I. Guide, Safety aspects -Guidelines for their inclusion in standards, International Organization for Standardization, 1999.

L. Adams, W. Krybus, D. Meyer-ebrecht, R. Rueger, J. M. Gilsbach et al., Computer-assisted surgery, IEEE Comp. Graphics Appl, pp.43-51, 1990.
DOI : 10.1109/38.55152

S. Aiono, J. M. Gilbert, B. Soin, P. A. Finlay, and A. Gordan, Controlled trial of the introduction of a robotic camera assistant (EndoAssist) for laparoscopic cholecystectomy, Surgical Endoscopy, vol.16, issue.9, pp.1267-1270, 2002.
DOI : 10.1007/s00464-001-9174-7

L. M. Auer, A. Radetzky, C. Wimmer, G. Kleinszig, H. Deligette et al., Visualisation for planning and simulation of minimally invasive procedures, Lecture Notes in Computer Science, vol.1679, pp.1119-1209, 1999.

P. J. Berkelman, P. Cinquin, J. Troccaz, J. Ayoubi, C. Letoublon et al., A compact, compliant laparoscopic endoscope manipulator, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292), pp.1870-1875, 2002.
DOI : 10.1109/ROBOT.2002.1014813

V. Boitier, Mise en oeuvre et contrôle d'un robot SCARA à 2 degree de liberte , acctionne par des muscles artificiels pneumatiques de McKibben, 1996.

G. Brandt, K. Radermacher, S. Lavallée, H. Saudte, and G. Rau, A compact robot for image guided Orthopedic Surgery: Concept and preliminary results, First Conference of Computer Vision, Virtual Rality and Robotics (CVRVMEDII) and Medical Robotics and Computer Assisted Surgery (MRCAS III, pp.767-776, 1997.
DOI : 10.1007/BFb0029302

I. Bricault, A fast morphology-based registration application to computer assisted bronchoscopy, Proc CVRMed/MRCAS'97 Lecture Notes in Computer Science Series, pp.417-426, 1997.

M. C. Carroza, L. Lencioni, B. Magnani, S. D. Attanasio, and D. Dario, The development of a microrobot system for colonoscopy, Proc CVRMed, p.97, 1997.
DOI : 10.1007/BFb0029303

S. Charles, H. Das, T. Ohm, C. Boswell, G. Rodriguez et al., Dexterity-enhanced telerobotic microsurgery, 1997 8th International Conference on Advanced Robotics. Proceedings. ICAR'97, 1997.
DOI : 10.1109/ICAR.1997.620154

F. Chassat, Etude et réalisation d'un système de localisation en six dimensions pour la chirurgie assiste par ordinateur, 2001.

R. Clavel, Delta a fast robor with parallel geometry, 18th Int Symp. on Industrial Robot, pp.98-100, 1988.

F. Courrèges, G. Poisson, P. Vieyres, A. Vilchis, J. Troccaz et al., Low level control of antagonist artificial pneumatic muscles for a tele-operated ultrasound robot : Ter, International Symposium on Measurement and Control in Robotics (ISMCR). p. CD, 2002.

F. Courregès, N. Smith, P. Poisson, A. Vieyres, M. Gourdon et al., Real time exhibition of a simulated space tele-echography using an ultralight robot, International Symposium on Artificial Intelligence, Robotics and Automation in Space, 2001.

B. Couteau, Y. Payan, S. Lavallee, and M. C. Hobatho, The Mesh-matching Algorithm: A New Automatic 3D Mesh Generator for Finite Element Analysis, Second International Conference on Medical Image Computing and Computer-Assisted Interventions -MICCAI'99, pp.1175-1182, 1999.
DOI : 10.1007/10704282_127

URL : https://hal.archives-ouvertes.fr/hal-00081970

D. Cunha, P. De, C. Gravez, E. Leroy, J. Maillard et al., The MIDSTEP system for ultrasound guided remote telesurgery, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286), pp.1266-1269, 1998.
DOI : 10.1109/IEMBS.1998.747107

B. L. Davies, A discussion of safety issues for medical robots, Computer Integrated Surgery, pp.287-296, 1996.

B. Davies, W. J. Lin, R. D. Hibberd, and J. C. Cobb, Active compliance in robotic surgery--the use of force control as a dynamic constraint, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol.4, issue.4, pp.285-292, 1999.
DOI : 10.1243/0954411971534403

C. Delgorge, L. Bassit, C. Novales, N. Smith-geérin, G. Poisson et al., Otelo project: mobile tele-echography using an ultra-light robot, 2002.

C. Delgorge, P. Vyeres, G. Poisson, C. Rosenberger, and P. Arbeille, Comparative survey of ultrasound images compression methods dedicated to a tele-scanning robotic system, 2001.

B. S. Dhillon, A. R. Et, and . Fashandi, Safety and reliability assessment techniques in robotics, Robotica, vol.15, issue.6, pp.701-708, 1997.
DOI : 10.1017/S0263574797000829

J. M. Drake, M. Joy, A. Goldenberg, and D. Kreindler, Computer and robotic assisted resection of brain tumors, Proc. Int. Conf. Advanced Robotics (ICAR), pp.888-892, 1991.

G. Duchemin, E. Dombre, F. Pierrot, . Ph, and . Poignet, SCALPP: A Safe Methodology to Robotize Skin Harvesting, MICCAI'01, pp.309-316, 2001.
DOI : 10.1007/3-540-45468-3_37

C. Ducko, E. Stephenson, S. Sankolkar, and R. Damiano, Robotically-assited coronary artery bypass surgery: moving toward a completely endoscopic procedure, Heart Surgery Forum, vol.2, issue.1, pp.29-37, 1999.

P. Finlay, P. Et, and . Morgan, PathFinder image guided robot for neurosurgery, Industrial Robot: An International Journal, vol.30, issue.1, pp.30-34, 2001.
DOI : 10.1108/01439910310457689

T. Fortin, . Jl, G. Coudert, P. Champleboux, S. Sautot et al., Computer-Assisted Dental Implant Surgery Using Computed Tomography, Computer Aided Surgery, vol.7, issue.1, pp.53-58, 1995.
DOI : 10.3109/10929089509106826

G. Glauser, P. Flury, M. Epitauz, Y. Piquet, and C. Burckhardt, Neurosurgical operation with the dedicated robot minerva, EEE EMBS, pp.347-351, 1993.

H. Götte, M. Roth, C. Brack, and F. Gossé, A new less invasive approach to knee surgery using a vision-guided manipulator, In: IARP Workshop on Medical Robots, vol.1, pp.99-107, 1996.

A. Gourdon, . Ph, G. Poignet, P. Poisson, P. Vieyres et al., A new robotic mechanism for medical application, 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399), pp.33-38, 1999.
DOI : 10.1109/AIM.1999.803139

A. Gourdon, . Ph, G. Poignet, Y. Poisson, P. Parmantier et al., Masterslave robotic system for ultrasound scanning, In: In European Medical and Biological Engineering Conference, vol.II, pp.1116-1117, 1999.

A. Gourdon, P. Vieyres, . Ph, M. Poignet, . Szpieg et al., A tele-scanning robotic system using satellite, Arbeille In: In European Medical and Biological Engineering Conference, vol.II, pp.1402-1403, 1999.

P. Green, J. Jensen, J. Hill, and A. Shan, Mobile telepresence surgery, Second Symposium on Medical Robotics and Computer Assisted Surgery Proc (MR- CAS'95, pp.97-103, 1995.

C. O. Grueneis, R. H. Ritcher, and F. F. Hening, Clinical introduction of the caspar system, Proc. of 4th International Symposium on Computer Assisted Orthopedic Surgery, 1999.

A. Guerraz, A. Vilchis, J. Troccaz, P. Cinquin, B. Hennion et al., A haptic virtual environment for tele-echography, Proc of 10th Annual Medicine Meets Virtual Reality Conference, pp.23-26, 2002.

A. Guerraz, Etude du télégeste médical non invasif utilisant un transducteur gestuel à retour d'efforts, 2002.

J. Guiochet, A. Et, and . Vilchis, Safety analysis of a medical robot for tele-echography. In: Second IARP/IEEE-RAS Joint Workshop on Technical Challenge for Dependable Robots in Human Environments, pp.217-227, 2002.
URL : https://hal.archives-ouvertes.fr/hal-01276607

J. Guiochet, Guide de sécurité, 2000.

J. Guiochet, Maitrise de la sécurite des systèmes de la robotique de service, 2003.

G. S. Guthart, J. K. Et, and . Salisbury, The intuitive telesurgery system: Overview and application, Proc IEEE ICRA, 2000.

P. S. Jensen, K. W. Grace, R. Attariwala, J. E. Colgate, and . Glucksberg, Toward robot-assisted vascular microsurgery in the retina, Graefe's Archive for Clinical and Experimental Ophthalmology, vol.180, issue.11, pp.696-701, 1997.
DOI : 10.1007/BF01880668

L. Kavaussi, R. Moore, L. Adams, and A. Partin, Comparaison of robotic versus human laparoscopic camera control, Second Symposium on Medical Robotics and Computer Assisted Surgery SMRCAS'95, pp.284-287, 1995.

P. Kazanzides, J. Zuhars, B. Mittelstad, and R. H. Taylor, Force sensing and control for a surgical robot, Proceedings 1992 IEEE International Conference on Robotics and Automation, pp.291-298, 1996.
DOI : 10.1109/ROBOT.1992.220224

T. C. Kienzle, S. D. Sqtulberg, M. Peshkin, Q. Quqid, J. Leq et al., Total knee replacement, IEEE Engineering in Medicine and Biology Magazine, vol.14, issue.3, pp.301-306, 1995.
DOI : 10.1109/51.391773

G. K. Klute, B. Et, and . Hannaford, Fatigue characteristics of McKibben artificial muscle actuators, Proceedings. 1998 IEEE/RSJ International Conference on Intelligent Robots and Systems. Innovations in Theory, Practice and Applications (Cat. No.98CH36190), pp.1776-1782, 1998.
DOI : 10.1109/IROS.1998.724854

G. Kontaxakis, S. Walter, and G. Sakas, EU-TeleInViVo: an integrated portable telemedicine workstation featuring acquisition, processing and transmission over low-bandwidth lines of 3D ultrasound volume images, Proceedings 2000 IEEE EMBS International Conference on Information Technology Applications in Biomedicine. ITAB-ITIS 2000. Joint Meeting Third IEEE EMBS International Conference on Information Technology Applications in Biomedicine (ITAB'00). Third Works, pp.158-163, 2000.
DOI : 10.1109/ITAB.2000.892378

H. Koyama, Y. Uto, D. Tamura, and T. Komeda, Development of the robot system fot tele-ultrasound imaging diagnosis, 2002.

S. Lavallée and . Ph, 3d imaging in medicinecomputer assited medical interventions, Cinquin Computer Assited Medical Interventions, NATO ASI Series F, issue.60, pp.301-311, 1990.

S. Lavallée, J. Troccaz, L. Gaborit, P. Cinquin, A. L. Benabid et al., Image guided operating robot: a clinical application in stereotactic neurosurgery, Proceedings 1992 IEEE International Conference on Robotics and Automation, pp.618-625, 1992.
DOI : 10.1109/ROBOT.1992.220223

Q. H. Li, L. Zamorano, A. Pandya, R. Perez, J. Gong et al., The Application Accuracy of the NeuroMate Robot???A Quantitative Comparison with Frameless and Frame-Based Surgical Localization Systems, Computer Aided Surgery, vol.44, issue.6, pp.90-98, 2002.
DOI : 10.1097/00005537-199807000-00001

V. Luboz, B. Couteau, and Y. Payan, 3d finite element meshing of entire femora by using the mesh matching algorithm, Proceedings of the Transactions of the 47th Annual Meeting of the Orthopaedics Research Society, pp.522-525, 2001.

T. Lueth, J. Et, and . Bier, Robot assisted intervention in surgery, Neuronavegation -Neurosurgical and Computer Scientific Aspects, 1999.

J. Marescaux, Nom de code??: ????Op??ration Lindbergh????, Annales de Chirurgie, vol.127, issue.1, pp.2-4, 2002.
DOI : 10.1016/S0003-3944(01)00658-7

K. Masuda, N. Tateishi, Y. Suzuki, E. Kimura, Y. Wie et al., Experiment of wireless tele-echography system by controlling echographyc diagnosis robot, MICCAI'02, pp.130-137, 2002.

J. P. Merlet, Les robots parallèles, Hermes, 1997.

J. Merlet, Optimal design for the micro parallel robot MIPS, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292), pp.1149-1154, 2002.
DOI : 10.1109/ROBOT.2002.1014698

M. Mitsuishi, S. Warisawa, T. Tsuda, T. Higuchi, N. Koizumi et al., Remote ultrasound diagnostic system, Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164), pp.1567-1574, 2001.
DOI : 10.1109/ROBOT.2001.932834

F. Pellisier, A. Vilchis, P. Thorel, J. Troccaz, and B. , A force feedback remote ultrasound service, Proc of World Telecommunications Congress, 2002.

B. Peuchot, A. Tanguy, and M. Eude, Virtual rality as an operative tool during scoliosis surgery, Proc CVRMed'95 Lecture Notes in Computer Science Series, pp.549-554, 1995.
DOI : 10.1007/978-3-540-49197-2_72

F. Pierrot, E. Dombre, E. Dégoulange, L. Urbain, P. Caron et al., Hippocrate: a safe robot arm for medical applications with force feedback, Medical Image Analysis, vol.3, issue.3, pp.285-300, 1999.
DOI : 10.1016/S1361-8415(99)80025-5

S. E. Salcudean, G. Bell, S. Bachmann, W. H. Zhu, P. Abolmaesumi et al., Robot-Assisted Diagnostic Ultrasound ??? Design and Feasibility Experiments, Lecture Notes in Computer Science. Medical Image Computing and Computer-Assisted Intervention (MICCAI'99, pp.1062-1071, 1999.
DOI : 10.1007/10704282_115

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.12.2870

O. Schneider, J. Troccaz, O. Chavanon, and D. Blin, PADyC: a synergistic robot for cardiac puncturing, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065), pp.2883-2888, 2000.
DOI : 10.1109/ROBOT.2000.846465

D. Stewart, A platform with 6 degrees of freedom, Proc of the Institution of mechanical engineers, pp.371-386, 1965.

D. Stoianovici, An efficient needle injection technique and radiologie guidance method for percutaneous procedures, Proc CVRMed/MRCAS'97 Lecture Notes in Computer Science, pp.295-298, 1997.

R. H. Taylor, S. Lavalle, A. Burdea, and R. Mösges, Computer integrated surgery. technology and clinical applications, Second International Workshop on Robotics and Computer Assisted Medical Interventions, 1996.
DOI : 10.1097/00003086-199809000-00002

B. Tondu, P. Et, and . Lopez, Modeling and control of McKibben artificial muscle robot actuators, IEEE Control Systems Magazine, vol.20, issue.2, pp.15-38, 2000.
DOI : 10.1109/37.833638

D. Vial, Etude et commande floue d'actionneurs à muscles artificiels de McKibben appliqués à la motorisation de robots manipulateurs, 1997.

A. Vilchis, J. Troccaz, . Ph, A. Cinquin, F. Guerraz et al., Experiments with the TER Tele-echography Robot, Fifth International Conference on Medical Image Computing and Computer Assisted Intervention, pp.138-146, 2002.
DOI : 10.1007/3-540-45786-0_18

URL : https://hal.archives-ouvertes.fr/hal-00021442

A. Vilchis, J. Troccaz, . Ph, K. Cinquin, B. Masuda et al., A new robot architecture for tele-echography, IEEE Transactions on Robotics and Automation, vol.19, issue.5, 2003.
DOI : 10.1109/TRA.2003.817509

A. Vilchis, K. Masuda, J. Troccaz, and . Ph, Robot-based teleechography: the ter system, Cinquin Medical Informatics Europe, 2003.

A. Vilchis, K. Masuda, M. Althuser, J. Ayoubi, and J. Bosson, Robotized tele-echography: from concepts to clinical validation, J. Troccaz et Ph. Cinquin, 2003.

. La-distance-entre-la-sonde, endroit où s'est produit la réflexion (l'écho) est calculée par le temps de vol, en utilisant la vitesse de propagation moyenne des ultrasons dans les tissus mous