S. Bonnet, A. Koenig, S. Roux, P. Hugonnard, R. Guillemaud et al., Dynamic X-ray computed tomography, Proceedings of the IEEE, pp.1574-87, 2003.
DOI : 10.1109/JPROC.2003.817868

L. Desbat, S. Roux, P. Grangeat, and A. Koenig, Efficient sampling in dynamic tomography, Fifth International Conference on Curves and Surfaces, 2002.

L. Desbat, S. Roux, P. Grangeat, and A. Koenig, Sampling conditions of 3D fan beam X ray transform, Fully 3D Reconstruction in Radiology and Nuclear Medicine, Saint Malo, 2003.

L. Desbat, S. Roux, P. Grangeat, and A. Koenig, Sampling conditions of 3D parallel and fan-beam x-ray CT with application to helical tomography, Physics in Medicine and Biology, vol.49, issue.11, pp.2377-90, 2004.
DOI : 10.1088/0031-9155/49/11/018

URL : https://hal.archives-ouvertes.fr/hal-00308440

S. Roux, L. Desbat, A. Koenig, and P. Grangeat, Efficient acquisition protocol for cardiac dynamic CT, 2002 IEEE Nuclear Science Symposium Conference Record, 2002.
DOI : 10.1109/NSSMIC.2002.1239631

S. Roux, L. Desbat, A. Koenig, and P. Grangeat, Efficient acquisition for periodic dynamic ct, IEEE Transactions on Nuclear Science, vol.50, issue.5, pp.1672-77, 2003.
DOI : 10.1109/TNS.2003.817957

S. Roux, L. Desbat, A. Koenig, and P. Grangeat, Exact fan-beam compensated reconstruction formula for time-dependent affine deformations, Fully 3D Reconstruction in Radiology and Nuclear Medicine, Saint Malo, 2003.

S. Roux, L. Desbat, A. Koenig, and P. Grangeat, Exact reconstruction in 2D dynamic CT: compensation of time-dependent affine deformations, Physics in Medicine and Biology, vol.49, issue.11, pp.2169-82, 2004.
DOI : 10.1088/0031-9155/49/11/004

URL : https://hal.archives-ouvertes.fr/hal-00308419

S. Roux, L. Desbat, A. Koenig, and P. Grangeat, Méthodes analytiques de compensation des déformations en tomographie dynamique, Congrès national d'analyse numérique (CANUM), Obernai, 2004.

S. Roux, A. Koenig, L. Desbat, and P. Grangeat, Procédé de reconstruction d'une image tomographique par une méthode analytique comprenant une modélisation améliorée du mouvement de l'objet, 2003.

. Bibliographie-en-tomographie-statique-]-h, F. Benali, and . Peyrin, Chapitre 4 : Les méthodes discrètes, pp.111-150, 2002.

G. H. Chen, A new framework of image reconstruction from fan beam projections, Medical Physics, vol.47, issue.6, pp.1151-1161, 2003.
DOI : 10.1118/1.1577252

C. R. Crawford and K. F. King, Computed tomography scanning with simultaneous patient translation, Medical Physics, vol.17, issue.6, pp.967-82, 1990.
DOI : 10.1118/1.596464

P. E. Danielsson, P. Edholm, and M. Seger, Towards exact 3d-reconstruction for helical cone-beam scanning of longs objects. a new detector arrangement and a new completeness condition, Fully 3D Reconstruction in Radiology and Nuclear Medicine, 1997.

S. R. Deans, The Radon transform and some of its applications, 1983.

M. Defrise and R. Clack, A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection, IEEE Transactions on Medical Imaging, vol.13, issue.1, pp.186-195, 1994.
DOI : 10.1109/42.276157

M. Defrise, F. Noo, and H. Kudo, Rebinning-based algorithms for helical cone-beam CT, Physics in Medicine and Biology, vol.46, issue.11, pp.2911-2948, 2001.
DOI : 10.1088/0031-9155/46/11/311

L. Desbat, Échantillonnage efficace en tomographie, 1997.
DOI : 10.1016/s0764-4442(97)87910-4

L. Desbat, ??chantillonnage parall??le efficace en tomographie 3D, Comptes Rendus de l'Acad??mie des Sciences - Series I - Mathematics, vol.324, issue.10, pp.1193-1199, 1997.
DOI : 10.1016/S0764-4442(97)87910-4

L. Desbat and C. Menessier, Chapitre 3 : Conditions d'échantillonnage en tomographie, pp.87-110, 2002.

L. A. Feldkamp, L. C. Davis, and J. W. Kress, Pratical cone-beam algorithm, pp.612-619, 1984.

A. L. Goertzen, F. J. Beekman, and S. R. Chery, Effect of phantom voxelization in CT simulations, Medical Physics, vol.3, issue.4, pp.492-98, 2002.
DOI : 10.1118/1.1461841

P. Grangeat, Analyse d'un sytème d'imagerie 3D par reconstructions à partir de radiographies X en géométrie conique, Thèse de doctorat, École Nationale Supérieure des Télécommunications, 1987.

P. Grangeat, Mathematical framework of cone beam 3D reconstruction via the first derivative of the radon transform, Lecture Notes in Mathematics, pp.66-97, 1991.
DOI : 10.1007/BFb0084509

P. Grangeat, P. Sire, R. Guillemaud, and V. La, Chapter 2 : Indirect cone-beam threedimensional image reconstruction, pp.39-52, 1997.

C. Hamaker, K. T. Smith, D. C. Solmon, and S. Wagner, The divergent beam x-ray transform, Rocky Mountain Journal of Mathematics, vol.10, issue.1, pp.253-283, 1980.
DOI : 10.1216/RMJ-1980-10-1-253

D. Heuscher, K. Brown, and F. Noo, Redundant data and exact helical cone-beam reconstruction, Physics in Medicine and Biology, vol.49, issue.11, pp.2219-2257, 2004.
DOI : 10.1088/0031-9155/49/11/008

J. Hsieh, Computed Tomography. Principles, design, artifacts and recent advances, 2003.
DOI : 10.1117/3.2197756

P. M. Joseph, An Improved Algorithm for Reprojecting Rays through Pixel Images, IEEE Transactions on Medical Imaging, vol.1, issue.3, pp.192-196, 1982.
DOI : 10.1109/TMI.1982.4307572

M. Kachelriess, S. Schaller, and W. Kalender, Advanced single-slice rebinning in cone-beam spiral CT, Medical Physics, vol.213, issue.P, pp.754-72, 2000.
DOI : 10.1118/1.598938

A. C. Kak and M. Slaney, Principles of Computerized Tomography Imaging, 1987.

A. Katsevich, Analysis of an exact inversion algorithm for spiral cone-beam CT, Physics in Medicine and Biology, vol.47, issue.15, pp.2583-98, 2002.
DOI : 10.1088/0031-9155/47/15/302

A. Katsevich, Theoretically Exact Filtered Backprojection-Type Inversion Algorithm for Spiral CT, SIAM Journal on Applied Mathematics, vol.62, issue.6, pp.2012-2038, 2002.
DOI : 10.1137/S0036139901387186

A. Katsevich, A general scheme for contructing inversion algorithms for cone beam CT, International journal of Mathematics and Mathematical Sciences, vol.21, pp.1305-1321, 2003.

A. Katsevich, S. Basu, and J. Hsieh, Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography, Physics in Medicine and Biology, vol.49, issue.14, pp.3089-3103, 2004.
DOI : 10.1088/0031-9155/49/14/004

H. Kudo, F. Noo, M. Defrise, and R. Clackdoyle, New super-short-scan algorithms for fan-beam and cone-beam reconstruction, 2002 IEEE Nuclear Science Symposium Conference Record, 2002.
DOI : 10.1109/NSSMIC.2002.1239470

H. Kudo, T. Rodet, F. Noo, and M. Defrise, Exact and approximate algorithms for helical cone-beam CT, Physics in Medicine and Biology, vol.49, issue.13, pp.2913-2944, 2004.
DOI : 10.1088/0031-9155/49/13/011

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.178.1162

H. Kudo and T. Saito, Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits, IEEE Transactions on Medical Imaging, vol.13, issue.1, pp.196-211, 1994.
DOI : 10.1109/42.276158

T. Köhler, C. Bontus, K. Brown, D. Heuscher, M. Grass et al., Evaluation of helical cone-beam CT reconstruction algorithms, 2002 IEEE Nuclear Science Symposium Conference Record, 2002.
DOI : 10.1109/NSSMIC.2002.1239539

F. Natterer, The Mathematics of Computerized Tomography, 1986.

F. Noo, M. Defrise, R. Clackdoyle, and H. Kudo, Image reconstruction from fan-beam projections on less than a short scan, Physics in Medicine and Biology, vol.47, issue.14, pp.2525-2546, 2002.
DOI : 10.1088/0031-9155/47/14/311

F. Noo, J. Pack, and D. Heuscher, Exact helical reconstruction using native cone-beam geometries, Physics in Medicine and Biology, vol.48, issue.23, pp.3787-3818, 2003.
DOI : 10.1088/0031-9155/48/23/001

J. D. Pack, F. Noo, and H. Kudo, Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry, Physics in Medicine and Biology, vol.49, issue.11, pp.2317-2353, 2004.
DOI : 10.1088/0031-9155/49/11/014

D. L. Parker, Optimal short scan convolution reconstruction for fan beam CT, Medical Physics, vol.9, issue.2, pp.245-257, 1982.
DOI : 10.1118/1.595078

J. Radon, Uber die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten, Berichte Sächsische Akademie der Wissenschaften, pp.262-267, 1917.
DOI : 10.1090/psapm/027/692055

L. A. Shepp and B. F. Logan, The Fourier reconstruction of a head section, IEEE Transactions on Nuclear Science, vol.21, issue.3, pp.21-43, 1974.
DOI : 10.1109/TNS.1974.6499235

H. K. Tuy, An Inversion Formula for Cone-Beam Reconstruction, SIAM Journal on Applied Mathematics, vol.43, issue.3, pp.546-552, 1983.
DOI : 10.1137/0143035

C. Bibliographie-en-tomographie-dynamique, G. Blondel, R. Malandain, N. Vaillant, and . Ayache, 4D deformation field of coronary arteries from monoplane rotational X-ray angiography, Proc. Computer Assisted Radiology and Surgery, pp.1073-78, 2003.

C. Blondel, R. Vaillant, G. Malandain, and N. Ayache, 3D tomographic reconstruction of coronary arteries using a precomputed 4D motion field, Physics in Medicine and Biology, vol.49, issue.11, pp.2197-2208, 2004.
DOI : 10.1088/0031-9155/49/11/006

URL : https://hal.archives-ouvertes.fr/inria-00615958

S. Bonnet, A. Koenig, P. Hugonnard, and P. Grangeat, Time delay analysis in online 4-D CT, Fully 3D Reconstruction in Radiology and Nuclear Medicine, Saint Malo, 2003.

C. Bontus, R. Proksa, J. Timmer, T. Köhler, and M. Grass, Movement artifacts in helical CT cone-beam reconstruction, Fully 3D Reconstruction in Radiology and Nuclear Medicine, pp.199-202, 2001.

D. P. Boyd and M. J. Lipton, Cardiac computed tomography, Proceedings of the IEEE, vol.71, issue.3, pp.298-307, 1983.
DOI : 10.1109/PROC.1983.12588

J. Bronson, Cardiac imaging: big changes ahead, Imaging economics, pp.52-58, 2003.

H. Bruder, E. Maguet, K. Stierstorfer, and T. Flohr, Cardiac spiral imaging in computed tomography without ECG using complementary projections for motion detection, Medical Imaging 2003: Image Processing, pp.1798-1809, 2003.
DOI : 10.1117/12.480390

H. Bruder, S. Schaller, B. Ohnesorge, and T. Mertelmeier, <title>High-temporal-resolution volume heart imaging with multirow computed tomography</title>, Medical Imaging 1999: Image Processing, pp.420-432, 1999.
DOI : 10.1117/12.348597

H. Bruder, K. Stierstorfer, B. Ohnesorge, S. Schaller, and T. Flohr, Novel reconstruction scheme for cardiac volume imaging with MSCT providing cone correction, Medical Imaging 2002: Image Processing, 2002.
DOI : 10.1117/12.467228

C. R. Crawford, Motion artefact reduction in projection imaging, 1993.

C. R. Crawford and N. J. Pelc, Method for reduction motion induced artifacts in projection imaging, 1991.

C. R. Crawford and C. J. Ritchie, Localized motion artefact reduction in projection imaging, 1994.

C. R. Crawford, K. F. King, C. J. Ritchie, and J. D. Godwin, Respiratory compensation in projection imaging using a magnification and displacement model, IEEE Transactions on Medical Imaging, vol.15, issue.3, pp.327-332, 1996.
DOI : 10.1109/42.500141

J. De-murcia, Reconstruction d'images cardiaques en tomographie d'émission monophotonique à l'aide de modèles spatio-temporels, 1996.

T. Flohr and B. Ohnesorge, Heart Rate Adaptive Optimization of Spatial and Temporal Resolution for Electrocardiogram-Gated Multislice Spiral CT of the Heart, Journal of Computer Assisted Tomography, vol.25, issue.6, pp.907-923, 2001.
DOI : 10.1097/00004728-200111000-00014

E. C. Ford, G. S. Mageras, E. Yorke, and C. C. Ling, Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning, Medical Physics, vol.26, issue.1, pp.88-97, 2003.
DOI : 10.1118/1.1531177

D. R. Gilland, B. A. Mair, J. E. Bowsher, and R. J. Jaszczak, Simultaneous reconstruction and motion estimation for gated cardiac ECT, IEEE Transactions on Nuclear Science, vol.49, issue.5, pp.2344-2349, 2002.
DOI : 10.1109/TNS.2002.803820

P. Grangeat, A. Koenig, T. Rodet, and S. Bonnet, Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model, Physics in Medicine and Biology, vol.47, issue.15, pp.472611-2625, 2002.
DOI : 10.1088/0031-9155/47/15/304

M. Grass, R. Manzke, T. Nielsen, P. Koken, R. Proksa et al., Helical cardiac cone beam reconstruction using retrospective ECG gating, Physics in Medicine and Biology, vol.48, issue.18, pp.3069-3083, 2003.
DOI : 10.1088/0031-9155/48/18/308

J. Hsieh, Adaptative motion artifact suppression in CT, SPIE Conf. on Med. Im, pp.429-427, 1996.

J. Hsieh, Motion artifact reduction with predictive gating, SPIE Conf. on Med. Im., volume, 1996.

J. Hsieh, Analysis of the temporal response of computed tomography fluoroscopy, Medical Physics, vol.17, issue.5, pp.665-675, 1997.
DOI : 10.1118/1.597989

J. Hsieh, J. Mayo, K. Acharya, and T. Pan, Adaptative phase-coded reconstruction for cardiac CT, SPIE Conf. on Med. Im, pp.501-505, 2000.

M. Kachelriess, T. Fuchs, R. Lapp, D. Sennst, S. Schaller et al., Image to volume weighting generalized ASSR for arbitrary pitch 3D and phase-correlated 4D spiral cone-beam CT reconstruction, Fully 3D Reconstruction in Radiology and Nuclear Medicine, 2001.

M. Kachelriess and W. A. Kalender, Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart, Medical Physics, vol.204, issue.12, pp.2417-2431, 1998.
DOI : 10.1118/1.598453

M. Kachelriess, M. Knaup, and W. A. Kalender, Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral conebeam CT with arbitrary pitch, arbitrary cone-angle, and 100 % dose usage, Medical Physics, issue.6, pp.311623-311664, 2004.

M. Kachelriess, D. Sennst, W. Maxlmoser, and W. A. Kalender, Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart, Medical Physics, vol.37, issue.7, pp.1489-1503, 2002.
DOI : 10.1118/1.1487861

M. Kachelriess, S. Ulzeimer, and W. A. Kalender, Ecg-correlated imaging of the heart with subsecond multislice spiral CT, IEEE Transactions on Medical Imaging, vol.19, pp.888-901, 2000.

M. Kachelriess, S. Ulzeimer, and W. A. Kalender, ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart, Medical Physics, vol.339, issue.8, pp.1881-1902, 2000.
DOI : 10.1118/1.1286552

A. Koenig, S. Bonnet, P. Grangeat, U. Van-stevendaal, M. Grass et al., First results on motion compensated dynamic reconstruction for CT fluoroscopy, European Congress on Radiology, 2004.

A. Koenig, P. Grangeat, S. Bonnet, and P. Hugonnard, Dynamic reconstruction for radiotherapy planning, Proc. Computer Assisted Radiology and Surgery, pp.521-526, 2002.
DOI : 10.1007/978-3-642-56168-9_87

J. Li, R. J. Jaszczak, H. Wang, and R. E. Coleman, A filtered-backprojection algorithm for fan-beam SPECT which corrects for patient motion, Physics in Medicine and Biology, vol.40, issue.2, pp.283-294, 1995.
DOI : 10.1088/0031-9155/40/2/006

N. C. Linney and P. H. Gregson, Organ motion detection in CT images using opposite rays in fan-beam projection systems, IEEE Transactions on Medical Imaging, vol.20, issue.11, pp.1109-1122, 2001.
DOI : 10.1109/42.963814

W. Lu and T. R. Mackie, Tomographic motion detection and correction directly in sinogram space, Physics in Medicine and Biology, vol.47, issue.8, pp.1267-1284, 2002.
DOI : 10.1088/0031-9155/47/8/304

R. Manzke, M. Grass, T. Nielsen, G. Shechter, and D. Hawkes, Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction, Medical Physics, vol.4, issue.12, pp.3072-80, 2003.
DOI : 10.1118/1.1624756

B. Ohnesorge, C. Becker, T. Flohr, and M. F. Reiser, Multi-slice CT Cardiac Imaging, 2002.
DOI : 10.1007/978-3-662-05069-9

B. Ohnesorge, T. Flohr, C. Becker, A. F. Kopp, U. J. Schoepf et al., Cardiac Imaging by Means of Electrocardiographically Gated Multisection Spiral CT: Initial Experience, Radiology, vol.217, issue.2, pp.564-71, 2000.
DOI : 10.1148/radiology.217.2.r00nv30564

N. J. Pelc and G. H. Glover, Method for reducing image artifacts due to projection measurement inconsistencies, U.S Patent, vol.4, pp.580-219, 1986.

C. J. Ritchie, J. D. Godwin, C. R. Crawford, W. Stanford, H. Anno et al., Minimum scan speeds for suppression of motion artifacts in CT., Radiology, vol.185, issue.1, pp.37-42, 1992.
DOI : 10.1148/radiology.185.1.1523332

C. J. Ritchie, C. R. Crawford, J. D. Godwin, K. F. King-land-yongmin, and . Kim, Correction of computed tomography motion artifacts using pixel-specific back-projection, IEEE Transactions on Medical Imaging, vol.15, issue.3, pp.333-342, 1996.
DOI : 10.1109/42.500142

C. J. Ritchie, J. Hsieh, M. F. Gard, J. D. Godwin, Y. Kim et al., Predictive respiratory gating: a new method to reduce motion artifacts on CT scans., Radiology, vol.190, issue.3, pp.847-852, 1994.
DOI : 10.1148/radiology.190.3.8115638

E. L. Ritman, L. D. Harris, J. H. Kinsey, and R. A. Robb, Computed tomographic imaging of the heart : The dynamic spatial reconstructor, Radiologic Clinics of North America, vol.18, pp.547-556, 1980.

W. P. Segars, D. S. Lalush, and B. M. Tsui, A realistic spline-based dynamic heart phantom, IEEE Transactions on Nuclear Science, vol.46, issue.3, pp.503-509, 1999.
DOI : 10.1109/23.775570

G. Shechter, G. Naveh, A. Altman, R. Proksa, and M. Grass, Cardiac image reconstruction on a 16-slice CT scanner using a retrospectively ECG-gated, multi-cycle 3D backprojection algorithm, SPIE Conf. on Med. Im, pp.1820-1848, 2001.

K. Sourbelle and W. A. Kalender, Generalization of Feldkamp reconstruction for clinical spiral cone-beam CT, Fully 3D Reconstruction in Radiology and Nuclear Medicine, Saint Malo, 2003.

M. K. Stehling, R. Turner, and P. Mansfield, Echo-planar imaging: magnetic resonance imaging in a fraction of a second, Science, vol.254, issue.5028, pp.43-50, 1991.
DOI : 10.1126/science.1925560

K. Tagushi and H. Anno, High temporal resolution for multislice helical computed tomography, Medical Physics, vol.54, issue.5, pp.861-872, 2000.
DOI : 10.1118/1.598951

S. Ulzheimer, Cardiac Imaging with X-ray Computed Tomography : New Approaches to Image Acquisition and Quality Assurance, 2001.

G. Wang and M. W. Vannier, Preliminary study on helical CT algorithms for patient motion estimation and compensation, IEEE Transactions on Medical Imaging, vol.14, issue.2, pp.205-216, 1995.
DOI : 10.1109/42.387702

G. Wang, S. Zhao, and D. Heuscher, A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging, Medical Physics, vol.26, issue.8, pp.1807-1822, 2002.
DOI : 10.1118/1.1494989

M. Wernick, J. Infusino, and M. Milosevic, Fast spatio-temporal image reconstruction for dynamic PET, IEEE Transactions on Medical Imaging, vol.18, issue.3, pp.185-195, 1999.
DOI : 10.1109/42.764885

N. P. Willis and Y. Bresler, Optimal scan for time-varying tomography. I. Theoretical analysis and fundamental limitations, IEEE Transactions on Image Processing, vol.4, issue.5, pp.642-53, 1995.
DOI : 10.1109/83.382498

N. P. Willis and Y. Bresler, Optimal scan for time-varying tomography. II. Efficient design and experimental validation, IEEE Transactions on Image Processing, vol.4, issue.5, pp.654-66, 1995.
DOI : 10.1109/83.382499

D. Zerfowski, Motion artifact compensation in CT, SPIE Conf. on Med. Im, 1998.

C. Gasquet and P. Witomski, Analyse de Fourier et applications. Filtrage, calcul numérique et ondelettes, 2000.

A. C. Guyton and J. E. Hall, Textbook of medical physiology, 2000.

C. Tisseron, Géométries affine, projective et euclidienne, 1983.