| ISIS: a fail-safe interface realised in smart power technology |
|
|
| M. Nicolaidis1, 2N. Zaidan1T. Calin1D. Bied-Charreton1 |
|
|
| Actuators of safety critical systems must be driven by fail-safe signals. Under a failure in the system such a signal has to be either on the correct state or on the safe state. This paper describes a fail-safe interface able to generate the fail-safe signals required in this context. The circuit is realised in a smart-power technology allowing one to deliver fail-safe signals having the power characteristics required in a railway system. It can replace traditional fail-safe interfaces realised by means of bulky and expensive discrete components. |
|
|
|
|
|
|
|
|
| 1 : | TIMA - Techniques of Informatics and Microelectronics for integrated systems Architecture |
| 2 : | IROC TECHNOLOGIES - iROc Technologies |
|
|
|
|
|
|
| ISIS- – fail-safe-interface – smart-power-technology – safety-critical-systems – fail-safe-signals |