and C. Kesselman, Globus: a Metacomputing Infrastructure Toolkit, International Journal of High Performance Computing Applications, vol.11, issue.2, pp.115-128, 1997.
DOI : 10.1177/109434209701100205

I. Foster, C. Kesselman, G. Tsudik, and S. Tuecke, A security architecture for computational grids, Proceedings of the 5th ACM conference on Computer and communications security , CCS '98, pp.83-92, 1998.
DOI : 10.1145/288090.288111

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.25.9598

E. Medernach, Workload Analysis of a cluster in a Grid Environment, OICMS proceedings, 2005.

D. Zotkin and P. J. Keleher, Job-length estimation and performance in backfilling schedulers, Proceedings. The Eighth International Symposium on High Performance Distributed Computing (Cat. No.99TH8469), 1999.
DOI : 10.1109/HPDC.1999.805303

V. Breton, K. Dean, and T. Solomonides, The HealthGrid White Paper. From Grid to HealthGrid, 2005.
URL : https://hal.archives-ouvertes.fr/in2p3-00024024

. Healthgrid, HealthGrid Association, 2003.

H. K. Huang, PACS: Picture Archiving and Communication Systems in Biomedical Imaging, 1996.

L. Seitz, J. Pierson, and L. Brunie, Key Management for Encrypted Data Storage in Distributed Systems, Second IEEE International Security in Storage Workshop, 2003.
DOI : 10.1109/SISW.2003.10001

L. Seitz, J. Pierson, and L. Brunie, Semantic Access Control for Medical Applications in Grid Environments, Euro-Par 2003 Parallel Processing, volume LNCS 2790, pp.374-383, 2003.
DOI : 10.1007/978-3-540-45209-6_56

URL : https://hal.archives-ouvertes.fr/hal-01514890

B. Allcock, J. Bester, J. Bresnahan, A. Chervenak, I. Foster et al., Data management and transfer in high-performance computational grid environments, Parallel Computing, vol.28, issue.5, pp.749-771, 2002.
DOI : 10.1016/S0167-8191(02)00094-7

B. Claerhout, D. Moor, and G. , Privacy protection for healthgrid applications, 2004.

J. Montagnat, F. Bellet, H. Benoit-cattin, V. Breton, L. Brunie et al., Medical Images Simulation, Storage, and Processing on the European DataGrid Testbed, Journal of Grid Computing, 2004.
DOI : 10.1007/s10723-004-5744-y

URL : https://hal.archives-ouvertes.fr/in2p3-00023294

S. Jan and C. Morel, GATE: a simulation toolkit for PET and SPECT, Physics in Medicine and Biology, vol.49, issue.19, pp.4543-4561, 2004.
DOI : 10.1088/0031-9155/49/19/007

URL : https://hal.archives-ouvertes.fr/in2p3-00021834

J. De-beenhouwer, S. Staelens, M. Dressel, Y. D-'asseler, S. Vandenberghe et al., Geometrical importance sampling and pulse height tallies in GATE, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2004.
DOI : 10.1109/IEMBS.2004.1403422

H. Jiang and H. Paganetti, to Monte Carlo dose calculations based on CT data, Medical Physics, vol.41, issue.10, pp.2811-2818, 2004.
DOI : 10.1118/1.1796952

D. Cullen, J. H. Hubbell, and L. , The Evaluated Photon Data Library

S. T. Perkins, D. E. Cullen, and S. M. , Seltzer Tables and Graphs of Electron-Interaction Cross- Sections from 10 eV to 100 GeV Derived from the LLNL Evaluated Electron Data Library, pp.1-100

S. T. Perkins, D. E. Cullen, M. H. Chen, J. H. Hubbell, J. Rathkopf et al., Tables and Graphs of Atomic Subshell and Relaxation Data Derived from the LLNL Evaluated Atomic Data Library, pp.1-100

J. Sempau, J. M. Fern´andez-vare-a, E. Acosta, and F. Salvat, Experimental benchmarks of the Monte Carlo code penelope, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.207, issue.2, pp.107-123, 2003.
DOI : 10.1016/S0168-583X(03)00453-1

J. F. Ziegler-mascialino, S. Parlati, M. G. Pia, and A. , Helium: Stopping Powers and Ranges in all of The Stopping and Ranges of Ions in MatterEvaluated Nuclear Structure Data File, Geant4 Collaboration, pp.250-303, 1977.

A. Pfeiffer, P. J. Ribon, I. Williamson, D. J. Washington, T. R. Simpkin et al., Monte Carlo evaluation of kerma at a point for photon transport problems Dosimetry of External Beta Rays for Radiation Protection Beta-ray dose distributions from point sources in an infinite water medium EGS4 Monte Carlo determination of the beta dose kernel in water [26 ] http://www.irs.inms.nrc.ca/inms Stopping powers and ranges of electrons and positrons electron stopping powers for transport claculations Monte Carlo transport of electrons and photons ETRAN-experimental benchmarks Monte Carlo transport of electrons and photons Monte Carlo transport of electrons and photons Bremsstrahlung spectra from electron interactions with screened atomic nuclei and orbital electrons Bremsstrahlung energy spectra from electrons with kinetic energy 1 keV-10 GeV incident on screened nuclei and orbital electrons of neutral atoms with Z=1- 100 Cross sections for bremsstrahlung production and electron impact ionization An overview of ETRAN Monte Carlo methods, Monte Carlo transport of electrons and photons In: T.M. jenkins, W.R Monte Carlo transport of electrons and photons, pp.2056-2063, 1985.

O. Blunck and S. Liesegang, Zum Energieverlust schneller Elektronen in d???nnen Schichten, Zeitschrift f???r Physik, vol.128, issue.4, pp.500-505, 1950.
DOI : 10.1007/BF01330032

J. A. Halbleib, Structure and operation of the ITS code system Monte Carlo transport of electrons and photons, pp.249-262, 1988.

J. A. Halbleib, Applications of the ITS Codes
DOI : 10.1007/978-1-4613-1059-4_11

D. W. Rogers and A. F. Bielajew, Fluence to dose equivalent conversion factors calculated with EGS3 for electrons from 100 keV to 20 GeV and photons from 11 keV to 20 GeV. Health Phys Differences in electron depth dose curves calculated with EGS and ETRAN and improved energy range relationships Presta: the parameter reduced electron-step transport algorithm for electron Monte Carlo transport, Monte Carlo transport of electrons and photons, pp.263-286891, 1984.

]. R. References1, E. M. Loevinger, G. L. Japha, G. L. Brownell, G. L. Hine et al., Medical Radionuclides: Radiation dose and effects (AEC Symposium Series N°20) Oak Ridge Conf Dosimetry of beta sources in radiotherapy I. The beta point source dose function Theoretical calculations of dose distributions for beta-ray eye applicators Dosimetry of beta-ray ophthalmic applicators: Comparison of different measurement methods Update of AAPM Task Group No.43 Report: A revised AAPM protocol for brachytherapy dose calculations Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye The determination of dose characteristics of ruthenium ophthalmic applicators using radiochromic film Dosimetry of ruthenium-106 eye applicators Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions Measurement of effective atomic number and electron density using an EMI scanner Average soft tissue and bone models for use in radiation dosimetry The composition of body tissues The Physics of Radiology The calibration of CT Hounsfield units for radiotherapy treatment planning, Phys. Med. Biol Can. J. Phys. Phys. Med. Biol. Med. Phys. Med. Phys. Med. Phys. Med. Phys. Med. Phys. Med. Phys. Phys. Med. Biol. Neuroradiology Br.J.Radiol. Br. J.Radiol. Phys. Med. Biol, vol.1827121415, issue.41, pp.1339-1347, 1956.

J. E. Gentle, Random Number Generation and Monte Carlo Methods in 2 nd Edition, Statistics & Computing collec, p.381, 2003.

M. Traore and D. Hill, The use of random number generation for stochastic distributed simulation: application to ecological modeling " . 13 th European Simulation Symposium, pp.555-559, 2001.

P. Coddington, Random Number Generators For Parallel Computers, NHSE Review, 1996.

P. Hellekalek, Don't trust parallel Monte Carlo!, Proceedings of the 12th Workshop on PADS, pp.82-89, 1998.

A. Srinivasan, D. Ceperley, and M. Mascagni, Testing parallel random number generators [www http://www.ncsa.uiuc, p.3, 1998.

O. E. Percus and M. H. Kalos, Random number generators for MIMD parallel processors, Journal of Parallel and Distributed Computing, vol.6, issue.3, pp.477-497, 1989.
DOI : 10.1016/0743-7315(89)90002-6

. M. Mascagni, S. A. Cuccaro, and D. V. Pryor, Techniques for Testing the Quality of Parallel Pseudorandom Number Generators, Proceedings of the 7 th SIAM Conference on Parallel Processing for Scientific Computing, pp.279-284, 1995.

O. Publications, P. L. Work, D. Maigne, P. Hill, V. Calvat et al., Parallelization of Monte Carlo Simulations and Submission to a Grid Environment, Parallel Processing Letters journal, vol.14, issue.2, pp.177-196, 2004.

J. Pennacchio, U. Perez, F. R. Pietrzyk, M. Rannou, D. R. Rey et al., GATE: a simulation toolkit for PET and SPECT, Phys. Med. Biol, pp.49-4543, 2004.
URL : https://hal.archives-ouvertes.fr/in2p3-00021834

S. Spanoudaki, S. Styliaris, V. Staelens, and . Breton, Monte Carlo simulation of a CsI(Tl) gamma camera dedicated to small animal imaging using GATE, Phys. Med. Biol, vol.49, pp.271-285, 2004.

V. Breton, C. Blanchet, Y. Legré, L. Maigne, and &. J. Montagnat, Grid Technology for Biomedical Applications, Proceedings of High Performance Computing for Computational Science, VECPAR 2004 conference, pp.204-218, 2005.
DOI : 10.1007/11403937_17

URL : https://hal.archives-ouvertes.fr/in2p3-00171787

C. L. Maigne, D. Donnarieix, V. Breton, and Y. Legré, Use of a calculation grid to run Monte Carlo simulation programs with the Geant4 Software in ocular brachytherapy, Physica Medica, vol.3, 2003.

L. Berger, V. Breton, D. Donnarieix, D. Lazaro, and L. Maigne, Computation of P1 problem using the Monte Carlo code GATE " in Intercomparison on the usage of computational codes in radiation dosimetry, QUADOS Conference proceedings G. Gualdrini and P. Ferrari Editors, 2004.

D. Visvikis, M. Bardiès, S. Chiavassa, C. Danford, A. Kirov et al., Use of the GATE Monte Carlo package for dosimetry applications, ITBS 2005 conference
DOI : 10.1016/j.nima.2006.08.049

URL : https://hal.archives-ouvertes.fr/in2p3-00025095

I. Buvat and . Lemahieu, GATE, ITBS 2005 conference
DOI : 10.1201/b13073-9

URL : https://hal.archives-ouvertes.fr/in2p3-00025096